Comments
Description
Transcript
Untitled - Asahi Spectra USA Inc.
MAX-303 Technical Information MAX-303 UV (250-385nm) Light Guide (Quartz) *Please regard the following data as a reference. Measuring Condition Relative Spectral Sensitivity Sensitivity of Detector 100 80 60 40 20 0 Quartz Light Guide φ5mmx1m Irradiation Distance S254 S365 200 300 Detector A.Accumulated UV Power Meter UIT-150 S254(Ushio) B.Accumulated UV Power Meter UIT-150 S365(Ushio) C.Power Meter MODEL2835C (Newport) 400 Wavelength(nm) Xenon Light Source MAX-303 ・UV Lamp ・UV Mirror Module Relati Spectral Distribution 1 This graph shows the spectral distribution of MAX-303 with UV Lamp and UV Mirror Module measured by fiber spectrometer. Spectral Irradiance (Relative Value) 0.8 0.6 0.4 0.2 0 250 300 350 400 Wavelength(nm) 450 500 Illuminated Area & Center Illuminance at Different Distance Irradiance(mW/㎝2) A B Detector Distance 10mm 20mm 30mm 40mm 50mm 60mm 70mm 80mm 90mm 100mm Filter --- Illuminated area φ9mm φ13mm φ18mm φ24mm φ30mm φ35mm φ40mm φ45mm φ50mm φ53mm 664.00 309.00 160.00 95.50 63.10 44.60 32.60 25.10 19.70 16.00 --- Irradiance(mW/㎝2) C XHQA254 XHQA320 XHQA380 1699.00 700.00 342.00 196.00 128.00 90.10 65.40 50.10 39.60 32.10 Reference for XHQA (Bandpass Filter) http://www.asahi-spectra.com/opticalfilters/bandpass_filter.html 1 ----9.10 6.74 4.91 3.75 2.89 2.30 1.87 1.54 ----33.90 24.90 18.20 13.60 10.50 8.37 6.82 5.60 ----36.70 27.10 20.00 15.10 11.70 9.34 7.64 6.29 MAX-303 Technical Information MAX-303 UV (250-385nm) Light Guide Collimator Lens (Quartz) (x 1.0) *Please regard the following data as a reference. Measuring Condition Collimator Lens Quartz Light Guide x 1.0 φ5mmx1m Relative Spectral Sensitivity Sensitivity of Detector Irradiation Distance S254 100 80 60 40 20 0 S365 200 300 Detector A.Accumulated UV Power Meter UIT-150 S254(Ushio) B.Accumulated UV Power Meter UIT-150 S365(Ushio) C.Power Meter MODEL2835C (Newport) 400 Wavelength(nm) Xenon Light Source MAX-303 ・UV Lamp ・UV Mirror Module Spectral Distribution Spectral Irradiance (Relative Value) 1 This graph shows the spectral distribution of MAX-303 with UV Lamp and UV Mirror Module measured by fiber spectrometer. 0.8 0.6 0.4 0.2 0 250 300 350 400 450 500 Wavelength (nm) Illuminated Area & Center Illuminance at Different Distance Irradiance(mW/㎝2) A B Detector Filter Illuminated area 19 x 19mm 80mm 100mm 23 x 23mm 200mm 44 x 44mm 300mm 64 x 64mm 400mm 85 x 85mm 500mm 106 x 106mm 600mm 126 x 126mm 1000mm 208 x 208mm Distance --35.10 24.00 6.83 3.16 1.82 1.19 0.83 0.29 --- Irradiance(mW/㎝2) C C C XHQA254 XHQA320 XHQA380 73.00 49.50 13.80 6.42 3.69 2.42 1.69 0.59 Reference for XHQA (Bandpass Filter) http://www.asahi-spectra.com/opticalfilters/bandpass_filter.html 2 2.13 1.49 0.48 0.23 0.13 0.09 0.06 0.02 7.92 5.44 1.65 0.78 0.46 0.30 0.21 0.08 8.99 6.21 1.88 0.90 0.53 0.35 0.24 0.09 MAX-303 Technical Information MAX-303 VIS (385-740nm) Light Guide (Quartz) *Please regard the following data as a reference. Measuring Condition QuartzQuartz Light Guide Collimator 石英ファイバー Lens Lightguide φ5mmx1m 1.0倍 φ5×1m φ5×1m Sensitivity of Detector Spectral irradiance Relative Spectral 相対分光感度 (Relative Value) Sensitivity Sensitivity Characteristics of ディテクタの感度特性 T-10M 100 Detector 100 80 100 60 80 60 40 40 20 20 00 S25 4 S25 S36 4 5 S36 5 80 60 40 20 200 200 300 400 500 600 700 800 400 500 600 700 800 0 300 300 400Wavelength(nm) 500 600 700 800 900 波長(nm) Wavelength(nm) irradiation Distance Irradiation Distance 照射距離 Detector ディテクタ Detector A.高速分光ユニット A.High-resolution Spectrometer HSU-100S (朝日分光製) HSU-100S (Asahi Spectra) A.Illuminance Meter T-10M Minolta) B.紫外線積算光量計 B.Accumulated UV actinometer UIT-150(Konica S254/S365(ウシオ電機製) UIT-150 S254/S365(Ushio Inc) B.Power Meter MODEL2835C (Newport) C.Light Meter T-1M (Konica Minolta) C.照度計 T-1M (ミノルタ製) D.パワーメーター D.Power Meter MODEL2835C MODEL2835C (New (ニューポート製) Port) Xenon LightLight Source MAX-303 Xenon Source MAXキセノン光源 MAX-302 ・UV 302 Lamp ・UVランプ ・VISミラーモジュール ・VIS・UV Mirror Module Lamp Spectral Distribution This graph shows the spectral distribution of MAX-303 with UV Lamp and VIS Mirror Module measured by fiber spectrometer. 0.8 0.6 0.4 0.2 0 300 400 500 600 700 800 900 Wavelength (nm) Illuminated Area & Center Illuminance at Different Distance Detector Distance 10mm 20mm 30mm 40mm 50mm 60mm 70mm 80mm 90mm 100mm Center Illuminance(lx) A Irradiance(mW/㎝2) B --- XBPA400 XBPA550 XBPA700 Filter Illuminated area φ9mm φ13mm φ18mm φ24mm φ30mm φ35mm φ40mm φ45mm φ50mm φ53mm 10,253,000 6,897,000 4,474,000 2,983,000 2,051,000 1,491,000 1,137,000 895,000 713,000 583,000 ----40.00 27.80 19.50 14.40 10.90 8.55 6.93 5.79 ----51.80 36.30 25.50 18.90 14.30 11.30 9.12 7.63 ----41.00 28.90 20.30 15.10 11.40 9.02 7.28 6.11 Reference for XBPA (Bandpass Filter) http://www.asahi-spectra.com/opticalfilters/bandpass_filter.html Uniformity of Irradiation Distance: 20mm Distance: 50mm 90-100 80-90 70-80 80-90 70-80 70-80 60-70 -18 50-60 -30 50-60 -7 40-50 -12 40-50 3 24 42 -42 0-10 -28 10-20 0 26 20-30 -14 15 6 14 10-20 30-40 42 4 -10 20-30 0-10 90-100 80-90 28 30-40 -19 10 -10 -2 -6 6 2 6 40-50 8 2 50-60 -1 -2 Distance: 100mm 90-100 60-70 26 -6 60-70 17 -10 10 Spectral Irradiance (Relative Value) 1 30-40 20-30 10-20 0-10 MAX-303 Technical Information MAX-303 VIS (385-740nm) Light Guide Collimator Lens (Quartz) (x 1.0) *Please regard the following data as a reference. Measuring Condition Sensitivity of Detector Relative Spectral Sensitivity 相対分光感度 相対分光感度 ディテクタの感度特性 ディテクタの感度特性 100 Collimator Lens Quartz Light Guide ロッドレンズ 石英ファイバー 石英ファイバー x 1.0 φ5mmx1m 1.0倍 φ5×1m φ5×1m Irradiation Distance 照射距離 照射距離 T-10M S25 S25 80 100 100 44 80 80 S36 S36 60 60 60 55 40 40 40 20 20 20 00 0 200 200 300 300 400 400 500 500 600 600 700 700 800 800 300 400 500 600 700 800 900 波長(nm) 波長(nm) Wavelength(nm) ディテクタ Detector A.高速分光ユニット HSU-100S (朝日分光製) A.Illuminance Meter T-10M (Konica Minolta) B.紫外線積算光量計 UIT-150 S254/S365(ウシオ電機製) B.Power Meter MODEL2835C (Newport) C.照度計 T-1M (ミノルタ製) D.パワーメーター MODEL2835C (ニューポート製) Xenon キセノン光源 Light Source MAX-303 MAX-302 ・UV Lamp ・UVランプ ・VISミラーモジュール ・VIS Mirror Module Spectral Distribution This graph shows the spectral distribution of MAX-303 with UV Lamp and VIS Mirror Module measured by fiber spectrometer. 0.8 0.6 0.4 0.2 0 300 400 500 600 700 Wavelength (nm) 800 900 Illuminated Area & Center Illuminance at Different Distance Detector Center Illuminance(lx) A Irradiance(mW/㎝2) B --- XBPA400 XBPA550 XBPA700 Filter Illuminated area 19 x 19mm 80mm 100mm 23 x 23mm 44 x 44mm 200mm 300mm 64 x 64mm 85 x 85mm 400mm 500mm 106 x 106mm 126 x 126mm 600mm 1000mm 208 x 208mm Distance 1,318,000 898,000 265,000 122,400 70,800 46,200 32,100 11,700 12.70 8.79 2.56 1.20 0.69 0.45 0.31 0.11 16.40 11.30 3.30 1.55 0.89 0.58 0.40 0.15 13.70 9.56 2.77 1.29 0.74 0.48 0.33 0.12 Reference for XBPA (Bandpass Filter) http://www.asahi-spectra.com/opticalfilters/bandpass_filter.html Uniformity of Irradiation Distance: 100mm 90-100 80-90 80-90 70-80 -24 70-80 60-70 -12 60-70 4 10-20 0-10 50-60 30-40 20-30 -16 24 60-70 40-50 28 30-40 -40 0-10 40-50 20-30 4 10-20 -8 12 12 30-40 50-60 60 40-50 -16 -12 -2 -7 13 0 70-80 -40 36 50-60 20-30 3 8 7 90-100 80-90 -6 1 Distance: 500mm 90-100 24 -5 Distance: 200m 14 -11 13 Spectral Irradiance (Relative Value) 1 60 10-20 0-10 MAX-303 Technical Information Comparison of Spectrum Irradiance[μW/(cm2・nm)] 7 6 UV Mirror Module VIS Mirror Module 5 UV-VIS Mirror Module IR Mirror Module 4 3 2 1 0 200 300 400 500 600 700 800 900 1000 1100 Note: 1200 Irradiated Area: 400 x 400mm Wavelength(nm) Lamp Start-Up Characteristics Relative Intensity (%) 120 110 100 90 80 70 0 1 2 3 4 5 6 7 8 9 10 Time (min) Lamp Fluctuation Relative Intensity(%) 103 102 101 100 99 98 Note: 97 0 30 60 90 120 150 180 The data was obtained Time (sec) with regulated power supply. Lamp Life Relative Intensity(%) 100 80 60 40 20 0 0 100 200 300 400 500 600 700 Continuous Lighting Time(hrs) 5 After 2 hours of turning on. 800 900 1000 *Product specifications are subject to change without notice. Gardenia Bldg. 4F, 2-13-1 Kamijujo, Kita-ku, Tokyo 114-0034 Japan TEL : +81-3-3909-1151 / FAX : +81-3-3909-1152 Email : [email protected] www.asahi-spectra.com 20150713.0000