OPERATOR'S MANUAL
SHIP SECURITY
ALERT SYSTEM (SSAS)
Model
IC-307
(For FELCOM 15/16/18/19)
www.furuno.com
The paper used in this manual
is elemental chlorine free.
・FURUNO Authorized Distributor/Dealer
9-52 Ashihara-cho,
Nishinomiya, 662-8580, JAPAN
All rights reserved.
Printed in Japan
A : MAY 2004
G : JAN . 23, 2015
Pub. No. OME-56351-G
( GREG )
IC-307(SSAS)
0 0 0 1 5 0 3 5 9 1 6
TABLE OF CONTENTS
SYSTEM CONFIGURATION ..................................................................................... ii
1. OVERVIEW OF SSAS .......................................................................................... 1
2. INSTALLATION .................................................................................................... 3
2.1 Mounting ........................................................................................................................... 3
2.1.1 Junction box (for FELCOM 16/FELCOM 19) ........................................................... 3
2.1.2 SSAS alert unit ......................................................................................................... 4
2.2 Wiring................................................................................................................................ 6
2.2.1 Junction box (for FELCOM 16/19) ........................................................................... 6
2.2.2 SSAS alert unit ......................................................................................................... 7
2.3 Initial Settings ................................................................................................................... 8
3. OPERATION ......................................................................................................... 9
3.1 Operation Mode ................................................................................................................ 9
3.1.1 Changing the password............................................................................................ 9
3.1.2 SSAS manager mode ............................................................................................ 10
3.2 Setting SSAS Report Destination and Message Contents .............................................. 11
3.3 Transmitting SSAS Report .............................................................................................. 14
3.4 Testing the Button ........................................................................................................... 16
3.5 SSAS Report Test ........................................................................................................... 21
4. WATERPROOFING KIT (OPTION) .................................................................... 22
OUTLINE DRAWINGS........................................................................................... D-1
INTERCONNECTION DIAGRAMS .........................................................................S-1
i
SYSTEM CONFIGURATION
Regulations require at least two SSAS alert units.
FELCOM 15
ANTENNA
UNIT
IC-115
DGPS
100-115/200-230 VAC
1, 50/60 Hz
AC-DC Power Supply
PR-240-CE*1
24 VDC
EGC Printer
PP-50
TERMINAL UNIT
IC-215
Personal
Computer
(PC/AT compatible)
GPS receiver
OP16-24
12/24 VDC
24 VDC
Printer
Shipboard LAN (Ethernet)
Printer
PP-510
24 VDC
Mini Keyboard
SSAS Alert Unit
IC-307
Distress Alert/
Received Call Unit
IC-305
SSAS Alert Unit
IC-307
JUNCTION
BOX
IC-315
(Max. 3 units)
SSAS Alert Unit
IC-307
Alarm Unit
IC-306
Navigator
: Standard Supply
: Option
: Local Supply
*1 Any AC-DC power supply
fulfilling requirements of
IEC 60945 may be used.
FELCOM 16
ANTENNA
UNIT
IC-116
PRINTER
O
SSAS Alert Unit
IC-307
POWER
ii
R
RO
IN
G
I
SSAS Alert Unit
IC-307
(Max. 3 units)
LO
12/24 VDC
SSAS Alert Unit
IC-307
INMARSAT MINI-C MOBILE EARTH STATION
PO
W
FURUNO
ER
COMMUNICATION UNIT IC-216
(with internal GPS receiver)
ER
24 VDC
AC-DC
Power Supply
PR-240-CE
TX
100-115/200-230 VAC
1, 50/60 Hz
JUNCTION BOX
IC-315
PERSONAL
COMPUTER
(PC/AT compatible)
: Standard
: Option
: Local Supply
FELCOM 18
FELCOM 19
ANTENNA
UNIT
IC-119
AC-DC
Power Supply
PR-240
SHIP'S MAINS
12-24 VDC
PERSONAL
COMPUTER
(Windows OS)
COMMUNICATION UNIT IC-219
(with internal GPS receiver)
JUNCTION BOX
IC-318
SSAS ALERT UNIT
IC-307*
SSAS ALERT UNIT
IC-307*
iii
* At least two SSAS Alert Units
are required.
NAVIGATOR
(GLONASS
compliant)
1. OVERVIEW OF SSAS
The IC-307 SSAS (Ship Security Alert System) Alert Unit connects to the Inmarsat-C MES
FELCOM 15/FELCOM 18 or the Inmarsat Mini-C FELCOM 16/FELCOM 19 for the purpose
of alerting specified addresses (for example, your ship’s company) that your ship is under
attack by intruders. The SOLAS Resolution XI-2/6 requires vessels of 500 GT or more
constructed before 01 July 2004 to install an SSAS.
When your ship is under attack an SSAS report, which contains your ship’s name, MMSI
No., position, etc. is sent to up to five locations, specified by the ship’s captain or authorized
personnel. No audible or visible alarm is generated while the SSAS report is being
transmitted, to prevent discovery of the report by the intruders.
The SSAS is protected with a password to prevent unauthorized setting or testing of it by
other than the ship’s captain or authorized personnel.
Inmarsat System
Ship Name, MMSI No.,
Ship Position, etc.
Headquarters
Ship
Ship's Company,
Management Company
1
SSAS operation flow
1. Open the cover of the button and then press the button.
(This is a latch-type button; hit and release to activate the button.)

2. If addresses have been preset, the SSAS report is sent to one
address 30 seconds after the button is activated.
(Max. 5 addresses)
(You may cancel transmission of the SSAS report by pressing the
button again within 30 seconds of the initial press.)

3. An LES sends acknowledgement to your ship.
4. Steps 2-3 and are repeated in case of multiple addressees.

5. Continuous transmission of the SSAS report begins.
(The interval at which to transmit the SSAS report to each address
can be specified. The SSAS report is continuously transmitted
while the button is ON, at the interval selected.)

6. To stop transmission, press the button again to deactivate it.
(This is only possible in the SSAS manager mode. See
paragraph 3.1.)
2
2. INSTALLATION
2.1 Mounting
2.1.1 Junction box (for FELCOM 16/FELCOM 19)
The junction box IC-315 is required when installing the SSAS on the FELCOM 16/FELCOM
19; it is already installed on the FELCOM 15/FELCOM 18.
Separate the junction box from a magnetic compass by the distances shown below to
prevent deviation to a magnetic compass.
IC-315
Standard compass: 1.0 m
Steering compass: 0.7 m
IC-318
Standard compass: 0.90 m
Steering compass: 0.60 m
1. Remove four screws from the unit to separate the cover from the unit.
2. Fix the unit to the mounting location with four self-tapping screws (4x16, supplied).
3. Connect the cables appropriately referring to paragraph 2.2.1.
120 0.5
70 0.5
Junction box IC-315/318
The junction box is connected to the communication unit with a 2 meter cable, with D-sub
connector (at the communication unit). Therefore, locate the junction box within two meters
of the communication unit.
3
2.1.2 SSAS alert unit
Separate the junction box from the SSAS alert unit by the distances shown below to prevent
deviation to a magnetic compass.
Standard compass: 0.70 m
Steering compass: 0.45 m
Locate the SSAS alert unit where it cannot be found by intruders. The location should be
known only by ship’s captain and authorized personnel.
Bulkhead mounting
1. Remove four screws from the unit to separate the bottom chassis from the top cover.
2. Fix the unit to the mounting location with four self-tapping screws (supplied).
3. The cable can be lead in from the bottom or the rear panel. For rear panel entrance,
change the clamp orientation as follows:
a) Unfasten three screws to remove the cable clamp.
b) Turn the clamp 90 degrees.
c) Refasten the clamp with three screws unfastened at step a) to fix the clamp.
Unfasten three screws.
Clamp
Turn
Fasten three screws.
4. Run the cable thru one of the cable entrances and connect it to terminal board.
4
5. Attach the switch cover as shown below. Note that the cover may also be rotated 180
degrees.
Press here and hold down for five seconds.
Switch cover
Flush mounting
The optional flush mount kit OP16-28 (Code No. 004-448-010) is required.
Name
Fixture
Pan head screw
Self-tapping screw
Type
Code No.
16-018-7201-1 100-317-931
M3x6
000-800-362
4x16
000-802-080
Qty
1
4
4
Remarks
1. Cut out the mounting position referring to the outline drawings at the back of this
manual.
2. Fix the unit to the fixture with four pan head screws (supplied).
3. Fasten the fixture with the unit to the mounting location with four self-tapping screws
(supplied).
4. Attach switch cover as shown above.
5
2.2 Wiring
2.2.1 Junction box (for FELCOM 16/19)
Use the junction box IC-315 to connect the SSAS alert unit to the FELCOM 16, or the
junction box IC-318 to connect the SSAS alert unit to the FELCOM 19. Unfasten four
screws to remove the cover to connect cables to terminal board. For detailed wiring
information see the interconnection diagram.
For connecting the SSAS alert unit IC-307, use the JIS cable TTYCS-4 (or equivalent, see
next page for sectional view of this cable) or the CO-SPEVV-SB-C 0.2x5P. When using the
CO-SPEVV-SB-C 0.2x5P cable, replace the cable clamp with the cable clamp
16-018-6008-1, supplied with the junction box. For connecting the communication unit
IC-216, use cable 16S0344.
1 Vcc
2 GND
3 TD/RD-A
4 TD/RD-B
5 NC
6 TD-A(NAV)
7 TD-B(NAV)
8 RD-A(NAV)
9 RD-B(NAV)
10 GND
11 DMC OUT-H
12 DMC OUT-C
13 DMC IN-H
14 DMC IN-C
15 DMC CTR
Cover
Cable clamp
(top)
Terminal
board
1 Vcc
2 GND
3 TD/RD-A
4 TD/RD-B
5 NC
6 ALM-H
7 ALM-C
8 RD-A(NAV)
9 RD-B(NAV)
10 GND
11 SSAS OUT-H
12 SSAS OUT-C
13 SSAS IN-H
14 SSAS IN-C
15 SSAS CTR
Communication
Unit
IC-305/306
IC-318
IC-305/306
IC-315
1
2
Cable clamp
(bottom)
Cable clamp
3
Fold back braided shield onto
sheath and fix by cable clamp.
16S0344
Core 7 mm
Procedure
1. Insert driver from direction 1 .
15mm
90mm
7mm
2. Tilt slightly toward 2 .
3. Insert cable core to 3 .
Connect the drain wire of the TTYCSLA cables
with the screw and crimp-on lugs provided.
Note 1: Do not insert the cable too
deeply, to prevent pinching the sheath.
Screw, crimp-on lug
(pre-fitted at factory)
Note 2: Pull each cable slightly to confirm that they are in their holes securely.
IC-318 (inside)
6
2.2.2 SSAS alert unit
Three SSAS alert units can be connected. For wiring, see the illustrations below and the
interconnection diagram at the back of this manual. For the terminal unit (FELCOM 15/18)
and the communication unit (FELCOM 16/19), the wiring of the SSAS is monitored and if in
error “TROUBLE: SSAS UNIT connection abnormality.” is displayed. Further the ERROR
lamp (FELCOM 16/19) flashes.
Junction
Box
IC-307
(No.1)
IC-307
(No. 3)
IC-307
(No. 2)
Connect wiring to the terminal board 16P0229 inside the SSAS unit. To differentiate
between units in case of multiple unit installation, change jumper block settings as shown
below, in accordance with how many units are installed.
Jumper settings for two IC-307
Unit No.1 unit*
No. 2 unit
Jumper
JP1
No
Yes
JP2
Yes
No
No. 1 unit: Unit with two cables connnected to it.
No. 2 unit: Unit with one cable connnected to it.
Two IC-307: No. 2
Three IC-307: No. 3
16P0229
JP1
Two IC-307: No. 1
Three IC-307: No. 1 and No. 2
16P0229
JP2
1 2
Jumper settings for three IC-307
No. 2 unit*
No. 3 unit
*: Default Jumper Unit No.1 unit*
setting JP1
No
No
Yes
JP2
Yes
Yes
No
No. 1 and No. 2 units: Units with two cables connnected to them.
No. 3 unit: Unit with one cable connnected to it.
JP1
3
4 5
IC-307
6
JP2
1 2
3
4 5
6
IC-307
Cable Fabrication
Twist shield.
Clamp for cable
CO-SPEVV-SB-C
0.2x5P
CO-SPEVV-SB-C 0.2X5P
or TTYCS-4
Cut and tape
unused wires
to prevent short.
15 mm 40 mm 10 mm
 = 16.3 mm
Clamp for cable
TTYCS-4
or equivalent
Armor
Sheath
Shield
Conductor
S = 0.75 mm2
 = 1.11 mm
Sectional view of cable TTYCS-4
7Wiring inside the SSAS alert unit
7
2.3 Initial Settings
Set up the SSAS as follows:
1. FELCOM 15: Press [F8], [2] to show the System Setup menu.
FELCOM 16/18/19: Press [F8], [1] to show the System Setup menu.
2. Press [↓] to choose Command Window and then press the [Enter] key.
Command Window
Command Window
[Main menu]
1. Remote Box Setup
2. External Alarm Setup
3. AMS Setup
4. Management Profile Setup
Enter JOB No.:
RFCONCPU ***
[ Main Menu ]
1. Remote Box Setup
2. Internal GPS Setup
Enter JOB No. :
FELCOM 15/16
FELCOM 18/19
3. Type “furunoservice” (without quotation marks) in the Enter JOB No. field and then press
the [Enter] key. The prompt PASSWORD appears.
4. Enter password (see FURUNO Information for SSAS) then press the [Enter] key. Then,
the item Main Menu is displayed in reverse video.
5. Press [1], [Enter], [1], [Enter]. One of the following windows appears.
6. Press [1], [Enter]. This enables the SSAS functions.
7. Press the [Esc] key several times to close the menu.
Note: Test the SSAS button and SSAS report for proper operation, referring to paragraphs
3.4 and 3.5, respectively.
8
3. OPERATION
3.1 Operation Mode
There are two menu operating modes:
Normal mode:
Menus other than SSAS-related menus are displayed.
SSAS manager mode: The mode is activated by the password entered by the ship’s
captain or authorized personnel. The indication “SSAS Manager
Mode” is shown at the top of the screen when this mode is
activated. All SSAS-related menus are available. Transmission of
the SSAS report may be cancelled in this mode. The equipment
starts up in the normal mode, regardless of the mode in use when
the power is turned off.
3.1.1 Changing the password
The default password is “ship security alert”. Ship’s captain or authorized personnel may
change the password as follows:
1. FELCOM 15: Press [F8], [2] to show the System Setup menu.
FELCOM 16/18/19: Press [F8], [1] to show the System Setup menu.
2. Press [↓] to choose Command Window and then press the [Enter] key.
Command Window
Command Window
[Main menu]
1. Remote Box Setup
2. External Alarm Setup
3. AMS Setup
4. Management Profile Setup
Enter JOB No.:
RFCONCPU ***
[ Main Menu ]
1. Remote Box Setup
2. Internal GPS Setup
Enter JOB No. :
FELCOM 15/16
FELCOM 18/19
3. On the Enter JOB No. field, type “ssas password” (without quotation marks) and then
press the [Enter] key. The prompt OLD PASSWORD appears.
4. Type your current password and then press the [Enter] key. The prompt NEW
PASSWORD appears.
5. Enter new password, using at least six characters, and then press the [Enter] key. The
prompt RETYPE NEW PASSWORD appears.
Note: If less than six characters are entered for the password, the message “Please
use a longer password.” appears. Enter a longer password.
6. Enter new password again and then press the [Enter] key. The message “Password
changed” appears.
7. Press the [Esc] key several times to close the menu.
Note: The SSAS manager mode cannot be unlocked without the proper password.
9
3.1.2 SSAS manager mode
All SSAS-related settings are set in the SSAS manager mode. Do the following to access
this mode.
1. FELCOM 15: Press [F8], [2] to show the System Setup menu.
FELCOM 16/18/19: Press [F8], [1] to show the System Setup menu.
2. Press [↓] to choose Command Window and then press the [Enter] key.
Command Window
Command Window
[Main menu]
1. Remote Box Setup
2. External Alarm Setup
3. AMS Setup
4. Management Profile Setup
Enter JOB No.:
RFCONCPU ***
[ Main Menu ]
1. Remote Box Setup
2. Internal GPS Setup
Enter JOB No. :
FELCOM 15/16
FELCOM 18/19
3. On the Enter JOB No. field, type “ssas manager” (without the quotation marks) and then
press the [Enter] key.
Note: If there is no SSAS equipment connected, the message "Command Ignored: No
SSAS button is installed." appears.
4. Type password and then press the [Enter] key to go into the “SSAS Manager Mode”.
The indication “SSAS Manager Mode” is shown at the top of the screen when this mode
is activated, and it is flashing.
CAUTION
04-04-20 05:37 (UTC)
SSAS Manager Mode enabled.
<Press ESC key to continue>
5. Press the [Esc] key several times to close the menu. This enables the SSAS manager
mode, which allows you to execute the procedure in paragraph 3.2.
Note: Turn the power off and on again whenever changing SSAS-related settings.
10
3.2 Setting SSAS Report Destination and
Message Contents
When the SSAS is activated, the SSAS report is sent according to the addresses (max. 10)
and message content set with SSAS Report 1 – SSAS Report 10 on the SSAS Report
menu.
Note 1: The destination and message content of an SSAS report varies according to
Administration. Therefore, set them as requested by ship’s authorities. For
information other than ship’s name, MMSI no. and IMN no., set it manually with
“Other Inf.”
Note 2: The equipment must be in the SSAS manager mode to execute this procedure.
See paragraph 3.1.2.
1. Press the [F5] to open the Reports menu.
Reports
Reports
1. Data Report
2. Message Report
3. Data Network ID
4. SSAS Report
1. Data Report
2. Message Report
3. Enhanced Pre-Assigned Data Report (EPADR)
4. Data Network ID
5. SSAS Report
FELCOM 15/16
FELCOM 18/19
2. For FELCOM15/19, press the [4] key to show the SSAS Report menu.
For FELCOM 18/19, press the [5] key.
SSAS Report
1. SSAS Report 1
2. SSAS Report 2
SSAS Report
1. SSAS Report Destination
2. Message Contents
3. SSAS Report 3
4. SSAS Report 4
5. SSAS Report 5
FELCOM 18/19
6. Message Contents
FELCOM 15/16
3. For FELCOM 15/16, press the appropriate report number ([1] through [5]) to show the
SSAS Report Destination menu.
For FELCOM 18/19, press the [1] key.
SSAS Report Desitnation
Enter: Report Entry ESC: Quit
No
01
02
03
04
05
06
07
Mode
Destination
Interval
Test Only test@test
00:10
Real+Test 123456789
02:00
Interval is displayed in the
hh:mm format.
Setting range: 00:10 to 99:59
Destination ID or mail address
08
09
10 Selected mode (Real+Test,
Real Only, Test Only) is
displayed here
The SSAS Report Destination menu displays any current reports.
11
4. Press the [↑] or [↓] key to choose the report number desired and then press the [Enter]
key to display the selected SSAS report’s details.
Status
Mode
Station Name
Destination Type
Prefix Code
Country/Ocean Code
Station ID
Modem Type
Address
Subject
LES ID
Report Interval
SSAS Report
ON
Real+Test
Status
Mode
Station Name
Destination Type
Prefix Code
Country/Ocean Code
Destination
Modem Type
Address
Subject
LES ID
Report Interval
TELEX
02:00 (hh: mm)
FELCOM 15/16
SSAS Report
ON
Real+Test
TELEX/MES
02:00
FELCOM 18/19
5. Press the [↓] key to choose Mode and then press the [Enter] key.
Real+Test
Real Only
Test Only
6. Press the [↑] or [↓] key to choose mode desired and then press the [Enter] key.
“Mode” defines what SSAS report(s) a station is to receive:
Real+Test: Actual SSAS report and test SSAS report.
Real Only: Actual SSAS report only.
Test Only: Test SSAS report only.
7. Press the [↓] key to choose Station Name and then press the [Enter] key.
8. Press the [↑] or [↓] key to choose appropriate station and then press the [Enter] key.
You may sort the list by group name, station name or communication type as follows:
Group name: Each press of [Ctrl] + [G] sorts the list by group name, ascending or
descending order.
Station name: Each press of [Ctrl] + [N] sorts the list by station name, in ascending or
descending order.
Comm. type: Each press of [Ctrl] + [T] sorts the list by communication type, in
ascending or descending order.
9. Press the [↓] key to choose LES ID and then press the [Enter] key.
10. Press the [↑] or [↓] key to choose LES and then press the [Enter] key.
Note: Change the LES whenever sea area has changed. However, the equipment
automatically searches for an LES with which you can communicate and the SSAS
report is transmitted to that LES.
11. Press the [↓] key to choose Report Interval and then press the [Enter] key.
12. Enter time interval (00:10-99:59) to transmit the SSAS report and then press the [Enter]
key.
13. Press the [Esc] key to show the Update window.
Update
Yes
No
14. Yes is selected; press the [Enter] key to close the SSAS report window.
12
15. Press the [2] key to display the SSAS Message Contents menu.
Vessel Name :
MMSI
:
IMN
:
Other Inf.
:
LAT:
LON:
Time:
COURSE:
SPEED:
Time:
SSAS Message Contents
______________________________
_________
_________
_______________________________________________________
_______________________________________________________
_______________________________________________________
34: 44. 46N
135: 21. 26E
02/04/2012 04:31:48 (UTC)
071 deg
00 kt
02/04/2012 04:31:48 (UTC)
FELCOM 15/16
SSAS Message Contents
_
_
_
_
_
_
_
_
_
_____________________
Vessel Name :
Call Sign
: _________
MMSI
: _________
IMN
: _________
IMO
: _________
Other Inf.
: ___________________________________________________
___________________________________________________
___________________________________________________
___________________________________________________
___________________________________________________
___________________________________________________
LAT:
34: 44. 46N
LON:
135: 21. 26E
Time:
02/04/2012 04:31:48 (UTC)
COURSE:
071 deg
SPEED:
00 kt
Time:
02/04/2012 04:31:48 (UTC)
FELCOM 18/19
16. Press the [Enter] key to open the Vessel Name window.
17. Enter vessel’s name and then press the [Enter] key.
18. Press the [↓] key to choose MMSI and then press the [Enter] key.
19. Enter MMSI number and then press the [Enter] key.
20. Press the [↓] key to choose IMN and then press the [Enter] key.
21. Enter IMN and then press the [Enter] key.
22. Press the [↓] key to choose Other Inf. and then press the [Enter] key
23. Enter appropriate message (for FELCOM15/16: three lines, for FELCOM18/19: six lines)
and then press the [Enter] key.
Note: To shift between lines, use the [↑] or [↓] key.
24. Press the [Esc] key to show the Update window.
25. Yes is selected; press the [Enter] key to close the SSAS Message Contents menu.
26. Press the [Esc] key twice to return to the standby display.
Note 1: To delete entered subscriber’s data, choose “Remove” from “Status.”
Note 2: SSAS report settings may be saved to a floppy disk for backup.
FELCOM 15: [F8], [9], [6] to show the Save/Load window.
FELCOM 16: [F8], [8], [6] to show the Save/Load window.
FELCOM 18/19: [F8], [8], [6] to show the Export/Import window.
13
Save to FD
1. ALL
2. Station List
3. LES List
4. E-Mail Service List
5. SSAS Report*
6. Other
Load from FD
1. ALL
2. Station List
3. LES List
4. E-Mail Service List
5. SSAS Report*
6. Other
*: Availlable only in SSAS manager mode
("5.SSAS Report" is added in the SSAS
manager mode and item numbers are shifted.)
FELCOM15/16
Export
1. Sent Message
2. Received Message
3. EGC Message
4. Station List
5. LES List
6. E-Mail/SMS Service List
7. Test
8. Maintenance
9. Settings
Import
1. Station List
2. LES List
3. E-Mail/SMS Service List
4. Settings
FELCOM 18/19
Note 3: To confirm the settings, follow paragraph 3.5.
3.3 Transmitting SSAS Report
In the normal mode, the SSAS report is sent 30 seconds after the button on the SSAS is
pressed. The SSAS repeatedly transmits the report even if the button is pushed off ( ).
Repeated transmission can only be stopped from the SSAS manager mode.
1. Open the cover of the SSAS alert button.
2. Push the button. The button is a latch-type button;
hit and release the button to activate ( ) the
SSAS unit.
3. The SSAS report is transmitted 30 seconds after
the button is pushed in ( ). Below are the
contents of the SSAS report.
- - - SSAS ALERT MESSAGE - - Vessel Name: Queen Elizabeth 2
MMSI:
111660000
IMN:
443100000
Help me!
LAT:
34:44.46N
LON:
135:21.26E
Time:
02/04/2004 04:31:48 (UTC)
COURSE:
071 deg
SPEED:
00 kt
Time:
02/04/2004 04:31:48 (UTC)
Ship's Name
MMSI No.
IMN No.
Desired message
Own ship postion in latitude
Own ship position in longitude
Time of position data
Course
Speed
Time of course and speed data
FELCOM 15/16
14
Cover
- - - SSAS ALERT MESSAGE - - Vessel Name: Queen Elizabeth 2
MMSI:
111660000
IMN:
443100000
IMO:
123456789
Help me!
LAT:
34:44.46N
LON:
135:21.26E
Time:
02/04/2004 04:31:48 (UTC)
COURSE:
071 deg
SPEED:
00 kt
Time:
02/04/2004 04:31:48 (UTC)
Ship's Name
MMSI No.
IMN No.
IMO No.
Desired message
Own ship postion in latitude
Own ship position in longitude
Time of position data
Course
Speed
Time of course and speed data
FELCOM 18/19
4.
5.
6.
7.
An LES sends acknowledgement to your ship.
For multiple destinations, steps 3 and 4 are repeated.
The SSAS report is transmitted repeatedly while the button remains pushed in ( ).
To stop transmission, push the button again to pop it out ( ). (SSAS manager mode
only.)
Note: If transmission is not canceled with the button and the power is turned off, the
equipment resumes repeated transmission when powered again.
How to cancel the transmission when the transmission is erroneously
made (FELCOM15/16/18/19)
Note 1: The SSAS report is sent 30 seconds after the button on the SSAS is pressed.
Note 2: The message shown below appears when the cancellation is made.
CAUTION
14-04-10 05:40 (UTC)
INF: SSAS UNIT activation has been canceled.
Pop-up message
<Within 30 seconds after the button is pressed>
Press the button on the SSAS again to turn it off.
<More than 30 seconds after the button is pressed>
[Method 1]
Note : Do the following procedure on the terminal unit of FELCOM15/18 or PC of
FELCOM16/19.
1. Switch to the SSAS manager mode, referring to paragraph 3.1.2.
2. In case of FELCOM16/18/19, press [F8], [1] to show the [System Setup] menu.
In case of FELCOM15, press [F8], [2] to show the [System Setup] menu.
3. Press [↓] to choose Command Window and then press the [Enter] key.
4. Type “terminate ssas alert” (without quotation marks) in the Enter JOB No. field and then
press the [Enter] key.
[Method 2]
1. Turn the button of all SSAS IC-307s off.
2. Press the button ON→OFF→ON→OFF on one of the above-mentioned SSAS IC-307s
15
3.4 Testing the Button
Note 1: An actual SSAS report cannot be transmitted during the testing.
Note 2: The equipment must be in the SSAS manager mode to conduct the test.
FELCOM 15/18
<In case of not sending the test report>
1. Press the [F7] key to display the Options menu.
2. Press one of the following keys to display the Test menu:
Operating mode is Inmarsat-C: [7] key
FELCOM 18: [8] key
Operating mode is EGC receiver: [6] key
Test
1. PV Test
2. PV Test Result
3. Diagnostic Test
4. Distress/SSAS Button Test
3. Press the [4] key.
Options
Test
1. Login
2.1.Logout
PV Test Distress/SSAS Button Test
3.2.Abort
PV Test Result
Start
4.3.Select
NCS
Self Test
5.4.Ocean
Region
Distress
Alarm Button Test
No
Yes
6. Test
4. Press the [Enter] key to start the test.
Options
Test
1. Login
2.1.Logout
PV Test Distress/SSAS Button Test
3.2.Abort
PV Test Result
4.3.Select
NCS
Distress/SSAS
buttons are under test mode.
Self
Test
CAUTION
5.4.Ocean
Region
Press
any key
to escape.
Distress
Alarm
Button
Test
INF: SSAS6.Buttons
Test entered into TEST MODE.
<Press ESC key to continue>
The display shows the message (in red) “Distress/SSAS buttons are under test. Cancel
the test mode if a real distress/SSAS needs to sent.” appears.
5. Open the button cover on the No.1 SSAS.
6. Push the button in ( ). The CAUTION window displays the message “SSAS UNIT
works correctly.” appears if the unit is functioning properly.
Turn the button of the No. 1 SSAS off (
) within 30 seconds.
Note: Any message does not appear when turning the button off.
7. Close the button cover on the No.1 SSAS.
Note: To test the No. 2 and No. 3 SSAS repeat steps 5 to 9.
16
8. To escape from the test, press the [Esc] key twice on the terminal unit. The test mode is
stopped and the message shown below appears to notify you that normal operation has
been restored.
CAUTION
INF: SSAS Buttons returned to NORMAL OPERATION.
<Press ESC key to continue>
If the button remains pushed in ( ), the message “Please return the SSAS button into
OFF-STATE.” appears. Push the button to pop it out.
9. Press the [Esc] key three times to return to the standby display.
Note:If the button is left pushed in ( ) when the terminal unit is turned on, the
equipment displays “Please return the SSAS button into OFF-STATE.” Push the button
again to turn off ( ) the button.
<In case of sending the test report>
1. Press the [F7] key to display the Options menu.
2. Press one of the following keys to display the Test menu:
Operating mode is Inmarsat-C: [7] key
FELCOM 18: [8] key
Operating mode is EGC receiver: [6] key
Test
1. PV Test
2. PV Test Result
3. Diagnostic Test
4. Distress/SSAS Button Test
3. Press the [4] key.
Options
Test
1. Login
2.1.Logout
PV Test Distress/SSAS Button Test
3.2.Abort
PV Test Result
Start
4.3.Select
NCS
Self Test
5.4.Ocean
Region
Distress
Alarm Button Test
No
Yes
6. Test
4. Press the [Enter] key to start the test.
Options
Test
1. Login
2.1.Logout
PV Test Distress/SSAS Button Test
3.2.Abort
PV Test Result
4.3.Select
NCS
Distress/SSAS
buttons are under test mode.
Self
Test
CAUTION
5.4.Ocean
Region
Press
any key
to escape.
Distress
Alarm
Button
Test
INF: SSAS6.Buttons
Test entered into TEST MODE.
<Press ESC key to continue>
The display shows the message (in red) “Distress/SSAS buttons are under test. Cancel
the test mode if a real distress/SSAS needs to sent.” appears.
17
5. Open the button cover on the No.1 SSAS.
6. Push the button in ( ). The CAUTION window displays the message “SSAS UNIT
works correctly.” appears if the unit is functioning properly.
7. 30 seconds after the button is pushed in the SSAS test report is automatically sent to
the station(s) whose Mode set on the SSAS Report window is “Real+Test” or Test Only”.
When starting the transmission, [Current State] indicates [SENDING] at the left bottom
on the screen.
Current State : SENDING
DCE F18 Ver.01
Returning
NCS:POR
LOGIN
REC. MESSAGE EXIST
94-08-11 10:11(UTC)
LAT: 10:00.00N
LON: 000:00.00E
Note: The SSAS test report is not sent to the station(s) whose Mode set on the SSAS
Report window is “Real Only”..
8. Turn the button of the No. 1 SSAS off ( )
9. Close the button cover on the No.1 SSAS.
Note: To test the No. 2 and No. 3 SSAS repeat steps 5 to 9.
10. To escape from the test, press the [Esc] key twice on the terminal unit. The test mode is
stopped and the message shown below appears to notify you that normal operation has
been restored.
CAUTION
INF: Distress/SSAS Buttons returned to NORMAL OPERATION.
<Press ESC key to continue>
If the button remains pushed in ( ), the message “Please return the SSAS button into
OFF-STATE.” appears. Push the button to pop it out.
11. Press the [Esc] key three times to return to the standby display.
Note:If the button is left pushed in ( ) when the terminal unit is turned on, the
equipment displays “Please return the SSAS button into OFF-STATE.” Push the button
again to turn off ( ) the button.
12. When the SSAS test report is successfully sent, “Successful Sending message” and
“DELIVERY CONFIRMED:A specified email address” messages are shown below.
CAUTION
94-08-11 00:38(UTC)
Successful Sending message.
94-08-11 00:41(UTC)
DELIVERY CONFIRMED: [email protected]
<Press ESC key to continue>
13. Confirm that the SSAS test report is sent to the station(s).
18
FELCOM 16/19 (no PC)
Turn off communication unit.
Turn on button of No. 1 SSAS.
Turn on communication unit.
30 s
POWER, LOGIN and TX lamps flash
in that order.
Send SSAS
test report?
No (within 30 s)
Yes (after 30 s)
SSAS report is sent to station(s)
whose mode is "Real+Test" or "Test
Only". (See paragraph 3.2.)
Lamps flash rapidly during TX. It takes
2 to 5 minutes to send one message.
Test
successful?
Test TX
No ERROR lamp flashes rapidly.
Yes
POWER, LOGIN and TX lamps flash in
that order. ERROR lamp also flashes.
Turn off button of No. 1 SSAS.
The POWER, LOGIN and TX lamps flash
in that order.
Turn on button of No.2 SSAS.
Test TX
Turn off button of No.2 SSAS.
Turn communication unit off and
on again.
Note: If a 3rd SSAS unit is installed
test it by procedure used to test
No.2 unit.
19
FELCOM 16/19 (by PC)
1. Press the [F7] key to display the Options menu.
2. Press the [7] key ([6] key when the FELCOM functions as an EGC receiver) to display
the Test menu. For FELCOM 19, press the [8] key.
Test
1. PV Test
2. PV Test Result
3. Diagnostic Test
4. SSAS Button Test
3. Press the [4] key.
Options
Test
1. Login
SSAS Button Test
2.1.Logout
PV Test
3.2.Abort
PV Test Result
Start
4.3.Select
NCS
Self Test
5.4.Ocean
Region
Distress
Alarm Button Test
No
Yes
6. Test
4. Press the [Enter] key to start the test.
Options
Test
1. Login
2.1.Logout
PV Test Distress/SSAS Button Test
3.2.Abort
PV Test Result
4.3.Select
NCS
Distress/SSAS
buttons are under test mode.
Self
Test
CAUTION
5.4.Ocean
Region
Press
any key
to escape.
Distress
Alarm
Button
Test
INF: SSAS6.Buttons
Test entered into TEST MODE.
<Press ESC key to continue>
Test mode
The display shows the message (in red) “SSAS buttons are under test. Cancel the test
mode if a real SSAS alert needs to sent.” appears.
5. Open the button cover on the No. 1 SSAS.
6. Push the button in (ON). The CAUTION window displays the message “SSAS UNIT
works correctly.” appears if the unit is functioning properly.
7. 30 seconds after the button is pushed in the SSAS test report is automatically sent to the
station(s) whose Mode set on the SSAS Report window is “Real+Test” or Test Only”.
8. Turn the button of the No. 1 SSAS off ( ).
Note: To test the No. 2 and No. 3 SSAS repeat steps 6-8.
20
9. To escape from the test, press the [Esc] key twice on the terminal unit. The test mode is
stopped and the message shown below appears to notify you that normal operation has
been restored.
CAUTION
INF: SSAS Buttons returned to NORMAL OPERATION.
<Press ESC key to continue>
Further, because the button remains pushed in (
SSAS button into OFF-STATE.” appears.
), the message “Please return the
10. Push the button again to pop it out ( ).
11. Close the button cover.
12. Press the [Esc] key three times to return to the standby display.
Note: If the button is left pushed in ( ) when the communication unit is turned on, the
equipment will go into the test mode if the SSAS is not transmitting repeatedly. To
return to the standby display, push the button again to pop it out ( ) and then turn
the communication unit off and on again.
3.5 SSAS Report Test
You can test for successful transmission of the SSAS report to the address you specify,
without using the button. The test report message states “!!! Test Call !!!” to alert the
receiver of the message that it is a test call.
Note: This function is only available in the SSAS manager mode. Switch to this mode (see
paragraph 3.1.2) and then follow this procedure.
1.
2.
3.
4.
5.
6.
Access the Report Destination Menu, referring to section 3.2.
Set destination where to transmit the test.
Press the [↑] key to choose Status and then press the [Enter] key.
Press the [↓] key to choose TEST and then press the [Enter] key.
Press the [Esc] key to open the Update window.
Yes is selected; press the [Enter] key. The test report is transmitted. After it is
transmitted, “Status” is automatically set to ON.
7. Press the [Esc] key twice to return to the standby display.
21
4. WATERPROOFING KIT (OPTION)
To mount the IC-305 and IC-307 on a bulkhead, use the optional waterproofing kit to keep
water splash out of the units.
Note: This kit cannot be used if the IC-305 or IC-307 is mounted face upward.
OP-xx (For IC-305)
Name
Type
Code No.
Qty
Fixing Tape
24-009-1225
100-366-200-10
2
OP-xx (For IC-307)
Name
Waterproofing Cover
Fixing Tape
Type
16-023-5501
24-009-1225
Code No.
100-374-950-10
100-366-200-10
Qty
1
2
1. Unfasten four screws to remove cover of IC-305/IC-307.
2. Attach supplied fixing to the underside of the cover as shown in the illustration below.
Fixing tape
3. Attach the cover.
4. For IC-307, remove the seal from the waterproofing cover and attach the cover as
shown in the illustration below.
22
D-1
Mar.03'05
D-2
17/May/2012
Y.NISHIYAMA
D-3
6/Oct/2010
Y. NISHIYAMA
16/Jun/2014 H.MAKI
D-4
1
2
3
4
5
6
S-1
アンテナユニット
ANTENNA UNIT
IC-115
TPA5FB0.4NJ5
FBA-5DFB,0.4m
A
ケーブル/コネクタは選択
SELECT CABLE & CONNECTOR
12D-SFA-CV,100m,φ20: N-P-12DSFA
8D-FB-CV,50m,φ14.3: N-P-8DFB
5D-FB-CV,30m,φ10.7: N-P-5DFB
TNCP-NJ
RW-4747
0.3m
ターミナルユニット
TERMINAL UNIT
IC-215
*7
ANT
TP5FBAW-5DFBB,30m,φ7.7
P
P
DGPS
BNC PLUG
*1
COAX. CABLE(50Ω)
DGPSデコーダー
DGPS DECODER
2B02 16P0208A
キーボード
KEYBOARD
船内LAN (HUB)
パソコンなど
LAN(HUB) OR PC, ETC.
1.6m
P
B
P
24VDC
RH12BPG-3S
VCTF-0.75x3C,5m,φ7 アカ RED
1 +24V
(16S0084)
2 0V
クロ BLK
3 GND
シロ WHT
プリンタ
PRINTER
PP-510
1
*2
36
*4
C
MJ-A3SPF0018-050ZC,5m,φ11
12-24 VDC
100-115/
*1
200-230 VAC DPYC-2.5
1φ,50/60Hz
*1
24 VDC DPYC-4
PE
*1
IV-2sq.
保護アース
1
2
3
4
5
6
7
8
LAN
E_TD_P
E_TD-N
E_RD_P
NC
NC
E_RD_N
NC
NC
*3
17JE-23250
-02(D8C)
16S0184,3m,φ8
24 VDC
KEYBOARD
KDAT
NC
GND
+5V
KCLK
NC
RJ-45
STP CABLE(CAT5) *1
PC: CROSS CABLE
HUB: STRAIGHT CABLE
*3
57-3036
1
2
3
4
5
6
DTE
PRINTER
1
RXD
TXD
25
GND
*4
2B03 16P0209
FUSE
*3
15A(12V)
12-24VDC
MJ-A3SPF
7A(24V)
1 DC(+)
シロ WHT
2 DC(-)
クロ BLK
3 GND
2B10
AC
IN
+ DC
- IN
E
AC/DC
24VDC +
電源ユニット OUT AC/DC POWER
SUPPLY UNIT
PR-240
*2
JUNCTION
Vcc(ALM)
GND
TD/RD-A
TD/RD-B
NC
TD-A
TD-B
RD-A
RD-B
GND
DMC_OUT-H
DMC_OUT-C
DMC_CHECK
DMC_IN-C
DMC_CTRL
16P0214
銅板
COPPER STRAP
W=30,1.2m
接続箱
JUNCTION BOX
IC-315
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
*3
Dsub15P
2m
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
*1
TTYCS-4
P
P
TTYCS-1(*1) OR
CO-0.2x2P(*2)
GND
P
NOTE
*1. SHIPYARD SUPPLY.
*2. OPTION.
*3. FITTED AT FACTORY.
*4. GROUND THRU CONNECTOR CLAMP.
*5. TB BOARD (16P0116) REQUIRED.
*6. CHANGE SETTING OF JUMPER IN IC-307 TO TERMINATE.
*7. DO NOT SHORTEN ANTENNA CABLE.
TTYCS-4(*1) OR
CO-0.2x5P(*2)
RXD
TXD
DTR
GND
DSR
RTS
CTS
NC
RXD
TXD
0V
EGCプリンタ
EGC PRINTER
PP-505 (+) 1
*2
7
NC
1
2
3
4
5
RXD
TXD
NC
NC
0V *2
(-)
P
P
*1
TTYCS-1
3
4
P
保安警報発呼器
SSAS ALERT UNIT
IC-307 (No.2)
*2 *6
1
2
3
4
5
6
P
P
INMARSAT No.1/2
1 TR-A
2 TR-B アラームユニット
ALARM UNIT
3 FG
IC-350 *2
保安警報発呼器
SSAS ALERT UNIT
IC-307 (No.3)
*2 *6
1
2
3
4
5
6
合計 :最大200m
TOTAL: UP TO 200m
1
2
3
4
5
6
7
*2
FM14-7P
FM14-7P
CO-0.2x5P,MAX.100m
1
2
P
3
P
4
5
6
7
*4
*4
20/Nov/2012
CHECKED
20/Nov/2012
APPROVED
20/Nov/2012
SCALE
T.YAMASAKI
T.TAKAHASHI
RXD-H
TXD-H
FG
TXD-C
RXD-C
+9V
NC
EGCプリンタ
EGC PRINTER
PP-505 *2 *5
(+)
(-)
1
2
08S0157,3m
MASS
C5635-C01- T
24VDC
GND
08S0087
TITLE
名称
FELCOM 15
インマルサットC船舶地球局
相互結線図
Y.NISHIYAMA
kg
DWG No.
24VDC
GND
08S0087
FM14-5P
I/F BOX
OP16-14
08S0157,3m
2
*4
DRAWN
CO-0.2x2P: CO-SPEVV-SB-C 0.2x2P,φ10.5
CO-0.2x5P: CO-SPEVV-SB-C 0.2x5P,φ13.5
SSAS_OUT-H
NC
SSAS_CHECK
SSAS_IN-C
SSAS_CTRL
GND
IC-315
最大3台まで接続可能。
MAX.3 SETS AVAILABLE.
パソコン
PC
NC
*2
FM14-7P
CO-0.2x2P,MAX.15m
1
2
3
*4
D
選択
SELECT
17JE-23090
-02(D8C)
1
2
3
4
5
6
7
8
9
*4
注記
*1)造船所手配。
*2)オプション。
*3)工場にて取付済み。
*4)コネクタクランプでアースに落とす。
*5)TB基板(16P0116)が必要。
*6)終端のIC-307はジャンパー設定を変更する。
*7)アンテナケーブルは切断して使用しないこと。
IC-350を接続するとき(IC-305との共用不可)
CONNECTION FOR IC-350 (DO NOT USE W/ IC-305)
*4
DTE
RXD
TXD
1
2
3
4
5
6
P
2
3
4
5
6
7
8
9
*4
遭難警報器 IC-305
DISTRESS ALERT/
RECEIVED CALL UNIT
16P0213C
1 VCC
2 GND
3 TD/RD-A
4 TD/RD-B
5 FG
保安警報発呼器
SSAS ALERT UNIT
IC-307 (No.1) *2 *6
TTYCS-4(*1) OR
CO-0.2x5P(*2)
17JE-23090
17JE-13090
*2
-02(D8C) 17JE-573-10,5m,φ8 -02(D8C)
CO-0.2x5P,MAX.15m
1
1
2
3
4
5
6
7
8
9
航法装置
NAV EQUIPMENT
アラームユニットIC-306
ALARM UNIT
16P0213D
1 VCC
2 GND
3 TD/RD-A
4 TD/RD-B
5 FG
NAME
INMARSAT-C MES
INTERCONNECTION DIAGRAM
FURUNO ELECTRIC CO., LTD.
C
B
A
*6
TPA5FB0.4NJ5
FBA-5DFB,0.4m
*1
DPYC-4
PE
*1
IV-2sq.
保護アース
AC/DC 24VDC +
電源ユニット OUT AC/DC POWER
+ DC SUPPLY UNIT
- IN PR-240
*2
AC
IN
NOTE
*1. SHIPYARD SUPPLY.
*2. OPTION.
*3. FITTED AT FACTORY.
*4. STANDARD SUPPLY FOR SSAS SPEC.
*5. CHANGE SETTING OF JUMPER IN IC-307 TO TERMINATE.
*6. DO NOT SHORTEN ANTENNA CABLE.
注記
*1)造船所手配。
*2)オプション。
*3)工場にて取付済み。
*4)SSAS仕様時標準支給。
*5)終端のIC-307はジャンパー設定を変更する。
*6)アンテナケーブルは切断して使用しないこと。
24 VDC
100-115/
*1
200-230 VAC DPYC-2.5
1φ,50/60Hz
TNCP-NJ
2B02 16P0208B
ANT
3
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
*3
D-sub15P
DWG No.
SCALE
1/Apr/2010
MASS
kg
Y.NISHIYAMA
T.TAKAHASHI
T.YAMASAKI
C5638-C01- L
30/Mar/2010
CHECKED
30/Mar/2010
APPROVED
DRAWN
CO-0.2x5P: CO-SPEVV-SB-C 0.2x5P,φ13.5
2m
接続箱 IC-315
JUNCTION BOX
*4
1 Vcc
2 GND
3 TD/RD-A
4 TD/RD-B
5 NC
6 TD-A
7 TD-B
8 RD-A
9 RD-B
10 GND
11 DMC_OUT-H
12 DMC_OUT-C
13 DMC_IN-H
14 DMC_IN-C
15 DMC_CTR
*3
*3
17JE-13090
17JE-23090
-02(D8C)
-02(D8C)
*2
17JE-573-10,5m,φ8
1
1
2
2
3
3
4
4
5
5
6
6
7
7
8
8
9
9
銅板 COPPER STRAP
W=30,1.2m
Vcc(6.5V)
GND
TX/RX-A
TX/RX-B
NC
2B10 16P0227
NC
NC
NC
NC
NC
SSAS_OUT-H
NC
SSAS_CHECK
SSAS_IN-C
SSAS_CTRL
SSAS
GND
RXD
TXD
通信制御ユニット
COMMUNICATION UNIT
IC-216
DTE
2
FUSE
10A:12VDC
*3
12-24VDC
FM-C3FP
5A:24VDC
1 DC(+)
アカ RED
2 DC(-)
クロ BLK
3 GND
TP5FBAW-5DFBB,30m,φ7.7
TP58A15W-RG58,15m,φ5
ケーブル/コネクタは選択
SELECT CABLE & CONNECTOR
12D-SFA-CV,100m,φ20: N-P-12DSFA
8D-FB-CV,50m,φ14.3: N-P-8DFB
5D-FB-CV,30m,φ10.7: N-P-5DFB
12-24 VDC FM-C3FPS-002,3.5m,φ7.5
RW-4747
0.3m
アンテナユニット
ANTENNA UNIT
IC-116
1
NC
RXD
TXD
DTR
GND
DSR
RTS
CTS
NC
P
P
パソコン
PC
P
P
保安警報発呼器
SSAS ALERT UNIT
IC-307 (No.2)
*4 *5
1
2
3
4
5
6
NAME
名称
TITLE
P
2
3
4
5
6
最大3台まで接続可能
MAX. 3 UNITS AVAILABLE
P
保安警報発呼器
SSAS ALERT UNIT
IC-307 (No.3)
*2 *5
1
INTERCONNECTION DIAGRAM
INMARSAT MINI-C MES
相互結線図
FELCOM 16
インマルサットMINI-C携帯移動地球局
TTYCS-4(*1) OR CO-0.2x5P(*2)
合計:最大200m
TOTAL: UP TO 200m
保安警報発呼器
SSAS ALERT UNIT
IC-307 (No.1)
*4
1 SSAS_OUT-H
2 NC
3 SSAS_CHECK
4 SSAS_IN-C
5 SSAS_CTRL
6 GND
4
S-2
1
2
4
3
5
S-3
6
アラームユニット
1
2
3
4
5
P
P
アンテナユニット
ANTENNA UNIT
IC-118
TPA5FB0.4NJ5 12D-SFA-CV,100m,φ20: N-P-12DSFA
FBA-5DFB,0.4m 8D-FB-CV,40/50m,φ14.3: N-P-8DFB
5D-FB-CV,30m,φ10.7: N-P-5DFB
ターミナルユニット
TERMINAL UNIT
IC-218
JUNCTION
TNCP-NJ
A
ANT
TP5FBAW-5DFBB,30m,φ7.7
DGPS
DGPSデコーダー
DGPS DECODER
COAX. CABLE(50Ω)
BNC
USB
A TYPE
キーボード
KEYBOARD
RH12BPG-3S
VCTF-0.75x3C,5m,φ7
(16S0084)
24 VDC (+) アカ RED
(-) クロ BLK
GND シロ WHT
B
3
*1
12 VDC
DC/DCコンバータ
DC/DC CONVERTER
100-115/
*1
200-230 VAC DPYC-2.5
1φ,50/60Hz
*1
24 VDC
DPYC-4
PE
*1
IV-2sq.
保護アース
AC
IN
+ DC
- IN
E
4
17JE-23250
57-3036 -02(D8C)
プリンタ 36
25
16S0184
PRINTER
3m,φ8
PP-510 *2
または
OR
H230817-1(*2)
防水仕様ケーブル
WATERPROOF CABLE
MJ-A3SPF0018-050Z
5m,φ11
12-24VDC
1.5m
AC/DC
24VDC +
電源ユニット OUT AC/DC POWER
SUPPLY UNIT
PR-240
*2
15A(12V)
MJ-A3SPF
7A(24V)
シロ WHT
1
クロ BLK
2
3
PRINTER
Vcc(ALM)
GND
TD/RD-A
TD/RD-B
NC
ALM-H
ALM-C
RD-A
RD-B
GND
SSAS_OUT-H
SSAS_OUT-C
SSAS_CHECK
SSAS_IN-C
SSAS_CTRL
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
17JE-23150
-02(D8C) 2m
接続箱
JUNCTION BOX
IC-318
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
VCC ALARM UNIT
GND IC-306
TD/RD-A *2
TD/RD-B
GND
IC-350を接続するとき(IC-305との共用不可)
CONNECTION FOR IC-350 (DO NOT USE W/ IC-305)
遭難警報器
DISTRESS ALERT/
*2
RECEIVED CALL UNIT
TTYCSLA-4(*1) OR CO-0.2x5P(*2)
P
P
TTYCSLA-1(*1) OR
CO-0.2x2P(*2)
TTYCSLA-1(*1) OR
CO-0.2x2P(*2)
1
2
3
4
5
IC-305
VCC
GND
TD/RD-A
TD/RD-B
GND
選択
SELECT
P
P
1
2
3
4
5
6
3
4
TTYCSLA-1(*1) OR
CO-0.2x2P(*2)
IC-307(No.2)
SSAS_OUT-H
NC
SSAS_CHECK
SSAS_IN-C
SSAS_CTRL
GND
P
P
1 *2 *3 *4
2
3
4
5
6
*1
IV-2sq.
LAN
RJ45
8
*1
STP(CAT5)
DC IN
IC-307(No.3)
P
P
1
2
3
4
5
6
*2 *3
最大3台まで接続可能
MAX. 3 UNITS AVAILABLE.
TTYCSLA-4(*1) OR
CO-0.2x5P(*2)
合計 :最大200m
TOTAL: UP TO 200m
パソコン/HUB
PC OR HUB
INMARSAT No.1/2
1 TR-A
2 TR-B アラームユニット
ALARM UNIT
3 FG
IC-350
アラームシステム
ALARM SYSTEM
航法装置
保安警報発呼器
NAV EQUIPMENT SSAS ALERT UNIT
IC-307 *2 *3 *4
TTYCSLA-4(*1) OR CO-0.2x5P(*2)
IC-318
DC+
DCGND
銅板
COPPER STRAP
W=30,1.2m
IC-218
JUNCTION
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
C
防水仕様ケーブル
WATERPROOF CABLE
*2
XM-FD-361,2m
アオ BLU
チャ BRN
ムラサキ PPL
ハイ GRY
ミドリ GRN
YEL
キ
ORG
ダイ
モモ PNK
ウスミドリ L-GRN
シロ/クロ WHT/BLK
シロ/アカ WHT/RED
クロ BLK
アカ RED
ミズ L-BLU
接続箱
JUNCTION BOX
IC-318
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
D
注記
*1)造船所手配。
*2)オプション。
*3)終端のIC-307はジャンパー設定を変更する。
*4)SSAS仕様のとき標準構成。
NOTE
*1: SHIPYARD SUPPLY.
*2: OPTION.
*3: CHANGE SETTING OF JUMPER IN IC-307 TO TERMINATE.
*4: STANDARD CONFIGURATION FOR SSAS.
DRAWN
CO-0.2x2P: CO-SPEVV-SB-C 0.2x2P,φ10.5
CO-0.2x5P: CO-SPEVV-SB-C 0.2x5P,φ13.5
12/Dec/2012 T.YAMASAKI
CHECKED
12/Dec/2012 H.MAKI
APPROVED
18/Dec/2012 Y.NISHIYAMA
SCALE
MASS
kg
DWG No.
C5674-C01- D
REF.No.
16-023-3001-1
TITLE
FELCOM 18
名称
インマルサット-C 船舶地球局
相互結線図
NAME
INMARSAT-C MES
INTERCONNECTION DIAGRAM
C
B
A
PE
*1
IV-2sq.
保護アース
DPYC-4
AC
IN
+ DC
- IN
E
AC/DC
24VDC +
電源ユニット OUT AC/DC POWER
SUPPLY UNIT
PR-240
*2
2
DC+
DCGND
DC IN
ANT
8
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
RJ45
*1
STP(CAT5)
17JE-23150
-02(D8C) 2m
銅板
COPPER STRAP
W=30,1.2m
LAN
Vcc(ALM)
GND
TD/RD-A
TD/RD-B
NC
ALM-H
ALM-C
RD-A
RD-B
GND
SSAS_OUT-H
SSAS_OUT-C
SSAS_CHECK
SSAS_IN-C
SSAS_CTRL
通信制御ユニット
COMMUNICATION UNIT
IC-219
JUNCTION
NOTE
*1: SHIPYARD SUPPLY.
*2: OPTION.
*3: CHANGE SETTING OF JUMPER IN IC-307 TO TERMINATE.
*4: STANDARD CONFIGURATION FOR SSAS.
注記
*1)造船所手配。
*2)オプション。
*3)終端のIC-307はジャンパー設定を変更する。
*4)SSAS仕様のとき標準構成。
24 VDC
100-115/
*1
200-230 VAC DPYC-2.5
1φ,50/60Hz
*1
12-24VDC
TNCP-NJ
10A(12V)
MJ-A3SPF
5A(24V)
シロ WHT
1
クロ BLK
2
3
TP5FBAW-5DFBB,30m,φ7.7
12D-SFA-CV,100m,φ20: N-P-12DSFA
8D-FB-CV,50m,φ14.3: N-P-8DFB
5D-FB-CV,30m,φ10.7: N-P-5DFB
TPA5FB0.4NJ5
FBA-5DFB,0.4m
MJ-A3SPF0016-035
3.5m
アンテナユニット
ANTENNA UNIT
IC-119
1
*1
IV-2sq.
P
TTYCSLA-4(*1) OR
CO-0.2x5P(*2)
合計 :最大200m
TOTAL: UP TO 200m
SSAS ALERT UNIT
IC-307 *2 *3 *4
1 SSAS_OUT-H
2 NC
3 SSAS_CHECK
4 SSAS_IN-C
5 SSAS_CTRL
6 GND
保安警報発呼器
アラームシステム
ALARM SYSTEM
航法装置
NAV EQUIPMENT
31/May/2012
DWG.No.
SCALE
C5675-C01- D
kg
Y.NISHIYAMA
H.MAKI
T.YAMASAKI
MASS
31/May/2012
CHECKED
31/May/2012
APPROVED
DRAWN
REF.No.
16-023-4001-1
CO-0.2x2P: CO-SPEVV-SB-C 0.2x2P,φ10.5
CO-0.2x5P: CO-SPEVV-SB-C 0.2x5P,φ13.5
P
TTYCSLA-4(*1) OR
CO-0.2x5P(*2)
TTYCSLA-1(*1) OR
CO-0.2x2P(*2)
TTYCSLA-1(*1) OR
CO-0.2x2P(*2)
パソコン/HUB
PC OR HUB
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
接続箱
JUNCTION BOX
IC-318 *2 *4
3
NAME
名 称
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
1
2
3
4
5
6
*2 *3
ミドリ GRN
YEL
キ
ORG
ダイ
モモ PNK
ウスミドリ L-GRN
シロ/クロ WHT/BLK
シロ/アカ WHT/RED
クロ BLK
アカ RED
ミズ L-BLU
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
接続箱
JUNCTION BOX
IC-318
最大3台まで接続可能
MAX. 3 UNITS AVAILABLE.
P
防水仕様ケーブル
WATERPROOF CABLE
*2
XM-FD-361,2m
アオ BLU
チャ BRN
ムラサキ PPL
ハイ GRY
P
IC-307(No.3)
INTERCONNECTION DIAGRAM
INMARSAT MINI-C MES
相互結線図
FELCOM 19
インマルサットMINI-C携帯移動地球局
JUNCTION
IC-219
P
TITLE
P
1 *2 *3 *4
2
3
4
5
6
IC-307(No.2)
4
S-4
Fly UP