Comments
Description
Transcript
operator`s manual
OPERATOR'S MANUAL SHIP SECURITY ALERT SYSTEM (SSAS) Model IC-307 (For FELCOM 15/16/18/19) www.furuno.com The paper used in this manual is elemental chlorine free. ・FURUNO Authorized Distributor/Dealer 9-52 Ashihara-cho, Nishinomiya, 662-8580, JAPAN All rights reserved. Printed in Japan A : MAY 2004 G : JAN . 23, 2015 Pub. No. OME-56351-G ( GREG ) IC-307(SSAS) 0 0 0 1 5 0 3 5 9 1 6 TABLE OF CONTENTS SYSTEM CONFIGURATION ..................................................................................... ii 1. OVERVIEW OF SSAS .......................................................................................... 1 2. INSTALLATION .................................................................................................... 3 2.1 Mounting ........................................................................................................................... 3 2.1.1 Junction box (for FELCOM 16/FELCOM 19) ........................................................... 3 2.1.2 SSAS alert unit ......................................................................................................... 4 2.2 Wiring................................................................................................................................ 6 2.2.1 Junction box (for FELCOM 16/19) ........................................................................... 6 2.2.2 SSAS alert unit ......................................................................................................... 7 2.3 Initial Settings ................................................................................................................... 8 3. OPERATION ......................................................................................................... 9 3.1 Operation Mode ................................................................................................................ 9 3.1.1 Changing the password............................................................................................ 9 3.1.2 SSAS manager mode ............................................................................................ 10 3.2 Setting SSAS Report Destination and Message Contents .............................................. 11 3.3 Transmitting SSAS Report .............................................................................................. 14 3.4 Testing the Button ........................................................................................................... 16 3.5 SSAS Report Test ........................................................................................................... 21 4. WATERPROOFING KIT (OPTION) .................................................................... 22 OUTLINE DRAWINGS........................................................................................... D-1 INTERCONNECTION DIAGRAMS .........................................................................S-1 i SYSTEM CONFIGURATION Regulations require at least two SSAS alert units. FELCOM 15 ANTENNA UNIT IC-115 DGPS 100-115/200-230 VAC 1, 50/60 Hz AC-DC Power Supply PR-240-CE*1 24 VDC EGC Printer PP-50 TERMINAL UNIT IC-215 Personal Computer (PC/AT compatible) GPS receiver OP16-24 12/24 VDC 24 VDC Printer Shipboard LAN (Ethernet) Printer PP-510 24 VDC Mini Keyboard SSAS Alert Unit IC-307 Distress Alert/ Received Call Unit IC-305 SSAS Alert Unit IC-307 JUNCTION BOX IC-315 (Max. 3 units) SSAS Alert Unit IC-307 Alarm Unit IC-306 Navigator : Standard Supply : Option : Local Supply *1 Any AC-DC power supply fulfilling requirements of IEC 60945 may be used. FELCOM 16 ANTENNA UNIT IC-116 PRINTER O SSAS Alert Unit IC-307 POWER ii R RO IN G I SSAS Alert Unit IC-307 (Max. 3 units) LO 12/24 VDC SSAS Alert Unit IC-307 INMARSAT MINI-C MOBILE EARTH STATION PO W FURUNO ER COMMUNICATION UNIT IC-216 (with internal GPS receiver) ER 24 VDC AC-DC Power Supply PR-240-CE TX 100-115/200-230 VAC 1, 50/60 Hz JUNCTION BOX IC-315 PERSONAL COMPUTER (PC/AT compatible) : Standard : Option : Local Supply FELCOM 18 FELCOM 19 ANTENNA UNIT IC-119 AC-DC Power Supply PR-240 SHIP'S MAINS 12-24 VDC PERSONAL COMPUTER (Windows OS) COMMUNICATION UNIT IC-219 (with internal GPS receiver) JUNCTION BOX IC-318 SSAS ALERT UNIT IC-307* SSAS ALERT UNIT IC-307* iii * At least two SSAS Alert Units are required. NAVIGATOR (GLONASS compliant) 1. OVERVIEW OF SSAS The IC-307 SSAS (Ship Security Alert System) Alert Unit connects to the Inmarsat-C MES FELCOM 15/FELCOM 18 or the Inmarsat Mini-C FELCOM 16/FELCOM 19 for the purpose of alerting specified addresses (for example, your ship’s company) that your ship is under attack by intruders. The SOLAS Resolution XI-2/6 requires vessels of 500 GT or more constructed before 01 July 2004 to install an SSAS. When your ship is under attack an SSAS report, which contains your ship’s name, MMSI No., position, etc. is sent to up to five locations, specified by the ship’s captain or authorized personnel. No audible or visible alarm is generated while the SSAS report is being transmitted, to prevent discovery of the report by the intruders. The SSAS is protected with a password to prevent unauthorized setting or testing of it by other than the ship’s captain or authorized personnel. Inmarsat System Ship Name, MMSI No., Ship Position, etc. Headquarters Ship Ship's Company, Management Company 1 SSAS operation flow 1. Open the cover of the button and then press the button. (This is a latch-type button; hit and release to activate the button.) 2. If addresses have been preset, the SSAS report is sent to one address 30 seconds after the button is activated. (Max. 5 addresses) (You may cancel transmission of the SSAS report by pressing the button again within 30 seconds of the initial press.) 3. An LES sends acknowledgement to your ship. 4. Steps 2-3 and are repeated in case of multiple addressees. 5. Continuous transmission of the SSAS report begins. (The interval at which to transmit the SSAS report to each address can be specified. The SSAS report is continuously transmitted while the button is ON, at the interval selected.) 6. To stop transmission, press the button again to deactivate it. (This is only possible in the SSAS manager mode. See paragraph 3.1.) 2 2. INSTALLATION 2.1 Mounting 2.1.1 Junction box (for FELCOM 16/FELCOM 19) The junction box IC-315 is required when installing the SSAS on the FELCOM 16/FELCOM 19; it is already installed on the FELCOM 15/FELCOM 18. Separate the junction box from a magnetic compass by the distances shown below to prevent deviation to a magnetic compass. IC-315 Standard compass: 1.0 m Steering compass: 0.7 m IC-318 Standard compass: 0.90 m Steering compass: 0.60 m 1. Remove four screws from the unit to separate the cover from the unit. 2. Fix the unit to the mounting location with four self-tapping screws (4x16, supplied). 3. Connect the cables appropriately referring to paragraph 2.2.1. 120 0.5 70 0.5 Junction box IC-315/318 The junction box is connected to the communication unit with a 2 meter cable, with D-sub connector (at the communication unit). Therefore, locate the junction box within two meters of the communication unit. 3 2.1.2 SSAS alert unit Separate the junction box from the SSAS alert unit by the distances shown below to prevent deviation to a magnetic compass. Standard compass: 0.70 m Steering compass: 0.45 m Locate the SSAS alert unit where it cannot be found by intruders. The location should be known only by ship’s captain and authorized personnel. Bulkhead mounting 1. Remove four screws from the unit to separate the bottom chassis from the top cover. 2. Fix the unit to the mounting location with four self-tapping screws (supplied). 3. The cable can be lead in from the bottom or the rear panel. For rear panel entrance, change the clamp orientation as follows: a) Unfasten three screws to remove the cable clamp. b) Turn the clamp 90 degrees. c) Refasten the clamp with three screws unfastened at step a) to fix the clamp. Unfasten three screws. Clamp Turn Fasten three screws. 4. Run the cable thru one of the cable entrances and connect it to terminal board. 4 5. Attach the switch cover as shown below. Note that the cover may also be rotated 180 degrees. Press here and hold down for five seconds. Switch cover Flush mounting The optional flush mount kit OP16-28 (Code No. 004-448-010) is required. Name Fixture Pan head screw Self-tapping screw Type Code No. 16-018-7201-1 100-317-931 M3x6 000-800-362 4x16 000-802-080 Qty 1 4 4 Remarks 1. Cut out the mounting position referring to the outline drawings at the back of this manual. 2. Fix the unit to the fixture with four pan head screws (supplied). 3. Fasten the fixture with the unit to the mounting location with four self-tapping screws (supplied). 4. Attach switch cover as shown above. 5 2.2 Wiring 2.2.1 Junction box (for FELCOM 16/19) Use the junction box IC-315 to connect the SSAS alert unit to the FELCOM 16, or the junction box IC-318 to connect the SSAS alert unit to the FELCOM 19. Unfasten four screws to remove the cover to connect cables to terminal board. For detailed wiring information see the interconnection diagram. For connecting the SSAS alert unit IC-307, use the JIS cable TTYCS-4 (or equivalent, see next page for sectional view of this cable) or the CO-SPEVV-SB-C 0.2x5P. When using the CO-SPEVV-SB-C 0.2x5P cable, replace the cable clamp with the cable clamp 16-018-6008-1, supplied with the junction box. For connecting the communication unit IC-216, use cable 16S0344. 1 Vcc 2 GND 3 TD/RD-A 4 TD/RD-B 5 NC 6 TD-A(NAV) 7 TD-B(NAV) 8 RD-A(NAV) 9 RD-B(NAV) 10 GND 11 DMC OUT-H 12 DMC OUT-C 13 DMC IN-H 14 DMC IN-C 15 DMC CTR Cover Cable clamp (top) Terminal board 1 Vcc 2 GND 3 TD/RD-A 4 TD/RD-B 5 NC 6 ALM-H 7 ALM-C 8 RD-A(NAV) 9 RD-B(NAV) 10 GND 11 SSAS OUT-H 12 SSAS OUT-C 13 SSAS IN-H 14 SSAS IN-C 15 SSAS CTR Communication Unit IC-305/306 IC-318 IC-305/306 IC-315 1 2 Cable clamp (bottom) Cable clamp 3 Fold back braided shield onto sheath and fix by cable clamp. 16S0344 Core 7 mm Procedure 1. Insert driver from direction 1 . 15mm 90mm 7mm 2. Tilt slightly toward 2 . 3. Insert cable core to 3 . Connect the drain wire of the TTYCSLA cables with the screw and crimp-on lugs provided. Note 1: Do not insert the cable too deeply, to prevent pinching the sheath. Screw, crimp-on lug (pre-fitted at factory) Note 2: Pull each cable slightly to confirm that they are in their holes securely. IC-318 (inside) 6 2.2.2 SSAS alert unit Three SSAS alert units can be connected. For wiring, see the illustrations below and the interconnection diagram at the back of this manual. For the terminal unit (FELCOM 15/18) and the communication unit (FELCOM 16/19), the wiring of the SSAS is monitored and if in error “TROUBLE: SSAS UNIT connection abnormality.” is displayed. Further the ERROR lamp (FELCOM 16/19) flashes. Junction Box IC-307 (No.1) IC-307 (No. 3) IC-307 (No. 2) Connect wiring to the terminal board 16P0229 inside the SSAS unit. To differentiate between units in case of multiple unit installation, change jumper block settings as shown below, in accordance with how many units are installed. Jumper settings for two IC-307 Unit No.1 unit* No. 2 unit Jumper JP1 No Yes JP2 Yes No No. 1 unit: Unit with two cables connnected to it. No. 2 unit: Unit with one cable connnected to it. Two IC-307: No. 2 Three IC-307: No. 3 16P0229 JP1 Two IC-307: No. 1 Three IC-307: No. 1 and No. 2 16P0229 JP2 1 2 Jumper settings for three IC-307 No. 2 unit* No. 3 unit *: Default Jumper Unit No.1 unit* setting JP1 No No Yes JP2 Yes Yes No No. 1 and No. 2 units: Units with two cables connnected to them. No. 3 unit: Unit with one cable connnected to it. JP1 3 4 5 IC-307 6 JP2 1 2 3 4 5 6 IC-307 Cable Fabrication Twist shield. Clamp for cable CO-SPEVV-SB-C 0.2x5P CO-SPEVV-SB-C 0.2X5P or TTYCS-4 Cut and tape unused wires to prevent short. 15 mm 40 mm 10 mm = 16.3 mm Clamp for cable TTYCS-4 or equivalent Armor Sheath Shield Conductor S = 0.75 mm2 = 1.11 mm Sectional view of cable TTYCS-4 7Wiring inside the SSAS alert unit 7 2.3 Initial Settings Set up the SSAS as follows: 1. FELCOM 15: Press [F8], [2] to show the System Setup menu. FELCOM 16/18/19: Press [F8], [1] to show the System Setup menu. 2. Press [↓] to choose Command Window and then press the [Enter] key. Command Window Command Window [Main menu] 1. Remote Box Setup 2. External Alarm Setup 3. AMS Setup 4. Management Profile Setup Enter JOB No.: RFCONCPU *** [ Main Menu ] 1. Remote Box Setup 2. Internal GPS Setup Enter JOB No. : FELCOM 15/16 FELCOM 18/19 3. Type “furunoservice” (without quotation marks) in the Enter JOB No. field and then press the [Enter] key. The prompt PASSWORD appears. 4. Enter password (see FURUNO Information for SSAS) then press the [Enter] key. Then, the item Main Menu is displayed in reverse video. 5. Press [1], [Enter], [1], [Enter]. One of the following windows appears. 6. Press [1], [Enter]. This enables the SSAS functions. 7. Press the [Esc] key several times to close the menu. Note: Test the SSAS button and SSAS report for proper operation, referring to paragraphs 3.4 and 3.5, respectively. 8 3. OPERATION 3.1 Operation Mode There are two menu operating modes: Normal mode: Menus other than SSAS-related menus are displayed. SSAS manager mode: The mode is activated by the password entered by the ship’s captain or authorized personnel. The indication “SSAS Manager Mode” is shown at the top of the screen when this mode is activated. All SSAS-related menus are available. Transmission of the SSAS report may be cancelled in this mode. The equipment starts up in the normal mode, regardless of the mode in use when the power is turned off. 3.1.1 Changing the password The default password is “ship security alert”. Ship’s captain or authorized personnel may change the password as follows: 1. FELCOM 15: Press [F8], [2] to show the System Setup menu. FELCOM 16/18/19: Press [F8], [1] to show the System Setup menu. 2. Press [↓] to choose Command Window and then press the [Enter] key. Command Window Command Window [Main menu] 1. Remote Box Setup 2. External Alarm Setup 3. AMS Setup 4. Management Profile Setup Enter JOB No.: RFCONCPU *** [ Main Menu ] 1. Remote Box Setup 2. Internal GPS Setup Enter JOB No. : FELCOM 15/16 FELCOM 18/19 3. On the Enter JOB No. field, type “ssas password” (without quotation marks) and then press the [Enter] key. The prompt OLD PASSWORD appears. 4. Type your current password and then press the [Enter] key. The prompt NEW PASSWORD appears. 5. Enter new password, using at least six characters, and then press the [Enter] key. The prompt RETYPE NEW PASSWORD appears. Note: If less than six characters are entered for the password, the message “Please use a longer password.” appears. Enter a longer password. 6. Enter new password again and then press the [Enter] key. The message “Password changed” appears. 7. Press the [Esc] key several times to close the menu. Note: The SSAS manager mode cannot be unlocked without the proper password. 9 3.1.2 SSAS manager mode All SSAS-related settings are set in the SSAS manager mode. Do the following to access this mode. 1. FELCOM 15: Press [F8], [2] to show the System Setup menu. FELCOM 16/18/19: Press [F8], [1] to show the System Setup menu. 2. Press [↓] to choose Command Window and then press the [Enter] key. Command Window Command Window [Main menu] 1. Remote Box Setup 2. External Alarm Setup 3. AMS Setup 4. Management Profile Setup Enter JOB No.: RFCONCPU *** [ Main Menu ] 1. Remote Box Setup 2. Internal GPS Setup Enter JOB No. : FELCOM 15/16 FELCOM 18/19 3. On the Enter JOB No. field, type “ssas manager” (without the quotation marks) and then press the [Enter] key. Note: If there is no SSAS equipment connected, the message "Command Ignored: No SSAS button is installed." appears. 4. Type password and then press the [Enter] key to go into the “SSAS Manager Mode”. The indication “SSAS Manager Mode” is shown at the top of the screen when this mode is activated, and it is flashing. CAUTION 04-04-20 05:37 (UTC) SSAS Manager Mode enabled. <Press ESC key to continue> 5. Press the [Esc] key several times to close the menu. This enables the SSAS manager mode, which allows you to execute the procedure in paragraph 3.2. Note: Turn the power off and on again whenever changing SSAS-related settings. 10 3.2 Setting SSAS Report Destination and Message Contents When the SSAS is activated, the SSAS report is sent according to the addresses (max. 10) and message content set with SSAS Report 1 – SSAS Report 10 on the SSAS Report menu. Note 1: The destination and message content of an SSAS report varies according to Administration. Therefore, set them as requested by ship’s authorities. For information other than ship’s name, MMSI no. and IMN no., set it manually with “Other Inf.” Note 2: The equipment must be in the SSAS manager mode to execute this procedure. See paragraph 3.1.2. 1. Press the [F5] to open the Reports menu. Reports Reports 1. Data Report 2. Message Report 3. Data Network ID 4. SSAS Report 1. Data Report 2. Message Report 3. Enhanced Pre-Assigned Data Report (EPADR) 4. Data Network ID 5. SSAS Report FELCOM 15/16 FELCOM 18/19 2. For FELCOM15/19, press the [4] key to show the SSAS Report menu. For FELCOM 18/19, press the [5] key. SSAS Report 1. SSAS Report 1 2. SSAS Report 2 SSAS Report 1. SSAS Report Destination 2. Message Contents 3. SSAS Report 3 4. SSAS Report 4 5. SSAS Report 5 FELCOM 18/19 6. Message Contents FELCOM 15/16 3. For FELCOM 15/16, press the appropriate report number ([1] through [5]) to show the SSAS Report Destination menu. For FELCOM 18/19, press the [1] key. SSAS Report Desitnation Enter: Report Entry ESC: Quit No 01 02 03 04 05 06 07 Mode Destination Interval Test Only test@test 00:10 Real+Test 123456789 02:00 Interval is displayed in the hh:mm format. Setting range: 00:10 to 99:59 Destination ID or mail address 08 09 10 Selected mode (Real+Test, Real Only, Test Only) is displayed here The SSAS Report Destination menu displays any current reports. 11 4. Press the [↑] or [↓] key to choose the report number desired and then press the [Enter] key to display the selected SSAS report’s details. Status Mode Station Name Destination Type Prefix Code Country/Ocean Code Station ID Modem Type Address Subject LES ID Report Interval SSAS Report ON Real+Test Status Mode Station Name Destination Type Prefix Code Country/Ocean Code Destination Modem Type Address Subject LES ID Report Interval TELEX 02:00 (hh: mm) FELCOM 15/16 SSAS Report ON Real+Test TELEX/MES 02:00 FELCOM 18/19 5. Press the [↓] key to choose Mode and then press the [Enter] key. Real+Test Real Only Test Only 6. Press the [↑] or [↓] key to choose mode desired and then press the [Enter] key. “Mode” defines what SSAS report(s) a station is to receive: Real+Test: Actual SSAS report and test SSAS report. Real Only: Actual SSAS report only. Test Only: Test SSAS report only. 7. Press the [↓] key to choose Station Name and then press the [Enter] key. 8. Press the [↑] or [↓] key to choose appropriate station and then press the [Enter] key. You may sort the list by group name, station name or communication type as follows: Group name: Each press of [Ctrl] + [G] sorts the list by group name, ascending or descending order. Station name: Each press of [Ctrl] + [N] sorts the list by station name, in ascending or descending order. Comm. type: Each press of [Ctrl] + [T] sorts the list by communication type, in ascending or descending order. 9. Press the [↓] key to choose LES ID and then press the [Enter] key. 10. Press the [↑] or [↓] key to choose LES and then press the [Enter] key. Note: Change the LES whenever sea area has changed. However, the equipment automatically searches for an LES with which you can communicate and the SSAS report is transmitted to that LES. 11. Press the [↓] key to choose Report Interval and then press the [Enter] key. 12. Enter time interval (00:10-99:59) to transmit the SSAS report and then press the [Enter] key. 13. Press the [Esc] key to show the Update window. Update Yes No 14. Yes is selected; press the [Enter] key to close the SSAS report window. 12 15. Press the [2] key to display the SSAS Message Contents menu. Vessel Name : MMSI : IMN : Other Inf. : LAT: LON: Time: COURSE: SPEED: Time: SSAS Message Contents ______________________________ _________ _________ _______________________________________________________ _______________________________________________________ _______________________________________________________ 34: 44. 46N 135: 21. 26E 02/04/2012 04:31:48 (UTC) 071 deg 00 kt 02/04/2012 04:31:48 (UTC) FELCOM 15/16 SSAS Message Contents _ _ _ _ _ _ _ _ _ _____________________ Vessel Name : Call Sign : _________ MMSI : _________ IMN : _________ IMO : _________ Other Inf. : ___________________________________________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ ___________________________________________________ LAT: 34: 44. 46N LON: 135: 21. 26E Time: 02/04/2012 04:31:48 (UTC) COURSE: 071 deg SPEED: 00 kt Time: 02/04/2012 04:31:48 (UTC) FELCOM 18/19 16. Press the [Enter] key to open the Vessel Name window. 17. Enter vessel’s name and then press the [Enter] key. 18. Press the [↓] key to choose MMSI and then press the [Enter] key. 19. Enter MMSI number and then press the [Enter] key. 20. Press the [↓] key to choose IMN and then press the [Enter] key. 21. Enter IMN and then press the [Enter] key. 22. Press the [↓] key to choose Other Inf. and then press the [Enter] key 23. Enter appropriate message (for FELCOM15/16: three lines, for FELCOM18/19: six lines) and then press the [Enter] key. Note: To shift between lines, use the [↑] or [↓] key. 24. Press the [Esc] key to show the Update window. 25. Yes is selected; press the [Enter] key to close the SSAS Message Contents menu. 26. Press the [Esc] key twice to return to the standby display. Note 1: To delete entered subscriber’s data, choose “Remove” from “Status.” Note 2: SSAS report settings may be saved to a floppy disk for backup. FELCOM 15: [F8], [9], [6] to show the Save/Load window. FELCOM 16: [F8], [8], [6] to show the Save/Load window. FELCOM 18/19: [F8], [8], [6] to show the Export/Import window. 13 Save to FD 1. ALL 2. Station List 3. LES List 4. E-Mail Service List 5. SSAS Report* 6. Other Load from FD 1. ALL 2. Station List 3. LES List 4. E-Mail Service List 5. SSAS Report* 6. Other *: Availlable only in SSAS manager mode ("5.SSAS Report" is added in the SSAS manager mode and item numbers are shifted.) FELCOM15/16 Export 1. Sent Message 2. Received Message 3. EGC Message 4. Station List 5. LES List 6. E-Mail/SMS Service List 7. Test 8. Maintenance 9. Settings Import 1. Station List 2. LES List 3. E-Mail/SMS Service List 4. Settings FELCOM 18/19 Note 3: To confirm the settings, follow paragraph 3.5. 3.3 Transmitting SSAS Report In the normal mode, the SSAS report is sent 30 seconds after the button on the SSAS is pressed. The SSAS repeatedly transmits the report even if the button is pushed off ( ). Repeated transmission can only be stopped from the SSAS manager mode. 1. Open the cover of the SSAS alert button. 2. Push the button. The button is a latch-type button; hit and release the button to activate ( ) the SSAS unit. 3. The SSAS report is transmitted 30 seconds after the button is pushed in ( ). Below are the contents of the SSAS report. - - - SSAS ALERT MESSAGE - - Vessel Name: Queen Elizabeth 2 MMSI: 111660000 IMN: 443100000 Help me! LAT: 34:44.46N LON: 135:21.26E Time: 02/04/2004 04:31:48 (UTC) COURSE: 071 deg SPEED: 00 kt Time: 02/04/2004 04:31:48 (UTC) Ship's Name MMSI No. IMN No. Desired message Own ship postion in latitude Own ship position in longitude Time of position data Course Speed Time of course and speed data FELCOM 15/16 14 Cover - - - SSAS ALERT MESSAGE - - Vessel Name: Queen Elizabeth 2 MMSI: 111660000 IMN: 443100000 IMO: 123456789 Help me! LAT: 34:44.46N LON: 135:21.26E Time: 02/04/2004 04:31:48 (UTC) COURSE: 071 deg SPEED: 00 kt Time: 02/04/2004 04:31:48 (UTC) Ship's Name MMSI No. IMN No. IMO No. Desired message Own ship postion in latitude Own ship position in longitude Time of position data Course Speed Time of course and speed data FELCOM 18/19 4. 5. 6. 7. An LES sends acknowledgement to your ship. For multiple destinations, steps 3 and 4 are repeated. The SSAS report is transmitted repeatedly while the button remains pushed in ( ). To stop transmission, push the button again to pop it out ( ). (SSAS manager mode only.) Note: If transmission is not canceled with the button and the power is turned off, the equipment resumes repeated transmission when powered again. How to cancel the transmission when the transmission is erroneously made (FELCOM15/16/18/19) Note 1: The SSAS report is sent 30 seconds after the button on the SSAS is pressed. Note 2: The message shown below appears when the cancellation is made. CAUTION 14-04-10 05:40 (UTC) INF: SSAS UNIT activation has been canceled. Pop-up message <Within 30 seconds after the button is pressed> Press the button on the SSAS again to turn it off. <More than 30 seconds after the button is pressed> [Method 1] Note : Do the following procedure on the terminal unit of FELCOM15/18 or PC of FELCOM16/19. 1. Switch to the SSAS manager mode, referring to paragraph 3.1.2. 2. In case of FELCOM16/18/19, press [F8], [1] to show the [System Setup] menu. In case of FELCOM15, press [F8], [2] to show the [System Setup] menu. 3. Press [↓] to choose Command Window and then press the [Enter] key. 4. Type “terminate ssas alert” (without quotation marks) in the Enter JOB No. field and then press the [Enter] key. [Method 2] 1. Turn the button of all SSAS IC-307s off. 2. Press the button ON→OFF→ON→OFF on one of the above-mentioned SSAS IC-307s 15 3.4 Testing the Button Note 1: An actual SSAS report cannot be transmitted during the testing. Note 2: The equipment must be in the SSAS manager mode to conduct the test. FELCOM 15/18 <In case of not sending the test report> 1. Press the [F7] key to display the Options menu. 2. Press one of the following keys to display the Test menu: Operating mode is Inmarsat-C: [7] key FELCOM 18: [8] key Operating mode is EGC receiver: [6] key Test 1. PV Test 2. PV Test Result 3. Diagnostic Test 4. Distress/SSAS Button Test 3. Press the [4] key. Options Test 1. Login 2.1.Logout PV Test Distress/SSAS Button Test 3.2.Abort PV Test Result Start 4.3.Select NCS Self Test 5.4.Ocean Region Distress Alarm Button Test No Yes 6. Test 4. Press the [Enter] key to start the test. Options Test 1. Login 2.1.Logout PV Test Distress/SSAS Button Test 3.2.Abort PV Test Result 4.3.Select NCS Distress/SSAS buttons are under test mode. Self Test CAUTION 5.4.Ocean Region Press any key to escape. Distress Alarm Button Test INF: SSAS6.Buttons Test entered into TEST MODE. <Press ESC key to continue> The display shows the message (in red) “Distress/SSAS buttons are under test. Cancel the test mode if a real distress/SSAS needs to sent.” appears. 5. Open the button cover on the No.1 SSAS. 6. Push the button in ( ). The CAUTION window displays the message “SSAS UNIT works correctly.” appears if the unit is functioning properly. Turn the button of the No. 1 SSAS off ( ) within 30 seconds. Note: Any message does not appear when turning the button off. 7. Close the button cover on the No.1 SSAS. Note: To test the No. 2 and No. 3 SSAS repeat steps 5 to 9. 16 8. To escape from the test, press the [Esc] key twice on the terminal unit. The test mode is stopped and the message shown below appears to notify you that normal operation has been restored. CAUTION INF: SSAS Buttons returned to NORMAL OPERATION. <Press ESC key to continue> If the button remains pushed in ( ), the message “Please return the SSAS button into OFF-STATE.” appears. Push the button to pop it out. 9. Press the [Esc] key three times to return to the standby display. Note:If the button is left pushed in ( ) when the terminal unit is turned on, the equipment displays “Please return the SSAS button into OFF-STATE.” Push the button again to turn off ( ) the button. <In case of sending the test report> 1. Press the [F7] key to display the Options menu. 2. Press one of the following keys to display the Test menu: Operating mode is Inmarsat-C: [7] key FELCOM 18: [8] key Operating mode is EGC receiver: [6] key Test 1. PV Test 2. PV Test Result 3. Diagnostic Test 4. Distress/SSAS Button Test 3. Press the [4] key. Options Test 1. Login 2.1.Logout PV Test Distress/SSAS Button Test 3.2.Abort PV Test Result Start 4.3.Select NCS Self Test 5.4.Ocean Region Distress Alarm Button Test No Yes 6. Test 4. Press the [Enter] key to start the test. Options Test 1. Login 2.1.Logout PV Test Distress/SSAS Button Test 3.2.Abort PV Test Result 4.3.Select NCS Distress/SSAS buttons are under test mode. Self Test CAUTION 5.4.Ocean Region Press any key to escape. Distress Alarm Button Test INF: SSAS6.Buttons Test entered into TEST MODE. <Press ESC key to continue> The display shows the message (in red) “Distress/SSAS buttons are under test. Cancel the test mode if a real distress/SSAS needs to sent.” appears. 17 5. Open the button cover on the No.1 SSAS. 6. Push the button in ( ). The CAUTION window displays the message “SSAS UNIT works correctly.” appears if the unit is functioning properly. 7. 30 seconds after the button is pushed in the SSAS test report is automatically sent to the station(s) whose Mode set on the SSAS Report window is “Real+Test” or Test Only”. When starting the transmission, [Current State] indicates [SENDING] at the left bottom on the screen. Current State : SENDING DCE F18 Ver.01 Returning NCS:POR LOGIN REC. MESSAGE EXIST 94-08-11 10:11(UTC) LAT: 10:00.00N LON: 000:00.00E Note: The SSAS test report is not sent to the station(s) whose Mode set on the SSAS Report window is “Real Only”.. 8. Turn the button of the No. 1 SSAS off ( ) 9. Close the button cover on the No.1 SSAS. Note: To test the No. 2 and No. 3 SSAS repeat steps 5 to 9. 10. To escape from the test, press the [Esc] key twice on the terminal unit. The test mode is stopped and the message shown below appears to notify you that normal operation has been restored. CAUTION INF: Distress/SSAS Buttons returned to NORMAL OPERATION. <Press ESC key to continue> If the button remains pushed in ( ), the message “Please return the SSAS button into OFF-STATE.” appears. Push the button to pop it out. 11. Press the [Esc] key three times to return to the standby display. Note:If the button is left pushed in ( ) when the terminal unit is turned on, the equipment displays “Please return the SSAS button into OFF-STATE.” Push the button again to turn off ( ) the button. 12. When the SSAS test report is successfully sent, “Successful Sending message” and “DELIVERY CONFIRMED:A specified email address” messages are shown below. CAUTION 94-08-11 00:38(UTC) Successful Sending message. 94-08-11 00:41(UTC) DELIVERY CONFIRMED: [email protected] <Press ESC key to continue> 13. Confirm that the SSAS test report is sent to the station(s). 18 FELCOM 16/19 (no PC) Turn off communication unit. Turn on button of No. 1 SSAS. Turn on communication unit. 30 s POWER, LOGIN and TX lamps flash in that order. Send SSAS test report? No (within 30 s) Yes (after 30 s) SSAS report is sent to station(s) whose mode is "Real+Test" or "Test Only". (See paragraph 3.2.) Lamps flash rapidly during TX. It takes 2 to 5 minutes to send one message. Test successful? Test TX No ERROR lamp flashes rapidly. Yes POWER, LOGIN and TX lamps flash in that order. ERROR lamp also flashes. Turn off button of No. 1 SSAS. The POWER, LOGIN and TX lamps flash in that order. Turn on button of No.2 SSAS. Test TX Turn off button of No.2 SSAS. Turn communication unit off and on again. Note: If a 3rd SSAS unit is installed test it by procedure used to test No.2 unit. 19 FELCOM 16/19 (by PC) 1. Press the [F7] key to display the Options menu. 2. Press the [7] key ([6] key when the FELCOM functions as an EGC receiver) to display the Test menu. For FELCOM 19, press the [8] key. Test 1. PV Test 2. PV Test Result 3. Diagnostic Test 4. SSAS Button Test 3. Press the [4] key. Options Test 1. Login SSAS Button Test 2.1.Logout PV Test 3.2.Abort PV Test Result Start 4.3.Select NCS Self Test 5.4.Ocean Region Distress Alarm Button Test No Yes 6. Test 4. Press the [Enter] key to start the test. Options Test 1. Login 2.1.Logout PV Test Distress/SSAS Button Test 3.2.Abort PV Test Result 4.3.Select NCS Distress/SSAS buttons are under test mode. Self Test CAUTION 5.4.Ocean Region Press any key to escape. Distress Alarm Button Test INF: SSAS6.Buttons Test entered into TEST MODE. <Press ESC key to continue> Test mode The display shows the message (in red) “SSAS buttons are under test. Cancel the test mode if a real SSAS alert needs to sent.” appears. 5. Open the button cover on the No. 1 SSAS. 6. Push the button in (ON). The CAUTION window displays the message “SSAS UNIT works correctly.” appears if the unit is functioning properly. 7. 30 seconds after the button is pushed in the SSAS test report is automatically sent to the station(s) whose Mode set on the SSAS Report window is “Real+Test” or Test Only”. 8. Turn the button of the No. 1 SSAS off ( ). Note: To test the No. 2 and No. 3 SSAS repeat steps 6-8. 20 9. To escape from the test, press the [Esc] key twice on the terminal unit. The test mode is stopped and the message shown below appears to notify you that normal operation has been restored. CAUTION INF: SSAS Buttons returned to NORMAL OPERATION. <Press ESC key to continue> Further, because the button remains pushed in ( SSAS button into OFF-STATE.” appears. ), the message “Please return the 10. Push the button again to pop it out ( ). 11. Close the button cover. 12. Press the [Esc] key three times to return to the standby display. Note: If the button is left pushed in ( ) when the communication unit is turned on, the equipment will go into the test mode if the SSAS is not transmitting repeatedly. To return to the standby display, push the button again to pop it out ( ) and then turn the communication unit off and on again. 3.5 SSAS Report Test You can test for successful transmission of the SSAS report to the address you specify, without using the button. The test report message states “!!! Test Call !!!” to alert the receiver of the message that it is a test call. Note: This function is only available in the SSAS manager mode. Switch to this mode (see paragraph 3.1.2) and then follow this procedure. 1. 2. 3. 4. 5. 6. Access the Report Destination Menu, referring to section 3.2. Set destination where to transmit the test. Press the [↑] key to choose Status and then press the [Enter] key. Press the [↓] key to choose TEST and then press the [Enter] key. Press the [Esc] key to open the Update window. Yes is selected; press the [Enter] key. The test report is transmitted. After it is transmitted, “Status” is automatically set to ON. 7. Press the [Esc] key twice to return to the standby display. 21 4. WATERPROOFING KIT (OPTION) To mount the IC-305 and IC-307 on a bulkhead, use the optional waterproofing kit to keep water splash out of the units. Note: This kit cannot be used if the IC-305 or IC-307 is mounted face upward. OP-xx (For IC-305) Name Type Code No. Qty Fixing Tape 24-009-1225 100-366-200-10 2 OP-xx (For IC-307) Name Waterproofing Cover Fixing Tape Type 16-023-5501 24-009-1225 Code No. 100-374-950-10 100-366-200-10 Qty 1 2 1. Unfasten four screws to remove cover of IC-305/IC-307. 2. Attach supplied fixing to the underside of the cover as shown in the illustration below. Fixing tape 3. Attach the cover. 4. For IC-307, remove the seal from the waterproofing cover and attach the cover as shown in the illustration below. 22 D-1 Mar.03'05 D-2 17/May/2012 Y.NISHIYAMA D-3 6/Oct/2010 Y. NISHIYAMA 16/Jun/2014 H.MAKI D-4 1 2 3 4 5 6 S-1 アンテナユニット ANTENNA UNIT IC-115 TPA5FB0.4NJ5 FBA-5DFB,0.4m A ケーブル/コネクタは選択 SELECT CABLE & CONNECTOR 12D-SFA-CV,100m,φ20: N-P-12DSFA 8D-FB-CV,50m,φ14.3: N-P-8DFB 5D-FB-CV,30m,φ10.7: N-P-5DFB TNCP-NJ RW-4747 0.3m ターミナルユニット TERMINAL UNIT IC-215 *7 ANT TP5FBAW-5DFBB,30m,φ7.7 P P DGPS BNC PLUG *1 COAX. CABLE(50Ω) DGPSデコーダー DGPS DECODER 2B02 16P0208A キーボード KEYBOARD 船内LAN (HUB) パソコンなど LAN(HUB) OR PC, ETC. 1.6m P B P 24VDC RH12BPG-3S VCTF-0.75x3C,5m,φ7 アカ RED 1 +24V (16S0084) 2 0V クロ BLK 3 GND シロ WHT プリンタ PRINTER PP-510 1 *2 36 *4 C MJ-A3SPF0018-050ZC,5m,φ11 12-24 VDC 100-115/ *1 200-230 VAC DPYC-2.5 1φ,50/60Hz *1 24 VDC DPYC-4 PE *1 IV-2sq. 保護アース 1 2 3 4 5 6 7 8 LAN E_TD_P E_TD-N E_RD_P NC NC E_RD_N NC NC *3 17JE-23250 -02(D8C) 16S0184,3m,φ8 24 VDC KEYBOARD KDAT NC GND +5V KCLK NC RJ-45 STP CABLE(CAT5) *1 PC: CROSS CABLE HUB: STRAIGHT CABLE *3 57-3036 1 2 3 4 5 6 DTE PRINTER 1 RXD TXD 25 GND *4 2B03 16P0209 FUSE *3 15A(12V) 12-24VDC MJ-A3SPF 7A(24V) 1 DC(+) シロ WHT 2 DC(-) クロ BLK 3 GND 2B10 AC IN + DC - IN E AC/DC 24VDC + 電源ユニット OUT AC/DC POWER SUPPLY UNIT PR-240 *2 JUNCTION Vcc(ALM) GND TD/RD-A TD/RD-B NC TD-A TD-B RD-A RD-B GND DMC_OUT-H DMC_OUT-C DMC_CHECK DMC_IN-C DMC_CTRL 16P0214 銅板 COPPER STRAP W=30,1.2m 接続箱 JUNCTION BOX IC-315 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 *3 Dsub15P 2m 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 *1 TTYCS-4 P P TTYCS-1(*1) OR CO-0.2x2P(*2) GND P NOTE *1. SHIPYARD SUPPLY. *2. OPTION. *3. FITTED AT FACTORY. *4. GROUND THRU CONNECTOR CLAMP. *5. TB BOARD (16P0116) REQUIRED. *6. CHANGE SETTING OF JUMPER IN IC-307 TO TERMINATE. *7. DO NOT SHORTEN ANTENNA CABLE. TTYCS-4(*1) OR CO-0.2x5P(*2) RXD TXD DTR GND DSR RTS CTS NC RXD TXD 0V EGCプリンタ EGC PRINTER PP-505 (+) 1 *2 7 NC 1 2 3 4 5 RXD TXD NC NC 0V *2 (-) P P *1 TTYCS-1 3 4 P 保安警報発呼器 SSAS ALERT UNIT IC-307 (No.2) *2 *6 1 2 3 4 5 6 P P INMARSAT No.1/2 1 TR-A 2 TR-B アラームユニット ALARM UNIT 3 FG IC-350 *2 保安警報発呼器 SSAS ALERT UNIT IC-307 (No.3) *2 *6 1 2 3 4 5 6 合計 :最大200m TOTAL: UP TO 200m 1 2 3 4 5 6 7 *2 FM14-7P FM14-7P CO-0.2x5P,MAX.100m 1 2 P 3 P 4 5 6 7 *4 *4 20/Nov/2012 CHECKED 20/Nov/2012 APPROVED 20/Nov/2012 SCALE T.YAMASAKI T.TAKAHASHI RXD-H TXD-H FG TXD-C RXD-C +9V NC EGCプリンタ EGC PRINTER PP-505 *2 *5 (+) (-) 1 2 08S0157,3m MASS C5635-C01- T 24VDC GND 08S0087 TITLE 名称 FELCOM 15 インマルサットC船舶地球局 相互結線図 Y.NISHIYAMA kg DWG No. 24VDC GND 08S0087 FM14-5P I/F BOX OP16-14 08S0157,3m 2 *4 DRAWN CO-0.2x2P: CO-SPEVV-SB-C 0.2x2P,φ10.5 CO-0.2x5P: CO-SPEVV-SB-C 0.2x5P,φ13.5 SSAS_OUT-H NC SSAS_CHECK SSAS_IN-C SSAS_CTRL GND IC-315 最大3台まで接続可能。 MAX.3 SETS AVAILABLE. パソコン PC NC *2 FM14-7P CO-0.2x2P,MAX.15m 1 2 3 *4 D 選択 SELECT 17JE-23090 -02(D8C) 1 2 3 4 5 6 7 8 9 *4 注記 *1)造船所手配。 *2)オプション。 *3)工場にて取付済み。 *4)コネクタクランプでアースに落とす。 *5)TB基板(16P0116)が必要。 *6)終端のIC-307はジャンパー設定を変更する。 *7)アンテナケーブルは切断して使用しないこと。 IC-350を接続するとき(IC-305との共用不可) CONNECTION FOR IC-350 (DO NOT USE W/ IC-305) *4 DTE RXD TXD 1 2 3 4 5 6 P 2 3 4 5 6 7 8 9 *4 遭難警報器 IC-305 DISTRESS ALERT/ RECEIVED CALL UNIT 16P0213C 1 VCC 2 GND 3 TD/RD-A 4 TD/RD-B 5 FG 保安警報発呼器 SSAS ALERT UNIT IC-307 (No.1) *2 *6 TTYCS-4(*1) OR CO-0.2x5P(*2) 17JE-23090 17JE-13090 *2 -02(D8C) 17JE-573-10,5m,φ8 -02(D8C) CO-0.2x5P,MAX.15m 1 1 2 3 4 5 6 7 8 9 航法装置 NAV EQUIPMENT アラームユニットIC-306 ALARM UNIT 16P0213D 1 VCC 2 GND 3 TD/RD-A 4 TD/RD-B 5 FG NAME INMARSAT-C MES INTERCONNECTION DIAGRAM FURUNO ELECTRIC CO., LTD. C B A *6 TPA5FB0.4NJ5 FBA-5DFB,0.4m *1 DPYC-4 PE *1 IV-2sq. 保護アース AC/DC 24VDC + 電源ユニット OUT AC/DC POWER + DC SUPPLY UNIT - IN PR-240 *2 AC IN NOTE *1. SHIPYARD SUPPLY. *2. OPTION. *3. FITTED AT FACTORY. *4. STANDARD SUPPLY FOR SSAS SPEC. *5. CHANGE SETTING OF JUMPER IN IC-307 TO TERMINATE. *6. DO NOT SHORTEN ANTENNA CABLE. 注記 *1)造船所手配。 *2)オプション。 *3)工場にて取付済み。 *4)SSAS仕様時標準支給。 *5)終端のIC-307はジャンパー設定を変更する。 *6)アンテナケーブルは切断して使用しないこと。 24 VDC 100-115/ *1 200-230 VAC DPYC-2.5 1φ,50/60Hz TNCP-NJ 2B02 16P0208B ANT 3 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 *3 D-sub15P DWG No. SCALE 1/Apr/2010 MASS kg Y.NISHIYAMA T.TAKAHASHI T.YAMASAKI C5638-C01- L 30/Mar/2010 CHECKED 30/Mar/2010 APPROVED DRAWN CO-0.2x5P: CO-SPEVV-SB-C 0.2x5P,φ13.5 2m 接続箱 IC-315 JUNCTION BOX *4 1 Vcc 2 GND 3 TD/RD-A 4 TD/RD-B 5 NC 6 TD-A 7 TD-B 8 RD-A 9 RD-B 10 GND 11 DMC_OUT-H 12 DMC_OUT-C 13 DMC_IN-H 14 DMC_IN-C 15 DMC_CTR *3 *3 17JE-13090 17JE-23090 -02(D8C) -02(D8C) *2 17JE-573-10,5m,φ8 1 1 2 2 3 3 4 4 5 5 6 6 7 7 8 8 9 9 銅板 COPPER STRAP W=30,1.2m Vcc(6.5V) GND TX/RX-A TX/RX-B NC 2B10 16P0227 NC NC NC NC NC SSAS_OUT-H NC SSAS_CHECK SSAS_IN-C SSAS_CTRL SSAS GND RXD TXD 通信制御ユニット COMMUNICATION UNIT IC-216 DTE 2 FUSE 10A:12VDC *3 12-24VDC FM-C3FP 5A:24VDC 1 DC(+) アカ RED 2 DC(-) クロ BLK 3 GND TP5FBAW-5DFBB,30m,φ7.7 TP58A15W-RG58,15m,φ5 ケーブル/コネクタは選択 SELECT CABLE & CONNECTOR 12D-SFA-CV,100m,φ20: N-P-12DSFA 8D-FB-CV,50m,φ14.3: N-P-8DFB 5D-FB-CV,30m,φ10.7: N-P-5DFB 12-24 VDC FM-C3FPS-002,3.5m,φ7.5 RW-4747 0.3m アンテナユニット ANTENNA UNIT IC-116 1 NC RXD TXD DTR GND DSR RTS CTS NC P P パソコン PC P P 保安警報発呼器 SSAS ALERT UNIT IC-307 (No.2) *4 *5 1 2 3 4 5 6 NAME 名称 TITLE P 2 3 4 5 6 最大3台まで接続可能 MAX. 3 UNITS AVAILABLE P 保安警報発呼器 SSAS ALERT UNIT IC-307 (No.3) *2 *5 1 INTERCONNECTION DIAGRAM INMARSAT MINI-C MES 相互結線図 FELCOM 16 インマルサットMINI-C携帯移動地球局 TTYCS-4(*1) OR CO-0.2x5P(*2) 合計:最大200m TOTAL: UP TO 200m 保安警報発呼器 SSAS ALERT UNIT IC-307 (No.1) *4 1 SSAS_OUT-H 2 NC 3 SSAS_CHECK 4 SSAS_IN-C 5 SSAS_CTRL 6 GND 4 S-2 1 2 4 3 5 S-3 6 アラームユニット 1 2 3 4 5 P P アンテナユニット ANTENNA UNIT IC-118 TPA5FB0.4NJ5 12D-SFA-CV,100m,φ20: N-P-12DSFA FBA-5DFB,0.4m 8D-FB-CV,40/50m,φ14.3: N-P-8DFB 5D-FB-CV,30m,φ10.7: N-P-5DFB ターミナルユニット TERMINAL UNIT IC-218 JUNCTION TNCP-NJ A ANT TP5FBAW-5DFBB,30m,φ7.7 DGPS DGPSデコーダー DGPS DECODER COAX. CABLE(50Ω) BNC USB A TYPE キーボード KEYBOARD RH12BPG-3S VCTF-0.75x3C,5m,φ7 (16S0084) 24 VDC (+) アカ RED (-) クロ BLK GND シロ WHT B 3 *1 12 VDC DC/DCコンバータ DC/DC CONVERTER 100-115/ *1 200-230 VAC DPYC-2.5 1φ,50/60Hz *1 24 VDC DPYC-4 PE *1 IV-2sq. 保護アース AC IN + DC - IN E 4 17JE-23250 57-3036 -02(D8C) プリンタ 36 25 16S0184 PRINTER 3m,φ8 PP-510 *2 または OR H230817-1(*2) 防水仕様ケーブル WATERPROOF CABLE MJ-A3SPF0018-050Z 5m,φ11 12-24VDC 1.5m AC/DC 24VDC + 電源ユニット OUT AC/DC POWER SUPPLY UNIT PR-240 *2 15A(12V) MJ-A3SPF 7A(24V) シロ WHT 1 クロ BLK 2 3 PRINTER Vcc(ALM) GND TD/RD-A TD/RD-B NC ALM-H ALM-C RD-A RD-B GND SSAS_OUT-H SSAS_OUT-C SSAS_CHECK SSAS_IN-C SSAS_CTRL 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 17JE-23150 -02(D8C) 2m 接続箱 JUNCTION BOX IC-318 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 VCC ALARM UNIT GND IC-306 TD/RD-A *2 TD/RD-B GND IC-350を接続するとき(IC-305との共用不可) CONNECTION FOR IC-350 (DO NOT USE W/ IC-305) 遭難警報器 DISTRESS ALERT/ *2 RECEIVED CALL UNIT TTYCSLA-4(*1) OR CO-0.2x5P(*2) P P TTYCSLA-1(*1) OR CO-0.2x2P(*2) TTYCSLA-1(*1) OR CO-0.2x2P(*2) 1 2 3 4 5 IC-305 VCC GND TD/RD-A TD/RD-B GND 選択 SELECT P P 1 2 3 4 5 6 3 4 TTYCSLA-1(*1) OR CO-0.2x2P(*2) IC-307(No.2) SSAS_OUT-H NC SSAS_CHECK SSAS_IN-C SSAS_CTRL GND P P 1 *2 *3 *4 2 3 4 5 6 *1 IV-2sq. LAN RJ45 8 *1 STP(CAT5) DC IN IC-307(No.3) P P 1 2 3 4 5 6 *2 *3 最大3台まで接続可能 MAX. 3 UNITS AVAILABLE. TTYCSLA-4(*1) OR CO-0.2x5P(*2) 合計 :最大200m TOTAL: UP TO 200m パソコン/HUB PC OR HUB INMARSAT No.1/2 1 TR-A 2 TR-B アラームユニット ALARM UNIT 3 FG IC-350 アラームシステム ALARM SYSTEM 航法装置 保安警報発呼器 NAV EQUIPMENT SSAS ALERT UNIT IC-307 *2 *3 *4 TTYCSLA-4(*1) OR CO-0.2x5P(*2) IC-318 DC+ DCGND 銅板 COPPER STRAP W=30,1.2m IC-218 JUNCTION 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 C 防水仕様ケーブル WATERPROOF CABLE *2 XM-FD-361,2m アオ BLU チャ BRN ムラサキ PPL ハイ GRY ミドリ GRN YEL キ ORG ダイ モモ PNK ウスミドリ L-GRN シロ/クロ WHT/BLK シロ/アカ WHT/RED クロ BLK アカ RED ミズ L-BLU 接続箱 JUNCTION BOX IC-318 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 D 注記 *1)造船所手配。 *2)オプション。 *3)終端のIC-307はジャンパー設定を変更する。 *4)SSAS仕様のとき標準構成。 NOTE *1: SHIPYARD SUPPLY. *2: OPTION. *3: CHANGE SETTING OF JUMPER IN IC-307 TO TERMINATE. *4: STANDARD CONFIGURATION FOR SSAS. DRAWN CO-0.2x2P: CO-SPEVV-SB-C 0.2x2P,φ10.5 CO-0.2x5P: CO-SPEVV-SB-C 0.2x5P,φ13.5 12/Dec/2012 T.YAMASAKI CHECKED 12/Dec/2012 H.MAKI APPROVED 18/Dec/2012 Y.NISHIYAMA SCALE MASS kg DWG No. C5674-C01- D REF.No. 16-023-3001-1 TITLE FELCOM 18 名称 インマルサット-C 船舶地球局 相互結線図 NAME INMARSAT-C MES INTERCONNECTION DIAGRAM C B A PE *1 IV-2sq. 保護アース DPYC-4 AC IN + DC - IN E AC/DC 24VDC + 電源ユニット OUT AC/DC POWER SUPPLY UNIT PR-240 *2 2 DC+ DCGND DC IN ANT 8 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 RJ45 *1 STP(CAT5) 17JE-23150 -02(D8C) 2m 銅板 COPPER STRAP W=30,1.2m LAN Vcc(ALM) GND TD/RD-A TD/RD-B NC ALM-H ALM-C RD-A RD-B GND SSAS_OUT-H SSAS_OUT-C SSAS_CHECK SSAS_IN-C SSAS_CTRL 通信制御ユニット COMMUNICATION UNIT IC-219 JUNCTION NOTE *1: SHIPYARD SUPPLY. *2: OPTION. *3: CHANGE SETTING OF JUMPER IN IC-307 TO TERMINATE. *4: STANDARD CONFIGURATION FOR SSAS. 注記 *1)造船所手配。 *2)オプション。 *3)終端のIC-307はジャンパー設定を変更する。 *4)SSAS仕様のとき標準構成。 24 VDC 100-115/ *1 200-230 VAC DPYC-2.5 1φ,50/60Hz *1 12-24VDC TNCP-NJ 10A(12V) MJ-A3SPF 5A(24V) シロ WHT 1 クロ BLK 2 3 TP5FBAW-5DFBB,30m,φ7.7 12D-SFA-CV,100m,φ20: N-P-12DSFA 8D-FB-CV,50m,φ14.3: N-P-8DFB 5D-FB-CV,30m,φ10.7: N-P-5DFB TPA5FB0.4NJ5 FBA-5DFB,0.4m MJ-A3SPF0016-035 3.5m アンテナユニット ANTENNA UNIT IC-119 1 *1 IV-2sq. P TTYCSLA-4(*1) OR CO-0.2x5P(*2) 合計 :最大200m TOTAL: UP TO 200m SSAS ALERT UNIT IC-307 *2 *3 *4 1 SSAS_OUT-H 2 NC 3 SSAS_CHECK 4 SSAS_IN-C 5 SSAS_CTRL 6 GND 保安警報発呼器 アラームシステム ALARM SYSTEM 航法装置 NAV EQUIPMENT 31/May/2012 DWG.No. SCALE C5675-C01- D kg Y.NISHIYAMA H.MAKI T.YAMASAKI MASS 31/May/2012 CHECKED 31/May/2012 APPROVED DRAWN REF.No. 16-023-4001-1 CO-0.2x2P: CO-SPEVV-SB-C 0.2x2P,φ10.5 CO-0.2x5P: CO-SPEVV-SB-C 0.2x5P,φ13.5 P TTYCSLA-4(*1) OR CO-0.2x5P(*2) TTYCSLA-1(*1) OR CO-0.2x2P(*2) TTYCSLA-1(*1) OR CO-0.2x2P(*2) パソコン/HUB PC OR HUB 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 接続箱 JUNCTION BOX IC-318 *2 *4 3 NAME 名 称 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 1 2 3 4 5 6 *2 *3 ミドリ GRN YEL キ ORG ダイ モモ PNK ウスミドリ L-GRN シロ/クロ WHT/BLK シロ/アカ WHT/RED クロ BLK アカ RED ミズ L-BLU 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 接続箱 JUNCTION BOX IC-318 最大3台まで接続可能 MAX. 3 UNITS AVAILABLE. P 防水仕様ケーブル WATERPROOF CABLE *2 XM-FD-361,2m アオ BLU チャ BRN ムラサキ PPL ハイ GRY P IC-307(No.3) INTERCONNECTION DIAGRAM INMARSAT MINI-C MES 相互結線図 FELCOM 19 インマルサットMINI-C携帯移動地球局 JUNCTION IC-219 P TITLE P 1 *2 *3 *4 2 3 4 5 6 IC-307(No.2) 4 S-4