...

Untitled - Asahi Spectra USA Inc.

by user

on
Category: Documents
3

views

Report

Comments

Transcript

Untitled - Asahi Spectra USA Inc.
MAX-303 Technical Information
MAX-303
UV
(250-385nm)
Light Guide
(Quartz)
*Please regard the following data as a reference.
Measuring Condition
Relative Spectral
Sensitivity
Sensitivity of Detector
100
80
60
40
20
0
Quartz Light Guide
φ5mmx1m
Irradiation Distance
S254
S365
200
300
Detector
A.Accumulated UV Power Meter UIT-150 S254(Ushio)
B.Accumulated UV Power Meter UIT-150 S365(Ushio)
C.Power Meter MODEL2835C (Newport)
400
Wavelength(nm)
Xenon Light Source MAX-303
・UV Lamp
・UV Mirror Module
Relati
Spectral Distribution
1
This graph shows the spectral distribution of
MAX-303 with UV Lamp and UV Mirror
Module measured by fiber spectrometer.
Spectral Irradiance
(Relative Value)
0.8
0.6
0.4
0.2
0
250
300
350
400
Wavelength(nm)
450
500
Illuminated Area & Center Illuminance at Different Distance
Irradiance(mW/㎝2)
A
B
Detector
Distance
10mm
20mm
30mm
40mm
50mm
60mm
70mm
80mm
90mm
100mm
Filter
---
Illuminated area
φ9mm
φ13mm
φ18mm
φ24mm
φ30mm
φ35mm
φ40mm
φ45mm
φ50mm
φ53mm
664.00
309.00
160.00
95.50
63.10
44.60
32.60
25.10
19.70
16.00
---
Irradiance(mW/㎝2)
C
XHQA254 XHQA320 XHQA380
1699.00
700.00
342.00
196.00
128.00
90.10
65.40
50.10
39.60
32.10
Reference for XHQA (Bandpass Filter)
http://www.asahi-spectra.com/opticalfilters/bandpass_filter.html
1
----9.10
6.74
4.91
3.75
2.89
2.30
1.87
1.54
----33.90
24.90
18.20
13.60
10.50
8.37
6.82
5.60
----36.70
27.10
20.00
15.10
11.70
9.34
7.64
6.29
MAX-303 Technical Information
MAX-303
UV
(250-385nm)
Light Guide Collimator Lens
(Quartz)
(x 1.0)
*Please regard the following data as a reference.
Measuring Condition
Collimator Lens Quartz Light Guide
x 1.0
φ5mmx1m
Relative Spectral
Sensitivity
Sensitivity of Detector
Irradiation Distance
S254
100
80
60
40
20
0
S365
200
300
Detector
A.Accumulated UV Power Meter UIT-150 S254(Ushio)
B.Accumulated UV Power Meter UIT-150 S365(Ushio)
C.Power Meter MODEL2835C (Newport)
400
Wavelength(nm)
Xenon Light Source MAX-303
・UV Lamp
・UV Mirror Module
Spectral Distribution
Spectral Irradiance
(Relative Value)
1
This graph shows the spectral distribution of
MAX-303 with UV Lamp and UV Mirror Module
measured by fiber spectrometer.
0.8
0.6
0.4
0.2
0
250
300
350
400
450
500
Wavelength (nm)
Illuminated Area & Center Illuminance at Different Distance
Irradiance(mW/㎝2)
A
B
Detector
Filter
Illuminated area
19 x 19mm
80mm
100mm
23 x 23mm
200mm
44 x 44mm
300mm
64 x 64mm
400mm
85 x 85mm
500mm
106 x 106mm
600mm
126 x 126mm
1000mm
208 x 208mm
Distance
--35.10
24.00
6.83
3.16
1.82
1.19
0.83
0.29
---
Irradiance(mW/㎝2)
C
C
C
XHQA254 XHQA320 XHQA380
73.00
49.50
13.80
6.42
3.69
2.42
1.69
0.59
Reference for XHQA (Bandpass Filter)
http://www.asahi-spectra.com/opticalfilters/bandpass_filter.html
2
2.13
1.49
0.48
0.23
0.13
0.09
0.06
0.02
7.92
5.44
1.65
0.78
0.46
0.30
0.21
0.08
8.99
6.21
1.88
0.90
0.53
0.35
0.24
0.09
MAX-303 Technical Information
MAX-303
VIS
(385-740nm)
Light Guide
(Quartz)
*Please regard the following data as a reference.
Measuring Condition
QuartzQuartz
Light Guide
Collimator 石英ファイバー
Lens
Lightguide
φ5mmx1m
1.0倍
φ5×1m
φ5×1m
Sensitivity of Detector
Spectral
irradiance
Relative
Spectral
相対分光感度
(Relative
Value)
Sensitivity
Sensitivity
Characteristics of
ディテクタの感度特性
T-10M
100
Detector
100
80
100
60
80
60
40
40
20
20
00
S25
4
S25
S36
4
5
S36
5
80
60
40
20
200
200
300
400
500
600
700
800
400
500
600
700
800
0 300
300 400Wavelength(nm)
500 600 700 800 900
波長(nm)
Wavelength(nm)
irradiation
Distance
Irradiation
Distance
照射距離
Detector
ディテクタ
Detector
A.高速分光ユニット
A.High-resolution
Spectrometer
HSU-100S (朝日分光製)
HSU-100S (Asahi Spectra)
A.Illuminance
Meter
T-10M
Minolta)
B.紫外線積算光量計
B.Accumulated
UV actinometer
UIT-150(Konica
S254/S365(ウシオ電機製)
UIT-150
S254/S365(Ushio Inc)
B.Power
Meter
MODEL2835C
(Newport)
C.Light
Meter
T-1M
(Konica Minolta)
C.照度計
T-1M
(ミノルタ製)
D.パワーメーター
D.Power
Meter MODEL2835C
MODEL2835C
(New
(ニューポート製)
Port)
Xenon
LightLight
Source
MAX-303
Xenon
Source
MAXキセノン光源
MAX-302
・UV 302
Lamp
・UVランプ
・VISミラーモジュール
・VIS・UV
Mirror
Module
Lamp
Spectral Distribution
This graph shows the spectral distribution of
MAX-303 with UV Lamp and VIS Mirror
Module measured by fiber spectrometer.
0.8
0.6
0.4
0.2
0
300
400
500
600
700
800
900
Wavelength (nm)
Illuminated Area & Center Illuminance at Different Distance
Detector
Distance
10mm
20mm
30mm
40mm
50mm
60mm
70mm
80mm
90mm
100mm
Center Illuminance(lx)
A
Irradiance(mW/㎝2)
B
---
XBPA400 XBPA550 XBPA700
Filter
Illuminated area
φ9mm
φ13mm
φ18mm
φ24mm
φ30mm
φ35mm
φ40mm
φ45mm
φ50mm
φ53mm
10,253,000
6,897,000
4,474,000
2,983,000
2,051,000
1,491,000
1,137,000
895,000
713,000
583,000
----40.00
27.80
19.50
14.40
10.90
8.55
6.93
5.79
----51.80
36.30
25.50
18.90
14.30
11.30
9.12
7.63
----41.00
28.90
20.30
15.10
11.40
9.02
7.28
6.11
Reference for XBPA (Bandpass Filter)
http://www.asahi-spectra.com/opticalfilters/bandpass_filter.html
Uniformity of Irradiation
Distance: 20mm
Distance: 50mm
90-100
80-90
70-80
80-90
70-80
70-80
60-70
-18
50-60
-30
50-60
-7
40-50
-12
40-50
3
24
42
-42
0-10
-28
10-20
0
26
20-30
-14
15
6
14
10-20
30-40
42
4
-10
20-30
0-10
90-100
80-90
28
30-40
-19
10
-10
-2
-6
6
2
6
40-50
8
2
50-60
-1
-2
Distance: 100mm
90-100
60-70
26
-6
60-70
17
-10
10
Spectral Irradiance
(Relative Value)
1
30-40
20-30
10-20
0-10
MAX-303 Technical Information
MAX-303
VIS
(385-740nm)
Light Guide Collimator Lens
(Quartz)
(x 1.0)
*Please regard the following data as a reference.
Measuring Condition
Sensitivity of Detector
Relative Spectral Sensitivity
相対分光感度
相対分光感度
ディテクタの感度特性
ディテクタの感度特性
100
Collimator Lens Quartz Light Guide
ロッドレンズ
石英ファイバー
石英ファイバー
x 1.0
φ5mmx1m
1.0倍 φ5×1m
φ5×1m
Irradiation
Distance
照射距離
照射距離
T-10M
S25
S25
80
100
100
44
80
80
S36
S36
60
60
60
55
40
40
40
20
20
20
00
0 200
200 300
300 400
400 500
500 600
600 700
700 800
800
300 400 500 600 700 800 900
波長(nm)
波長(nm)
Wavelength(nm)
ディテクタ
Detector
A.高速分光ユニット HSU-100S (朝日分光製)
A.Illuminance Meter T-10M (Konica Minolta)
B.紫外線積算光量計 UIT-150 S254/S365(ウシオ電機製)
B.Power Meter MODEL2835C (Newport)
C.照度計 T-1M (ミノルタ製)
D.パワーメーター MODEL2835C (ニューポート製)
Xenon キセノン光源
Light Source MAX-303
MAX-302
・UV Lamp
・UVランプ
・VISミラーモジュール
・VIS Mirror
Module
Spectral Distribution
This graph shows the spectral distribution of
MAX-303 with UV Lamp and VIS Mirror
Module measured by fiber spectrometer.
0.8
0.6
0.4
0.2
0
300
400
500
600
700
Wavelength (nm)
800
900
Illuminated Area & Center Illuminance at Different Distance
Detector
Center Illuminance(lx)
A
Irradiance(mW/㎝2)
B
---
XBPA400 XBPA550 XBPA700
Filter
Illuminated area
19 x 19mm
80mm
100mm
23 x 23mm
44 x 44mm
200mm
300mm
64 x 64mm
85 x 85mm
400mm
500mm
106 x 106mm
126 x 126mm
600mm
1000mm
208 x 208mm
Distance
1,318,000
898,000
265,000
122,400
70,800
46,200
32,100
11,700
12.70
8.79
2.56
1.20
0.69
0.45
0.31
0.11
16.40
11.30
3.30
1.55
0.89
0.58
0.40
0.15
13.70
9.56
2.77
1.29
0.74
0.48
0.33
0.12
Reference for XBPA (Bandpass Filter)
http://www.asahi-spectra.com/opticalfilters/bandpass_filter.html
Uniformity of Irradiation
Distance: 100mm
90-100
80-90
80-90
70-80
-24
70-80
60-70
-12
60-70
4
10-20
0-10
50-60
30-40
20-30
-16
24
60-70
40-50
28
30-40
-40
0-10
40-50
20-30
4
10-20
-8
12
12
30-40
50-60
60
40-50
-16
-12
-2
-7
13
0
70-80
-40
36
50-60
20-30
3
8
7
90-100
80-90
-6
1
Distance: 500mm
90-100
24
-5
Distance: 200m
14
-11
13
Spectral Irradiance
(Relative Value)
1
60
10-20
0-10
MAX-303 Technical Information
Comparison of Spectrum
Irradiance[μW/(cm2・nm)]
7
6
UV Mirror Module
VIS Mirror Module
5
UV-VIS Mirror Module
IR Mirror Module
4
3
2
1
0
200
300
400
500
600
700
800
900
1000
1100
Note:
1200
Irradiated Area: 400 x 400mm
Wavelength(nm)
Lamp Start-Up Characteristics
Relative Intensity (%)
120
110
100
90
80
70
0
1
2
3
4
5
6
7
8
9
10
Time (min)
Lamp Fluctuation
Relative Intensity(%)
103
102
101
100
99
98
Note:
97
0
30
60
90
120
150
180
The data was obtained
Time (sec)
with regulated power supply.
Lamp Life
Relative Intensity(%)
100
80
60
40
20
0
0
100
200
300
400
500
600
700
Continuous Lighting Time(hrs)
5
After 2 hours of turning on.
800
900
1000
*Product specifications are subject to change without notice.
Gardenia Bldg. 4F, 2-13-1 Kamijujo, Kita-ku, Tokyo 114-0034 Japan
TEL : +81-3-3909-1151 / FAX : +81-3-3909-1152
Email : [email protected]
www.asahi-spectra.com
20150713.0000
Fly UP