AXT630, AXT631, and AXT632 Antenna Distribution System

by user

on
Category: Documents
8

views

Report

Comments

Transcript

AXT630, AXT631, and AXT632 Antenna Distribution System
AXT630, AXT631, and AXT632 Antenna Distribution System
AXT630/AXT631/AXT632 アンテナ分配システム
© 2013 Shure Incorporated
27A21074 (Rev. 1)
Printed in USA
IMPORTANT SAFETY INSTRUCTIONS
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
READ these instructions.
KEEP these instructions.
HEED all warnings.
FOLLOW all instructions.
DO NOT use this apparatus near water.
CLEAN ONLY with dry cloth.
DO NOT block any ventilation openings. Allow sufficient distances for adequate ventilation and install in accordance with the manufacturer’s instructions.
DO NOT install near any heat sources such as open flames, radiators, heat registers,
stoves, or other apparatus (including amplifiers) that produce heat. Do not place any open
flame sources on the product.
DO NOT defeat the safety purpose of the polarized or groundingtype plug. A polarized
plug has two blades with one wider than the other. A grounding type plug has two blades
and a third grounding prong. The wider blade or the third prong are provided for your
safety. If the provided plug does not fit into your outlet, consult an electrician for replacement of the obsolete outlet.
PROTECT the power cord from being walked on or pinched, particularly at plugs, convenience receptacles, and the point where they exit from the apparatus.
ONLY USE attachments/accessories specified by the manufacturer.
USE only with a cart, stand, tripod, bracket, or table specified by the manufacturer, or sold with the apparatus. When a cart is used, use caution when
moving the cart/apparatus combination to avoid injury from tip-over.
UNPLUG this apparatus during lightning storms or when unused for long
periods of time.
14. REFER all servicing to qualified service personnel. Servicing is required when the apparatus has been damaged in any way, such as power supply cord or plug is damaged,
liquid has been spilled or objects have fallen into the apparatus, the apparatus has been
exposed to rain or moisture, does not operate normally, or has been dropped.
15. DO NOT expose the apparatus to dripping and splashing. DO NOT put objects filled with
liquids, such as vases, on the apparatus.
16. The MAINS plug or an appliance coupler shall remain readily operable.
17. The airborne noise of the Apparatus does not exceed 70dB (A).
18. Apparatus with CLASS I construction shall be connected to a MAINS socket outlet with a
protective earthing connection.
19. To reduce the risk of fire or electric shock, do not expose this apparatus to rain or
moisture.
20. Do not attempt to modify this product. Doing so could result in personal injury and/or
product failure.
21. Operate this product within its specified operating temperature range.
This symbol indicates that dangerous voltage constituting a risk of
electric shock is present within this unit.
This symbol indicates that there are important operating and maintenance instructions in the literature accompanying this unit.
WARNING: This product contains a chemical known to the State of California to cause cancer and birth
defects or other reproductive harm.
AXT630, AXT631 and AXT632 Antenna Distribution Systems
Antenna Distribution Systems send the RF signal from a single pair of antennas to multiple receivers. Ultra-linear amplification and adjustable attenuation optimize performance in difficult RF environments. Selectable input filters match the available frequency bands of transmitters, providing extra
protection from strong out-of-band signals. BNC antenna output pairs distribute band-filtered signals to up to 4 receivers. A pair of wideband cascade
ports supply wideband RF signals to Spectrum Managers or additional antenna distribution amplifiers. Networking allows Wireless Workbench to control
filtering ranges and attenuation.
To maximize use of the RF spectrum, Antenna Distribution Systems are available in the following frequency ranges:
• AXT630 (470-698 MHz)
• AXT631 (606-814 MHz)
• AXT632 (470–787 MHz)
Note:Instructions in the system guide apply all models of Antenna Distributions Systems in this guide.
Features
• Selectable input filtering provides system-wide protection against strong out-of-band signals
• Wideband filtering option covers multiple bands
• Up to 15 dB of selectable RF attenuation for signal-to-noise optimization
• Front panel interface and Wireless Workbench 6 software control provide easy setup and control of filtering, antenna power, and attenuation
• BNC outputs: 4 antenna output pairs
• Wideband RF cascade port with selectable 3 dB make-up gain for connecting wideband devices
• Ethernet Networking: 2 PoE enabled Ethernet ports
• IEC power ports enable daisy-chaining of AC power
Included Components
2-foot Coaxial Antenna Cable (RG-58) (12)
UA802
IEC AC Power Cable (1)
95A9128
IEC AC Extension Cable (1)
95A9129
Shielded 3-foot Ethernet Cable (1)
C803
Shielded 8-inch Ethernet Jumper Cable (1)
C8006
Hardware Kit (1)
90XN1371
22-inch Coaxial Cable* (1)
95B9023
Mounting Instructions
This component is designed to fit into an audio rack.
WARNING: To prevent injury this apparatus must be securely attached to the rack.
33-inch Coaxial Cable* (1)
95C9023
*with integrated bulkhead for front mounting antennas.
Optional Accessories
Antennas
1/2 Wave Antennas
(744-865 MHz)
UA820G
(690-746 MHz)
UA820H4
(554-590 MHz)
UA820J
(606-666 MHz)
UA820K
(638-698 MHz)
UA820L3
(694-758 MHz)
UA820M
(740-814 MHz)
UA820Q
(710-790 MHz)
UA820P8
Passive Omnidirectional Antenna (470-1100 MHz)
UA860SWB
Passive Directional Antenna (470-952 MHz)
PA805SWB
PWS Helical Antenna (480-900 MHz)
HA-8089
In-Line RF Amplifiers
(470-900 MHz)
UA830WB
(470-698 MHz)
UA830USTV
Active Directional Antennas
Cables
25-foot Coaxial Cable RG8/X
UA825
50-foot Coaxial Cable RG8/X
UA850
100-foot (30.4 m) Antenna Extension Cable
UA8100
5
470-698 MHz
UA874US
470-790 MHz
UA874E
470-900 MHz
UA874WB
925-952 MHz
UA874X
Controls and Connectors
1
2
3
power
AXT631
606-814 MHz
SET
Antenna Distribution
Amplifier
5
4
6
7
9
12
AXT631
RF outputs
RF outputs
4B
3B
2B
1B
4A
3A
2A
antenna
in
1A
14
B
A
PoE Class 1
10
8
① LCD Display
Displays menu and settings.
11
13
⑨ Network status LED (green)
• Off = no network link
• On = network link active
• Flashing = network link active, flash rate corresponds to traffic
volume
② Navigation Buttons
• Arrows: Scroll menus and change settings
• SET: Enables menu edits and saves changes
⑩ RF Output Connectors, Channel B
Distributes RF signal for Channel B
③ Power Switch
Powers the unit on or off
⑪ RF Output Connectors, Channel A
Distributes RF signal for Channel A
④ AC Power Primary Switch
AC Main Power Switch
⑤ AC Power In
IEC Connector, 100-240 V AC
⑫ Antenna IN Ports, Channels A and B
Antenna inputs are DC biased for use with active antennas or in-line
amplifiers.
⑥ AC Power Cascade
Use the IEC extension cables to connect up to 5 devices to a single
AC power source.
⑬ RF Cascade Ports, Channels A and B
Passes the wideband RF signal from one device to the next, allowing
up to 5 devices to share a single pair of antennas.
⑦ Network Speed LED (amber):
• Off = 10 Mbps
• On = 100 Mbps
⑭ Antenna Input Status LED
• Green = DC power on
• Off = DC power off
• Red = Antenna fault or over-current condition
⑧ Ethernet Ports (2)
PoE Class 1 enabled. Connect to an Ethernet network to enable
remote control and monitoring
6
Antennas
The Antenna Distribution Systems are compatible with front-mounted antennas or with remote-mounted antennas.
Note: When using the input band filtering function, select an antenna with bandwidth to cover the filter range.
Installing Front-mounted Antennas
Mounting the antennas on the front panel improves system performance by providing a clear signal path for the RF signal. Use the supplied bulkhead
adapter kit to install the antennas on the front panel.
1.Insert the bulkhead adapters on the supplied front-mounting cables through the holes in each bracket and secure them from the front using the supplied hardware.
2.Connect the supplied antennas cables to the antenna input BNC connectors.
3.Install the antenna onto the bulkhead adapters.
Note: To minimize the possibility of signal dropout and optimize performance, point the antennas up and away from each other at 45° from vertical.
Installing Remote Antennas
Remote antennas offer greater flexibility for antenna placements and can improve performance by providing a less obstructed transmission path and
extending range. Consult http://www.shure.com for tips and best practices for remote mounting antennas.
RF Output Distribution
RF Cascade Ports
RF outputs
RF outputs
RF outputs
4B
3B
2B
4A
1B
4B
3A
2A
3B
2B
1A
RF outputs
antenna
in
4A
1B
3A
12.7V
OUT
150 mA
2A
antenna
in
1A
12.7V
OUT
150 mA
cascade
out
B
cascade
out
A
B
The RF outputs distribute the signal from a pair of antennas to up to 4
receivers or additional antenna distribution systems. Port-to-port isolation reduces interference, making the distribution ports the best option
for distributing signal to additional devices.
The RF cascade ports extend the Antenna Distribution System by providing a connection point for additional receivers, Spectrum Managers, or
Antenna Distribution Systems.
When Antenna Cascade is set to Auto, the Cascade ports automatically
activate when 12 V DC from the antenna input of a connected device is
sensed at the port connection. When the cascade ports are active, a signal
splitting loss occurs of 5 dB (max.).
Connecting Devices
Connect an A and B pair of RF outputs from the Antenna System to the
A and B inputs of the device.
RF outputs
RF outputs
4B
3B
2B
1B
4A
3A
2A
A
Receivers with RF cascade outputs can extend the antenna signal to additional receivers within the same band.
antenna
in
1A
12.7V
OUT
150 mA
cascade
out
B
Adding an AXT600 Spectrum Manager to
an Antenna System
A
antenna
in
12.7V
OUT
150 mA
cascade
out
B
A
Connect the AXT600 Spectrum Manager to the RF Cascade ports of the
Antenna Distribution System.
Input Band Filtering
The input band filters act on the RF distribution ports but do not affect
the RF cascade ports. The Wideband setting passes the full frequency
range of the Antenna Distribution System. Select the band filter that
most closely matches the tuning range of connected devices to optimize performance.
RF outputs
RF outputs
4B
3B
2B
1B
4A
3A
2A
antenna
in
1A
12.7V
OUT
150 mA
cascade
out
B
A
When a band filter has been set, operate and tune connected devices within the selected
band.
antenna
in
12.7V
OUT
150 mA
cascade
out
B
Gain and Attenuation
Use the RF Gain menu to maintain consistent signal levels sent to
connected devices. The available adjustment range is -12 to +3 dB
when the Cascade ports are off and -15 to 0 dB when the cascade
ports are active.
7
A
Multiple Levels of Antenna Distribution
For large configurations, multiple Antenna Distribution Systems can be layered to support several levels of signal distribution:
• Two levels of antenna distribution are possible if the level 1 and level 2 Antenna Distribution Systems have the Cascade ports activated
• Up to 3 levels of antenna distribution are possible if only the level 1 Antenna Distribution System has the Cascade ports activated
• For best RF performance, use all the RF outputs on one level before creating additional levels
Level 1: Antenna
Distribution System set to
Wideband
Level 2: Antenna Distribution
System set to a band filter
matching the 4 receivers tuned
to the same band
Cascade Ports
AXT631 (Wideband)
AXT631 (G1 Filtered)
RF Outputs
AXT631 (H4 Filtered)
Receiver (G1)
Receiver (H4)
Receiver (G1)
Receiver (H4)
Receiver (G1)
Receiver (H4)
Receiver (G1)
Receiver (H4)
AXT600
Connect the AXT600
Spectrum Manager to the RF
cascade ports of the Level 1
Antenna Distribution System
Troubleshooting
Antenna Faults
Antenna
Fault
Over Temperature Message
The antenna input status LED flashes red to
indicate
a short or over-current condition at an
SET
antenna port. To isolate the fault, navigate to the
DC power menu. The menu displays which antenna port (A, B, or A+B) is the source of the fault.
Check the antenna connections to remove the
fault condition.
Over
Temperature
The Over Temperature message is displayed when
SETfans are unable to cool efficiently, indicating an
the
elevated temperature condition.
• Press any button to suppress the message for 20
seconds
• Increase ventilation to the unit to clear the
message
Main Menu
Use the main menu to select the band filter, adjust the RF gain, and configure the antenna ports.
Band
Antenna Cascade
Selecting an input Band filter optimizes performance when the components connected to the RF outputs are all within the same band. The
selected band filter will only pass frequencies within the range of the
connected components. Four selectable input filters are available to
match the frequency bands transmitters and receivers. A Wideband
setting is available to extend frequency support across all 4 bands.
This setting allows receivers operating in a variety of bands to use the
RF outputs.
Auto
The ports will activate when a connected device supplies 12-15 V DC to
the port.
On
The ports are continuously active, independent of voltage applied by a
connected device.
To set the Band filter:
Antenna Power
1.Navigate to the Band menu and press the SET button to enable
editing.
ON
The antenna ports supply 12-15 V DC to power active antennas.
2.Use the arrows to select a band filter or to select the Wideband
setting.
3.Press the SET button to save changes.
OFF
Turns off DC voltage at the antenna ports.
RF Gain
Network Status
Adjust the RF gain to boost or attenuate the antenna signal to maintain
consistent levels and prevent overload. Gain adjustments are made in
1 dB increments.
Active
Indicates connectivity with other devices on the network.
The gain adjustment range depends on the connection status of the
RF cascade ports:
Inactive
No connectivity with other devices on the network.
• Cascade ports connected: adjustment range = -15 dB to 0 dB
Note: IP address must be valid to enable networked control.
• Cascade ports not connected: adjustment range = -12 dB to +3 dB
8
Utility Menu
Press and hold both arrow keys to enter and exit the utility menu, which is used to access network and display settings.
SET
hold both arrow keys
IP Address Mode:
Automatic
This is the default setting for use with a DHCP
server, which automatically assigns an IP
address.
1.Navigate to the IP Mode menu and press
the SET key.
2.Use the arrow keys to highlight Automatic.
3.Press the SET key.
4.Use the arrow keys to move the ► to select
OK to save or Cancel to discard, and then
press the SET key.
IP Address Mode: Manual
Use manual IP addressing to set the IP address and subnet mask when a DHCP server
is not available.
1.Navigate to the IP mode menu and press
the SET key.
2.Use the arrow keys to highlight Manual.
3.Press the SET key to enable editing of the
IP address and the subnet mask.
4.Use the arrow keys to move the ► to select
IP: or Sub:
5.Use the arrow keys and the SET key to edit
the IP address and subnet mask.
MAC (MAC Address)
Displays the MAC address, which is an embedded, uneditable identification number
unique to each device. Used by the network
and WWB software to identify components.
Device ID
This eight-character name is displayed when
this device is detected on other network devices or in WWB software.
Display Invert
This changes the LCD menu from white text
on dark background to dark text on a light
background.
Front Panel Lock
Locks or unlocks the navigation buttons to
prevent accidental or unauthorized changes
to settings.
On
1.Press SET key to enable editing.
Locks the navigation buttons.
2.Use the arrow keys to change the
characters.
Off
3.To finish editing, press the SET key until
none of the characters are highlighted.
Power Switch Lock
Serial Number
On
Displays the serial number.
Unlocks the navigation buttons.
Lock the power switch to ensure that power is
not accidentally turned off.
Off
Firmware
Displays the version of firmware installed on
this device.
Brightness
Sets the brightness of the LCD to low, medium, or high.
6.Use the arrow keys to move the ► to select
OK to save or Cancel to discard, and then
press the SET key.
Locks the power switch.
Unlocks the power switch.
Fan (Cooling Fan Mode)
Automatic
The fan is enabled and adjusts speed
based on the internal temperature of the
unit.
Always on
The fan runs continuously at maximum
speed to provide maximum cooling in
warm environments.
Firmware Updates
Firmware is embedded software in each component that controls functionality. Periodically,
new versions of firmware are developed to
incorporate additional features and enhancements. To take advantage of design improvements, new versions of the firmware can be
uploaded and installed using the Firmware
Update Manager tool available in WWB6 software. Firmware is available for download from
http://www.shure.com.
9
Specifications -- AXT630, AXT631, AXT632
RF Frequency Range
Dimensions
44 mm x 483 mm x 366 mm (1.7 in. x 19.0 in. x 14.4 in.), H x W x D
Weight
4.6 kg (10.1 lbs),
Housing
Steel; Extruded aluminum
Operating Temperature Range
-18°C (0°F) to 63°C (145°F)
Storage Temperature Range
-29°C (-20°F) to 74°C (165°F)
Power Requirements
100 to 240 V AC, 50-60 Hz
Current Drain
1.0 A RMS (referenced at 120 V AC)
AXT632
606–814 MHz
AXT 632
470–787 MHz
Connector Type
BNC (4 pairs)
Configuration
Unbalanced, active
Impedance
50 Ω
Gain Adjustment Range
Cascade Enabled
-15 dB to 0 dB (In 1 dB steps)
Cascade Disabled
-12 dB to +3 dB (In 1 dB steps)
Output Intercept Point
>25 dBm, typical
Connector Type
BNC
Configuration
Unbalanced, active
Band Filters
AXT631
470–698 MHz
AXT 631
Distribution Output
RF Input
AXT630
AXT 630
Cascade Output
Wideband
470–698 MHz
Band G1
470–530 MHz
Band H4
518–578 MHz
Band J5
578–638 MHz
Band L3
638–698 MHz
Wideband
606–814 MHz
Band K4E
606–666 MHz
Band M8
666–730 MHz
Band P8, P9
710–790 MHz
Band Q5
740–814 MHz
Wideband
470–787 MHz
Band G7C
470–510 MHz
Band L3E
638–698 MHz
Band M8
666–730 MHz
Connector Type
BNC (1 pair)
Configuration
Unbalanced, wideband
Impedance
50 Ω
Insertion Loss
<5 dB
Networking
Power Over Ethernet (PoE)
50 V DC, Class 1
Network Interface
Dual Port Ethernet 10/100 Mbps
Network Addressing Capability
DHCP or Manual IP address
Band P9
710–787 MHz
Impedance
50 Ω
Bias Voltage
12 V DC, 150 mA (300 mA maximum)
10
AXT 630/ AXT631 Circuit Diagram
Antenna In
Cascade Out
50 Ω
Distro Out 1
50 Ω
0 dB
Distro Out 2
50 Ω
-3.5 dB
() Denotes gain when cascade is disabled
Distro Out 3
-15 dB to 0 dB
(-12 dB to +3 dB)
Distro Out 4
50 Ω
50 Ω
-15 dB to 0 dB
(-12 dB to +3 dB)
50 Ω
-15 dB to 0 dB
(-12 dB to +3 dB)
Passive Splitter
-15 dB to 0 dB
(-12 dB to +3 dB)
Passive Splitter
-3.5 dB
(Cascade Bypass)
Filter Select Switch
Passive Splitter
Filter Select Switch
Filter 1
Filter 2
Filter 3
Filter 4
User Gain Adjust
Passive Splitter
Wide Band
Certifications
AXT630/AXT631/AXT632 Circuit Diagram
AXT630, AXT631, and AXT632
Meets essential requirements of the following European Directives:
• R&TTE Directive 99/5/EC
• Conforms to European Regulation (EC) No. 1275/2008, as amended.
• WEEE Directive 2002/96/EC, as amended by 2008/34/EC
• RoHS Directive 2002/95/EC, as amended by 2008/35/EC
Note: Please follow your regional recycling scheme for batteries and electronic waste
Meets requirements of the following standards: EN 300 422 Parts 1 and 2, EN 301 489 Parts 1 and 9, EN60065.
EN 300 422 Parts 1 and 2. EN 301 489 Parts 1 and 9. EN60065.
AXT630
Approved under the Declaration of Conformity (DoC) provision of FCC Part 15.
Meets Industry Canada RSS-123.
This Class B digital apparatus complies with Canadian ICES-003. Cet appareil numérique de la classe B est conforme à la norme NMB-003 du Canada.
This device complies with Industry Canada license-exempt RSS standard(s).
Information to the user
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits
are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or
more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and the receiver.
• Connect the equipment to an outlet on a circuit different from that to which the receiver is connected.
• Consult the dealer or an experienced radio/TV technician for help.
Note: EMC conformance testing is based on the use of supplied and recommended cable types. The use of other cable types may degrade EMC performance.
Changes or modifications not expressly approved by the manufacturer could void the user’s authority to operate the equipment.
The CE Declaration of Conformity can be obtained from Shure Incorporated or any of its European representatives. For contact information please visit
www.shure.com
The CE Declaration of Conformity can be obtained from: www.shure.com/europe/compliance
Authorized European representative:
Shure Europe GmbH
Headquarters Europe, Middle East & Africa
Department: EMEA Approval
Jakob-Dieffenbacher-Str. 12
75031 Eppingen, Germany
Phone: 49-7262-92 49 0
Fax: 49-7262-92 49 11 4
Email: [email protected]
11
AXT630、AXT631、AXT632アンテナ分配システム
アンテナ分配システムは、1ペアのアンテナからのRF信号を複数の受信機に送ります。 ウルトラリニアアンプと調整式アッテネーションにより、難し
いRF環境でも性能を最適化します。 選択式の入力フィルターは、送信機で使用可能な周波数バンドに一致しており、強力な帯域外信号に対し強固に
保護します。 BNCアンテナ出力ペアは、バンドフィルターされた信号を最大4台の受信機に分配できます。 ペアのワイドバンド・カスケードポート
は、ワイドバンドのRF信号をスペクトラムマネージャーまたは別のアンテナ分配アンプに供給します。 ネットワークはWireless Workbenchでフィル
タリングレンジとアッテネーションをコントロールすることができます。
RFスペクトラムの使用を最大化するために、アンテナ分配システムは以下の周波数レンジで使用できます:
• AXT630 (470~698 MHz)
• AXT631 (606~814 MHz)
• AXT632 (470~787 MHz)
注記:システムガイドの説明はこのガイドのアンテナ分配システムの全モデルに適用されます。
機能
• 選択可能な入力フィルタリングは、強力な帯域外信号からシステム全体を保護します
• ワイドバンドフィルタリングオプションは複数のバンドをカバー
• 最大15 dBの選択式RFアッテネーションによりS/Nを最適化
• フロントパネルインターフェースとWireless Workbench 6ソフトウェアコントロールにより、フィルタリングコントロール、アンテナ出力、アッテ
ネーションの簡単なセットアップとコントロールができます
• BNC出力:4ペアのアンテナ出力
• ワイドバンドRFカスケードポートと選択式の3 dBメイクアップゲインにより、広帯域な機器が接続できます。
• イーサネットネットワーク:2つのPoE対応イーサネットポート
• IEC電源ポートはAC電源をデイジーチェーン接続できます
付属品
取り付け方法
60cm同軸アンテナケーブル
(RG-58)(12本)
UA802
IEC AC電源ケーブル(1本)
95A9128
IEC AC延長ケーブル(1本)
95A9129
シールド付90cmイーサネット
ケーブル(1本)
C803
シールド付20cmイーサネット
ジャンパーケーブル(1本)
C8006
ハードウェアキット(1個)
90XN1371
55cm同軸ケーブル*(1本)
95B9023
本ユニットはラックマウント用としてデザインされています。
警告:怪我防止のため機器は確実にラックに固定してください。
85cm同軸ケーブル*(1本)
95C9023
* フロント取り付けアンテナ用一体型バルクヘッド付き。
オプションのアクセサリー
1/2波長アンテナ
アンテナ
(744~865 MHz)
UA820G
パッシブ無指向性アンテナ (470~1100 MHz)
UA860SWB
(690~746 MHz)
UA820H4
パッシブ指向性アンテナ (470~952 MHz)
PA805SWB
(554~590 MHz)
UA820J
PWSヘリカルアンテナ (480~900 MHz)
HA-8089
(606~666 MHz)
UA820K
(638~698 MHz)
UA820L3
(694~758 MHz)
UA820M
(740~814 MHz)
UA820Q
(710~790 MHz)
UA820P8
インラインRFアンプ
UA825
同軸ケーブルRG8/X、15 m
UA850
アンテナ延長ケーブル
RG213/U、30.4 m
UA8100
UA830WB
(470~698 MHz)
UA830USTV
アクティブ指向性アンテナ
ケーブル
同軸ケーブルRG8/X、7.5 m
(470~900 MHz)
13
470~698 MHz
UA874US
470~790 MHz
UA874E
470~900 MHz
UA874WB
925~952 MHz
UA874X
コントロールとコネクター
1
2
3
power
AXT631
606-814 MHz
SET
Antenna Distribution
Amplifier
5
4
6
7
9
12
AXT631
RF outputs
RF outputs
4B
3B
2B
1B
4A
3A
2A
antenna
in
1A
14
B
A
PoE Class 1
10
8
① LCDディスプレイ
メニューと設定を表示します。
11
13
⑨ ネットワークステータスLED(緑色)
• 消灯 = ネットワークリンク無効
• 点灯 = ネットワークリンク有効
• 点滅 = ネットワークリンクは有効で、点滅速度はトラフィック量
に対応
② ナビゲーションボタン
• 矢印:メニューをスクロールし設定を変更します
• SET:メニュー編集と変更の保存ができます
⑩ RF出力コネクター、チャンネルB
チャンネルBにRF信号を分配します
③ 電源スイッチ
ユニットの電源をオン/オフします
⑪ RF出力コネクター、チャンネルA
チャンネルAにRF信号を分配します
④ AC電源プライマリースイッチ
メインAC電源スイッチ
⑤ AC電源イン
IECコネクター AC100~240 V
⑫ アンテナ入力ポート、チャンネルAとB
アンテナ入力は、アクティブアンテナまたはインラインアンテナを使
用するためにDCバイアス仕様となっています。
⑥ AC電源カスケード
IEC延長ケーブルを用いれば、最大5台のラックユニットを1つのAC電
源に接続できます。
⑬ RFカスケードポート、チャンネルAとB
ひとつの機器から次の機器に広帯域RF信号を送り、最大5台までで1
ペアのアンテナを共有することができます。
⑦ ネットワーク速度LED(オレンジ):
• 消灯 = 10 Mbps
• 点灯 = 100 Mbps
⑭ アンテナ入力ステータスLED
• 緑色 = DC電源オン
• 消灯 = DC電源オフ
• 赤色 = アンテナ故障または過電流
⑧ イーサネットポート(2ポート)
クラス1 PoE対応イーサネットネットワークに接続してリモートコン
トロールとモニタリングを可能にします
14
アンテナ
アンテナ分配システムはフロントマウントアンテナまたはリモートマウントアンテナが使用できます。
注: 入力帯域フィルタリング機能を使用する場合、フィルターレンジをカバーする帯域幅のアンテナを選択してください。
フロントマウントアンテナの設置
フロントパネルにアンテナを設置すると、RF信号への信号パスがクリアになりシステムの性能が向上します。付属のバルクヘッドアダプターキットを
使用し、フロントパネルにアンテナを取り付けます。
1.付属のフロントマウント用ケーブルのバルクヘッドアダプターを両ラックイヤーの穴に挿入し、付属の金具により前面側から固定します。
2.付属アンテナケーブルをアンテナ入力BNCコネクターに接続します。
3.アンテナをバルクヘッドアダプターに取り付けます。
注:信号のドロップアウトを最小限に抑えつつ性能を最適化するには、アンテナを上に向けて縦方向でそれぞれ45°離してください。
リモートアンテナの設置
リモートアンテナは、アンテナの設置場所に柔軟性を与え、また、送信パスの妨害が少なくなりレンジも伸びることで性能を改善できます。リモート
マウントアンテナに関するヒントとベストプラクティスについてはhttp://www.shure.comを参照してください。
RF出力の分配
RFカスケードポート
RF outputs
RF outputs
RF outputs
4B
3B
2B
4A
1B
4B
3A
2A
3B
2B
1A
RF outputs
antenna
in
4A
1B
3A
12.7V
OUT
150 mA
2A
antenna
in
1A
12.7V
OUT
150 mA
cascade
out
B
cascade
out
A
B
RF出力は、1ペアのアンテナ信号を最大4台の受信機または追加のアン
テナ分配システムに分配します。 ポート間を分離することで干渉を低
下させることができるので、信号を他の機器に分配する際には分配ポ
ートが最適なオプションとなります。
RFカスケードポートは、追加受信機、スペクトラムマネージャー、アンテ
ナ分配システムに接続ポイントを提供することで、アンテナ分配システム
を拡張します。
アンテナカスケードをオートに設定した場合、接続した機器のアンテナ入
力からのDC 12 Vがポート接続部で検知されると、カスケードポートは自
動的に有効になります。カスケードポートが有効のとき、5 dB(最大)の
信号分配損失が生じます。
機器の接続
アンテナシステムのAとBのペアのRF出力を機器のAとB入力に接続し
ます。
RF outputs
RF outputs
4B
3B
2B
1B
4A
3A
2A
A
RFカスケード出力を使用する受信機は、同じバンドの受信機にアンテナ信
号を拡張することができます。
antenna
in
1A
12.7V
OUT
150 mA
cascade
out
B
AXT600スペクトラムマネージャーをアン
テナシステムに追加する
A
antenna
in
12.7V
OUT
150 mA
cascade
out
B
A
AXT600スペクトラムマネージャーをアンテナ分配システムのRFカスケー
ドポートに接続します。
入力バンドフィルタリング
入力のバンドフィルターはRF分配ポートに働きますが、RFカスケー
ドポートには影響しません。 ワイドバンド設定は、アンテナ分配シ
ステムのフル周波数レンジを通します。 性能を最適化するには、接
続した機器のチューニング範囲にもっとも近いバンドフィルターを選
択します。
RF outputs
RF outputs
4B
3B
2B
1B
4A
3A
2A
antenna
in
1A
12.7V
OUT
150 mA
cascade
out
B
A
バンドフィルターを設定したら、接続した機器を作動させて選択したバンド内でチューニン
グします。
antenna
in
12.7V
OUT
150 mA
cascade
out
B
ゲインおよびアッテネーション
RFゲインメニューを使って接続した機器に送る信号レベルを一定に
保ちます。 調整範囲は、カスケードポートをオフにした場合-12~+3
dBで、有効にした場合は-15~0 dBです。
15
A
アンテナ分配の複数のレベル
大規模な構成では、複数のアンテナ分配システムを階層化して複数の信号分配レベルをサポートすることができます:
• レベル1とレベル2のアンテナ分配システムのカスケードポートを有効にすれば、2レベルのアンテナ分配が可能です。
• レベル1のアンテナ分配システムのみカスケードポートを有効とした場合には、最大3レベルのアンテナ分配が可能です。
• 最適なRF性能を得るためには、1つのレベルですべてのRF出力を使用してから追加レベルを作成します。
レベル1: ワイドバンドに
設定したアンテナ分配シス
テム
レベル2: 同じバンドに調整し
た4台の受信機に一致するバン
ドフィルターに設定したアンテ
ナ分配システム
Cascade Ports
AXT631 (Wideband)
AXT631 (G1 Filtered)
RF Outputs
AXT631 (H4 Filtered)
Receiver (G1)
Receiver (H4)
Receiver (G1)
Receiver (H4)
Receiver (G1)
Receiver (H4)
Receiver (G1)
Receiver (H4)
AXT600
AXT600スペクトラムマネー
ジャーをレベル1アンテナ分
配システムのRFカスケード
ポートに接続します
トラブルシューティング
アンテナの故障
Antenna
Fault
温度超過メッセージ
アンテナ入力ステータスLEDが赤く点滅ししてい
SET
る場合、アンテナポートのショートまたは過電流
を表しています。不具合を分離するには、DC電
源メニューにナビゲートします。メニューにはど
のアンテナポートが不具合の原因であるかが表示
されます(A、B、またはA+B)。アンテナ接続を
チェックして不具合を除去します。
Over
Temperature
Over Temperatureメッセージは、ファンの冷却効
SET
率が失われたときに表示され、温度上昇を通知しま
す。
• いずれかのボタンを20秒間押すとメッセージが表
示されなくなります
• ユニットの通気を増やしてメッセージが出ないよ
うにします
メインメニュー
メインメニューを使って、バンドフィルターの選択、RFゲインの調整、アンテナポートの設定を行います。
Band
Antenna Cascade
RF出力に接続した機器がすべて同じバンドにあるとき、入力Bandフ
ィルターを選択することで性能が最適化されます。選択したバンドフ
ィルターが、接続した機器のレンジ内の周波数のみを送ります。周波
数バンドの送信機と受信機に一致する、4種類の入力フィルターが選
択できます。4つすべてのバンドをサポートするWideband設定も選択
できます。この設定では、異なるバンドで動作する受信機がRF出力を
使用できるようになります。
Auto
接続した機器がポートへDC 12~15 Vを供給すると作動します。
On
バンドフィルターを設定するには:
接続機器からの電圧に関係なくポートは継続的に有効となります。
Antenna Power
1.Bandメニューにナビゲートし、SETボタンを押して編集を有効に
します。
ON
アンテナポートはアクティブアンテナ用にDC 12~15 Vを供給します。
2.矢印を使用してバンドフィルターを選択するか、Wideband設定を
選択します。
3.SETボタンを押して変更を保存します。
OFF
アンテナポートのDC電圧をオフにします。
RF Gain
Network Status
RFゲインを調整してアンテナ信号をブーストまたは減衰し、一定した
レベルを維持してオーバーロードを防止します。ゲイン調整は1 dB単
位で可能です。
Active
ネットワーク上の他の機器と接続していることを表します。
ゲイン調整範囲は、RFカスケードポートの接続ステータスにより異
なります:
Inactive
ネットワーク上の他の機器との接続がないことを表します。
• カスケードポート接続:調整範囲 = -15 dB~0 dB
注: ネットワークコントロールには正しいIPアドレスに設定することが必要です。
• カスケードポート非接続:調整範囲 = -12 dB~+3 dB
16
ユーティリティメニュー
両方の矢印キーを押したままにすると、ユーティリティメニューを表示/終了できます。このメニューではネットワークと表示設定を変更することがで
きます。
SET
両方の矢印キーを押したままにする
IPアドレスモー
ド:Automatic
これはIPアドレスを自動的に割り当てる
DHCPサーバーとともに使用する、工場出荷
時の設定です。
1.IPモードメニューを開きSETキーを押し
ます。
2.矢印キーを使用してAutomaticをハイライ
トします。
MAC(MACアドレス)
Display Invert
MACアドレスを表示します。これは埋め込ま
れた編集できない識別番号で、各機器固有の
ものです。ネットワークとWWBソフトウェ
アによってユニットの識別に使用されます。
LCDメニューを白文字で黒背景から黒文字で
白背景に変更します。
Device ID
この機器が他のネットワーク機器または
WWBソフトウェアで検出された場合、この8
文字の名前が表示されます。
3.SETキーを押します。
1.SETキーを押して編集を有効にします。
4.矢印キーを使って►を動かし、OKを選択
して保存するか、Cancelを選択して取りや
め、SETキーを押します。
3.編集を終了するには、どの文字もハイライ
トされなくなるまでSETキーを押します。
IPアドレスモード:Manual
DHCPサーバーが使用できない場合は、マニ
ュアルIPアドレスを使用してIPアドレスとサ
ブネットマスクを設定します。
1.IPモードメニューを開きSETキーを押し
ます。
2.矢印キーを使用してManualをハイライト
します。
3.SETキーを押してIPアドレスとサブネット
マスクの編集を有効にします。
4.矢印キーを使用して►を動かしIP:また
はSub:を選択します
2.矢印キーを使って文字を変更します。
Front Panel Lock
ナビゲーションボタンをロック/ロック解除
し、誤って設定を変更しないようにします。
On
Off
ナビゲーションボタンをロックします。
ナビゲーションボタンのロックを解除し
ます。
Power Switch Lock
電源スイッチをロックして電源が誤ってオフ
にならないようにします。
製造番号
製造番号を表示します。
On
Off
Firmware
この機器にインストールされているファーム
ウェアのバージョンを表示します。
Brightness
LCDの明るさを低、中、高に設定します。
5.矢印キーとSETキーを使ってIPアドレスと
サブネットマスクを編集します。
6.矢印キーを使って►を動かし、OKを選択
して保存するか、Cancelを選択して取りや
め、SETキーを押します。
電源スイッチをロックします。
電源スイッチのロックを解除します。
Fan(冷却ファンモード)
Automatic
ファンが有効になり、ユニットの内部温
度に応じて速度が調整されます。
Always on
ファンは最高速度で稼働し続け、高温環
境下で最高の冷却機能を提供します。
ファームウェアアップデ
ート
ファームウェアは各ユニットに組み込まれた
ソフトウェアで、動作をコントロールしま
す。追加機能や改善点を取り入れた新しいフ
ァームウェアが定期的に公開されます。改良
された設計を適用するには、WWB6ソフト
ウェアのファームウェアアップデートマネー
ジャーツールを使用して最新バージョンのフ
ァームウェアをアップロードしインストール
します。ファームウェアはhttp://www.shure.
comからダウンロードできます。
17
仕様 -- AXT630, AXT631, AXT632
RF周波数範囲
寸法
44 mm x 483 mm x 366 mm (1.7 インチ x 19.0 インチ x 14.4 インチ), 高
さ×幅×奥行き
質量
4.6 kg (10.1 lb),
外装
スチール、押出成型アルミニウム
動作温度範囲
-18°
C (0°
F) ~ 63°
C (145°
F)
保管温度範囲
-29°
C (-20°
F) ~ 74°
C (165°
F)
使用電源
100 ~ 240 V AC, 50-60 Hz
消費電流
1.0 A RMS (120 V AC基準)
AXT632
606~814 MHz
AXT 632
470~787 MHz
コネクターの種
BNC (4ペア)
構成
アンバランス、
アクティブ
インピーダンス
50 Ω
ゲイン調整範囲
カスケード有効
-15dB ~ 0dB (1 dB刻み)
カスケード無効
-12dB ~ +3dB (1 dB刻み)
出力インターセプトポイント
>25 dBm, 標準
コネクターの種
BNC
構成
アンバランス、
アクティブ
帯域フィルター
AXT631
470~698 MHz
AXT 631
分配出力
RF入力
AXT630
AXT 630
カスケード出力
Wideband
470~698 MHz
Band G1
470~530 MHz
Band H4
518~578 MHz
Band J5
578~638 MHz
Band L3
638~698 MHz
Wideband
606~814 MHz
Band K4E
606~666 MHz
Band M8
666~730 MHz
Band P8, P9
710~790 MHz
Band Q5
740~814 MHz
Wideband
470~787 MHz
Band G7C
470~510 MHz
Band L3E
638~698 MHz
Band M8
666~730 MHz
コネクターの種
BNC (1ペア)
構成
アンバランス、広帯域
インピーダンス
50 Ω
挿入損失
<5dB
ネットワーク
パワーオーバーイーサネット (PoE)
50 V DC, クラス1
ネットワークインターフェース
デュアルポートイーサネット 10/100 Mbps
ネットワークアドレス容量
DHCPまたはマニュアルIPアドレス
Band P9
710~787 MHz
インピーダンス
50 Ω
バイアス電圧
12 V DC, 150 mA (300 mA 最大)
18
AXT 630/ AXT631 Circuit Diagram
Antenna In
Cascade Out
50 Ω
Distro Out 1
50 Ω
0 dB
Distro Out 2
50 Ω
-3.5 dB
() Denotes gain when cascade is disabled
Distro Out 3
-15 dB to 0 dB
(-12 dB to +3 dB)
Distro Out 4
50 Ω
50 Ω
-15 dB to 0 dB
(-12 dB to +3 dB)
Passive Splitter
50 Ω
-15 dB to 0 dB
(-12 dB to +3 dB)
-15 dB to 0 dB
(-12 dB to +3 dB)
Passive Splitter
(Cascade Bypass)
Filter Select Switch
-3.5 dB
Filter Select Switch
Filter 1
Passive Splitter
Filter 2
Filter 3
Filter 4
User Gain Adjust
Passive Splitter
Wide Band
AXT630/AXT631/AXT632 Circuit Diagram
認証
AXT630、AXT63、AXT632
次の欧州指令の必須要件を満たします:
• R&TTE指令99/5/EC
• 欧州規制(EC)1275/2008(改正)に適合。
• WEEE指令2002/96/EC(2008/34/EC改正)
• RoHS指令2002/95/EC(2008/35/EC改正)
注: 電池および電子廃棄物については地域のリサイクル方法に従ってください
次の基準の要件を満たします。 EN 300 422第1部、第2部, EN 301,489第1部、第9部, EN60065.
EN 300 422第1部、第2部. EN 301,489第1部、第9部. EN60065.
AXT630
FCC規則第15章の適合宣言(DoC)規定により認可。
カナダ産業省RSS-123適合。
本クラスBデジタル機器はCanadian ICES-003に適合しています。Cet appareil numérique de la classe B est conforme à la norme NMB-003 du Canada.
このデバイスは、カナダ産業省ライセンス免除RSS基準に適合しています。
ユーザーの方へのお知らせ
本機器はテストされFCC規定パート15に従いクラスBデジタル機器に適合しますが、制限があります。これらの制限は、住宅地域において設置する
際、有害な電波干渉から機器を適度に保護するためのものです。本機器は電磁波を発生・使用し、放射する場合があります。取扱説明書に従って設置
しないと無線通信に電波干渉が起こります。また、設置状況に関わらず妨害を引き起こす可能性もあります。本機器によりラジオやテレビの受信に電
波干渉が起こるようであれば(これは、機器の電源を一度切ってから入れるとわかります)、次の手段を1つまたは複数用いて電波干渉を防いでくだ
さい。
• 受信アンテナを別の方向に向けるか、別の場所に移す。
• 機器と受信機の設置間隔を広げる。
• 受信機を接続しているコンセントとは別の回路にあるコンセントに機器を接続する。
• 販売店または熟練したラジオ/テレビ技術者に相談する。
注: EMC 適合性試験は同梱および推奨のケーブル使用に基づきます。別種のケーブルを使用した場合はEMC性能が低下します。
本機器の変更・改造を行うと、メーカーによって適合性が書面で認可されたものを除き、装置を使用するユーザーの権限が無効になる場合がありま
す。
CE適合宣言書はShure社またはShure社の欧州担当部より入手することができます。問い合わせ先についてはvisit www.shure.comを参照してください
CE適合宣言書は以下より入手可能です:www.shure.com/europe/compliance
ヨーロッパ認可代理店:
Shure Europe GmbH
ヨーロッパ、中東、アフリカ地区本部:
部門:EMEA承認
Jakob-Dieffenbacher-Str. 12
75031 Eppingen, Germany
Tel: 49-7262-92 49 0
Fax: 49-7262-92 49 11 4
Eメール: [email protected]
19
United States, Canada, Latin
America, Caribbean:
Shure Incorporated
5800 West Touhy Avenue
Niles, IL 60714-4608 USA
Phone: 847-600-2000
Fax: 847-600-1212 (USA)
Fax: 847-600-6446
Email: [email protected]
www.shure.com
©2013 Shure Incorporated
Europe, Middle East, Africa:
Shure Europe GmbH
Jakob-Dieffenbacher-Str. 12,
75031 Eppingen, Germany
Phone: 49-7262-92490
Fax: 49-7262-9249114
Email: [email protected]
Asia, Pacific:
Shure Asia Limited
22/F, 625 King’s Road
North Point, Island East
Hong Kong
Phone: 852-2893-4290
Fax: 852-2893-4055
Email: [email protected]
Fly UP