...

2 - DAQLOG Systems Ltd

by user

on
Category: Documents
64

views

Report

Comments

Transcript

2 - DAQLOG Systems Ltd
High Speed Digital Data Recorder
高速デジタルデータレコーダ
SIR-1000W
Channel Expansion Unit
チャンネル拡張ユニット
SCX-16W
Read all instructions carefully before use.
To make full use of the unit's functions, read this manual carefully and keep it properly for
future reference.
お買い上げいただき、ありがとうございます。
ご使用の前に、この取扱説明書を必ずお読みください。
ご使用に際しては、この取扱説明書どおりお使いください。
お読みになった後は、後日お役に立つこともございますので、必ず保管してください。
Advanced
I n t e l l i ge n t
Ta p e
Instruction Manual/ 取扱説明書
2nd Edition/ 第2版
[ For U.S.A. and Canada ]
[For EU and EFTA countries]
THIS CLASS A DIGITAL DEVICE COMPLIES WITH
PART15 OF THE FCC RULES AND THE CANADIAN
ICES-003. OPERATION IS SUBJECT TO THE
FOLLOWING TWO CONDITIONS.
(1) T H I S D E V I C E M A Y N O T C A U S E H A R M F U L
INTERFERENCE, AND
(2) THIS DEVICE MUST ACCEPT ANY INTERFERENCE
RECEIVED, INCLUDING INTERFERENCE THAT
MAY CAUSE UNDERSIGNED OPERATION.
CE Notice
CET APPAREIL NUMERIQUE DE LA CLASSE A EST
CONFORME A LA NORME NMB-003 DU CANADA.
[For the customers in Australia]
Making by the symbol CE indicates compliance of the
EMC directive and the Low-voltage directive of the
European Community. Such marking is indicative
meets of exceeds the following technical standards.
EN 55 011 Group 1 Class A / 91 :
"Limits and methods of measurement of
electromagnetic disturbance characteristics of
industrial, scientific and medical (ISM) radio-frequency
equipment"
EN 61 000-3-2 / 95 :
"Limits for harmonic currents emissions (equipment
input current ≦ 16 A per phase)"
EN 50 082-2 / 95 :
Australian EMC Notice
This product complies with the following Australian
EMC standards.
AS/NZS 4252.1 /94 EMC Generic Immunity Part1
AS/NZS 2064 /92 Emission Standard for ISM
Equipment
"Electromagnetic compatibility - Generic immunity
standard Part 2 : Industrial environment"
EN 61 010-1 A1+A2 :
"Safety requirements for electrical equipment for
measurement, control and laboratory use Part 1:
General requirements"
Entsorgungshinweis: Bitte werfen Sie nur entladene
Batterien in die Sammelboxen beim Handel oder den
Kommunen. Entladen sind Batterien in der Regel dann,
wenn das Gerät abschaltet und signalisiert "Batterie
leer" oder nach längerer Gebrauchsdauer der Batterien
"nicht mehr einwandfrei funktionier t". Um
sicherzugehen, kleben Sie die Batteriepole z.B. mit
einem Klebestreifen ab oder geben Sie die Batterien
einzeln in einen Plastikbeutel.
Precautions
This manual uses the following indications:
!
WARNING
Indicates a potentially hazardous situation which, if not avoided, may result in
serious injury or death.
! CAUTION
Indicates a potentially hazardous situation which, if not avoided, may result in minor
or moderate injury and/or property damage.
Note
Indicates a point that should be noted or some additional information.
Important
For safety reasons, please read and understand the following descriptions before use.
(This manual describes the recorder which version is more than or equal 30.)
If there is any abnormal phenomena during installation or operation, disconnect the
power cord or remove battery pack and contact service engineer person immediately.
It is dangerous to use the unit if it is not operating normally.
General
! WARNING
• No user-serviceable parts are inside the unit. Removing the covers may expose
you danger.
• Never push objects of any kind into the unit through the slots.
• Do not place any liquids on the top of the unit.
• Should any object or liquid fall into the unit, turn the power OFF and unplug
the unit and call service engineer person to check it before using again.
• The SIR-1000W and SCX-16W should be used indoors or under similar
conditions.
• Clean the recorder by wiping it with a dry cloth.
Installation
! WARNING
• Be careful never to drop the unit when handling, unboxed or boxed. If the unit
is dropped, turn the power OFF and unplug the unit and call service engineer
person to check it before using again.
• Be sure that the unit is firmly positioned on its supporting surface. The unit
cause an injury if it falls or dropped.
• To allow adequate air circulation, do not block the ventilation of the unit.
• Do not place the unit or other heavy objects on the power cord. If damaged,
the cord may cause fire or electric shock.
i
! CAUTION
• This unit is designed and shipped for worldwide use, so that various accessories
are supplied. Use proper accessories according to your area.
• Keep the unit away from strong magnetic fields such as high voltage
transformers, speakers, and electric motors.
• When receives strong outer noises, the unit may operate improperly.
• Do not locate the unit in a dusty, hot or humid place.
• Do not place heavy objects on the top of the unit, otherwise it may fall and
cause an injury.
• To disconnect the power cord or signal cable, always pull it by the plug.
Pulling wire may cause it to be damaged resulting fire or electric shock.
• Keep the power cord or signal cable away from where people might step on it
or trip over it.
• Be sure that the attached AC power cord is firmly connected.
There is a protective ground wire in attached AC power cord.
Operation
! WARNING
• Be sure operate the unit only with the specified power supply. Use of an
incorrect voltage will cause severe damage.
• Be sure to input to the unit only the specified signal voltage.
• Replace only with specified type and rated fuse.
! CAUTION
• Disconnect the power cord or remove battery pack from the unit if it is not in
use.
• Disconnect the power cord before replaceing fuse.
ii
Contents
1
Overview .................................................................................................. 1-1
1-1 Introduction ..................................................................................... 1-1
1-2 Major Features ................................................................................ 1-2
2
Tape Format and Basic Operations ...................................................... 2-1
2-1 Tape Format .................................................................................... 2-1
2-2 TOC ................................................................................................ 2-2
2-3 MIC (Memory In Cartridge) ........................................................... 2-2
2-4 Formatting ....................................................................................... 2-2
2-5 Eject ................................................................................................ 2-3
2-6 Overwriting Data ............................................................................ 2-3
2-7 ID Block .......................................................................................... 2-3
3
Names and Functions of Parts ............................................................... 3-1
3-1 Front Panel ...................................................................................... 3-1
3-2 Rear Panel ..................................................................................... 3-22
3-3 Left Side Panel .............................................................................. 3-29
3-4 Right Side Panel ........................................................................... 3-30
4
Preparations ............................................................................................ 4-1
4-1 Connecting the Power Supply ........................................................ 4-1
4-2 Cartridges ........................................................................................ 4-4
4-3 Self-Check ...................................................................................... 4-8
4-4 Error Codes ................................................................................... 4-10
4-5 Warning Display ........................................................................... 4-12
4-6 Source Mode/Tape Mode ............................................................. 4-15
4-7 Fan Control Mode ......................................................................... 4-16
5
Data Recording/Playback ....................................................................... 5-1
5-1 Connecting the Signals ................................................................... 5-1
5-2 Settings for Recording .................................................................... 5-2
5-3 Recording Data ............................................................................... 5-8
5-4 Data Playback ............................................................................... 5-12
6
Recording and Playback Voice Annotations ........................................ 6-1
7
Recording and Playback AUX Digital Data ......................................... 7-1
8
Recording and Playback AUX Analog Data ......................................... 8-1
8-1 Recording and Playback IRIG-B Time Code Signal ...................... 8-2
8-2 Recording and Playback AUX Analog Data .................................. 8-4
9
Trigger Recording ................................................................................... 9-1
10
Search ..................................................................................................... 10-1
11
External Control ................................................................................... 11-1
–1–
12
RS-232C Control ................................................................................... 12-1
12-1 Interface Specifications................................................................. 12-1
12-2 Command Overview ..................................................................... 12-2
12-3 Command Details ......................................................................... 12-4
13
Guard Frames ....................................................................................... 13-1
14
Battery Pack .......................................................................................... 14-1
15
Remote Control Unit ............................................................................. 15-1
16
Channel Expansion Unit ....................................................................... 16-1
16-1 Prior to Operation ......................................................................... 16-1
16-2 Names and Functions of Parts ...................................................... 16-2
16-3 Connecting to the SIR-1000W ...................................................... 16-5
16-4 Operation ...................................................................................... 16-7
17
Synchronizing Mode ............................................................................. 17-1
17-1 Before Operation .......................................................................... 17-1
17-2 Connecting and Setting ................................................................. 17-2
17-3 Operation ...................................................................................... 17-3
18
Specifications ......................................................................................... 18-1
18-1 Cartridges ...................................................................................... 18-1
18-2 Tape Transport System ................................................................. 18-1
18-3 Recording/Playback System ......................................................... 18-1
18-4 Analog Channels ........................................................................... 18-2
18-5 AUX Digital Channel (AUX-1) .................................................... 18-3
18-6 AUX Analog Channel (AUX-2) ................................................... 18-4
18-7 Voice Annotation Channel ........................................................... 18-4
18-8 Operation System .......................................................................... 18-5
18-9 Monitor System ............................................................................ 18-6
18-10 Power Supply System ................................................................... 18-7
18-11 Dimensions and Mass ................................................................... 18-7
18-12 Operating Environment ................................................................ 18-7
18-13 Supplied Accessories .................................................................... 18-8
19
Specifications of Optional Accessories ................................................ 19-1
19-1 Battery Pack (BP-L60/L60A/L90/L90A) ..................................... 19-1
19-2 Battery Charger ............................................................................. 19-1
19-3 Remote Control Unit (SRM-10) ................................................... 19-1
19-4 Channel Expansion Unit (SCX-16W) .......................................... 19-2
19-5 Other Options ................................................................................ 19-4
20
Block Diagram ....................................................................................... 20-1
Index
–2–
1 Overview
1-1 Introduction
In the recent years, needs for recording and analyzing ultra wide-band measurement data
such as acoustic data higher than the audible frequency are increasing rapidly in various
fields. However, data recorders with ultra-wide band frequency characteristics, portability,
vibration-resistance, and compatibility for a wide variety of power supplies have not been
readily available on the market.
The SIR-1000W is a small and lightweight 4 ch × 160 kHz × 16 bit ultra-wide band high
speed digital data recorder (refer to below as recorder) which answers to these requirements.
Applying the new AIT technology developed by Sony, the SIR-1000W can record 4 ch
× 160 kHz measurement data on one cartridge in digital format for 2 hours continuously.
By connecting the channel expansion unit SCX-16W, measurement data of 16 ch × 40 kHz
can be recorded for 2 hours continuously on one cartridge, thus further expanding uses.
AIT (Advanced Intelligent Tape) Technology:
AIT is a new standard for high speed, large capacity streamers (computer data backup).
Sony’s high-density magnetic recording technology achieves a 25 GB (non-compressed)
storage capacity and a 24 Mbps data transfer rate.
The newly developed AME (Advanced Metal Evaporated) tape assures remarkable
output with reliability and durability. In addition, TOC (Table of Contents) information
and file position information is written in the built-in 16 kbit memory MIC (Memory In
Cartridge), allowing data to be searched and accessed rapidly in a short period of time.
1-1
1-2 Major Features
Analog Wideband, Multi-Channel
The standard SIR-1000W configuration is 4 ch × 160 kHz, and when combined with the
SCX-16W channel expansion unit, 16 ch × 40 kHz analog data can be recorded and played
back.
LSB Digital Channel
The recorder has function to perform recording and playback the digital signals of 1ch
(768 kHz) to 4 ch (192 kHz), along with analog signals concurrently.
Handy Subchannels
In addition to the above analog channels and LSB digital channels, the recorder is
equipped with the subchannels listed below to allow various types of subdata to be
recorded or played back together with the analog and LSB data.
Channel
Application
Input/Output connector
Voice channel
Voice annotation
Front panel
AUX analog channel
IRIG-B time codes, etc.
Rear panel
AUX digital channel
Binary data such as tacho pulse
Rear panel
Bit Stream Data Recording/Playback
A dedicated bit stream board can be inserted into the recorder’s rear option slot, allowing
up to 8 channels of bit stream data to be recorded and played back separately from and
faster than the standard AUX digital channel. The sampling frequency during simultaneous
recording with analog data is 12 MHz (one channel mode, normal speed), and for digital
data only (analog off), 24 MHz (one channel mode, normal speed). There are two types
of bit stream boards, asynchronous (SBS-10A) and synchronous (SBS-10S).
Large Capacity AIT Cartridge
Up to 25 GB of data can be stored on an AIT cartridge the size of an 8 mm video tape. The
cartridge size is small (95 × 15 × 62 mm) and takes up little storage space.
The newly developed AME tape undergoes Diamond-Like Coating (DLC) processing to
endow it with superior surface durability so that data recording has extremely few dropouts.
High-Quality Recording and Playback
16-bit linear quantization provides a dynamic range of 76 dB or more within a bandwidth
of DC to 40 kHz. The interchannel phase difference is also kept at 2 degrees or less. The
analog input level allows up to ±133 % of the input range values, and the input DC offset
can also be adjusted automatically or manually for each channel within a range of ±100%.
1-2
Time Axis Conversion
The recording/playback speed can be selected from 5 steps. This means that sound data
with ultrasonic bands up to 160 kHz which have been recorded at the normal speed can
be heard by playing back at the 1/16 speed to lower the frequency to audible frequencies
up to 10 kHz. Moreover, large amounts of data recorded at the 1/16 speed for up to 32 hours
can also be played back and transferred to the host computer within 2 hours at the normal
speed.
Error Free Recording
SIR-1000W has rotary heads, so data is recorded on the tape sequentially in slanting tracks
as shown below.
The real-time verify-and-rewrite function verifies (plays back and evaluates) each track
as it is recorded. If the data is not played back correctly, it is written again on the next track.
Accordingly, reduces data drop-out during recording to virtually zero, thus dramatically
improving the reliability of recording.
Error track
Error track
Retry track (OK)
Retry track (NG)
Retry track (OK)
Tape advance direction
Real-time verify-and-rewrite function
Synchronized Operation
Quartz-accurate synchronization is possible using two SIR-1000Ws. This makes it possible
to double the number of channels without sacrificing bandwidth or data transfer rate.
Trigger Recording
The SIR-1000W has a built-in large capacity data buffer memory that allows data to be
recorded before and after a trigger. This is handy for recording suddnly occuring
phenomena or data leading up to an event.
1-3
Compatibility with AIT Drive
Tapes recorded by the SIR-1000W can be read out directly by a computer data backup AIT
drive, making data transfer to computers convenient and efficient.
SCSI Interface
• During recording or playback, the high-speed SCSI board (option) allows digital data
to be transferred to a computer in real-time.
• The SDX emulation board (option) permits the SIR-1000 to be used as an SDX drive
using PCscanIII (option).
Diverse Control Functions
The SIR-1000W can be controlled locally (front panel), by a dedicated remote control unit
SRM-10, by external ON/OFF contacts, and from a host computer.
3-way Power Supply System
The SIR-1000W can run on AC 100/120 V (allowable range 90 to 132 V) or AC 220/240 V
(allowable range 198 to 250 V), or on DC 12 V (allowable range 11 to 30 V) supplied
externally. Further, a dedicated lithium ion battery pack can be mounted on the left side
of the recorder for outdoor use. This battery pack is charged while mounted on the
recorder.
If the AC source is cut off, the external DC or battery pack provides uninterrupted backup.
If the external DC source is cut off, the battery pack provides uninterrupted backup.
The order of priority for the power supply is 1 AC, 2 external DC, and 3 battery pack.
Easy Operation
Measurement instruments in the field must be easy to use and must provide an easy to read
display. The SIR-1000W has a man-machine interface designed from the user’s standpoint:
• Central display screen featuring a backlit, high-contrast LCD panel.
• Direct access to all functions by dedicated keys.
Compact and Light Mass
Dimensions of 340 (W) × 115 (H) × 260 (D) mm (SIR-1000W only, without projections),
and a mass of approximately 7.7 kg (SIR-1000W only) make the SIR-1000W the most
compact and portable recorder in its class.
Low Power Consumption
The SIR-1000W has a low power consumption design, with 1.6 A at AC 100 V, and 7 A
at DC 12 V (SIR-1000W only).
1-4
2 Tape Format and Basic Operations
2-1 Tape Format
Tapes recorded by the SIR-1000W are based on the AIT standard physical and logical
format (ECMA-246). However, at the application level these tapes are of the SIR
dedicated format. This is outlined below:
Start of
recording
Start ID
ID001
BOT BOD
ID002
Start ID
ID003
ID004
Tape
ID999
Incremented
by the ID key
T
O
C
EOD
Blank
EOT
Example of data recorded on a tape by the SIR-1000W.
BOT (Beginning Of Tape) : First position where recording is physically possible.
BOD (Beginning Of Data) : User data is recorded from here.
EOD (End Of Data)
: Each time recording stops, an EOD is written. When
recording is added, the previous EOD is overwritten and
deleted, and a new EOD is written at the location where
the latest recording ended. Reading cannot be performed
after the EOD, even if previously recorded data remains.
Note that when the tape reaches the EOD, the recorder is
automatically set to the STOP mode, “EOD” appears in
the LCD screen and at the same time the EOD LED lights.
The tape cannot be transported further in the forward
direction from this point.
EOT (End Of Tape)
: Last position where recording is physically possible.
ID
: An ID number is attached to each recording. The ID
number 001 is automatically assigned as the first ID, and
the ID number increments each time the ID key is pressed
during recording. The ID number is also incremented
automatically each following recording starts (including
release of the REC-PAUSE mode), or manually each
pressing down of the ID keys while recording. The
maximum ID number is 999. The ID number can be used
for ID search.
Start ID
: This indicates the point where recording starts. The start
ID is not actually written on the tape, but the position is
registered in the TOC. The start ID can be used for start
ID search.
TOC (Table Of Contents) : The position and other information for all ID blocks are
recorded in the form of a table in this area.
2-1
2-2 TOC
The position and ID number of each recording block are registered in the TOC and
recorded on the tape immediately before the EOD. This allows searching to be performed
by specifying an ID number. In addition, the TOC must also be read before appended
recording after the EOD or when overwriting a pre-recorded tape. Note that when using
cartridges with MIC (described hereafter), and when the tape is loaded, TOC data on the
tape has been read and registered in the flash memory (data is not lost even if the power
is turned off) inside the recorder. These recorders are called “TOC-registered recorders”.
When a cartridge with MIC is loaded to a TOC-registered recorder, the TOC data can be
used immediately without having to read the TOC on the tape. Conversely, the TOC data
cannot be used immediately when the TOC on the tape has not yet been read for a cartridge
without MIC, or when the number of ID blocks on a cartridge with MIC exceed 100 and
the TOC has not yet been registered in the recorder.
2-3 MIC (Memory In Cartridge)
A portion of the TOC (up to ID 100) can be copied into a flash memory mounted inside the
cartridge. Therefore, the TOC of cartridges recorded with ID blocks up to 100 can be used
immediately. In addition, even if the recorded ID blocks exceed 100, the TOC data can be used
immediately when loaded to a “MIC-registered recorder”.
2-4 Formatting
• When a different formatted tape or unformatted is loaded, “FMT?” appears in the LCD
screen. At the same time the REC key and FWD key LEDs blink. If you want to format
of this tape, hold down the REC key and press the FWD key. “FMT” appears in the LCD
screen while the tape is being formatted. Formatting requires approximately 80 seconds.
When a blank tape is loaded, “TOC?” appears in the LCD screen and the FF LED blinks.
“FMT?” will appear after pressing the FF key.
Follow the above procedures to format the tape.
• The initial ID number of a tape can be set as desired when formatting the tape. (The
default is 001.) If the ID key is pressed while “FMT?” appears in the LCD screen, the
ID number in the ID display area of the LCD screen blinks. Set the desired ID number
using the ;, :, 8 and 9 keys, then hold down the REC key and press the FWD key.
When recording is performed using this tape, recording starts from the assigned ID
number and increments with each recording.
• The initial ID number can be set as desired (other than 000) during formatting . (default
= 001)
1) Hold down the REC key and press the REW key in the STOP mode.
2) “FMT?” appears in the LCD screen and at the same time the REC key and FWD key
LEDs blink.
3) Hold down the REC key and press the FWD key.
4) The tape is automatically rewound to the BOD and reformatted. “FMT” appears in
the LCD screen during this time.
2-2
2-5 Eject
When an attempt is made to eject a cartridge, the cartridge is automatically rewind to the
BOT and then ejected. It is possible to set for cartridges with MIC being ejected from
halfway in the tape.
2-6 Overwriting Data
Overwriting can be performed on pre-recorded tapes. An EOD is written at the point where
the new recording ends, so old data remaining after that point cannot be played back, so
care should be taken when overwriting on pre-recorded tapes. The figure below shows an
example of a tape which has been overwritten from part-way through ID number 003.
Start ID
Start ID
ID001
ID002
ID003
Tape
ID004
ID100
BOT BOD
T
O
C
Blank
EOT
EOD
Status before overwriting (example)
New recording start
ID001
ID002
ID003
ID004
Not played back
T
O
C
Tape
Blank
Recording stop EOD
BOT BOD
EOT
Status after overwriting on the data in ID003 (example)
New recording start
Not played back
T
ID001 O
C
BOT BOD
Tape
Blank
EOT
EOD
Status after overwriting from the BOD (example)
2-7 ID Block
Each ID block consists of one or more recording units, the recording unit consists of an
approximately 550 kbyte segment referred to as a Record. Therefore, the shortest ID block
length is one Record. This is approximately 170 msec. at the normal speed (× 1) and
approximately 2.7 sec. at 1/16 speed.
2-3
3 Names and Functions of Parts
3-1 Front Panel
Power/Drive block
Display screen
Data mode setting keys
Display keys
POWER
BATT
SPD/BCM
dB
Advanced
Intelligent
Tape
%
OVR 1 1/2 1/4 1/8 1/16 1 2
SPD
AUX
MONI
SPEED
V X1/
S- TIME
ADDRESS REMAIN T - T I M E
Y
M
D
H
M
S
0
FWD
STOP
REC
OVR
PAUSE
CH
RANGE
OFFSET
A
M
A
SEARCH
OUT/TSG
(UNIT)
ID/UTL
MRK/SLF
SHIFT
CH
-40 -100
FF EOD
RANGE
+2
+100
0
LOADING
REW
(CH)
CAUTION
M
-20
BOD
ID
OVR
–6
EJECT
EXT TC
EXP SYN
1-4 5-8
S I R -1000W
PNL LOK
9-12 13-16
PK-CLR
DATA
ALL CH SELECT
LOAD
CLOCK
VOL
PHONE
MIC
ANN/P-SV
INSTRUMENTATION DIGITAL DATA RECORDER
ANALOG
INPUT
≤ ± 100vpk
1
2
3
100k
4
5
6
7
8
LSB DIGITAL
INPUT
≤ ± 10vpk 10k
D1
D2
D3
D4
ANALOG
MONITOR
REF
Tape transport operation keys
Analog INPUT connectors
LSB digital INPUT connectors
3-1
Power/Drive Block
2
1
POWER
BATT
Advanced
Intelligent
Tape
3, 4
5
LOADING
EJECT
BOD
REW
FF EOD
FWD
STOP
REC
PAUSE
6
1 POWER LED
Lights when power is supplied to the recorder.
When power is not supplied to the recorder, all LEDs and the LCD panel turn off.
2 BATT LED
Lights when the battery mounted on the left side of the recorder is supplying power.
Blinks while the battery is being charged, and turns off when charging is completed.
When the BATT LED blinks rapidly, there is a malfunction in charging of battery.
Remove the battery and mount it again. If the BATT LED blinks rapidly again, replace
the battery with a new one.
3 Cartridge cover
Protects the tape transport system from dust.
To open, pull the lid outwards with your finger using the notch at the upper right.
To close, press in the top with your finger.
!
CAUTION
• When using, be sure to close the cover.
• Do not push the transparent window.
Note
To prevent damaging the cartridge cover, the cover comes off if it is pressed down on
strongly when open. To replace the cover, insert one hinge pin and then the other into
their respective bearings.
4 Cartridge compartment
Location for inserting AIT cartridge.
Once the cartridge is inserted part-way, it is loaded automatically.
! CAUTION
• The film of the cartridge insertion slot prevents dust from entering into the tape
transport portion, therefore be sure not to peel it off.
• Do not press in the cartridge too hard, as this may cause malfunctions.
3-2
5 LOADING LED
Lights when the tape has been reeled out of the loaded cartridge and is ready for
recording or playback.
Blinks while the cartridge is loading or unloading.
Turns off when the cartridge compartment is empty.
If LOADING LED is not blinking during loading, once eject the cartridge, then load it
again.
Note
Loading and unloading a cartridge without MIC may take a longer than an MIC cartridge.
6 EJECT button
Press this button to eject the cartridge from the recorder.
EMERGENCY EJECT
When a cartridge cannot be ejected even after several minutes when pressing the
EJECT button, follow the procedures below to eject it.
1) Set OFF the STAND BY switch.
Consequently, the LCD display disappears.
2) Set ON the STAND BY switch.
“LOAD” and “WAIT” are displayed on the LCD screen alternatively.
3) During display of this message, press the EJECT button more than twice.
The LCD display turns to “UNLD/WAIT” and the cartridge is ejected.
Note:
If ejecting a cartridge by this way, the cartridge may get damaged.
Furthermore, failing ejection even by this operation, contact your local Sony Office or
Service Center.
3-3
Tape Transport Operation Keys
The LEDs above the keys light to indicate the active mode.
POWER
BATT
Advanced
Intelligent
Tape
!™
LOADING
EJECT
!¢
BOD
REW
FF EOD
≤ ± 100vpk
!£
!¡
0
INPUT
1
2
FWD
STOP
REC
PAUSE
100k
3
4
5
6
7
8
7
8
9
9
Switching tape transport modes
The tape transport mode that is invoked next by pressing any of the tape transport keys
depends on the current tape transport mode, as shown in the table below:
Key pressed next
REC+
PAUSE
REC+
FWD
PAUSE
FWD
FF/REW
E-E
E-E
E-E
—
—
—
—
—
—
—
—
—
E-E
REC-PAUSE
REC
FWD-PAUSE FWD
—
REC-PAUSE
REC
REC-PAUSE
—
—
EJECT STOP REC
No cartridge
STOP
E-E
STOP
Current mode
E-E
Cartridge loaded
—
—
STOP STOP
EJECT
—
EJECT STOP
FF/REW
REC-PAUSE
—
STOP
—
—
REC
REC
—
—
REC
—
STOP
—
REC-PAUSE
—
REC-PAUSE
—
—
FWD-PAUSE
—
STOP
—
—
—
FWD
FWD
—
FWD
—
STOP
—
—
—
FWD-PAUSE
—
ID SEARCH
FF
—
STOP
—
—
—
—
—
—
REW
—
STOP
—
—
—
—
—
—
SEARCH
—
STOP
—
—
—
—
—
START ID SEARCH
SLF
—
STOP
—
—
—
—
—
—
“—” indicates that the mode remains the same after the key is pressed.
Note
The STOP key’s LED is blinking during transport mode transition such as REC mode to
STOP mode. During above mode transition, other key operation cannot be accepted. Also,
the power may not turn to off instantly by setting the STAND BY switch to off.
3-4
7 PAUSE key
Press this key to select the PAUSE mode.
There are two types of PAUSE mode, REC-PAUSE (recording-pause) mode and
FWD-PAUSE (playback-pause) mode.
In the REC-PAUSE mode, the input data is recorded at the instance of releasing the
pause operation.
In the FWD-PAUSE mode, the beginning of playback data is stored in FIFO memory,
so that the playback signal can be output at the same time as the pause operation is
released.
Note
When the ADDRESS counts are less than 2 seconds during the REC mode, the RECPAUSE mode may be not set up.
8 REC key
• Press this key alone to select the E-E mode.
In the E-E mode, the input signal is output from the recording system directly to the
playback system. This allows users to check the input signal level and set the input
range and input DC offset without transporting the tape.
• Press this key together with the FWD key to select the REC (recording) mode.
In the REC mode, the input signals are recorded onto the tape.
9 STOP key
Press this key to select the STOP mode.
In the STOP mode, all modes are stopped.
Note
• Recorded data is first stored in the FIFO memory of the recorder and then recorded
on the tape. Therefore, the tape may not stop until as much as 20 seconds after the
STOP key is pressed.
• The STOP key LED blinks from the time the STOP key is pressed until the tape
actually stops.
• Press the STOP key in FF or REW mode to stop the tape immediately.
0 FWD key
Press this key to select the FWD (playback) mode.
In the FWD mode, the data on the tape is played back.
!¡ FF key
Press this key to select the FF (fast-forward) mode.
In the FF mode, the tape is fed in the EOD direction at approximately 75 times the
normal speed.
When this key is pressed in the search mode, the next start ID is searched. When pressed
in the FWD mode, the tape skips to the start of the next ID number.
3-5
!™ EOD LED
Lights when the tape is at the EOD (End of Data) position.
EOD signifies the end of the data recorded on the tape.
Note
• When recording is stopped, the TOC and EOD are written at that address and the
EOD LED lights.
• When starting to record from the EOD, make sure that the EOD LED is extinguished
after recording starts (within approximately 5 seconds at normal speed).
• In the FWD and FF modes, tape transport stops automatically when it reaches the
EOD.
!£ REW key
Press this key to select the REW (rewind) mode.
In the REW mode, the tape is fed in the BOD direction at approximately 75 times the
normal speed.
When this key is pressed in the search mode, the start ID of the current recording block
is searched.
When pressed in the FWD mode, the tape skips to the start of the current ID number.
!¢ BOD LED
Lights when the tape is at the BOD position.
BOD signifies the beginning of the data recorded on the tape.
Note
In the REW mode, tape transport stops automatically when it reaches the BOD.
3-6
Data Mode Setting Keys
!•
@£
SPD/BCM
!§
!¶
@¡
@™
@¢
(CH)
RANGE
M
OFFSET
A
M
@∞
A
SEARCH
OUT/TSG
(UNIT)
ID/UTL
MRK/SLF
SHIFT
@§
!∞
PNL LOK
!ª
DATA
VOL
PHONE
@º
MIC
ANN/P-SV
@¶
@ª14
@•
15
16
#º
MONITOR
Switching setting modes
Valid mode setting keys for the current mode are shown in the table below:
Current mode
Mode Setting Key
SPD/BCM
RANGE, OFFSET
OUT
STOP
Yes
Yes
Yes
No
ID
UTL
MRK
SLF
Yes
No
Yes
No
Yes
TSG SEARCH
E-E
Yes
Yes
Yes
Yes
No
No
No
No
No
REC-PAUSE
Yes
Yes
Yes
Yes
No
No
No
No
No
REC
No
Yes
Yes
Yes
No
Yes
(ID increment)
No
Yes
(Mark setting)
No
FWD
No
No
Yes
No
No
No
No
Yes
(Mark setting)
No
FF
No
No
No
No
No
No
No
No
No
REW
No
No
No
No
No
No
No
No
No
SEARCH
No
No
No
No
—
Yes
(ID setting)
No
Yes
(Start mark search)
No
SLF
No
No
No
No
No
No
No
No
—
“—” indicates that the mode remains the same after the key is pressed.
3-7
!∞ SHIFT key
• Press this key to select the SHIFT mode. The LED to the upper left of this key lights.
At the same time, the LEDs to the upper right of the following keys blink, and the
functions indicated on the right side can be selected.
SPD/BCM key
OUT/TSG key
MRK/SLF key
ID/UTL key
RANGE key
OFFSET key
ANN/P-SV key
Example 1:
Press only the SPD/BCM key to select the SPD mode. To select the BCM mode, press
the SHIFT key and then the SPD/BCM key.
Example 2:
Press only the RANGE key to select the M-RANGE (manual range setting) mode. To
select the A-RANGE (automatic range setting) mode, press the SHIFT key and then the
RANGE key.
• Hold the SHIFT key down for at least 2 seconds to select the PNL LOK (panel lock)
mode. The PNL LOK LED lights, and all the keys on the front panel are disabled.
To cancel the PNL LOK mode, hold the SHIFT key down again for at least 2 seconds.
!§ SPD/BCM key
• Press only this key to select the SPD (tape speed setting) mode. The LED to the upper
left of the key blinks. At the same time, the selected SPD LED (1, 1/2, 1/4, 1/8, 1/
16) lights.
Select the tape speed using the ; or : key.
To end the SPD mode, press the SPD/BCM key again.
• When this key is pressed once after pressing the SHIFT key, the recorder enters into
the BCM (analog channel mode setting) mode, and the LED to the upper right of the
key blinks.
Select the analog channel mode using the ; or : key.
When this key is pressed twice within one second after pressing the SHIFT key, the
recorder enters into the BCM (digital channel setting) mode, and the LED to the
upper right of the key blinks.
Select the digital channel mode using the ; or : key.
To end the BCM mode, press the SPD/BCM key again.
3-8
!¶ RANGE key
Press this key to select the RANGE (range setting) mode.
In the RANGE mode, the input range for the recording amplifier can be switched for
each channel.
Range values
±0.5 Vpk, ±1 Vpk, ±2 Vpk, ±5 Vpk, ±10 Vpk, ±20 Vpk
There are two types of RANGE mode, M-RANGE (manual range setting) mode and
A-RANGE (automatic range setting) mode.
• Press only this key to select the M-RANGE (manual range setting) mode. The “M”
LED to the upper left of the key blinks. At the same time, the range values for the
channels to be set blink on the LCD screen.
Select the range values using the 8 or 9 key.
Switch the channel to be set using the ; or : key.
Note
To set the optimum input range for input signals that include unnecessary DC
components, it is advisable to set the input DC offset in advance.
• When the RANGE key is pressed after pressing the SHIFT key, the A-RANGE
(automatic range setting) mode results and the “A” LED to the upper right of the key
blinks.
In the A-RANGE mode, the range for each channel is set automatically according
to the level of the input signal. Press this key again to enter the range settings for each
channel according to these measurements.
!• OFFSET key
Press this key to select the OFFSET (offset setting) mode. In the OFFSET mode,
unnecessary DC components included in the input signal are eliminated, thus improving
resolution of the dynamic signal. The offset values can be set for each channel.
Offset value
±100%, in 1% increments/decrements
There are two types of OFFSET mode, M-OFFSET (manual offset setting) mode and
A-OFFSET (automatic offset setting) mode.
• Press only this key to select the M-OFFSET (manual offset setting) mode. The “M” LED
to the upper left of the key blinks. At the same time, the offset values (top four digits in
the tape position display area) for the channels to be set blink on the LCD screen.
Select the offset values using the 8 or 9 key.
Switch the channel to be set using the ; or : key.
• When the OFFSET key is pressed after pressing the SHIFT key, the A-OFFSET
(automatic offset setting) mode results and the “A” LED to the upper right of the key
blinks.
In the A-OFFSET mode, the DC components of the input signal are calculated and
canceled by automatically adding the required DC offset to the input signal. Press
this key again to calculate the DC components from the peak values detected so far,
enter the DC offset setting, and exit the A-OFFSET mode.
3-9
!ª OUT/TSG key
• Press only this key to select the OUT (output level setting) mode. The LED to the
upper left of the key blinks. At the same time, the output values for the channels to
be set blink on the LCD screen.
In the OUT mode, the output level of the playback amplifier can be switched for each
channel.
Output level value
±1 Vpk, ±2 Vpk, ±5 Vpk, manual (continuous variable)
Select the output level values using the 8 or 9 key. To adjust the output level
manually, use the output level adjustment potentiometers on the rear panel.
Switch the channel to be set using the ; or : key.
Note
When set to the manual position, “– –” appears in the RANGE display area on the
LCD screen.
• When the OUT/TSG key is pressed after pressing the SHIFT key, the TSG (test
signal) mode results and the LED to the upper right of the key blinks. At the same
time, the types of test signal output for all channels appear on the LCD screen.
Test signal
AC ±100%, DC +100%, DC –100%, 0 V, EXT
Select the test signal using the ; or : key.
For EXT (external), the signal input to CH 1 becomes the test signal for CH 1 to CH
8. The input signal to CH 9 of the channel expansion unit becomes the test signal for
CH 9 to CH 16. The “EXT” is displayed on the LCD screen.
@º MRK/SLF key
• Press this key in REC or FWD mode to select the MRK (mark setting) mode. The
LED to the upper left of the key lights momentarily.
The position of the tape when this button was pressed is stored in the memory, and
is saved until this key is pressed again while the cartridge is loaded.
• When the MRK/SLF key is pressed after pressing the SHIFT key, the SLF (selfcheck) mode results and the LED to the upper right of the key blinks.
In the SLF mode, the recorder automatically executes the specified test program to
check for trouble.
Self-check items Recording/playback heads, amplifier • tape path system
• When the MRK/SLY key is pressed twice within one second after pressing the
SHIFT key, the recorder enters into the CAL (calibration) mode, and the CAL is
displayed on the LCD screen at the same time.
CAL items DC offset, gain error correction
@¡ SEARCH key
Press this key to select the SEARCH mode. The LED to the upper left of the key blinks.
At the same time, the LEDs of the ID/UTL, MRK/SLF, FF, and REW keys blink. Press
one of these keys to select the desired search mode as follows.
1) ID/UTL key : ID SEARCH
2) MRK/SLF key : MARK SEARCH
3) FF key
: FORWARD START ID SEARCH
4) REW key
: REVERSE START ID SEARCH
During search in any of these search modes, the SEARCH LED blinks, and turns off
when the target has been found. It continues to blink if the search target is not found.
When the search target is found, the tape stops at the target position.
3-10
@™ ID/UTL key
• Press this key to increment the value of the ID number by 1 in the REC mode. The
ID number can be changed depending on the contents of the recording.
• When this key is pressed in the SCH mode, the ID SEARCH mode is invoked and
the set ID number is used as the search target.
The value of the ID number can be incremented or decremented using the 8 or 9 key.
To move to a different digit of the ID number, use the ; or : key.
• When this key is pressed after pressing the SHIFT key, the recorder enters into the
UTL (utility setting) mode, and the AT FMT is displayed on the LCD screen. Select
the utility function using the 8 or 9 key.
Function and display
on LCD screen
AT
FMT
ERA
Contents
ON :
When an unformatted tape is acknowledged, it will
automatically be formatted.
OFF : FMT? will be displayed and the tape will not be
automatically formatted.
ON :
SYNC
ID01
Use to set the SYNC ID, and it is displayed when the
unit is set as slave in the synchronized operation.
DEW
ON :
Detects whether there is condensation.
(Standby time: 3 minutes)
OFF : No detection of whether there is condensation.
(No standby time)
ON :
OFF
Recorded tapes can be overwritten.
OFF : ERA OFF will be displayed and the tape cannot
be overwritten.
BOT
EJCT
Factory
setting
Disables ejection halfway in a tape.
A tape is ejected after being rewind to BOT.
When loading again, the tape stops at the point
where the tape was ejected.
ON
01
OFF
ON
OFF : Enables ejection halfway in a tape. (It is effective
for a cartridge with MIC.)
SKP
ET03
ON :
When ET03 error arises, skips the error portion
automatically and restarts playback. Meanwhile
the signal is not output for 30 seconds.
OFF
OFF : Stops playback when ET03 error arises. After
pressing the STOP key, eject the tape.
CMP
MODE
ON :
Compression mode is valid.
OFF : Compression mode is invalid. (Non-compression
mode)
ON
After selecting the utility function, select ON/OFF the function and SYNC ID using
the ; or : key.
When selected (it will be turned ON), the √ mark will be displayed at the head of
characters. When the ID/UTL key is pressed, the recorder enables the selected utility
function.
3-11
Note
• If the STOP key is pressed during setting, the setting to be set will be canceled.
• Supplement about the function.
ERA
Once overwriting starts with the ERA function is off, the ERA OFF is displayed on
the LCD screen, and the recorder cannot be entered into the REC mode.
DEW
When STAND BY switch is turned on with the DEW function ON, a standby time
of 3 minutes will be required for condensation detection. The time to completion will
be displayed on the LCD.
BOT EJECT
The BOT EJECT function is valid only for the cassette with MIC. When using a same
tape frequently, it is advisable to set this function ON. With this function set OFF,
a repeat of loading /ejecting a tape at the same point may cause damage (play back
disability) for the data on the portion.
The cassettes without MIC are all ejected after being rewind to BOT.
SKP ET03
When SKP ET03 function setting is ON, the synchronous operation does not
synchronize at the point of skip.
When ET03 error arises and playback is stopped during the function setting is OFF,
EJECT key only activates.
CMP MODE
The data compression by setting ON the CMP MODE enables the data transmission
between the tape and memory to make fast, which results in a large allowance against
mark will rarely appear.
overflow or underflow of the memory, therefore
(As the data possible to be compressed uses smaller amount of a tape, if the number
of retry is a few, the recoding time will be extended. As for the retry, refer to Section
4-5 Warning Display “ Record/Play Back Error”.)
At CMP MODE set ON (compression mode), pressing the REC key displays “CMP”
on the LCD screen about a half second.
In addition, the tape recorded in CMP MODE ON state can be played back even by
the recorder having no setting of CMP MODE.
! CAUTION
• When the DEW function is OFF, as no condensation detection is performed, the
tape may become damaged.
• When using in an environment below 5 °C, be sure to turn ON the DEW function.
• The CMP MODE can be switched to ON or OFF only when a tape is loaded.
• When using SBS-10A/S (asynchronous type bit stream board) or SVB-10 (MPEG
video board), the CMP MODE is automatically set OFF (non-compression mode).
• The REMAIN value at CMP MODE can be the reference. (Because the compression
rate differs in accordance with the data.)
3-12
@£ ; key
• Press this key to shift the blinking channel or numerical digit on the LCD screen one
position to the left. When the blinking position reaches the left edge, pressing this key
once more causes it to jump to the right edge.
• Use this key when shifting the monitor channel in the direction of the smaller
numbers, and when raising the tape speed.
@¢ : key
• Press this key to shift the blinking channel or numerical digit on the LCD screen one
position to the right. When the blinking position reaches the right edge, pressing this
key once more causes it to jump to the left edge.
• Use this key when shifting the monitor channel in the direction of the larger numbers,
and when lowering the tape speed.
@∞ 8 key
• Press this key to increase the blinking channel or numerical digit on the LCD screen
by one step.
• Use this key when selecting the channel mode.
• To select the recorder or channel expantion units to be monitored on the LCD screen,
press the 8 or 9 key.
Note
Press the ALL CH key to set all channels to the same value.
@§ 9 key
Press only this key to decrease the blinking channel or numerical digit on the LCD
screen by one step.
Use this key when selecting the channel mode.
Note
• When the 8 or 9 keys are both held down for at least 2 seconds, the setting values
are set to the values listed below.
Be sure to set the values in the STOP mode.
At this time, the DATA or ANN/P-SV key is set to ANN/P-SV.
1) CHANNEL mode
2)
3)
4)
5)
6)
7)
: Maximum usable value from among
2 ch, 4 ch, 8 ch, and 16 ch
Tape speed
: 1 (normal speed)
Input range
: ±1 Vpk
Input DC offset
: 0%
Output level
: ±1 Vpk
Monitor channel
: CH 1
LSB digital channel : OFF
• Press the ALL CH Key to set all channels to the same value.
3-13
@¶ ANN/P-SV key
• Each time this key is pressed, the playback signal source for the speakers or earphone
jack switches between the recorded voice annotations and the analog data signal.
While the ANN LED lights, the voice annotation recorded into the voice channel is
output from the speakers or earphone jack.
While the DATA LED lights, the data signal of the monitored analog channel is
output as sound from the speakers or earphone jack.
• When the ANN/P-SV key is pressed after pressing the SHIFT key, the P-SV (powersave) mode results and the LED to the upper right of the key lights.
During recording, the analog playback circuitry and LCD panel backlight turn off to
save power consumption.
• When this key is pressed for more than three seconds after pressing the SHIFT key,
the recorder enters into the fan-control mode. This mode allows the ventilation fans
to be stopped during the REC mode as long as the internal temperatures of the SIR1000W and SCX-16W are low, making it convenient for recording sound level and
other applications where silence is required. In the fan-control mode, the LED to the
upper right of the ANN/P-SV key blinks and rectangular mark appears at the right
edge of the tape position display area on the LCD screen.
To exit the fan-control mode, press the SHIFT key and then press this key for three
seconds or more. Refer to 4-7 for more detail about the fan-control mode.
! CAUTION
When SIR-1000W exits the power save (or fan-control) mode, noise (less than 1 ms)
may occur in the SIR-1000W, and it may be recorded on the tape.
It is possible to avoid above trouble by switching (on/off) the power save mode in
STOP mode. And it is possible to avoid above trouble by stopping the recording
before SIR-1000W exits the fan-control mode automatically.
@• MIC (Microphone) jack
Insert the supplied microphone plug here. The MIC LED lights according to the sound
input.
@ª VOL knob
Rotate to adjust the playback volume for the speakers or earphones.
Note
The playback volume of the warning buzzer is also adjusted.
#º PHONE jack
Insert the plug of any separately purchased earphones using a mini plug here.
3-14
LCD Screen
#¢
#∞
#•
#£
#™
#¡
dB
%
OVR 1 1/2 1/4 1/8 1/16 1 2
SPD
AUX
EXT TC
EXP SYN
ID
#ª
OVR
+2
+100
0
#¶
–6
MONI
SPEED
V X1/
S- TIME
ADDRESS REMAIN T - T I M E
Y
M
D
H
M
S
0
RANGE
CH
-20
-40 -100
OVR
CH
#§
CAUTION
1-4 5-8
S I R -1000W
$™
$£
9-12 13-16
PK-CLR
ALL CH SELECT
LOAD
CLOCK
$¡
$º
#¡ OVR LED
Lights when over-ranging occurred in any channel in the E-E, REC-PAUSE, REC or
FWD mode.
#™ SPD LEDs
These LEDs indicate the tape speed set for the recorder. The LED of the selected speed
(1, 1/2, 1/4, 1/8, or 1/16) lights.
#£ AUX LEDs (1, 2)
• When a signal (TTL level) is input to the AUX-1 (DIGITAL) IN connector, or when
the recorded signal is played back, the “1” LED lights.
• When a signal (more than ±0.2 Vpk) is input to the AUX-2 (IRIG-B) IN connector,
the “2” LED lights.
#¢ EXP LED
Lights when a channel expansion unit is connected and enabled according to the
channel mode (16-channel mode).
#∞ SYN LED
When multiple recorders are operating in synchronizing mode, the SYN LED lights or
blinks according to the states of the recorders.
#§ EXT TC LED
Lights when the IRIG-B time code signal input from an external time code generator
is successfully detected, or during playback of the IRIG-B time code signal recorded
on the tape.
3-15
#¶ Bar meter area
The bar meter indicates the analog data signal level for each channel. The display can
be switched to either a percentage scale or dB scale, depending on the purpose.
• The percentage scale or the dB scale can be selected by using the digital switch on
the rear panel.
• The percentage scale uses a bidirectional format. With 0% as center, the signal level
moves up (+) or down (–) according to the signal polarity. The percentage scale is
suitable for measuring stress, distortion, acceleration and other data signals that
include DC components.
• The dB scale uses a unidirectional format. Regardless of the signal polarity, the data
signal value is displayed as a dB value (+2 dB, –6 dB, –20 dB, etc.) relative to the
reference level (0 dB). The dB scale is suitable for measuring acoustic and other data
signals that do not include DC components.
• When the level for any channel is over-range, the OVR LED and corresponding OVR
mark light. When the percentage scale is selected, the OVR marks on the positive (+)
side, negative (–) side or both sides light according to the polarity of the signal.
• The bar meter response characteristics can be switched between real time and peak
hold using the digital switch on the rear panel.
• Message by alphabetical characters are also displayed here.
Messages
Message
3-16
Status
CBUF 70 to 100
Buffer use area exceeds 70% during recording.
(Increasing the number of rewriting due to dust.)
CHNG TAPE
Change of tape request.
CMP
Compression mode.
DATA CLAR
Writing the data inside the buffer to a tape is in progress.
DRIV BUSY
Waiting time until starting the drive after the REW key had been pressed.
EOD WRT
Writing the TOC and EOD is in progress.
EOD WRT, WAIT
Writing the TOC is in progress after returning from power OFF during recording.
EOT
Tape stops at EOT.
ERA?
Overwriging?
* If yes, press REC-FWD key and if no, press STOP key.
FMT
Formatting is in progress.
FMT?
Formatting?
* If yes, press REC-FWD key and if no, press STOP key.
HEAD CLEN
Head cleaning request with a cleaning cassette.
HI T WAIT
Stands by until the internal temperature drops below 50 °C.
LOAD OK?
Setting the recorder’s data conformed to the data on tape?
* If yes, press LOAD key and if no, press STOP key.
LOAD WAIT
Tape loading is in progress.
LO T WAIT
Stands by until the internal temperature rises above 5 °C.
RWD WAIT
Cartridge is rewinding by BOD.
SLF
Self check is in progress.
SLF EOT
As the data is recorded as far as the EOT, self check is impossible.
SLF NG
Self check was NG.
* In this case, change a tape or perform a head cleaning.
SONY V**
Displays the recorder version.
SRCH BOD
BOD search is in progress.
STB 10
STB-10 mode (for use in streamer drive).
STB 30
STB-30 mode (for use in high speed data transmission).
TOC READ
Reading the TOC is in progress.
TOC?
Reading the TOC?
* If yes, press FF key and if no, press STOP key.
UNLD WAIT
Unloading is in progress.
WARM WAIT
Condensation has been detected and currently warming up.
600S — 000S
Time to condensation detection or clearing of condensation (seconds).
#• ID display area
This area displays the ID number (source data/tape data).
Correspondence between the transport mode and the source data/tape data is shown in
the table below:
Transport Mode
E-E, REC-PAUSE, REC,
and succeeding STOP
FWD and succeeding STOP
Display
Source data
(value set in recorder)
Tape data
(value recorded on tape)
#ª CAUTION display area
This area displays warnings concerning low DC voltage and recording and playback
errors.
$º MONI display area
This area displays the channel number of the monitored channel.
$¡ RANGE display area
• This area displays the input range value (source data or tape data) for the monitored
channel.
Correspondence between the transport mode and the source data (value set in
recorder) or tape data (value recorded on tape) is shown in the table below:
Transport Mode
Display
E-E, REC-PAUSE, REC,
and succeeding STOP
Source data
FWD and
succeeding STOP
Tape data
• In the OUT mode, this area displays the output level value for the channel to be set.
At this time the text “RANGE” is not displayed.
$™ SPEED display area
This area displays the tape speed at the tape was recorded in the FWD mode.
3-17
$£ Tape position display area
• This area displays the following tape position and time information (source data or
tape data).
ADDRESS : Displays the tape position from the (00H00M00S) of each recording
block in hour, minute and second. The ADDRESS is set automatically
to 00H00M00S when recording begins.
Note
The ADDRESS counts in step with real time at normal speed, and
slows down in proportion to the speed at 1/2 speed or slower.
In addition, when operating at 1/2 speed or slower, the lower digit for
indication of seconds blinks at a rate of once per second.
REMAIN : Displays the amount of tape remaining in hour and minute according
to the tape speed.
S-TIME
: Displays the current recorder time (source time) in year/month/day
and in hour/minute/second.
T-TIME
: Displays the time recorded on the tape in year/month/day and in hour/
minute/second.
Correspondence between the transport mode and the source data or tape data is
shown in the table below:
Transport Mode
Display
Remarks
E-E, REC-PAUSE, REC,
and succeeding STOP
Source data
ADDRESS, REMAIN, and
S-TIME valves set in recorder
FWD and
succeeding STOP
Tape data
ADDRESS, REMAIN, and
T-TIME valves recorded on tape
• In the OFFSET mode, this area displays the input DC offset value for the channel to
be set.
3-18
Display Keys
dB
%
OVR 1 1/2 1/4 1/8 1/16 1 2
SPD
AUX
EXT TC
EXP SYN
ID
CAUTION
OVR
+2
+100
0
–6
MONI
SPEED
V X1/
S- TIME
ADDRESS REMAIN T - T I M E
Y
M
D
H
M
S
0
-20
-40 -100
OVR
CH
RANGE
CH
1-4 5-8
S I R -1000W
9-12 13-16
PK-CLR
ALL CH SELECT
LOAD
CLOCK
$¢
$∞
$•
$¶
$§
$¢ PK-CLR key
When the bar meter display mode is peak hold, the peak indicator bar display and the
OVR LED are cleared each time this key is pressed.
$∞ ALL CH key
When this key is pressed in the RANGE, OFFSET or OUT mode, all 16 channels of
the recorder and the channel expansion unit are set to the same valves selected.
$§ SELECT key
Each time this key is pressed, the display for ADDRESS, REMAIN, and S-TIME/TTIME switches as below.
• During the E-E, REC-PAUSE or REC mode
: ADDRESS → REMAIN →S-TIME (Y, M, D) — S-TIME (H, M, S)→ADDRESS
• During the STOP, FWD, FF or REW mode
: ADDRESS→REMAIN→T-TIME (Y, M, D) →T-TIME (H, M, S)→ADDRESS
$¶ LOAD key
When this key is pressed in the STOP or E-E mode, the message “LOAD OK?” blinks
on the LCD screen. When this key is pressed once more, the following recorder settings
are set the same as when the tape played back last time, and the message “LOAD OK?”
disappears.
BCM, SPD, RANGE and OFFSET.
To cancel the LOAD, press the STOP key.
Note
It become effective after playing back the tape.
$• CLOCK key
Press this key to set the time for the reference clock in the recorder.
Regarding the setting method, refer to page 5-6.
3-19
Analog Input Connectors
POWER
BATT
SPD/BCM
dB
Advanced
Intelligent
Tape
%
OVR 1 1/2 1/4 1/8 1/16 1 2
SPD
AUX
–6
FF EOD
FWD
STOP
RANGE
M
MONI
REC
CH
SPEED
OFFSET
A
M
A
SEARCH
OUT/TSG
(UNIT)
ID/UTL
MRK/SLF
SHIFT
CH
OVR
PAUSE
RANGE
V X1/
S- TIME
ADDRESS REMAIN T - T I M E
Y
M
D
H
M
S
0
-40 -100
REW
(CH)
CAUTION
OVR
-20
BOD
ID
+2
+100
0
LOADING
EJECT
EXT TC
EXP SYN
1-4 5-8
S I R -1000W
PNL LOK
9-12 13-16
PK-CLR
DATA
ALL CH SELECT
LOAD
CLOCK
VOL
PHONE
MIC
ANN/P-SV
INSTRUMENTATION DIGITAL DATA RECORDER
ANALOG
INPUT
≤ ± 100vpk
1
2
3
100k
4
5
6
7
LSB DIGITAL
INPUT
8
≤ ± 10vpk 10k
D1
D2
D3
D4
ANALOG
MONITOR
REF
$ª
%¡
%º
$ª ANALOG INPUT connectors
Used to input analog data signals for channels 1 to 8.
! WARNING
• Be sure to input within the specified voltage range (±26.6 Vpk).
• Do not supply input signals exceeding ±100 Vpk, or the internal circuitry may be
damaged.
Note
An effective connector differs in accordance with the channel mode.
Be sure to comply with the indication of each channel.
Channel mode
Effective channel
2
1, 2
4
1 to 4
8
1 to 8
16 (When expanded)
1 to 16
%º Channel Mode LED
The LED set by the channel mode lights.
%¡ ANALOG MONITOR connector
Used to monitor the analog data signal of the selected channel.
3-20
LSB Digital Input Connectors
POWER
BATT
SPD/BCM
dB
Advanced
Intelligent
Tape
%
OVR 1 1/2 1/4 1/8 1/16 1 2
SPD
AUX
–6
FF EOD
FWD
STOP
RANGE
M
MONI
REC
CH
SPEED
OFFSET
A
M
A
SEARCH
OUT/TSG
(UNIT)
ID/UTL
MRK/SLF
SHIFT
CH
OVR
PAUSE
RANGE
V X1/
S- TIME
ADDRESS REMAIN T - T I M E
Y
M
D
H
M
S
0
-40 -100
REW
(CH)
CAUTION
OVR
-20
BOD
ID
+2
+100
0
LOADING
EJECT
EXT TC
EXP SYN
1-4 5-8
PNL LOK
9-12 13-16
S I R -1000W
PK-CLR
DATA
ALL CH SELECT
LOAD
CLOCK
VOL
PHONE
MIC
ANN/P-SV
INSTRUMENTATION DIGITAL DATA RECORDER
ANALOG
INPUT
≤ ± 100vpk
1
2
3
100k
4
5
6
7
8
LSB DIGITAL
INPUT
≤ ± 10vpk 10k
D1
D2
D3
D4
ANALOG
MONITOR
%£
REF
%™
%™ LSB DIGITAL INPUT connectors
Used to input LSB digital data signals to digital channels D1 to D4.
! WARNING
• Be sure to input TTL level signal only.
• Do not input signals exceeding ±10 Vpk, or the internal circuitry may be damaged.
Note
An effective connector differs in accordance with the channel mode.
Be sure to comply with the indication of each channel.
Channel mode
1
Effective channel
1
2
1, 2
4
1 to 4
%£ Channel Mode LED
• The LED lights according to the digital channel mode.
• When the input or output signal level changes L to H and/or H to L, the LED blinks,
while the input or output signal level does not change, the LED lights continuously.
Note
If the input or output signal is no changed, the LED lights.
3-21
3-2 Rear Panel
Power supply block
Control block
8 7 6 5 4 3 2 1
!
9
8
25
6
7
24
21
22
23
19
20
18
17
16
15
14
1
4
3
2
13
12
11
10
9
8
7
6
5
4
3
2
1
REMOTE
5
EXT. CONT
COM
AUX-2 (IRIG-B)
IN
OUT
SYNC
AUX-1 (DIGITAL)
IN
OUT
TRIG/REC
IN
% / dB
MST / SLV
IRIG ON / OFF
APD OFF / ON
(UP / DOWN)
VOLTAGE
AC FUSE
T4A
! SELECTOR
220V
RAL / HLD
9.6 / 19.2
TRG S/M
PTRG OFF/ON
240V
DC IN
STAND BY
AC IN
DC BREAKER
XLR 32F
RS
H
CANNON
OPTION SLOT 2
OPTION SLOT 1
Option slots
D4
D3
D2
D1
LSB DIGITAL
OUTPUT
LSB digital output connectors
3-22
8
7
6
5
4
3
Analog output connectors
2
1
ANALOG
OUTPUT
Power Supply Block
7
4
8 7 6 5 4 3 2 1
% / dB
MST / SLV
IRIG ON / OFF
APD OFF / ON
(UP / DOWN)
!
VOLTAGE
AC FUSE
T4A
! SELECTOR
220V
RAL / HLD
9.6 / 19.2
TRG S/M
PTRG OFF/ON
3
240V
DC IN
STAND BY
AC IN
DC BREAKER
XLR 32F
1
CANNON
2
OPTION SLOT 1
6
5
OUTPUT
8
7
6
5
4
3
2
1
1 STAND BY switch
Used to turn power for the main functions of the recorder on and off.
Note
The battery pack charging function is valid regardless of the STAND BY switch
position, if the AC power is connected.
2 AC IN connector
Used to supply external AC power to the recorder. Connect the supplied AC power cord.
! CAUTION
Be sure to supply voltage within the specified range.
3 AC voltage selector switch
Used to switch the AC voltage between 100/120 V (allowable range 90 to 132 V) and
220/240 V (allowable 198 to 250 V), according to the local AC voltage.
! CAUTION
• Be sure to set the voltage selector switch to the voltage range you intend to use.
• The AC power cord has a safety earth. Be sure to connect the power cord to an earthed
socket.
4 AC fuse
This fuse is used to protect the AC power system.
! CAUTION
For continued protection against risk of fire, replace only with fuse of the specified type
and current ratings.
Be sure to disconnect the AC power cord when replacing the fuse.
5 DC IN connector
Used to supply external DC power to the recorder. Connect the supplied DC power cord.
! CAUTION
Be sure to supply voltage (DC 11 to 30 V) within the specified range.
3-23
6 DC circuit breaker
This circuit breaker is used to protect the DC power system.
When the circuit breaker functions, the lever falls forward. To reset the circuit breaker,
pull of the DC power cord and wait a short time, then press the lever back up with your
finger.
7 Digital switches
The characters on the left side of the slash indicates the status when the switch is in
upper position, and the characters on the right side, when the switch is in lower
position.
(Example) MST/SLV
Lower position
Upper position
Note that the factory setting for all switches is in upper position.
1) RAL/HLD
Used to switch the response characteristic of the bar meter’s peak indicator.
In the HLD (peak hold) mode, the peak indicator is held at the maximum level until
the PK-CLR key is pressed or until the E-E, REC-PAUSE, REC or FWD mode is
invoked.
2) 9.6/19.2
Used to set the RS-232C transfer rate for the COM connector.
9.6 : 9.6 kbps
19.2 : 19.2 kbps
3) TRG S/M
When this switch is set to the S (upper position) with the recorder is in REC-PAUSE
mode, recording starts when the trigger input signal goes from high to low and
continues until the STOP key is pressed. When set to the M (lower position),
recording starts when the trigger input signal goes low, and when the signal goes
high the recorder becomes REC pause.
4) PTRG OFF/ON
Used to switch the pre-trigger recording mode between ON and OFF.
3-24
5) APD OFF/ON
Used to switch the APD (Auto Power-Down) mode between ON and OFF.
The APD mode is used to automatically perform stop processing and turn off the
power supply to the recorder when the higher priority power supply is stopped with
a back-up power source present.
This mode is valid for the power supply connections noted below:
Priority power source
Back-up power source
AC
DC and battery (DC priority)
AC
DC
AC
Battery
DC
Battery
• When APD mode is ON:
During recording : TOC and EOD are written on the tape, recording stops and
then the power is turned OFF.
Other than during recording : The STOP mode is invoked and then the power is
turned OFF.
When power is supplied again, the recorder
automatically performs the following operations.
— When the recorder was stopped during recording: The ID is incremented and
the REC mode is invoked.
— When the recorder was stopped other than during recording: The STOP
mode is invoked.
Note
When APD mode is ON, a microscopic current flows even when the recorder
power is OFF. If the recorder is left for a long time in this condition, the battery
will completely discharge.
• When APD mode is OFF, if the higher priority power supply is stopped, the
recorder enters the battery back-up mode and continues operation as long as
there is a charge remaining in the battery, yet the operation way end abnormally.
6) IRIG ON/OFF
Set this switch to ON to record the IRIG (IRIG-B time code) signal onto the AUX
analog channel. Set to OFF to input analog signals other than IRIG signal.
7) MST/SLV
Used to set the recorder to master or slave for synchronous operation.
8) %/dB
Used to switch the bar meter scale to percentage or dB.
3-25
Control Block
0
9
AC BREAK
8 7 6 5 4 3 2 1
8
25
6
7
24
21
22
23
19
20
18
17
16
15
14
1
4
3
2
13
12
11
10
9
8
7
6
5
4
3
2
1
!™
REMOTE
5
EXT. CONT
!¢
9
8
COM
AUX-2 (IRIG-B)
IN
OUT
AUX-1 (DIGITAL)
IN
OUT
RAL / HLD
9.6 / 19.2
TRG S/M
PTRG OFF/ON
% / dB
MST / SLV
IRIG ON / OFF
APD OFF / ON
(UP / DOWN)
SYNC
TRIG/REC
IN
DC IN
DC BREAK
XLR 32F
S
HR
CANNON
!£
!¡O
OPTION SLOT 2
!∞
16
15
14
13
12
11
10
9
8
7
6
5
8 EXT.CONT connector
Used to control the recorder by means of external make contacts.
9 COM connector
Used to control the recorder from a host computer via the RS-232C interface.
0 SYNC connector
Used when operating multiple recorders synchronously.
!¡ TRIG/REC IN connector
Used to input the trigger for trigger recording.
!™ REMOTE connector
Used to connect a remote control unit (sold separately).
!£ AUX-1 (DIGITAL) IN/OUT
Used to input and output AUX digital channel data. Connect BNC cables (sold
separately) to the corresponding connectors.
!¢ AUX-2 (IRIG-B) IN/OUT
Used to input and output AUX analog channel data. Connect BNC cables (sold
separately) to the corresponding connectors.
!∞ GROUND terminal
This terminal has the same electric potential as the signal line on the ground side and
the frame.
3-26
Option Slots
8 7 6 5 4 3 2 1
!
9
8
25
6
7
24
21
22
23
19
20
18
17
16
15
14
1
4
2
3
13
12
11
10
9
8
7
6
5
4
3
2
1
REMOTE
5
EXT. CONT
COM
AUX-2 (IRIG-B)
IN
OUT
% / dB
MST / SLV
IRIG ON / OFF
APD OFF / ON
(UP / DOWN)
SYNC
AUX-1 (DIGITAL)
IN
OUT
TRIG/REC
IN
VOLTAGE
AC FUSE
T4A
! SELECTOR
220V
RAL / HLD
9.6 / 19.2
TRG S/M
PTRG OFF/ON
240V
DC IN
STAND BY
AC IN
DC BREAKER
XLR 32F
S
HR
CANNON
OPTION SLOT 2
D4
D3
D2
OPTION SLOT 1
D1
LSB DIGITAL
OUTPUT
ANALOG
8
7
6
5
4
3
2
1 OUTPUT
!§
!§ Option slots
Insert optional modules here. The modules can be inserted as follows.
OPTION SLOT 1 : SDX SCSI emulation board, high-speed SCSI transfer board
OPTION SLOT 2 : Channel expansion board, bit stream board, MPEG video board
Analog Output Connectors
VOLTAGE
AC FUSE
T4A
8 7 6 5 4 3 2 1
! SELECTOR
!
NC
REC
% / dB
MST / SLV
IRIG ON / OFF
APD OFF / ON
(UP / DOWN)
220V
RAL / HLD
9.6 / 19.2
TRG S/M
PTRG OFF/ON
240V
DC IN
STAND BY
AC IN
DC BREAKER
XLR 32F
CANNON
OPTION SLOT 1
ANALOG
8
7
6
5
4
3
2
1 OUTPUT
!•
!¶
!¶ ANALOG OUTPUT connectors
Used to output analog data signals from channels 1 to 8.
Connect BNC cables (sold separately) to the corresponding connectors.
!• Output level adjustment potentiometers
Used to adjust the output level of the analog data signals for channels 1 to 8 manually.
Note
An effective connector and potentiometer differ in accordance with the channel mode.
Be sure to comply with the indication of each channel.
Channel mode
Effective channel
2
1, 2
4
1 to 4
8
1 to 8
16 (When expanded)
1 to 16
3-27
LSB Digital Output Connectors
9
8
25
6
7
24
21
22
23
19
20
18
17
16
15
14
1
5
4
3
2
13
12
10
11
9
8
7
6
5
4
3
2
1
EXT. CONT
REMOTE
COM
AUX-2 (IRIG-B)
IN
OUT
SYNC
AUX-1 (DIGITAL)
IN
OUT
TRIG/REC
IN
S
HR
OPTION SLOT 2
D4
D3
D2
D1
LSB DIGITAL
OUTPUT
!ª
!ª LSB DIGITAL OUTPUT connectors
Used to output LSB digital data signals to digital channels D1 to D4.
Connect BNC cables (sold separately) to the corresponding connectors.
Note
An effective connector differs in accordance with the channel mode.
Be sure to comply with the indication of each channel.
3-28
Channel mode
Effective channel
1
1
2
1, 2
4
1 to 4
3-3 Left Side Panel
2
1
3
BKW-L601
DO NOT PUT RECORDER ON THIS SIDE.
OTHERWISE BATTERY ADAPTER MAY BREAK.
この面を下向きに置かないでください。
バッテリー装着アダプターの破損を防止するためです。
2-902-854-01
1 Battery pack mount
Mount the BP-L60/L60A or BP-L90/L90A battery pack (both sold separately) here.
Hold the battery pack in your hand, align the grooves with the guides on the battery
pack mount, and slide the battery pack into place.
2 Eject button
Press this button to remove the battery pack.
! CAUTION
The battery pack is heavy and occasionally hot, so take care not to drop it.
3 Filter (Ventilation slits)
These slits are used to take in air to cool the inside of the recorder.
The filter protects dust from entering inside the recorder.
! WARNING
• To prevent the inside of the recorder from overheating, do not block the filter.
• Do not place hot objects on the left side of the recorder.
• Leave a space of at least 50 mm between the left side of the recorder and any other
object.
! CAUTION
• Dust accumulates easily on the filter, so that clean or replace it on occasion. (Replace
it every once a month, depending on how dirty it has become.)
• Be sure attach the filter after cleaning.
• Be sure to order the SIR dust filter to the Sony service division when replacing the
filter.
Cleaning and replacing the filter
The filter cover is fixed to the unit with Velcro.
Draw forward the upper frame of the filter cover window to remove the filter cover and
the filter, and then perform a cleaning or replacement.
3-29
3-4 Right Side Panel
1
2
SIR-1000W Ser.
Sony Precision Technology Inc.
MADE IN JAPAN
2-902-848-01
1 Ventilation fans
These fans cool the inside of the recorder.
! WARNING
• To prevent the inside of the recorder from overheating, do not block the air outlet.
• Leave a space of at least 50 mm between the right side of the recorder and any other
object.
! CAUTION
Regardless of the STAND BY switch position, the ventilation fans rotate while the
battery pack is being charged.
2 Speaker
Used to playback the sound of monitor channel or voice channel.
3-30
4 Preparations
4-1 Connecting the Power Supply
AC Power Supply
1
Set the AC voltage selector switch to 100/120 V or 220/240 V according to the voltage
to be used.
2
Connect the AC power cord (supplied) to the AC IN connector, and supply either AC
90 to 132 V (for 100/120 V setting) or AC 198 to 250 V (for 220/240 V setting ) to the
recorder.
9
8
25
6
7
24
21
22
23
19
20
18
17
16
15
14
1
4
3
2
13
12
11
10
9
8
7
AUX-2 (IRIG-B)
IN
OUT
SYNC
AUX-1 (DIGITAL)
IN
OUT
TRIG/REC
IN
! SELECTOR
!
5
6
5
4
3
2
1
REMOTE
COM
VOLTAGE
AC FUSE
T4A
8 7 6 5 4 3 2 1
EXT. CONT
220V
RAL / HLD
9.6 / 19.2
TRG S/M
PTRG OFF/ON
% / dB
MST / SLV
IRIG ON / OFF
APD OFF / ON
(UP / DOWN)
240V
DC IN
STAND BY
AC IN
DC BREAKER
XLR 32F
S
HR
CANNON
OPTION SLOT 2
D4
D3
D2
OPTION SLOT 1
D1
LSB DIGITAL
OUTPUT
ANALOG
8
7
6
5
4
3
2
1 OUTPUT
! WARNING
• When the AC voltage selector switch is set to AC 100/120 V, supplying AC 198 to 250 V
may damage the recorder’s internal circuitry.
• When the AC voltage selector switch is set to AC 220/240 V, the recorder will not
operate when supplied with AC 90 to 132 V.
• The AC power cord has a safety earth. Be sure to connect the power cord to an earthed
socket.
• When using a plug adapter (3-pin to 2-pin) for the AC power cord, be sure to connect
the green wire to earth.
!
CAUTION
• Make sure that spike noise is not included when taking AC power from an invertor, etc.
• When the recorder is connected to an AC power source and the battery pack mounted
on the battery pack mount on the left side of the recorder is charging, the charging
function operates and the ventilation fans on the right side rotates even when the
STAND BY switch on the rear panel is set to OFF. Once charging is completed the
ventilation fans stop rotating automatically.
4-1
Operation on DC Power Supply
Connect the DC power cord (supplied) to the DC IN connector, and supply DC 12 V (allowable
11 to 30 V) to the recorder.
9
8
25
6
7
24
21
22
23
19
20
18
17
16
15
14
1
4
3
2
13
12
COM
11
10
9
8
7
AUX-2 (IRIG-B)
IN
OUT
SYNC
AUX-1 (DIGITAL)
IN
OUT
TRIG/REC
IN
! SELECTOR
!
5
6
5
4
3
2
1
EXT. CONT
REMOTE
VOLTAGE
AC FUSE
T4A
8 7 6 5 4 3 2 1
% / dB
MST / SLV
IRIG ON / OFF
APD OFF / ON
(UP / DOWN)
220V
RAL / HLD
9.6 / 19.2
TRG S/M
PTRG OFF/ON
240V
DC IN
STAND BY
AC IN
DC BREAKER
XLR 32F
S
HR
CANNON
OPTION SLOT 2
D4
D3
D2
OPTION SLOT 1
D1
LSB DIGITAL
OUTPUT
ANALOG
8
7
6
5
4
3
2
1 OUTPUT
! WARNING
Applying excess voltage may damage the recorder’s internal circuitry.
!
CAUTION
• The polarities of the DC power cord are red = positive and black = negative.
• The connector pin assignment is Pin 1 = positive, Pin 2 = negative and Pin 3 = frame
GND.
1
2
3
• When the recorder is supplied from a specified AC power source, the AC power source
takes priority.
• Supply DC power from the power supply unit that output voltage and output power not
exceed 30 V, 150 W.
• If there is a possibility that the DC power source drops less than 11 V during backup the
battery, be sure not to disconnect the battery.
4-2
Operation Using the Battery Pack
Mount the battery pack BP-L60/L60A or BP-L90/L90A (both sold separately) on the
battery pack mount on the left side of the recorder.
BKW-L601
D
OTO N
OT
こ HERW
PU
バッの面 ISE
テリ を
ー装下 BATT
向き ER
着ア
ダプ に Y
ター置かAD
の破 な APTE
損を い
R
防止でく MA
する だ Y
ためさ BREA
ですい。 K.
。
TR
EC
OR
DE
RO
N TH
IS
SID
2-90
E.
2-85
4-01
C
K
LO
E
C
K
C
H
E
F
New and fully charged batteries can be used continuously for the times shown below:
Battery
Normal Mode
Power Save Mode
2 to 8 ch mode
16 ch mode
2 to 8 ch mode
16 ch mode
BP-L60/L60A
Approx. 40 min.
Unusable
60 min.
Unusable
BP-L90/L90A
Approx. 70 min.
20 min.
120 min.
Approx. 60 min.
!
CAUTION
• Do not use only other battery packs than above.
• When using an extension unit or an option board, use BP-L90/L90A.
• Use a fully charged battery pack. To check whether the battery pack is fully charged,
press the CHECK button on the battery pack; if the “F” LED lights, the battery pack is
fully charged.
• When the recorder is supplied from a specified external AC or DC power source, the
external source takes priority.
• If the recorder is not to be used for a long time, remove the battery pack from the recorder.
• Supply DC power (more than 11 V) to the recorder and expansion unit when back up
the recorder with battery pack in 16 channel mode of DC operation.
• Operation time shown in above table become shorter when the optional board is used.
4-3
4-2 Cartridges
Cartridges
To record, playback, and store data in the best condition, be sure to keep the following
precautions.
!
CAUTION
• When turning off the recorder’s main power, be sure to remove the cartridge before
setting the STAND BY switch to OFF. If the cartridge is left in the recorder with the main
power off for a long time, changes in the temperature and humidity may cause tape to
stretch or shrink, and condensation may cause it to stick to the tape transport system.
• The cartridge is designed so that it is difficult to touch the tape with your fingers, but be
sure to avoid touching the tape if you open the lid.
• Be sure to avoid any contact with terminals of the cartridge.
• Only the following cartridges can be used:
Model
Manufacturer
SDX1-25C (with MIC)
SDX-T3C (with MIC)
SONY
SDX-T3N (without MIC)
Using cartridges with MIC is recommended, as data can be accessed more quickly using
the TOC data stored in the MIC.
4-4
Loading a Cartridge
1
2
Set the STAND BY switch to ON, and check that the POWER LED lights.
Open the cartridge lid by pulling it forward with your finger.
POWER LED
POWER
BATT
OVR 1 1/
dB
%
OVR
+2
+100
0
–6
2
0
-20
LOADING
-40 -100
EJECT
BOD
REW
FF EOD
FWD
STOP
REC
OVR
PAUSE
CH
1-4
S I R -10
INS
ANALOG
INPUT
3
1
± 100vpk
3
2
100k
4
5
6
7
8
Insert the cartridge. Press at the location indicated by the arrow in the following
illustration. Once the cartridge is pressed part-way in, it is loaded automatically.
During loading the LOADING LED blinks; when loading is completed, the LED lights
continuously.
Note
If the cartridge is not equipped with MIC, loading and unloading may take a longer
time.
POWER
BATT
OVR 1 1
dB
%
OVR
+2
+100
0
–6
0
-20
LOADING
-40 -100
EJECT
BOD
REW
FF EOD
FWD
STOP
REC
OVR
PAUSE
CH
LOADING LED
3
4
1-4
S I R -1
INS
ANALOG
INPUT
1
2
± 100vpk
3
100k
4
5
6
7
8
Close the cartridge lid by pressing it with your finger.
! CAUTION
• The film of the cartridge insertion slot prevents dust from entering into the tape transport
portion, therefore be sure not to peel it off.
• Pressing the cartridge too strongly may cause malfunctions or damage to the tape
transport.
• The cartridge cannot be loaded when the main power is off.
• The cartridge cannot be loaded when the mechanical malfunction error code is displayed
on the LCD screen. In this case, set the STAND BY switch to OFF, then ON again, and
try loading once more.
4-5
Ejecting the Cartridge
2, 4
POWER
BATT
Advanced
Intelligent
Tape
Cartridge lid
LOADING
LOADING LED
EJECT
BOD
REW
FF EOD
FWD
STOP
REC
PAUSE
1
1
Press the EJECT button to unload the cartridge. During unloading the LOADING LED
blinks; when unloading is completed the LED turns off.
Note
Cartridges without MIC are rewound to the BOD and then ejected.
2
3
Pull the cartridge lid forward with your finger to open it.
Nip the left and right ends of the cartridge with your fingers and pull it out.
3
POWER
BATT
OVR 1 1
dB
%
OVR
+2
+100
0
2
–6
0
-20
LOADING
-40 -100
EJECT
BOD
REW
FF EOD
FWD
STOP
REC
OVR
PAUSE
CH
1-4
S I R -1
INS
ANALOG
INPUT
4
1
2
± 100vpk
3
100k
4
5
6
7
8
Close the cartridge lid with your finger.
! CAUTION
If the recorder is placed so that the front panel is facing upwards, the cartridge may not
eject successfully.
4-6
Preventing Overwrite to a Recorded Tape
To avoid accidentally writing over important data, set the safety tab on the cartridge to the
position shown below, so that the write protection hole is open.
If an attempt is made to record on the tape in this condition, the cartridge will be ejected.
REC
Recording is enabled.
…
(Write protection hole close)
Recording is disabled.
…
(Write protection hole open)
SAVE
Cleaning Tape
If the (recording error) mark is displayed frequently, clean the scanning heads using
supplied cleaning tape.
When the cleaning tape is loaded, it is ejected automatically after cleaning the heads.
4-7
4-3 Self-Check
Before performing the operations described in the following chapters, perform the selfcheck to make sure that the recorder is functioning correctly.
The details of the self-check are shown below:
CAL (Calibration) Mode
SLF (Self-check) Mode
Contents
Tape transport system check
DC offset error compensation
Recording/playback head check
Gain error compensation
Recording/playback amplifier check
Required time
Approx. 8 min
Approx. 1 min
SLF (Self-Check) Mode
Bar meter area
SPD/BCM
dB
%
OVR 1 1/2 1/4 1/8 1/16 1 2
SPD
AUX
EXT TC
EXP SYN
ID
RANGE
M
OVR
+2
+100
0
–6
MONI
RANGE
SPEED
V X1/
S- TIME
ADDRESS REMAIN T - T I M E
Y
M
D
H
M
S
0
OFFSET
A
M
A
SEARCH
OUT/TSG
(UNIT)
ID/UTL
MRK/SLF
SHIFT
CH
-20
-40 -100
OVR
CH
(CH)
CAUTION
1-4 5-8
S I R -1000W
PNL LOK
9-12 13-16
PK-CLR
DATA
ALL CH SELECT
LOAD
CLOCK
VOL
PHONE
ANN/P-SV
MIC
2
INSTRUMENTATION DIGITAL DATA RECORDER
1
2
Turn the STAND BY switch ON and insert a cartridge.
3
If no errors are detected by the SLF mode, the “SLF” in the bar meter area is
extinguished.
If any error is detected, the corresponding “SLF NG” appears in the bar meter area.
Refer to the explanations of the error codes in section 4-4 for the appropriate actions.
4
To end the self-check part-way, press the STOP key.
Enter the SLF mode by pressing the SHIFT key and then pressing the MRK/SLF key.
“SLF” appears in the bar meter area and the self-check is executed. During the selfcheck, the OVR marks in the bar meter area indicate the progress.
Note
If the cartridge is record-protected (the write protect hole is open), it will be ejected
automatically. Set the safety tab to the “REC” position to enable recording, and insert the
cartridge again.
4-8
CAL (Calibration) Mode
This recorder was calibrated prior to shipment, and these settings are stored in memory.
While frequent calibration is unnecessary, the recorder should be calibrated a few times
a year.
Bar meter area
SPD/BCM
dB
%
OVR 1 1/2 1/4 1/8 1/16 1 2
SPD
AUX
EXT TC
EXP SYN
ID
RANGE
M
+2
+100
0
–6
MONI
SPEED
V X1/
S- TIME
ADDRESS REMAIN T - T I M E
Y
M
D
H
M
S
0
RANGE
OFFSET
A
M
A
SEARCH
OUT/TSG
(UNIT)
ID/UTL
MRK/SLF
SHIFT
CH
-20
-40 -100
OVR
CH
(CH)
CAUTION
OVR
1-4 5-8
S I R -1000W
PNL LOK
9-12 13-16
PK-CLR
DATA
ALL CH SELECT
LOAD
CLOCK
VOL
PHONE
MIC
ANN/P-SV
2
INSTRUMENTATION DIGITAL DATA RECORDER
1
2
Turn the STAND BY switch ON.
3
If no errors are detected by the CAL mode, the “CAL” in the bar meter area is
extinguised.
If any error is detected, the corresponding error code appears in the bar meter area.
Refer to the explanations of the error codes in section 4-4 for the appropriate actions.
4
To end the calibration part way, press the STOP key. The calibration may stop at the
end of each bandwidth.
Enter the CAL mode by pressing the SHIFT key and then pressing the MRK/ SLF key
twice within 1 second. “CAL” appears in the bar meter area and calibration is executed.
During the calibration, the OVR marks in the bar meter area indicate the progress.
! CAUTION
• Start calibration after 15 minutes of the power on.
• Perform calibration under the actual operating condition.
• Turn on the power again when the CAL mode will be finished partway.
4-9
4-4 Error Codes
When the recorder malfunctions during self-check, calibration, recording or playback
operation, the error codes shown below appear in the bar meter area. Take the appropriate
actions in accordance with the corresponding explanations.
In addition, when using the recorder in a dusty surrounding, the data could not be played
back (or verified during recording) and also an error code (ET03) is displayed.
In such a case, perform a play back inside a room.
If the error is not remedied after the appropriate action has been taken or if the displayed
error code is not listed in this manual, contact service engineer.
Note
When the power cannot be turned ON even if the standby switch is set to ON or when the
key is inoperative, set the standby switch to OFF, disconnect the power cord, then connect
the power cord again.
Error Code
Location
EP03
Abnormality
Power failure
How to care
Consult with service engineer
Battery charge error
Replace the battery with new one
DC/DC converter overheat
Operate in the allowable environmental temperature
EP31
SCX-32 low voltage
Supply DC voltage within allowable range
Ed20
RS-232C communication error
Input proper commands
EP11
EP30
Power Supply
Remote control unit communication error
Confirm connection of the remote control unit
Ed40
System controller/
Synchronized operation communication error
Stop the recorder and put the mode again
Ed50
digital signal
Analog communication error
Confirm connection of the extension cable
Ed30
Confirm the power to the expansion unit
processor
Consult with service engineer
DSP communication error
Consult with service engineer
Power communication error
Disconnect the power cord then connect it back
EA20
Recording system CAL error
Consult with service engineer
EA30
Playback system CAL error
Consult with service engineer
EA40
No playback error
Confirm setting of the channel mode and tape speed
Ed60
Ed70
Power Supply
Confirm existence of the SBS-10A/S board
when playing back the tape in digital mode
EA50
ADA board version error
Consult with service engineer
EA60
ADA flash memory error
Consult with service engineer
EA70
SCX ID error
Be sure not to put the same SCX ID number
EA80
ADA board error
Confirm connection of the extension cable
Analog system
Confirm the power to the expansion unit
Consult with service engineer
4-10
Error Code
Location
ET03
How to care
Abnormality
Media error or Error for dust
Replace the cartridge tape or apply cleaning tape
because the recording is unable to continue
Play back a tape inside a room.
If still malfunctions, contact your local service
center.
ET04
Hardware error
Turn off the recorder and on again
ET08
EOD miss-detection
Rewind the tape until BOD or EJECT
ET**
Hardware error
Warm up the recorder fifteen or more minutes,
Drive
then turn off the recorder and on again
Consult with service engineer
SLF NG
Media or Hardware error
Replace the cartridge or apply cleaning tape
Consult with service engineer
EX10
STB-10 board error
Consult with service engineer
EX20
STB-30 board error
Consult service engineer
EX21
STB-30 communication error
Input proper commands
EX30
Sync setting error
Consult with service engineer
Peripherals
Confirm master/slave setting or connection
of the sync cable
EX31
Target error
Media error or no synchronized PB data
EX32
Synchronized Recording/Playback
error
Start recording or playback again
EX33
Sync recording error
Confirm the power of master unit
Set the master to the STOP mode, then start
synchronized recording by operating the master
4-11
4-5 Warning Display
When a malfunction occurs in the recorder, the warning marks shown below blink in the
CAUTION area, and a buzzer will sound. Take the appropriate actions in accordance with
the explanation for the corresponding caution item.
If the error is not remedied after the appropriate action has been taken or if the displayed error
code is not listed in this manual, contact service engineer.
CAUTION area
dB
%
OVR 1 1/2 1/4 1/8 1/16 1 2
SPD
AUX
EXT TC
EXP SYN
ID
CAUTION
OVR
+2
+100
0
–6
MONI
SPEED
V X1/
S- TIME
ADDRESS REMAIN T - T I M E
Y
M
D
H
M
S
0
-20
-40 -100
OVR
CH
RANGE
CH
1-4 5-8
S I R -1000W
9-12 13-16
PK-CLR
ALL CH SELECT
LOAD
CLOCK
(Low DC voltage)
Blinks when the voltage of the battery or the external DC power supply has dropped
below the specified value (11 V). Replace the battery pack with a fully charged one, or
supply the specified external DC voltage (11 to 30 V).
Power supply
Operative unit
Specified lower
limit voltage
Specified external
DC voltage
Main unit
Main unit only
11 V
11 to 30 V
Main unit + expanded unit
15 V
15 to 30 V
Main unit + expanded unit
11 V each
11 to 30 V
Main unit +
expanded unit
! CAUTION
Be sure to take the above measures as soon as possible when this mark is displayed. If not,
the recorder may cause malfunction.
4-12
& (Dew condensation)
Lights up when the DEW function is ON and condensation occurs in the tape running
system such as when the recorder is transferred from cold to warm places.
Turn the STAND BY switch to ON and warm up the recorder until this mark goes off,
without inserting a cartridge.
Details of display when the DEW function is ON
CAUTION
Display
LCD Display
Recorder State
Remarks
—
LO T WAIT
HI T WAIT
180S – 000S
When internal temperature is less than 5 °C
When internal temperature is 50 °C or more
During detection of dew condensation
Displayed until internal temperature rises 5 °C or more
Displayed until internal temperature falls less than 50 °C
Displays remaining time to detection of dew condensation
& mark
lights up
WARM WAIT
600S – 000S
When condensation is detected
During clearing of dew condensation
Displayed during warm up
Displays remaining time to clearing of dew condensation
!
CAUTION
• In environment where the temperature or humidity may change, be sure to turn ON the
DEW function.
• After using the recorder, eject the cartridge and then turn OFF the STAND BY switch
to prevent tape sticking to the scanning head drum due to condensation during storage.
• Leave a space of at least 50 mm between the both side of the recorder and any other
object.
4-13
(Recording/Playback Error)
Recording Error
Recording error is indicated when the data supply to the tape cannot catch up and the FIFO
memory becomes full (FIFO overflow).
When the mark is displayed frequently, the cause may be scratches, wrinkles or dusts
in the tape, so replace the tape with a new one. If this does not solve the problem, clean
the heads using the supplied cleaning tape. If the problem still persists, contact service
engineer.
Playback Error
When the playback data contains an error that cannot be corrected, the recorder rewinds
the tape and attempts to read the data again (retry). During this retry operation, the data
remaining in the FIFO memory is output until the correct data is read. If the retry operation
allows the correct data to be read before the FIFO memory is emptied, playback continues
normally and the mark is not displayed. If the retry operation repeats and the FIFO
mark is displayed and the output data is interrupted.
memory becomes empty, the
As shown above, the SIR-1000W allows error-free data reading by verifying the data in
real-time as it is recorded, and then rewinding the tape and playing back the data again
when an error occurs during playback. When transferring data to a computer using the
optional PCscanIII software, there is no limit on the number of retries using the FIFO
underflow, allowing playback with even fewer errors.
Note
If playing back the tape recorded in compression mode with the recorder with less than
version 30, mark will appear just after starting playback.
4-14
4-6 Source Mode/Tape Mode
Source Mode
When the recorder is in the E-E, REC-PAUSE, or REC mode, or has stopped after being
in one of these modes, it automatically switches to the source mode. In this mode, source
data (values set in the recorder) is displayed for the tape position information (ID number,
ADDRESS, and realtime clock) and the amplifier setting information (input range value,
input DC offset value, and output level value).
In the source mode, press the SELECT key to sequentially change the contents displayed
as follows:
SOURCE
Address
(± h/m/s)
Amount of tape remaining
(h/m)
Source date
(y/m/d)
REMAIN
S-TIME
SOURCE
ADDRESS
Y
H
M
M
Source time
(h/m/s)
S-TIME
SOURCE
D
S
Y
H
M
M
SOURCE
D
S
Y
H
M
M
D
S
Y
H
M
M
D
S
Tape Mode
When the recorder is in the FWD mode, or has stopped after being in the FWD mode, it
automatically switches to the tape mode. In this mode, tape data (values recorded on the
tape) is displayed for the tape position information (ID number, ADDRESS, and realtime
clock) and the amplifier setting information (input range value, input DC offset value, and
output level value).
In the tape mode, press the SELECT key to sequentially change the contents displayed
as follows:
ADDRESS
Y
H
TAPE
M
M
D
S
Y
H
Address
(± h/m/s)
REMAIN
M
M
T-TIME
TAPE
D
S
Amount of tape remaining
(h/m)
Y
H
M
M
Tape date
(y/m/d)
T-TIME
TAPE
D
S
Y
H
M
M
D
S
Tape time
(h/m/s)
TAPE
Note
If the tape position information or amplifier setting information is altered in the STOP
mode, the mode automatically changes to the source mode.
4-15
4-7 Fan Control Mode
• When the ANN/P-SV key is pressed for 3 seconds or more after pressing the SHIFT
key, the recorder enters into the fan-control mode. This mode allows the ventilation
fans to be stopped during the REC mode as long as the internal temperatures of the
SIR-1000W and SCX-16W are low, making it convenient for recording music and
other applications where silence is required. In the fan control mode, the LED to the
upper right of the ANN/P-SV key blinks and a rectangular mark appears at the right
edge of the tape position display area on the LCD screen.
1) In the fan control mode, the rectangular mark appears steadily on the LCD screen
when the internal temperature is low, and blinks to alert the operator when the
internal temperature rises above the cautionary temperature.
If the temperature rises further and exceeds the critical temperature, the ventilation
fans start to rotate automatically, the rectangular mark disappears and the recorder
exits the fan control mode.
2) From cold start, the relations of fans stop time and the ambient temperature is
approximately as shown below:
Channel configuration
Ambient temperature
20°C (68°F)
25 min
8 or 16 channel
30°C (86°F) 40°C (104°F)
17 min
10 min
3) When the recorder internal temperature is warm after continuous operation, the relations of
fans stop time and the ambient temperature is approximately as shown below:
Channel configuration
Ambient temperature
20°C (68°F)
15 min
8 or 16 channel
30°C (86°F) 40°C (104°F)
7 min
—
4) Like the P-SV mode, the analog playback circuitry and the LCD panel backlight
are turned off in the fan control mode.
5) To exit the fan control mode, press the SHIFT key and then press the ANN/P-SV
key for 3 seconds or more.
Unit's internal temperature
Fan driving temperature t 2
Warning temperature t 1
Ambient temperature t 0
When the FAN CONTROL
mode remaind OFF
Time
POWER ON
FAN CONTROL
mode ON (manual)
Mark
Ventilation fan
4-16
Lit
FAN CONTROL
mode OFF (auto)
FAN CONTROL
mode ON (again)
FAN CONTROL
mode ON (manual)
Blinking
Off
Unlit
On
Lit
POWER OFF
Blinking
Unlit
Off
On
5 Data Recording/Playback
5-1 Connecting the Signals
Connecting the Analog Data Signals
Using BNC cables (sold separately), connect the ANALOG INPUT connector on the front
panel to the analog signal source for each channel.
If necessary, use a BNC cable to connect the ANALOG MONITOR connector to an
oscilloscope or other measuring device.
POWER
BATT
SPD/BCM
dB
Advanced
Intelligent
Tape
%
OVR 1 1/2 1/4 1/8 1/16 1 2
SPD
AUX
ID
FF EOD
FWD
STOP
RANGE
REC
OVR
PAUSE
SPEED
CH
S- TIME
ADDRESS REMAIN T - T I M E
Y
M
D
H
M
S
-40 -100
REW
RANGE
OFFSET
A
M
A
SEARCH
OUT/TSG
ID/UTL
MRK/SLF
(UNIT)
V X1/
0
-20
LOADING
BOD
(CH)
CAUTION
M
MONI
–6
EJECT
EXT TC
EXP SYN
OVR
+2
+100
0
CH
1-4 5-8
S I R -1000W
PK-CLR
SHIFT
PNL LOK
9-12 13-16
DATA
ALL CH SELECT
LOAD
CLOCK
VOL
PHONE
MIC
ANN/P-SV
INSTRUMENTATION DIGITAL DATA RECORDER
ANALOG
INPUT
≤ ± 100vpk
1
2
100k
3
4
5
6
7
≤ ± 10vpk 10k
LSB DIGITAL
INPUT
8
D1
D2
D3
ANALOG
MONITOR
D4
REF
Oscilloscope
Signal source
! WARNING
Do not supply input signals exceeding ±100 Vpk, or the internal circuitry may be damaged.
!
CAUTION
• Keep the input voltage range via the ANALOG INPUT connectors to within ±26.6 Vpk.
• Do not simultaneously input signals with different ground levels.
• The input impedance is 100 k .
Connecting the LSB Digital Data Signals
Using BNC cables (sold separately), connect the LSB DIGITAL INPUT connector on the
front panel to the digital signal source for each channel.
POWER
BATT
SPD/BCM
dB
Advanced
Intelligent
Tape
%
OVR 1 1/2 1/4 1/8 1/16 1 2
SPD
AUX
–6
MONI
REW
FF EOD
FWD
STOP
(CH)
CAUTION
REC
OVR
PAUSE
CH
RANGE
RANGE
SPEED
CH
V X1/
S- TIME
ADDRESS REMAIN T - T I M E
Y
M
D
H
M
S
0
-40 -100
BOD
ID
M
-20
LOADING
EJECT
EXT TC
EXP SYN
OVR
+2
+100
0
1-4 5-8
S I R -1000W
M
A
OUT/TSG
ID/UTL
MRK/SLF
(UNIT)
SHIFT
PNL LOK
9-12 13-16
PK-CLR
OFFSET
A
SEARCH
DATA
ALL CH SELECT
LOAD
CLOCK
VOL
PHONE
MIC
ANN/P-SV
INSTRUMENTATION DIGITAL DATA RECORDER
ANALOG
INPUT
≤ ± 100vpk
1
2
3
100k
4
5
6
7
8
LSB DIGITAL
INPUT
≤ ± 10vpk 10k
D1
D2
D3
D4
ANALOG
MONITOR
REF
Signal source
5-1
5-2 Settings for Recording
Before starting to record data, be sure to set the following items:
• Channel mode (BCM)
• Tape speed (SPD)
• Input range (RANGE)
• Input DC offset (OFFSET)
• Realtime clock (CLOCK)
When the recorder’s power switch is ON, the display appears as shown below.
ID display area
SPD
dB
%
OVR 1 1/2 1/4 1/8 1/16 1 2
SPD
AUX
EXT TC
EXP SYN
ID
CAUTION
OVR
+2
+100
0
MONI
–6
MONI
SPEED
V X1/
S- TIME
ADDRESS REMAIN T - T I M E
Y
M
D
H
M
S
0
-20
-40 -100
OVR
CH
1-4 5-8
S I R -1000W
5-2
RANGE
CH
9-12 13-16
PK-CLR
ALL CH SELECT
LOAD
CLOCK
RANGE
Index
(other than ID)
Setting the Analog Channel Mode (BCM)
Press the SHIFT key and SPD/BCM key, then press ; or : key to set the analog channel
mode.
The bandwidth for the corresponding channel modes are as follows:
Full Analog Mode
4 ch mode
8 ch mode
16 ch mode
Expansion channel units
—
—
1 units
1 (normal speed)
DC to 160 kHz
DC to 80 kHz
DC to 40 kHz
1/2
DC to 80 kHz
DC to 40 kHz
DC to 20 kHz
1/4
DC to 40 kHz
DC to 20 kHz
DC to 10 kHz
1/8
DC to 20 kHz
DC to 10 kHz
DC to 5 kHz
1/16
DC to 10 kHz
DC to 5 kHz
DC to 2.5 kHz
Tape speed
Bandwidth
Analog Digital MIX Mode (operated with SBS-10A/S)
Tape speed
Bandwidth
2 ch mode
4 ch mode
8 ch mode
1 (normal speed)
DC to 160 kHz
DC to 80 kHz
DC to 40 kHz
1/2
DC to 80 kHz
DC to 40 kHz
DC to 20 kHz
1/4
DC to 40 kHz
DC to 20 kHz
DC to 10 kHz
1/8
DC to 20 kHz
DC to 10 kHz
DC to 5 kHz
1/16
DC to 10 kHz
DC to 5 kHz
DC to 2.5 kHz
! CAUTION
“—” indicates an impossible setting.
Note
Regarding full digital mode, refer to the instruction manual of SBS-10A/S (sold separately).
Setting the LSB Digital Channel Mode (BCM)
Press the SHIFT key, press the SPD/BCM key twice, then press the ; or : key to set the
LSB digital channel mode.
The internal sampling frequency of the LSB digital channels are as follows:
Tape speed
Bandwidth
1 ch mode
2 ch mode
4 ch mode
1 (normal speed)
768 kHz
384 kHz
192 kHz
1/2
384 kHz
192 kHz
96 kHz
1/4
192 kHz
96 kHz
48 kHz
1/8
96 kHz
48 kHz
24 kHz
1/16
48 kHz
24 kHz
12 kHz
Note
Be sure to use the LSB digital channel whose bit rate of input digital data is lower (less than
1/2) to the internal sampling frequency.
5-3
Setting the Tape Speed (SPD)
Set the tape speed by pressing the SPD/BCM, ; and : keys. The recording times for the
corresponding tape speeds are as follows:
Tape speed
Recording time (170 m tape)
1 (normal speed)
2h
1/2
4h
1/4
8h
1/8
16 h
1/16
32 h
Setting the Input Range (RANGE) (Analog channel)
Manual
1 To select the M-RANGE (manual range setting) mode, press the RANGE key.
2
3
Press the ; or : key to select the channel.
Press the 8 or 9 key to select one of the input ranges below:
8 key
9 key
→
←
←
←
←
→
→
→
→
←
RANGE display
20
10
5
2
1
0.5
Input range (Vpk)
±20
±10
±5
±2
±1
±0.5
The left and right arrows in the table below indicate the direction of change when the key
is pressed.
Note
For example, the 20 V range is the range where the bar meter scale is ±100% or 0 dB when
the input voltage is +20 Vpk, –20 Vpk, or ±20 Vpk. The same applies to other values.
Automatic (After setting to E-E or REC-PAUSE mode)
To select the A-RANGE (automatic range setting) mode, press the SHIFT key and then
the RANGE key.
1
2
The peak value of the input level for each channel is automatically detected and held.
The relationship between the input levels and setting ranges are as shown below.
3
Press the RANGE key once after the barmeter shakes, is set the input ranges for all
channels corresponding to the last peak values being held.
Note
Input level
11 V
or more
5.5 to less
than 11 V
2.2 to less
than 5.5 V
1.1 to less
than 2.2 V
0.55 to less
than 1.1 V
Less than
0.55 V
Input Range
(Vpk)
±20
±10
±5
±2
±1
±0.5
When input signals include unnecessary DC components, set the input DC offset
(described next) before setting the input range.
5-4
Setting the Input DC Offset (OFFSET) (Analog channel)
Manual
1 To select the M-OFFSET (manual offset setting) mode, press the OFFSET key.
2
3
Press the ; or : key to select the channel.
4
The input DC offset values for each channel are displayed in the tape position display
area. The left and right arrows in the table below indicate the direction of change when
the key is pressed.
Each time the 8 or 9 key is pressed, the offset changes by +1% or –1%. Press
continuously to change the offset faster.
←
8 key
←
→
→
OFFSET display
100%
±0%
–100%
Input DC offset
+100%
±0%
–100%
9 key
Note
For example, a +100% offset indicates that, when the input range is ±20 Vpk, the
waveform is shifted upwards by superimposing a DC voltage of +1.00 × 20 (V) = +20.0
(V) on the input signal. The same applies to other values.
Automatic
To select the A-OFFSET (automatic offset setting) mode, press the SHIFT key and
then the OFFSET key.
1
2
The peak values for the plus and minus sides of the input signal for each channel are
automatically detected and the DC components calculated.
3
Press the OFFSET key once more after 3 seconds or more to set the input DC offset
values for all channels.
4
The input DC offset values for each channel are displayed in the tape position display
area.
5-5
Setting the Realtime Clock
Set the realtime clock of the recorder by the procedure below.
2, 5
SPD/BCM
dB
%
OVR 1 1/2 1/4 1/8 1/16 1 2
SPD
AUX
EXT TC
EXP SYN
ID
(CH)
CAUTION
RANGE
M
OVR
+2
+100
0
–6
MONI
SPEED
V X1/
S- TIME
ADDRESS REMAIN T - T I M E
Y
M
D
H
M
S
0
M
A
SEARCH
OUT/TSG
(UNIT)
ID/UTL
MRK/SLF
SHIFT
3, 5
CH
-20
-40 -100
OVR
CH
RANGE
OFFSET
A
1-4 5-8
S I R -1000W
PNL LOK
9-12 13-16
PK-CLR
DATA
ALL CH SELECT
LOAD
CLOCK
VOL
PHONE
MIC
ANN/P-SV
INSTRUMENTATION DIGITAL DATA RECORDER
8
LSB DIGITAL
INPUT
D1
D2
The digit that can
be set blinks.
5-6
D3
D4
1, 4, 6
ANALOG
MONITOR
1
Use a sharp-pencil or other pointed implement to press the CLOCK key once. This
selects the date setting mode, and the digit that can be set blinks.
2
3
4
Press the ; or : key to select the digit to be set.
5
6
As above, use the ;, :, 8 and 9 keys to set the time.
Press the 8 or 9 key to select the value.
Press the CLOCK key again to select the time setting mode. The digit that can be set
blinks.
Press the CLOCK key again to start the recorder’s realtime clock, which will then be
displayed by S-TIME.
In the REC mode, it will be recorded on the tape as realtime clock.
Test Signal (TSG) Mode
A test signal can be issued during the E-E, REC-PAUSE, and REC modes.
The recorder’s test signal is 16-bit digital data read from the ROM, so it can be used as a
high-precision reference signal.
2
SPD/BCM
EXT TC
(CH)
CAUTION
RANGE
M
SPEED
OFFSET
A
M
A
SEARCH
OUT/TSG
(UNIT)
ID/UTL
MRK/SLF
SHIFT
X1/
S- TIME
IN T - T I M E
D
S
M
PNL LOK
DATA
LOAD
CLOCK
VOL
PHONE
1, 3
MIC
ANN/P-SV
CORDER
1
To select the TSG (test signal) mode, press the SHIFT key and then the OUT/TSG key.
The test signal shown below is output to active channels according to the channel mode.
2
Select the type of test signal using the ; or : key. The selected test signal is displayed
in the bar meter area and output from the ANALOG MONITOR and ANALOG
OUTPUT connectors.
When an external test signal is selected, the signal input from the channel 1 (SIR1000W) or INPUT connector of channel 9 (SCX-16W) is input as the test signal for
channels 1 to 8 (SIR-1000W) and channel 9 to channel 16 (SCX-16W) of the same
recorder or channel expansion unit.
The left and right arrows in the table below indicate the direction of change when the
key is pressed.
; key
←
←
←
←
←
: key
→
→
→
→
→
Bar meter
display area
±100
AC
+100
DC
–100
DC
0V
EXT
Test signal
±100%AC
+100%DC
–100%DC
0V
External
The AC test signal frequency varies according to the set tape speed.
Tape speed
AC test signal
requency
3
1 (Normal speed)
1/2
1/4
1/8
1/16
1 kHz
500 Hz
250 Hz
125 Hz
62.5 Hz
To cancel the TSG mode, press the OUT/TSG key again, or press the STOP key.
! CAUTION
If recording is started in the TSG mode, the test signal is recorded for all channels and the
input data signal from the ANALOG INPUT connector is not recorded.
5-7
5-3 Recording Data
3
POWER
1
2
BATT
SPD/BCM
dB
Advanced
Intelligent
Tape
%
OVR 1 1/2 1/4 1/8 1/16 1 2
SPD
AUX
–6
REW
FF EOD
FWD
STOP
(CH)
CAUTION
RANGE
MONI
REC
OVR
PAUSE
CH
RANGE
SPEED
CH
V X1/
S- TIME
ADDRESS REMAIN T - T I M E
Y
M
D
H
M
S
0
-40 -100
BOD
ID
M
-20
LOADING
EJECT
EXT TC
EXP SYN
OVR
+2
+100
0
1-4 5-8
S I R -1000W
M
A
SEARCH
OUT/TSG
ID/UTL
MRK/SLF
(UNIT)
SHIFT
PNL LOK
9-12 13-16
PK-CLR
OFFSET
A
DATA
ALL CH SELECT
LOAD
CLOCK
VOL
PHONE
MIC
Microphone
ANN/P-SV
INSTRUMENTATION DIGITAL DATA RECORDER
ANALOG
INPUT
≤ ± 100vpk
1
2
3
100k
4
5
6
7
8
LSB DIGITAL
INPUT
≤ ± 10vpk 10k
D1
D2
D3
D4
ANALOG
MONITOR
Earphone
REF
Oscilloscope, etc.
4
1
Signal source
Load the cartridge.
When the TOC data cannot be used (see section 2-2), “TOC?” appears in the LCD
screen. Press the FF key to load the TOC information from the TOC area on the tape
into the recorder’s memory. When recording from the start of the tape (BOD), press
the REW key to rewind the tape to the BOD.
Note
The ID number increments each time recording starts, and a new ID number is assigned
for the next recording. In addition, a start ID is also attached each time recording starts to
allow start ID search. The ID number increments each time the ID key is pressed during
recording. Using this as an event mark allows events to be searched by ID number.
2
Select the E-E mode by pressing the REC key. The input signal can be monitored on
the display screen without recording data on the tape. Also, the signal can be output
from the ANALOG MONITOR and ANALOG OUTPUT connectors.
Note
Voice annotation channel can not be monitored from Speaker or Microphone.
3
4
Check the tape speed, channel mode, input range, input DC offset and other settings again.
Select the REC mode by pressing the FWD key while holding down the REC key. The data
signal, tape position information, and input setting information are recorded on the tape.
Note
The input data is sent to the FIFO memory from the instant the recorder enters the REC
mode. Therefore, the data from the start of recording can be recorded on the tape
regardless of the time taken for the tape transport system to reach the specified speed.
! CAUTION
• It is highly recommended that the recorder’s power be backed up by either external DC
or the battery when the primary power may be interrupted.
• Once overwriting starts, none of the old data remaining on the tape after the point where
overwritting stops can be played back. When overwriting from the start of the tape or
from part-way through the pre-recorded data, “ERA?” appears in the LCD screen. To
proceed with the recording, press the FWD key again while holding down the REC key.
• If ERA mode under sthe UTL mode is in OFF state, no REC mode can be performed,
and “ERA OFF” appears in the LCD screen.
5-8
Monitor
The analog data signal can be monitored in the E-E, REC-PAUSE, REC, and FWD modes.
1
2
Connect a BNC cable (sold separately) to the ANALOG MONITOR connector.
Press the ; or : key to select the monitor channel.
! CAUTION
The signal output from the ANALOG MONITOR connector can not be used for data analysis
because its characteristics differ from the output of each ANALOG OUTPUT connector.
REC-PAUSE (recording pause) Mode
To select the REC-PAUSE (recording pause) mode, press the PAUSE key in the E-E, or
REC mode.
If there is old data, “ERA?(erase)” appears in the screen.
To select the REC (recording) mode, press the PAUSE key again, or press the FWD key
while holding down the REC key. The signal are overwritten on the tape.
When keeping old data, press the STOP key while the “ERA?(erase)” warning mark
appears in the LCD screen.
Stopping and Restarting Recording
When the STOP mode is selected during recording, it will take a maximum of 10 seconds
after the STOP key is pressed to finish recording data, TOC and EOD. During this time,
the LED above the STOP key continues blinking, and none of the key operations accepted.
When recording is stopped, the TOC and EOD are written on the tape and the EOD LED lights.
When continuing to record after the last recording, if the tape has been moved to a position
other than the EOD using playback, etc., first press the FF key and make sure that the tape
is at the EOD (the EOD LED lights), then invoke the REC mode.
Note
If the power supply is cut off or away from allowed voltage range during the REC mode,
the recording stops without writing the TOC and EOD on the tape. When the power is
supplied again, this SIR-1000 displays “EOD WRT” and “WAIT” alternately on the LCD
screen and searches for the end of recording and write TOC and EOD automatically. After
this, usual operation can be performed.
5-9
ID Number
The ID number 001 is by default assigned to the first ID block on the tape. The ID number
increments by one automatically each time recording starts up to the maximum ID number
of 999.
ID number
SPD/BCM
dB
%
OVR 1 1/2 1/4 1/8 1/16 1 2
SPD
AUX
EXT TC
EXP SYN
ID
(CH)
CAUTION
RANGE
M
OVR
+2
+100
0
–6
MONI
SPEED
V X1/
S- TIME
ADDRESS REMAIN T - T I M E
Y
M
D
H
M
S
0
RANGE
M
A
SEARCH
OUT/TSG
(UNIT)
ID/UTL
MRK/SLF
SHIFT
CH
-20
-40 -100
OVR
CH
OFFSET
A
1-4 5-8
PNL LOK
9-12 13-16
S I R -1000W
PK-CLR
DATA
ALL CH SELECT
LOAD
CLOCK
VOL
PHONE
MIC
ID key
ANN/P-SV
INSTRUMENTATION DIGITAL DATA RECORDER
Incrementing the ID Number During Recording
To increment the ID number by one in the REC mode, press the ID key once.
Note
When new recording is performed or the ID key is pressed to increment the ID number
after a recording with an ID number of 999, the ID number changes to “000”. Thereafter,
the ID number is not incremented by additional recording or other operations, and all
subsequent recording blocks’ ID are 000. Note that real-time clock search cannot be
performed for portions with ID numbers of 000.
ADDRESS (address) Display
The ADDRESS automatically goes to 00H00M00S at the beginning of each recording
block (continuous recording area). These zeros are automatically set each time the REC
mode starts. The ADDRESS counts up according to the tape speed. For the normal speed,
the count increments each actual second.
dB
%
OVR 1 1/2 1/4 1/8 1/16 1 2
SPD
AUX
EXT TC
EXP SYN
ID
CAUTION
OVR
+2
+100
0
–6
MONI
SPEED
V X1/
S- TIME
ADDRESS REMAIN T - T I M E
Y
M
D
H
M
S
0
-20
-40 -100
OVR
CH
1-4 5-8
S I R -1000W
! CAUTION
RANGE
CH
ADDRESS display
9-12 13-16
PK-CLR
ALL CH SELECT
LOAD
CLOCK
Even if the ID key is pressed during the REC mode to increase the ID number, the address
continues to increase without being reset to 0.
5-10
REMAIN (Remaining Time) Display
The amount of time remaining for the tape assuming that recording will continue at the
current tape speed is displayed in hours and minutes.
dB
%
OVR 1 1/2 1/4 1/8 1/16 1 2
SPD
AUX
EXT TC
EXP SYN
ID
CAUTION
OVR
+2
+100
0
–6
MONI
SPEED
V X1/
S- TIME
ADDRESS REMAIN T - T I M E
Y
M
D
H
M
S
0
-20
-40 -100
OVR
CH
RANGE
CH
1-4 5-8
S I R -1000W
REMAIN display
9-12 13-16
PK-CLR
ALL CH SELECT
LOAD
CLOCK
! CAUTION
In the CAMP MODE (compressing mode), the REMAIN display shows the approximate
remaining tape time.
5-11
5-4 Data Playback
1
Use BNC cables (sold separately) to connect the ANALOG OUTPUT connectors and
the analysis monitor equipment, and the LSB DIGITAL OUTPUT connectors and the
monitor equipment respectively.
Analog channel
: Load impedance of above 10 k is recommended.
LSB digital channel : Load impedance of above 1 k is recommended.
8 7 6 5 4 3 2 1
!
9
8
25
6
7
24
21
22
23
19
20
18
17
16
15
14
1
4
2
3
13
12
11
10
9
8
7
6
5
4
3
2
1
REMOTE
5
EXT. CONT
COM
AUX-2 (IRIG-B)
IN
OUT
AUX-1 (DIGITAL)
IN
OUT
TRIG/REC
IN
VOLTAGE
AC FUSE
T4A
! SELECTOR
220V
RAL / HLD
9.6 / 19.2
TRG S/M
PTRG OFF/ON
% / dB
MST / SLV
IRIG ON / OFF
APD OFF / ON
(UP / DOWN)
SYNC
240V
DC IN
STAND BY
AC IN
DC BREAKER
XLR 32F
S
HR
CANNON
OPTION SLOT 2
D4
D3
D2
OPTION SLOT 1
D1
LSB DIGITAL
OUTPUT
8
7
6
5
4
3
2
1
ANALOG
OUTPUT
1
Monitor equipment
Analysis equipment
2
3
Select the tape speed with the SPD/BCM key. The selected SPD LED lights.
4
The tape speed during recording appears in the SPEED area, and the tape position
information appears in the tape position display area of the LCD screen.
5
The input setting and recording tape speed set during recording is also played back
simultaneously. This makes it easy to check the conditions set during recording.
Insert a pre-recorded tape into the recorder and press the FWD key. The recorder enters
the FWD (playback) mode and the data on the tape is played back.
2
5 4
POWER
BATT
SPD/BCM
dB
Advanced
Intelligent
Tape
%
OVR 1 1/2 1/4 1/8 1/16 1 2
SPD
AUX
–6
MONI
3
REW
FF EOD
FWD
STOP
(CH)
CAUTION
REC
OVR
PAUSE
CH
RANGE
RANGE
SPEED
CH
V X1/
S- TIME
ADDRESS REMAIN T - T I M E
Y
M
D
H
M
S
0
-40 -100
BOD
ID
M
-20
LOADING
EJECT
EXT TC
EXP SYN
OVR
+2
+100
0
1-4 5-8
S I R -1000W
M
A
OUT/TSG
ID/UTL
MRK/SLF
(UNIT)
SHIFT
PNL LOK
9-12 13-16
PK-CLR
OFFSET
A
SEARCH
DATA
ALL CH SELECT
LOAD
CLOCK
VOL
PHONE
MIC
ANN/P-SV
INSTRUMENTATION DIGITAL DATA RECORDER
ANALOG
INPUT
≤ ± 100vpk
1
2
3
100k
4
5
6
7
8
LSB DIGITAL
INPUT
≤ ± 10vpk 10k
D1
D2
D3
D4
ANALOG
MONITOR
REF
! CAUTION
• Noise may be generated if data between recording blocks is played back.
• Data recorded by SIR-1000/1000i cannot be played back.
• It takes max. 2 seconds from the start of playback when to set input setting the same as
the settings recorded on tape.
5-12
FWD-PAUSE (playback pause) Mode
To select the FWD-PAUSE (playback pause) mode, press the PAUSE key during the
STOP mode.
In the FWD-PAUSE mode, the data from where playback started is first read from the tape
(pre-reading) and stored in the FIFO memory, so the data is output on the instant the FWDPAUSE mode is released.
This mode is used to output the played back data simultaneously with the start of playback.
Note
When STOP key is pressed during the FWD-PAUSE mode, the data in the FIFO memory
stored by pre-reading will be cleared. The display shows the updated tape address where
the tape is actually located.
Monitor
The analog data signal during playback can be monitored.
1
2
Connect a BNC cable (sold separately) to the ANALOG MONITOR connector.
Press the ; or : key to select the monitor channel.
! CAUTION
The signal output from the ANALOG MONITOR connector can not be used for data analysis
because its characteristics differ from the output of each ANALOG OUTPUT connector.
Switching the Output Level (Analog channel)
To select the OUT (output level setting) mode, press the OUT/TSG key. The output level of
the analog main channel (channels 1 to 8) can be switched, as follows:
SPD/BCM
(CH)
RANGE
OFFSET
M
A
M
A
SEARCH
OUT/TSG
(UNIT)
ID/UTL
MRK/SLF
SHIFT
OUT/TSG key
PNL LOK
DATA
VOL
PHONE
MIC
ANN/P-SV
8 key
→
9 key
→
→
←
←
←
OUT display
1
2
5
––
Output level
±1 Vpk
±2 Vpk
±5 Vpk
manual
When manual (continuous variable) is selected, use the precision screwdriver (supplied) to
rotate the output level adjustment potentiometers on the rear panel so as to adjust the output
level ±0.5 to ±5 Vpk for each channel. Turning the potentiometer clockwise, the output voltage
increase up to ±5 Vpk.
5-13
Time Axis Conversion Playback
The SIR-1000W is capable of playing back data at different tape speeds from when the
data was recorded. Slow playback or fast playback is achieved by converting the
frequency of the recorded signal using the ratio of the tape speed during recording to the
tape speed during playback. This feature is especially useful when high speed signals need
to be displayed on a slow speed device such as chart recorders. The tape speed during
recording is displayed in the SPEED display area in the LCD screen.
Note
When a tape recorded at the tape speed slower than the normal speed is played back at the
normal speed, the playback signal may be interrupted momentarily. (In these cases, the mark
appears.) This may be due to various reasons, such as a large number of errors during
recording, or because real-time playback cannot be performed at the normal speed due to a
larger amount of retry data (useless data) than normal remaining on the tape, etc. Note that the
data not successfully reproduced at normal speed could be successfully reproduced at 1/2
speed or slower.
5-14
6 Recording and Playback Voice Annotations
The SIR-1000W can record and play back voice annotations along with analog data
signals simultaneously.
Bandwidths for the voice channels are as follows:
Tape Speed
Bandwidth
1 (normal speed)
0.2 to 19.2 kHz
1/2
0.2 to 9.6 kHz
1/4
0.2 to 4.8 kHz
1/8
0.2 to 2.4 kHz
1/16
0.2 to 1.2 kHz
Note that the SIR-1000W’s speaker has frequency response of 0.2 to 5 kHz.
! CAUTION
The signal output from the voice channel can not be used for data analysis because it is
prepared for voice annotations.
Connecting the Microphone and Earphone
1
2
Connect the microphone (supplied) to the MIC jack on the front panel.
Connect the earphone (sold separately) to the PHONE jack on the front panel.
POWER
BATT
SPD/BCM
dB
Advanced
Intelligent
Tape
%
OVR 1 1/2 1/4 1/8 1/16 1 2
SPD
AUX
–6
MONI
REW
FF EOD
FWD
STOP
(CH)
CAUTION
REC
OVR
PAUSE
CH
RANGE
RANGE
SPEED
CH
V X1/
S- TIME
ADDRESS REMAIN T - T I M E
Y
M
D
H
M
S
0
-40 -100
BOD
ID
M
-20
LOADING
EJECT
EXT TC
EXP SYN
OVR
+2
+100
0
1-4 5-8
S I R -1000W
M
A
OUT/TSG
ID/UTL
MRK/SLF
(UNIT)
SHIFT
PNL LOK
9-12 13-16
PK-CLR
OFFSET
A
SEARCH
DATA
ALL CH SELECT
LOAD
CLOCK
VOL
PHONE
MIC
ANN/P-SV
Microphone
INSTRUMENTATION DIGITAL DATA RECORDER
ANALOG
INPUT
≤ ± 100vpk
1
2
3
100k
4
5
6
7
8
LSB DIGITAL
INPUT
≤ ± 10vpk 10k
D1
D2
D3
D4
ANALOG
MONITOR
REF
Earphone
6-1
Recording Voice Annotations
1
When the switch on the left side of the microphone is pressed, this function is ON, and
when released it goes OFF. This makes it possible to record only the necessary sounds.
2
The brightness of the MIC (Microphone) LED varies according to the microphone
input level.
Note
1. The recording level can be adjusted automatically with the recorder’s AGC function.
2. Sound cannot be output from the speaker in the REC mode or while the earphone is
being used.
Playback Voice Annotations
• When the ANN/P-SV key is pressed so that the ANN LED lights, voice annotations
recorded on the tape can be played back through the speaker (or the earphone when the
PHONE jack is used). Adjust the volume with the VOL knob.
Note
• When the ANN/P-SV key is pressed so that the DATA LED lights, the monitor
channel’s data signal is played back as sound from the speaker or the earphone.
• When the tape speed during recording and playback differ, the pitch (signal frequency)
of voice annotations differs from the original one.
• The existence of voice annotations can be checked by the light of MIC LED while the
VOL knob is in the minimum position.
6-2
7 Recording and Playback AUX Digital Data
The SIR-1000W can record and play back AUX digital data signals and analog data
signals simultaneously.
The rotating pulse and trigger pulse can be recorded and played back as the AUX digital
data signal.
• Internal sampling frequencies for the AUX digital channels are as follows.
Tape Speed
Sampling frequency
Ts (approx)
1 (normal speed)
384 kHz
6 µs
1/2
192 kHz
12 µs
1/4
96 kHz
25 µs
1/8
48 kHz
50 µs
1/16
24 kHz
100 µs
Table 7-1
When make a recording on the AUX digital channel, the signal should conform to the
following conditions:
Ts
Tr
Ts
Tf
: Minimum hold time
(See Table 7-1.)
Tr/Tf : Level transition time
(100 µs regardless of tape
speed)
Ts
• Attention should be paid to selecting the sampling rate in order to avoid the jitter inherent
in discrete sampling.
Input
fi
d1
d2
d3
d4
Int Clock
fs
Output
fo
fi
fs
fo
d1 to d4
:
:
:
:
Input Waveform
Sampling Waveform (Internal Clock)
Output Waveform
Phase-shift
Example of phase shift caused by sampling
7-1
Connecting the AUX Digital Data
Use a BNC cable (sold separately) to connect the AUX-1 (DIGITAL) IN connector on the
rear panel and the signal source.
If necessary, use a BNC cable to connect monitoring equipment to the AUX-1 (DIGITAL)
OUT connector on the rear panel.
When AUX digital data is input (high and low occur repeatedly within a set interval), the
AUX-1 LED in the display lights indicating the input signal is being fed in the E-E, RECPAUSE or REC mode. If the LED does not light, check the cable connections.
9
8
25
6
7
24
21
22
23
19
20
18
17
16
15
14
1
4
3
2
13
12
COM
11
10
9
8
7
AUX-2 (IRIG-B)
IN
OUT
! SELECTOR
!
220V
5
6
5
4
3
2
1
REMOTE
VOLTAGE
AC FUSE
T4A
8 7 6 5 4 3 2 1
EXT. CONT
SYNC
AUX-1 (DIGITAL)
IN
OUT
TRIG/REC
IN
% / dB
MST / SLV
IRIG ON / OFF
APD OFF / ON
(UP / DOWN)
RAL / HLD
9.6 / 19.2
TRG S/M
PTRG OFF/ON
240V
DC IN
STAND BY
AC IN
DC BREAKER
XLR 32F
S
HR
CANNON
OPTION SLOT 2
D4
D3
D2
OPTION SLOT 1
D1
LSB DIGITAL
OUTPUT
8
7
6
5
4
3
2
1
ANALOG
OUTPUT
Signal source
Monitor equipment
! CAUTION
• Do not input simultaneously a signal with a different ground level than those of the
analog data signals.
• The input/output level is TTL.
Recording AUX Digital Data Signals
When recording starts, the AUX digital data signal input to the AUX digital channel is
recorded on the tape simultaneously along the main data signals.
The AUX-1 LED above the LCD screen lights when the input signal is detected.
Playback AUX Digital Data Signals
When playing back a tape on which an AUX digital data signal has been recorded, the
AUX digital data signal is output from the AUX-1 (DIGITAL) OUT connector on the rear
panel.
The AUX-1 LED above the LCD screen lights when the playback signal is detected.
7-2
8 Recording and Playback AUX Analog Data
In addition to the main analog channels (8 channels when the recorder is used alone), the SIR1000W is also equipped with AUX-2 (IRIG-B) channels as a sub-analog channel. AUX
analog data signal can be recorded and played back simultaneously along main analog data
signals.
The bandwidths for the AUX analog channel is as follows:
Tape speed
Bandwidth
1 (normal speed)
DC to 19.2 kHz
1/2
DC to 9.6 kHz
1/4
DC to 4.8 kHz
1/8
DC to 2.4 kHz
1/16
DC to 1.2 kHz
Either an ordinary analog signal or an IRIG-B format time code signal can also be used
as AUX analog data signal.
8-1
8-1 Recording and Playback IRIG-B Time Code Signal
Connecting a IRIG-B Time Code Signal
The following IRIG-B time code signal can be connected.
Code
: Amplitude modulation code (AC code)
Carrier frequency
: 1 kHz
Voltage range
: ±1 to ±10 Vpk
Modulation amplitude ratio : 1:3
8 7 6 5 4 3 2 1
IRIG ON/OFF
9
8
25
6
7
24
21
22
23
19
20
18
17
16
15
14
1
4
3
2
13
12
11
10
9
8
7
AUX-2 (IRIG-B)
IN
OUT
SYNC
AUX-1 (DIGITAL)
IN
OUT
TRIG/REC
IN
! SELECTOR
!
5
6
5
4
3
2
1
REMOTE
COM
VOLTAGE
AC FUSE
T4A
8 7 6 5 4 3 2 1
EXT. CONT
220V
RAL / HLD
9.6 / 19.2
TRG S/M
PTRG OFF/ON
% / dB
MST / SLV
IRIG ON / OFF
APD OFF / ON
(UP / DOWN)
240V
DC IN
STAND BY
AC IN
DC BREAKER
XLR 32F
S
HR
CANNON
OPTION SLOT 2
D4
D3
D2
OPTION SLOT 1
D1
LSB DIGITAL
OUTPUT
8
7
6
5
4
3
2
1
ANALOG
OUTPUT
Time code generator
Time code reader
1
Set the digital switch IRIG ON/OFF on the rear panel to the ON (upper/factory setting
position).
2
Use a BNC cable (sold separately) to connect the AUX-2 (IRIG-B) IN connector on
the rear panel and the IRIG-B time code signal from an IRIG time code generator.
If necessary, use a BNC cable (sold separately) to connect the AUX-2 (IRIG-B) OUT
connector on the rear panel and IRIG time code reader.
! CAUTION
If the digital switch IRIG ON/OFF is set to OFF, the IRIG-B time code signal cannot be
detected properly.
8-2
Recording IRIG-B Time Code Signal
When an IRIG-B time code signal is input to the recorder in the E-E, REC-PAUSE or REC
mode, the EXT LED light. And “001” to be displayed and start blinking.
IRIG-B time code is loaded to the recorder’s realtime clock when IRIG-B time code is
synchronized to the recorder’s realtime clock.
When recording starts, the IRIG-B time code signal input to the AUX analog channel is
recorded on the tape along with the main data.
Also, the recorder’s realtime clock to which the IRIG time has been loaded changes to the
S-TIME (xxYxxMxxD/xxHxxMxxS), and is recorded on the tape along with the main
data. This information can be used as accurate position data for search, playback and data
transfer.
Note
• When the IRIG-B time code signal is detected by the recorder, it takes a maximum of
5 seconds for the AUX2 LED to light.
As the sync of this signal is a cycle per minute, it takes one minute at maximum for the
EXT TC LED to light up.
• Being properly detected, the 3-digit date (001 to 366) of the IRIG-B time code data is
converted to “-YxxMxxD” (normal year) and combined with the year value “xxY” of
the recorder’s realtime clock at the time or recording to form the S-TIME information
(xxYxxMxxD).
• When the IRIG time has been loaded to the realtime clock, the clock proceeds at crystal
accuracy when the IRIG-B time code signal is removed.
• When being input a signal, AUX2 outputs regardless of E-E or STOP mode.
Playback IRIG-B Time Code Signal
When a tape recorded with a IRIG-B time code signal in the AUX-2 (IRIG) channel is
played back, the EXT TC LED lights.
Further, the raw IRIG-B time code signal recorded on the tape can be output from the
AUX-2 (IRIG-B) OUT connector on the rear panel, and can be read by an IRIG time code
reader.
For the T-TIME information in the tape position display area during playback, the
recorder’s realtime clock value (xxYxxMxxD/xxHxxMxxS) recorded on the tape is
displayed. This value corresponds to the IRIG time recorded on the tape.
8-3
8-2 Recording and Playback AUX Analog Data
Connecting the AUX Analog Signals (general purpose)
8 7 6 5 4 3 2 1
IRIG ON/OFF
8 7 6 5 4 3 2 1
!
9
8
25
6
7
24
21
22
23
19
20
18
17
16
15
14
1
5
4
3
2
13
12
11
10
9
8
7
6
5
4
3
2
1
EXT. CONT
REMOTE
COM
AUX-2 (IRIG-B)
IN
OUT
SYNC
AUX-1 (DIGITAL)
IN
OUT
TRIG/REC
IN
% / dB
MST / SLV
IRIG ON / OFF
APD OFF / ON
(UP / DOWN)
VOLTAGE
AC FUSE
T4A
! SELECTOR
220V
RAL / HLD
9.6 / 19.2
TRG S/M
PTRG OFF/ON
240V
DC IN
STAND BY
AC IN
DC BREAKER
XLR 32F
RS
H
CANNON
OPTION SLOT 2
D4
D3
D2
OPTION SLOT 1
D1
LSB DIGITAL
OUTPUT
8
7
6
5
4
3
2
1
ANALOG
OUTPUT
Analog signal source
Monitor equipment
1
2
Set the digital switch IRIG ON/OFF on the rear panel to the OFF (lower position).
Use a BNC cable (sold separately) to connect the AUX-2 (IRIG-B) IN connector on
the rear panel and the AUX analog data signal from the AUX analog signal source.
If necessary, use a BNC cable (sold separately) to connect monitoring equipment to the
AUX-2 (IRIG-B) OUT connector on the rear panel.
When the AUX analog data signal is input, the AUX-2 LED lights. If the LED does
not light, check the cable connections.
!
CAUTION
• If the digital switch IRIG ON/OFF is set to ON, AGC is applied to the AUX analog input signal.
• The rated input level of AUX analog data signals is ±2 Vpk.
The maximum input level is approximately ±3Vpk.
Recording AUX Analog Data Signal
When recording starts, the AUX analog data signal input to the AUX analog channel can
be recorded on the tape simultaneously along the main data signals.
Playing Back AUX Analog Data Signal
When a tape recorded with an AUX analog data signal is played back, the AUX analog
data signal is output from the AUX-2 (IRIG-B) OUT connector on the rear panel.
8-4
9 Trigger Recording
Connecting the Trigger Signal
1
Set the digital switch TRG S/M on the rear panel to S or M according to the purpose.
When this switch is set to the S (upper position) with the recorder is in REC-PAUSE
mode, recording starts when the trigger input signal goes from high to low and
continues until the STOP key is pressed. When set to the M (lower position), recording
starts when the trigger input signal goes low, and when the signal goes high the recorder
becomes REC pause.
2
Use a BNC cable (sold separately) to connect the TRIG IN connector on the rear panel
and the trigger signal source.
8 7 6 5 4 3 2 1
TRG S/M
PTRG OFF/ON
9
8
25
6
7
24
21
22
23
19
20
18
17
16
15
14
1
4
3
2
13
12
COM
11
10
9
8
7
AUX-2 (IRIG-B)
IN
OUT
! SELECTOR
!
220V
5
6
5
4
3
2
1
REMOTE
VOLTAGE
AC FUSE
T4A
8 7 6 5 4 3 2 1
EXT. CONT
SYNC
AUX-1 (DIGITAL)
IN
OUT
TRIG/REC
IN
% / dB
MST / SLV
IRIG ON / OFF
APD OFF / ON
(UP / DOWN)
RAL / HLD
9.6 / 19.2
TRG S/M
PTRG OFF/ON
240V
DC IN
STAND BY
AC IN
DC BREAKER
XLR 32F
S
HR
CANNON
OPTION SLOT 2
D4
D3
D2
OPTION SLOT 1
D1
LSB DIGITAL
OUTPUT
ANALOG
8
7
6
5
4
3
2
1 OUTPUT
Signal source
! CAUTION
In the ADDRESS duration is less than 2 seconds, the next recording may not start up.
Note
The input voltage level should be TTL level.
9-1
Trigger Recording
When the recorder is being set to the REC-PAUSE mode, the recorder starts to record
when the trigger signal is received from the trigger signal source, or the REC-PAUSE
mode is released by pressing the PAUSE key.
In the case of the pre-trigger mode (PTRG OFF/ON is ON), the pre-trigger time (the data
length before the trigger) is set to 3 seconds, 6 seconds, 12 seconds, 24 seconds or 48
seconds depending on the tape speeds. In the case of the normal trigger mode (PTRG OFF/
ON is OFF), the data immediately after the trigger is recorded, i.e. pre-trigger time is zero.
Note
If the REC mode is started form the REC-PAUSE mode in less than the pre-trigger time
(3 seconds at the normal speed, 6 seconds at 1/2 speed and so on), all the pre-trigger data
may not be recorded. The pre-trigger data start to be written to the FIFO memory when
the REC-PAUSE mode is executed. It takes the pre-trigger time to hold all the pre-trigger
data in the FIFO memory.
Playback of the Pre-trigger Data
When the recorder is set to the FWD mode, the pre-trigger data is played back with the
ADDRESS “–00H00M00S”.
9-2
10 Search
The target data on the tape can be quickly accessed using the search function. The recorder
can use the following types of search:
Search Type
Control
Front panel
Remote control unit
Host computer
ID
Yes
Yes
No
ID number
Yes
No
Yes
Start ID
Yes
No
Yes
EOD
Yes
Yes
Yes
MRK (Mark)
Yes
No
No
Address
No
No
Yes
Realtime clock
No
No
Yes
The LED display is as follows during the ID number search and MRK search modes:
LED
Search Operation
SEARCH
ID number
MRK/SLF
SEARCH key pressed
Lit
Blinking
Blinking
Searching
Blinking
FOUND (ends normally)
LED of selected mode lit
Off
NOT FOUND (target not found)
Off
Blinking
Off
LED of selected mode blinks
Press the STOP key to cancel the search.
Note
When TOC data cannot be used (see section 2-2), “TOC?” is displayed if an attempt is
made to start search operation. Press the FF key to read the TOC data, and then perform
the search again.
ID Search
If the FF key or REW key is pressed during playback (FWD), the start of the next ID or
the current ID is searched and then playback starts from that point.
POWER
BATT
SPD/BCM
dB
Advanced
Intelligent
Tape
%
OVR 1 1/2 1/4 1/8 1/16 1 2
SPD
AUX
–6
MONI
REW
FF EOD
FWD
STOP
(CH)
CAUTION
REC
OVR
PAUSE
CH
REW key
RANGE
RANGE
SPEED
CH
V X1/
S- TIME
ADDRESS REMAIN T - T I M E
Y
M
D
H
M
S
0
-40 -100
BOD
ID
M
-20
LOADING
EJECT
EXT TC
EXP SYN
OVR
+2
+100
0
1-4 5-8
S I R -1000W
M
A
OUT/TSG
ID/UTL
MRK/SLF
(UNIT)
SHIFT
PNL LOK
9-12 13-16
PK-CLR
OFFSET
A
SEARCH
DATA
ALL CH SELECT
LOAD
CLOCK
VOL
PHONE
MIC
ANN/P-SV
INSTRUMENTATION DIGITAL DATA RECORDER
FF key
STOP key
ANALOG
INPUT
≤ ± 100vpk
1
2
3
100k
4
5
6
7
8
LSB DIGITAL
INPUT
≤ ± 10vpk 10k
D1
D2
D3
D4
ANALOG
MONITOR
REF
Example:
If the FF key is pressed during playback of ID “100” data, the start of the next ID (normally
“101”) is searched and then playback starts from that point. If the REW key is pressed
instead, the start of the current ID (“100”) is searched and then playback starts.
10-1
ID Number Search
This function searches for the start point of the target ID number.
1
SPD/BCM
(CH)
RANGE
OFFSET
M
A
M
2
A
SEARCH
OUT/TSG
(UNIT)
ID/UTL
MRK/SLF
SHIFT
1, 3
PNL LOK
DATA
VOL
PHONE
MIC
ANN/P-SV
1
2
3
To select the ID search mode, press the SEARCH key and then the ID key.
Press the ;, :, 8 or 9 key to set the target’s ID number.
Press the ID key again; the target ID is searched, and then the search operation ends.
Start ID Search
The start IDs located at the starting point of each recording can be searched.
• To skip to and stop at the starting point of the next recording from the current position,
press the SEARCH key and then the FF key.
• To return to and stop at the starting point of the current recording, press the SEARCH
key and then the REW key.
SEARCH key
POWER
BATT
SPD/BCM
dB
Advanced
Intelligent
Tape
%
OVR 1 1/2 1/4 1/8 1/16 1 2
SPD
AUX
–6
MONI
REW
FF EOD
FWD
STOP
(CH)
CAUTION
REC
OVR
PAUSE
CH
REW key
RANGE
RANGE
SPEED
CH
V X1/
S- TIME
ADDRESS REMAIN T - T I M E
Y
M
D
H
M
S
0
-40 -100
BOD
ID
M
-20
LOADING
EJECT
EXT TC
EXP SYN
OVR
+2
+100
0
1-4 5-8
S I R -1000W
M
A
OUT/TSG
ID/UTL
MRK/SLF
(UNIT)
SHIFT
PNL LOK
9-12 13-16
PK-CLR
OFFSET
A
SEARCH
DATA
ALL CH SELECT
LOAD
CLOCK
VOL
PHONE
MIC
ANN/P-SV
INSTRUMENTATION DIGITAL DATA RECORDER
FF key
ANALOG
INPUT
≤ ± 100vpk
1
REF
10-2
2
3
100k
4
5
6
7
8
LSB DIGITAL
INPUT
≤ ± 10vpk 10k
D1
D2
D3
D4
ANALOG
MONITOR
EOD Search
This function searches for the EOD. This is convenient when starting to record new data
from the end of the last recording block. Press the FF key to start EOD search, the tape
stops at the EOD and the EOD LED lights.
POWER
BATT
Advanced
Intelligent
Tape
LOADING
EJECT
BOD
REW
FF EOD
FWD
STOP
REC
PAUSE
EOD LED
FF key
MRK (Mark) Search
Pressing the MRK/SLF key at any tape position, allows that position to be searched later.
SPD/BCM
(CH)
RANGE
M
OFFSET
A
M
A
SEARCH
OUT/TSG
(UNIT)
ID/UTL
MRK/SLF
SHIFT
PNL LOK
DATA
VOL
PHONE
MIC
2
1, 2
ANN/P-SV
1
When the MRK/SLF key is pressed in the REC or FWD mode, the tape position
information for that location is stored in the recorder’s memory, and is held until the
next time the MRK/SLF key is pressed.
2
To select the mark search mode, press the SEARCH key and then the MRK/SLF key.
The target is searched and the search operation ends.
Note
• Each time the MRK/SLF key is pressed the tape position information is updated.
• When using a slow tape speed (1/4, 1/8, 1/16), the marked point may be offset from
the target by a maximum of 3 seconds in the realtime clock value.
10-3
Address Search
This function searches target by the tape address value. It is controlled from the host
computer by RS-232C commands.
Realtime Clock Search
This function searches target by the realtime clock value recorded on the tape. It is
controlled from the host computer by RS-232C commands.
10-4
11 External Control
The SIR-1000W can be operated easily by using a TTL level control signal via the
EXT.CONT connector.
Functions
Command functions (input)
The following commands can be input to the recorder.
• Tape transport mode setting
• ID increment
Monitoring functions (output)
The following recorder states can be output.
• Loading
• Tape transport mode
• Alarm message
• BOD, EOD, EOT
Interface
14
1
25
13
Connector : Square, D-sub 25-pin
Input
: TTL level, pulse width of 100 ms or more, input by shorting pins 1 or 15 (GND)
Output
: TTL level output, sink current maximum 20 mA
Connector Pin Assignment
Pin No. Signal name
Function
I/O Pin No. Signal name
Function
I/O
—
14
+5V
AUXILIARY POWER SUPPLY O
15
GND
GND
—
O
16
RSV
RESERVED
—
EOD
O
17
RSV
RESERVED
—
ALARM
ALARM MESSAGE
O
18
RSV
RESERVED
—
6
EOT
EOT
O
19
IDINC
ID INCREMENT
I
7
LOADING
LOADING
O
20
IPAUSE
PAUSE
I
8
OPAUSE
PAUSE
O
21
IREC
REC
I
9
OREC
REC
O
22
ISTOP
STOP
I
10
OSTOP
STOP
O
23
IFWD
FWD
I
11
OFWD
FWD
O
24
IFF
FF
I
12
OFF
FF
O
25
IREW
REW
I
13
OREW
REW
O
GND
1
GND
2
+5V
3
BOD
BOD
4
EOD
5
AUXILIARY POWER SUPPLY O
Note
ALARM : Output when any one of low DC voltage, recording/playback error, dew
condensation or mechanical malfunction occurs.
+5V
: Used for lighting external LEDs. 100 mA maximum for pins 2 and 14 together.
11-1
Input/output interface circuit
SIR-1000W
10 kΩ
15 Ω
EXT. CONT. Connector
15 Ω
Input/output logic
High level
Low level
Pulse width
11-2
IN
47 pF
M6650
M6650
15 Ω
15 Ω
47 pF
: Negative
: +3.5 V or more 
 Voltage at the EXT. CONT connector
: +1.5 V or more 
: 100 ms or more
OUT
12 RS-232C Control
The COM connector (D-sub 9-pin) on the rear panel of the recorder conforms to the RS232C signal format. Thus, the recorder can be controlled from a host computer by
connecting an RS-232C cable (commercially available) to the COM connector.
! CAUTION
• Use a shielded RS-232C cable.
When the recorder is controlled via RS-232C, it is recommended to monitor the status
of the recorder by using the commands such as ERR? or ALM?.
• Data will not be recorded for the first one second after the REC command via RS-232C.
12-1 Interface Specifications
9
5
6
1
Signal format
Connector
Bit rate
Character length
Parity bit
Stop bit
Flow control
: EIA RS-232C protocol
: Square, D-sub 9-pin
: 9.6, 19.2 kbps (switchable), asynchronous
: 8 bits
: None
: 1 bit
: CTS/RTS - Hardware flow control
Connector Pin Assignment
Pin No.
Signal name
Function
I/O
1
RSV
RESERVED
—
2
RD
RECEIVE DATA
I
3
TD
TRANSMIT DATA
O
4
RSV
RESERVED
—
5
GND
GND
—
6
RSV
RESERVED
—
7
RTS
TRANSMIT REQUEST
O
8
CTS
TRANSMIT POSSIBLE
I
9
RSV
RESERVED
—
12-1
12-2 Command Overview
Setting Commands
The command, that can be output to the recorder from a host computer are as follows:
Function
Command
12-2
Comments
BAR :
Bar meter control
CAL :
Calibration
CHA :
Channel mode setting
FMT :
Tape formatting
IDS :
ID increment
INP :
Input format setting
SIR-1000i only
LCH :
LSB digital channel setting
SIR-1000W only
MEM :
Memo character string setting
MOD :
Tape transport mode setting
MON :
Monitor channel selection
OFS :
DC offset setting
OFA :
Auto offset setting
OPL :
Output level selection
PNL :
Panel lock
PSV :
Power-save
RNA :
Auto range setting
RNG :
Input range setting
RPT :
Auto repeat
SCH :
Search
SLF :
Self-check
SPD :
Tape speed setting
SPO :
Speaker source selection
TIM :
Real-time clock setting
TRG :
Trigger mode setting
TRM :
Terminator selection
TSG :
Test signal selection
UTL :
Utility mode setting
Only during stop
Status Commands
When a status request is received from a host computer, the recorder sends back the
following setting value or status contents:
Function
Command
Comments
ADR?
Tape ADDRESS
ALM?
Alarm status
AUX?
Front panel status
BAR?
Bar meter setting readout
BAT?
Battery status
CAL?
Calibration status
CHA?
Channel mode setting readout
CFG?
Recorder configuration
CMD?
Command check
ERR?
Error check
FMT?
Tape formatting execution status
IDS?
Tape ID number readout
INP?
Input format setting and reading
SIR-1000i only
LCH?
LSB digital channel read
SIR-1000W only
LVA?
Signal level read (text format)
LVB?
Signal level read (binary format)
MAP?
Slave ID read
MEM?
Memo character string readout
MOD?
Tape transport mode readout
MON?
Monitor channel setting readout
OFA?
Auto offset setting status
OFS?
DC offset value readout
OPL?
Output level setting readout
PNL?
Panel lock status readout
PSV?
Power-save status
RNA?
Auto range setting status readout
RNG?
Range setting value readout
RPT?
Auto repeat status readout
SCH?
Search status
SLF?
Self-check status
SPD?
Tape speed readout
SPO?
Speaker source selection status
STA?
Status A
TIM?
Real-time clock readout
TOC?
TOC data readout
TRG?
Trigger mode setting status
TRM?
Terminator selection status (returned strings)
TSG?
Test signal selection status
UTL?
Utility mode setting readout
VOL?
Tape volume readout
12-3
12-3 Command Details
Setting Commands
All commands use ASCII code. Each command ends with an LF (line feed), CR (carriage
return) or CR + LF.
< >: This is the command parameter, and represents one English character.
/[ ]: This enables commands to be specified for individual recorders when multiple
recorders are connected such as during synchronous operation. The / [ ] parameter
specifies any one ID number. This specification can be omitted when only one recorder
is connected or when the target is the recorder with ID = 0.
When performing synchronous operation with two recorders, the master is ID = 0 and the
slave is ID = 1.
Command
BAR :
Command format
Contents
Bar meter control
BAR : <1><2>/[ ]
<1>: 0 = Real-time mode, 1 = Peak hold mode
<2>: 0 = Unidirectional mode, 1 = Bidirectional mode
Ex.) BAR:01
BAR:11/1
— Real-time and bidirectional modes set.
— Peak hold and bidirectional modes set for recorders MASTER=0, SLAVE=1.
Related command: BAR?
CAL :
Command format
Calibration
CAL : <1>/[ ]
<1>: 0 = Calibration stop, 1 = Calibration start
The results can be viewed using the CAL? command.
Related command: CAL?
CHA :
Command format
Channel mode setting
CHA : <1><2>/[ ]
<1> :Analog channel code
<2> : Digital channel code
0=OFF
0=OFF
1=RSV
1=1ch (Async)
2=RSV
2=2ch (Async)
3=RSV
3=4ch (Async)
4=RSV
4=8ch (Async)
5=16ch (SIR-1000/1000i)
5=RSV
6=32ch (SIR-1000/1000i)
6=RSV
7=64ch (SIR-1000/1000i)
7=RSV
8=128ch (SIR-1000/1000i)
8=RSV
9=RSV
9=RSV
A=RSV
A=1ch (Sync)
B=2ch (SIR-1000W)
B=2ch (Sync)
C=4ch (SIR-1000W)
C=4ch (Sync)
D=8ch (SIR-1000W)
D=8ch (Sync)
E=16ch (SIR-1000W)
E=RSV
F=RSV
F=RSV
Note Analog and digital channel modes can be used together in only certain combinations. See the instruction manual of SBS-10A/S for a detailed description.
Set the digital channel code with DIP switch on the SBS-10A/S board.
Related command: CHA?
12-4
Command
Contents
FMT : (SIR-1000i only)
Command format
Tape formatting
FMT : <1><2><3><4>/[ ]
<1>: 0 = RSV, 1 = Formatting start
<2><3><4>: ID number at formatting (001 to 999)
Note This command logically erases all pre-recorded data.
Related command: FMT?
IDS :
Command format
ID increment
IDS : <1>
<1>: 0 = RSV, 1 = ID increment
The recorder ID is incremented each time the IDS:1 command is issued.
Related command: IDS?
INP : (SIR-1000/SIR-1000i only) Input format setting
Command format
INP : <1><2>...<17>/[ ]
<1>: Channel expansion unit ID number
0 = Recorder
1 = Channel expansion unit 1
2 = Channel expansion unit 2
3 = Channel expansion unit 3
4 = Channel expansion unit 4
5 = Channel expansion unit 5
6 = Channel expansion unit 6
7 = Channel expansion unit 7
<2>: Input format for CH1
0 = DIRECT
1 = SENSOR
<3>: Input format for CH2
.
.
.
<17>: Input format for CH16
Related command: INP?
LCH : (SIR-1000W only)
Command format
LSB digital channel setting
LCH : <1>/[ ]
<1>: 0 = OFF
1 = 1ch
2 = 2ch
3 = 4ch
Note
Related command: LCH?
MEM :
Command format
Annotation character string setting
MEM : <1><2>...<96>/[ ]
<1><2>...<96>: ASCII characters (20h to FFhex) up to maximum 96 characters
Ex.) MEM:MEASUREMENT-1 — (Annotation character string “MEASUREMENT-1” set.)
Related command: MEM?
MOD :
Command format
Tape transport mode setting
MOD : <1>/[ ]
<1>: 0 = STOP, 1 = FWD, 2 = E-E, 3 = REC, 4 = FWD-PAUSE, 5 = REC-PAUSE, 6 = FF,
7 = RSV, 8 = REW, 9 = RSV, A = EJECT
Ex.) MOD:1 — FWD mode
Related command: MOD?
12-5
Command
MON :
Command format
Contents
Monitor channel selection
MON : <1><2>/[ ]
<1>: Channel expansion unit ID number <2>: Channel code
0 = Recorder
0 = CH 1
1 = Channel expansion unit 1
1 = CH 2
2 = Channel expansion unit 2
2 = CH 3
3 = Channel expansion unit 3
3 = CH 4
4 = Channel expansion unit 4
4 = CH 5
5 = Channel expansion unit 5
5 = CH 6
6 = Channel expansion unit 6
6 = CH 7
7 = Channel expansion unit 7
7 = CH 8
8 = CH 9
9 = CH 10
A = CH 11
B = CH 12
C = CH 13
D = CH 14
E = CH 15
F = CH 16
Related command: MON?
OFA :
Command format
Auto offset setting
OFA : <1><2>/[ ]
<1>: RSV (always 0)
<2>: 0 = DC offset measurement stop and set, 1 = Offset measurement start
Related command: OFA?
OFS :
Command format
DC offset setting
OFS : <1><2>...<33>/[ ]
<1>: Channel expansion unit ID number (0=Recorder)
<2><3>: CH 1 DC offset
<4><5>: CH 2 DC offset
.
.
.
<32><33>: CH 16 DC offset
The DC offset value is expressed as a 2-digit hexadecimal number.
Ex.) OFS : 000100022334500FFCE2345220034A1FB
00 : 0%
01 : 1%
10 : 16%
32 : 50%
64 : 100%
FF : –1%
CE : –50%
9C : –100%
Related command: OFS?
12-6
Command
OPL :
Command format
Contents
Output level selection
OPL : <1><2>...<17>
<1>: Channel expansion unit ID number (0=Recorder)
<2>: CH 1 output level code
<3>: CH 2 output level code
.
.
.
<17>: CH 16 output level code
Output level code
0 = RSV, 1 = RSV, 2 = 5 V, 3 = 2 V, 4 = 1 V, 5 = RSV, 6 = RSV, 7 = RSV, 8 = RSV, 9 = RSV,
A = Manual
Related command: OPL?
PNL :
Command format
Panel lock
PNL : <1>/[ ]
<1>: 0 = Panel lock canceled, 1 = Panel lock set
Related command: PNL?
PSV :
Command format
Power-save
PSV : <1>/[ ]
<1>: 0 = Power-save canceled, 1 = Power-save set
Related command: PSV?
RNA :
Command format
Auto range setting
RGA : <1><2>/[ ]
<1>: RSV (always 0)
<2>: 0 = Range measurement stop and set, 1 = Range measurement start
Related command: RNA?
RNG :
Command format
Input range setting
RNG : <1><2>...<17>/[ ]
<1>: Channel expansion unit ID number
0 = Recorder
1 = Channel expansion unit 1
2 = Channel expansion unit 2
3 = Channel expansion unit 3
4 = Channel expansion unit 4
5 = Channel expansion unit 5
6 = Channel expansion unit 6
7 = Channel expansion unit 7
<2>: CH 1 input range code
<3>: CH 2 input range code
.
.
.
<17>: CH 16 input range code
Input range code
0 = 20 V, 1 = 10 V, 2 = 5 V, 3 = 2 V, 4 = 1 V, 5 = 0.5 V, 6 = 0.2 V, 7 = 0.1 V
Related command: RNG?
RPT :
Command format
Auto repeat
RPT : <1>/[ ]
<1>: 0 = Auto repeat stop, 1 = Auto repeat start
Related command: RPT?
12-7
Command
SCH :
Command format
Contents
Search
SCH : <1><2>...<N>/[ ]
ID number search
<1> : 0
<2><3><4>: 001 to 999 or 000
Real-time clock search
<1> : 1
<2><3>...<13>: YYMMDDhhmmss
Address search
<1> : 2
<2><3>...<7>: hhmmss
Start ID search
<1> : 3
<2> : 0 = Forward, 1 = Backward
BOD/EOD search
<1> : 4
<2> : 0 = EOD, 1 = BOD
Ex.) SCH:0100
— Target: ID = 100
SCH:1970506120000 — Target: 1997, May 6, 12:00:00
Related command: SCH?
SLF :
Command format
Self-check
SLF : <1>/[ ]
<1>: 0 = Self-check stop, 1 = Self-check start
Related command: SLF?
SPD :
Command format
Tape speed setting
SPD : <1>
<1>: 0 = 1 × (normal speed), 1 = 1/2 ×, 2 = 1/4 ×, 3 = 1/8 ×, 4 = 1/16 ×, F = EXT
Related command: SPD?
SPO :
Command format
Speaker source selection
SPO : <1>/[ ]
<1>: 0 = Voice channel, 1 = Monitor selected data channel
Related command: SPO?
TIM :
Command format
Real-time clock setting
TIM : <1><2>...<12>
<1><2>: Year (last 2 digits)
<3><4><5><6>: Month and date
<7><8><9><10><11><12>: Hours, minutes and seconds
Related command: TIM?
TRG :
Command format
Trigger mode setting
TRG : <1>
<1>: 0 = RSV
1 = Pre-trigger single mode (low: start)
2 = Pre-trigger multi mode (low: start, high: stop)
3 = Normal single mode (low: start)
4 = Normal multi mode (low: start, high: stop)
Related command: TRG?
TRM :
Command format
Terminator selection
TRM : <1>
<1>: 0 = (CR + LF), 1 = CR, 2 = LF
This sets the break code for replies from the recorder. The default is (CR + LF).
Related command: TRM?
12-8
Command
TSG :
Command format
Contents
Test signal selection
TSG : <1>/[ ]
<1>: Test signal selection
Analog channel
Digital channel
0=
OFF
OFF
1=
AC
010000000000000001000..
2=
+DC
110000000000000000111..
3=
–DC
010000000100000001000..
4=
GND
000000000000000000000..
5=
EXT
010101010101010101010..
Related command: TSG?
UTL:
Command format
Utility mode setting
UTL : <1><2><3>/[ ]
<1>: 0= AT FMT OFF
1= AT FMT ON
<2>: 0= ERA OFF
1= ERA ON
<3>: 0 = DEW OFF
1 = DEW ON
<4>: 0= BOT EJCT OFF
1= BOT EJCT ON
<5>: 0= SKP ET03 OFF
1= SKP ET03 ON
<6>: 0 = CMP MODE OFF
1 = CMP MODE ON
Related command: UTL?
12-9
Status Commands
Status commands are used to request status information from the recorder. When the
recorder receives a status command, it sends the corresponding status information.
Note
The /[ ] parameter specifies any one ID number, and can be omitted when only one
recorder is connected or when the target is the recorder with ID = 0. When performing
synchronous operation, the master is ID = 0 and the slave is ID = 1.
Command
ADR?
Command format
Returned format
Contents
Tape ADDRESS
ADR?/[ ]
ADR:<1><2><3><4><5><6><7><8><9><10>
Tape ADDRESS
<1><2>: hh (hour)
<3><4>: mm (minutes)
<5><6>: ss (seconds)
Remain
<7><8>: hh (hour)
<9><10>: mm (minutes)
Ex.) ADR? (current tape ADDRESS requested)
ADR?/1 (current tape ADDRESS for recorder with ID = 1 requested)
ALM?
Command format
Returned format
Alarm status
ALM?/[ ]
ALM:<1><2><3><4>
<1>: 0 = Normal, 1 = Power supply voltage drop
<2>: 0 = Normal, 1 = Condensation
<3>: 0 = Normal, 1 = Recording/playback error (buffer over/underflow)
<4>: 0 (other)
AUX?
Command format
Returned format
Front panel status
AUX?/[ ]
AUX:<1><2><3>
Status of AUX1
BAR?
Command format
Returned format
0 = OFF
1 = ON
Status of AUX2
0 = OFF
1 = ON
Status of EXT TC
0 = OFF
1 = ON
Ex.) AUX : 100
AUX1 = ON
AUX : 010
AUX2 = ON
AUX : 001
EXT TC = ON
Bar meter setting read
BAR?/[ ]
BAR:<1><2>
<1>: 0 = Real-time mode, 1 = Peak hold mode
<2>: 0 = Unidirectional mode, 1 = Bidirectional mode
Related command: BAR
12-10
Command
BAT?
Command format
Returned format
Contents
Battery status
BAT?/[ ]
BAT:<1><2><3><4>
<1>: 0 = No battery, 1 = Battery present
<2>: 0 = Not discharging, 1 = Discharging
<3>: 0 = Not charging, 1 = Charging
<4>: 0 = Battery dead, 1 = Less than 20%, 2 = Less than 40%, 3 = Less than 60%,
4 = Less than 80%, 5 = 80% or more
CAL?
Command format
Returned format
Calibration status
CAL?/[ ]
CAL:<1>
<1>: 0 = Calibration finished normally
1 = Calibration finished abnormally
2 to 7: Calibration progress
Related command: CAL
CHA?
Command format
Channel mode setting read
CHA? <1>/[ ]
<1>: 0 = Recorder setting data, 1 = Tape data
Returned format
CHA:<1><2>
<1>: Analog channel code
<2>: Digital channel code
0 = OFF
1 = RSV
1 = 1ch (Async)
2 = RSV
2 = 2ch (Async)
3 = RSV
3 = 4ch (Async)
4 = RSV
4 = 8ch (Async)
5 = 16ch (SIR-1000/1000i)
5 = RSV
6 = 32ch (SIR-1000/1000i)
6 = SVB-10
7 = 64ch (SIR-1000/1000i)
7 = RSV
8 = 128ch (SIR-1000/1000i)
8 = RSV
9 = RSV
9 = RSV
A = RSV
A = 1ch (Sync)
B = 2ch (SIR-1000W)
B = 2ch (Sync)
C = 4ch (SIR-1000W)
C = 4ch (Sync)
D = 8ch (SIR-1000W)
D = 8ch (Sync)
E = 16ch (SIR-1000W)
E = RSV
F = RSV
F = RSV
Related command: CHA
12-11
Command
12-12
Contents
CFG?
Command format
Returned format
Recorder configuration
CFG?/[ ]
CFG:<1><2><3><4><5><6><7><8><9><10>
<1>: 0 = SIR-1000, 1 = SIR-1000W, 2 = SIR-1000i
<2>: Option slot 1 type
0 = None
1 = RSV
2 = STB-10
3 = STB-30
4 = RSV
5 = RSV
<3>: Option slot 2 type
0 = None
1 = Channel expansion board
2 = RSV
3 = RSV
4 = SSB-10A
5 = SSB-10S
6 = SVB-10
<4>: Channel expansion unit ID = 1
0 = None
1 = SCX-32/16W
2 = SCX-32i
SIR-1000/1000i
SIR-1000W
<5>: Channel expansion unit ID = 2
<5>: RSV
0 = None
<6>: RSV
1 = SCX-32
.
.
.
.
2 = SCX-32i
.
.
<10>: Channel expansion unit ID = 7
<10>: RSV
0 = None
1 = SCX-32
2 = SCX-32i
Ex.) CFG?
CFG : 2011220000
(The SIR-1000i is equipped with the channel expansion board at option slot number 2,
and SCX-32 is connected to ID=1 and SCX-32i is connected to ID=2 and ID=3 respectively.)
CMD?
Command format
Returned format
Command check
CMD?
CMD:<1>
<1>: 0 = No error in previous command, 1 = Error in previous command
Related command: CMD
ERR?
Command format
Returned format
Error check
ERR?
ERR:<1><2><3><4><5>
<1> : power supply system
0 = No error, 1 = Error
<2>: DSP system
0 = No error, 1 = Error
<3>: Analog system
0 = No error, 1 = Error
<4>: Drive system
0 = No error, 1 = Error
<5>: Peripherals
0 = No error, 1 = Error
Related commands: CAL, SLF
Command
Contents
FMT?
Command format
Returned format
Tape formatting execution status
FMT?/[ ]
FMT:<1><2><3><4>
<1>: 0 = Other than below (after power-on or STOP command execution, etc.)
1 = Tape formatting underway
2 = Tape formatting finished normally (becomes “0” after FMT?)
3 = Tape formatting finished abnormally (becomes “0” after FMT?)
<2><3><4>: ID number (001 to 999)
Related command: FMT
IDS?
Command format
Returned format
Tape ID number read
IDS?/[ ]
IDS:<1><2><3>
<1><2><3>: ID number (000 to 999)
Related command: IDS
INP? (SIR-1000/SIR-1000i only) Input format setting and reading
Command format
INP?<1><2>/[ ]
Returned format
INP? : <1><2>...<18>
<1>: 0 = Recorder setting data, 1 = Tape data
<2>: Channel expansion unit ID number
0 = Recorder
1 = Channel expansion unit 1
2 = Channel expansion unit 2
3 = Channel expansion unit 3
4 = Channel expansion unit 4
5 = Channel expansion unit 5
6 = Channel expansion unit 6
7 = Channel expansion unit 7
<3>: Input format for CH1
0 = DIRECT
1 = SENSOR
<4>: Input format for CH2
.
.
.
<18>: Input format for CH16
Related command: INP
LCH? (SIR-1000W only)
Command format
Returned format
LSB digital channel read
LCH? : <1>/[ ]
0 = Recorder setting data, 1 = Tape data
LCH : <1>
<1>: 0 = OFF
1 = 1ch
2 = 2ch
3 = 4ch
12-13
Command
LVA?
Command format
Contents
Signal level read (text format)
LVA? <1>/[ ]
<1>: Channel expansion unit ID number (0 = Recorder)
Returned format
LVA:<1><2>...<32> during unidirectional mode (related to BAR command)
<1><2>: CH 1 data (2-digit hexadecimal)
.
.
.
<31><32>: CH 16 data (2-digit hexadecimal)
7F = MAX and overload (OVR)
00 = MIN
Returned format
LVA:<1><2>...<64> during bidirectional mode (related to BAR command)
<1><2>: CH 1 +MAX data (2-digit hexadecimal)
<3><4>: CH 1 –MAX data (2-digit hexadecimal)
.
.
.
<61><62>: CH 16 +MAX data (2-digit hexadecimal)
<63><64>: CH 16 –MAX data (2-digit hexadecimal)
7F = +MAX and overload (OVR)
82 = –MAX and overload (OVR)
LVB?
Command format
Signal level read (binary format)
LVB? <1>/[ ]
<1>: Channel expansion unit ID number (0 = Recorder)
Returned format
LVB:<1><2>...<16> during unidirectional mode (related to BAR command)
<1>: CH 1 data (binary)
.
.
.
<16>: CH 16 data (binary)
7F = MAX and overload (OVR)
00 = MIN
Returned format
LVB:<1><2>...<32> during bidirectional mode (related to BAR command)
<1>: CH 1 +MAX data
<2>: CH 1 –MAX data
.
.
.
<31>: CH 16 +MAX data
<32>: CH 16 –MAX data
7F = +MAX and overload (OVR)
82 = –MAX and overload (OVR)
MAP?
Command format
Returned format
Slave ID read
MAP?
MAP:<1><2>...<14><15>
<1>: ID1
<8>: ID8
<2>: ID2
<9>: ID9
.
.
.
MEM?
Command format
.
.
.
<6>: ID6
<14>: ID14
<7>: ID7
<15>: ID15
Memo character string read
MEM? <1>/[ ]
<1>: 0 = Recorder setting data, 1 = Tape data
Returned format
MEM:<1><2>...<96>
<1><2>...<96>: Text characters up to maximum 96 characters
Related command: MEM
12-14
Command
MOD?
Contents
Tape transport mode read
Command format
MOD? /[ ]
Returned format
MOD:<1><2>
<1>: 0 = STOP, 1 = FWD, 2 = E-E, 3 = REC, 4 = FWD-PAUSE, 5 = REC-PAUSE, 6 = FF,
7 = RSV, 8 = REW, 9 = RSV, A = EJECT
<2>: S = During STOP transition
P = During PAUSE transition
0 = The end of transition
F = During FWD Transition (Only sync mode)
Related command: MOD
MON?
Monitor channel setting read
Command format
MON? /[ ]
Returned format
MON:<1><2>
<1>: Channel expansion unit ID number
<2>: Channel code
0 = Recorder
0 = CH 1
1 = Unit ID 1 (SIR-1000/1000i)
1 = CH 2
2 = Unit ID 2 (SIR-1000/1000i)
2 = CH 3
3 = Unit ID 3 (SIR-1000/1000i)
3 = CH 4
4 = Unit ID 4 (SIR-1000/1000i)
4 = CH 5
5 = Unit ID 5 (SIR-1000/1000i)
5 = CH 6
6 = Unit ID 6 (SIR-1000/1000i)
6 = CH 7
7 = Unit ID 7 (SIR-1000/1000i)
7 = CH 8
8 = CH 9
9 = CH 10
A = CH 11
B = CH 12
C = CH 13
D = CH 14
E = CH 15
F = CH 16
Related command: MON
OFA?
Command format
Auto offset setting status
OFA? <1>/[ ]
<1>: Channel expansion unit ID number (0 = Recorder)
Returned format
OFA:<1>
<1>: 0 = Auto offset setting finished, 1 = Auto offset setting underway
Related command: OFA
OFS?
Command format
DC offset value read
OFS? <1><2>/[ ]
<1>: 0 = Recorder setting value, 1 = Tape data
<2>: Channel expansion unit ID number (0 = Recorder)
Returned format
OFS:<1><2>...<32>
<1><2>: CH 1 DC offset (2-digit hexadecimal 2’s complement display)
.
.
<3><4>:
CH 2 DC offset (2-digit hexadecimal 2’s complement display)
.
<31><32>: CH 16 DC offset (2-digit hexadecimal 2’s complement display)
Related command: OFS
12-15
Command
OPL?
Command format
Returned format
Contents
Output level setting read
OPL? <1><2>/[ ]
<1>: 0 = Recorder setting value, 1 = RSV
<2>: Channel expansion unit ID number (0 = Recorder)
OPL:<1><2>...<16>
<1>: CH 1 output level code
<2>: CH 2 output level code
.
.
.
<16>: CH 16 output level code
Output level code
0 = RSV, 1 = RSV, 2 = 5 V, 3 = 2 V, 4 = 1 V, 5 = RSV, 6 = RSV, 7 = RSV, 8 = RSV,
9 = RSV, A = Manual
Related command: OPL
PNL?
Command format
Returned format
Panel lock status read
PNL?/[ ]
PNL:<1>
<1>: 0 = Panel lock canceled, 1 = Panel lock set
Related command: PNL
PSV?
Command format
Returned format
Power-save status
PSV?/[ ]
PSV:<1>
<1>: 0 = Power-save canceled, 1 = Power-save
Related command: PSV
RNA?
Command format
Auto range setting status read
RNA?<1>/[ ]
<1>: RSV (always 0)
RNA:<1>
<1>: 0 = Auto range setting finished, 1 = Auto range setting underway
Related command: RNA
Returned format
RNG?
Command format
Returned format
Range setting value read
RNG? <1><2>/[ ]
<1>: 0 = Recorder setting value, 1 = Tape data
<2>: Channel expansion unit ID number
0 = Recorder
1 = Channel expansion unit 1
2 = Channel expansion unit 2
3 = Channel expansion unit 3
4 = Channel expansion unit 4
5 = Channel expansion unit 5
6 = Channel expansion unit 6
7 = Channel expansion unit 7
RNG:<1><2>...<16>
<1>: CH 1 input range code
<2>: CH 2 input range code
.
.
.
<16>: CH 16 input range code
Input range code
0 = 20 V, 1 = 10 V, 2 = 5 V, 3 = 2 V, 4 = 1 V, 5 = 0.5 V, 6 = 0.2 V, 7 = 0.1 V
Related command: RNG
12-16
Command
RPT?
Contents
Auto repeat status read
Command format
RPT? /[ ]
Returned format
RPT:<1>
<1>: 0 = Other than below
1 = Auto repeat - recording
2 = Auto repeat - rewinding
Related command: RPT
SCH?
Command format
Returned format
Search status
SCH? /[ ]
SCH:<1>
<1>: 0 = Other than below (after power-on STOP command execution)
1 = Search underway
2 = Search finished (FOUND)
3 = Search finished (NOT FOUND)
Related command: SCH
SLF?
Command format
Returned format
Self-check status
SLF? /[ ]
SLF:<1>
<1>: 0 = Other than below (after power-on STOP command execution)
1 = Self-check underway
2 = Self-check finished (OK)
3 = Self-check finished (NG)
Related command: SLF
Related command: ERR?
SPD?
Command format
Tape speed read
SPD? <1>/[ ]
<1>: 0 = Recorder setting value, 1 = Tape data
Returned format
SPD:<1>
<1>: 0 = 1 ×, 1 = 1/2 ×, 2 = 1/4 ×, 3 = 1/8 ×, 4 = 1/16 ×, F = EXT
Related command: SPD
SPO?
Command format
Returned format
Speaker source selection status
SPO? /[ ]
SPO:<1>
<1>: 0 = Voice channel, 1 = Monitor selected data channel
Related command: SPO
12-17
Command
STA?
Contents
Status A
Command format
STA? /[ ]
Returned format
STA:<1><2><3><4><5><6><7>
<1>: Tape loading status
0 = Tape not loaded
1 = Loading underway
2 = Loading finished (tape loaded)
3 = Eject underway
<2>: Tape position
0 = Other than below
1 = BOD
2 = EOD
3 = EOT
<3>: TOC
0 = TOC not registered in flash memory
1 = TOC registered in flash memory
<4>: MIC
0 = Without MIC
1 = With MIC
<5>: Write protect
0 = Protect OFF
1 = Protect ON
<6>: Tape type
0 = 25 G
<7>: Tape format
0 = Standard
TIM?
Command format
Real-time clock read
TIM? <1>/[ ]
<1>: 0 = Recorder setting value, 1 = Tape data
Returned format
TIM:<1><2>...<12>
<1><2>: Year (last 2 digits)
<3><4><5><6>: Month and date
<7><8><9><10><11><12>: Hours, minutes and seconds
Related command: TIM
12-18
Command
TOC?
Command format
Contents
TOC data read
TOC? <1><2><3>/[ ]
<1><2><3>: ID number
Returned format
TOC:<1><2>...<25>
<1>: Start ID
0 = Not start ID, 1 = Start ID
<2>: REC mode
0 = 16 ch analog mode (standard)
1 = Full analog mode
2 = Full digital mode (when SBS-10A/S is used)
3 = Analog + digital mode
<3>: CH code
When <2> is 0, 1, or 3, which means analog CH mode.
1 = 2 ch, 2 = 4 ch, 3 = 8 ch, 4 = 16 ch, 5 = 32 ch, 6 = 64 ch, 7 = 128 ch
When <2> is 2, which means digital CH mode.
1 = 1 ch, 2 = 2 ch, 3 = 4 ch, 4 = 8 ch
<4>: Recording speed
0 = 1 × (normal speed), 1 = 1/2 ×, 2 = 1/4 ×, 3 = 1/8 ×, 4 = 1/16 ×,
A = 2 ×, B = 4 ×, C = 8 ×, F = EXT
<5>: Reservation
Always 0
<6>-<17> Recording start time
<6><7>: Year (last 2 digits)
<8><9><10><11>: Month and date
<12><13><14><15><16><17>: Hours, minutes and seconds
<18> : Existence of pre-trigger recording
0 = No pre-trigger recording
1 = Pre-trigger recording
<19> : Existence of recording error
0 = No write error
1 = Write error
<20><21><22><23><24><25>: Actual recording length
hhmmss
Related command: VOL?
TRG?
Trigger mode setting status
Command format
TRG? /[ ]
Returned format
TRG:<1>
<1>: 0 = Trigger invalid
1 = Pre-trigger single mode (low: start)
2 = Pre-trigger multi mode (low: start, high: stop)
3 = Normal single mode (low: start)
4 = Normal multi mode (low: start, high: stop)
Related command: TRG
12-19
Command
TRM?
Contents
Terminator selection status (returned strings)
Command format
TRM?/[ ]
Returned format
TRM:<1>
<1>: 0 = CR + LF, 1 = CR, 2 = LF
Related command: TRM
TSG?
Command format
Returned format
Test signal selection status
TSG? /[ ]
TSG:<1>
<1>: Test signal selection
Analog channel
Digital channel
0=
OFF
OFF
1=
AC
010000000000000001000..
2=
+DC
110000000000000000111..
3=
–DC
010000000100000001000..
4=
GND
000000000000000000000..
5=
EXT
010101010101010101010..
Related command: TSG
UTL?
Utility mode setting read
Command format
UTL? /[ ]
Returned format
UTL:<1><2><3><4><5><6>
<1>: 0 = AT FMT OFF
1 = AT FMT ON
<2>: 0 = ERA OFF
1 = ERA ON
<3>: 0 = DEW OFF
1 = DEW ON
<4>: 0 = BOT EJCT OFF
1 = BOT EJCT ON
<5>: 0 = SKP ET03 OFF
1 = SKP ET03 ON
<6>: 0 = CMP MODE OFF
1 = CMP MODE ON
Related command: UTL
VOL?
Tape volume read
Command format
VOL? /[ ]
Returned format
VOL:<1><2>...<32>
<1>: Format
0 = Standard
<2>: SIR type
0 = SIR-1000
1 = SIR-1000W
2 = SIR-1000i
<3><4><5><6>: Total IDs (max. 1000)
<7><8><9>: Total IDs inside MIC (max. 100)
<10><11><12><13><14>: TOC recording position (record number)
<15><16><17><18><19><20>: Last recorded SIR serial number
<21><22>: Last recorded year (last 2 digits)
<23><24><25><26>: Last recorded month and date
<27><28><29><30><31><32>: Last recorded hours, minutes and seconds
Related command: TOC?
12-20
13 Guard Frames
The recorder can be used the SHL-10 guard frames (sold separately), thus protecting the
recorder during transport and securring to the body of a vehicle.
Before use
The guard frames are secured to the recorder using eight hexagonal socket head bolts, two
each on the front, rear and sides of the recorder.
These bolts are also used to secure the side panels of the recorder, so do not attach or
remove the guard frames all at once, but one side at a time in order.
Items Used
• Guard frames : 4 frames (all same shape)
• Allen wrench : For hexagonal socket head bolts (4 mm)
Attaching the Guard Frames to the Recorder
1
Remove two 4 × 10 hexagonal socket head bolts from the forward right side of the
recorder.
2
3
Set the guard frame to the recorder with the protection sheet side facing inward.
Use two of the 4 × 16 hexagonal socket head bolts supplied with the guard frame to
secure it to the recorder.
Note
First temporarily tighten both hexagonal socket head bolts and then tighten the bolts
securely.
4
Attach the remaining three frames similarly in order.
Guard frame
4 × 16 hexagonal
socket head bolt
13-1
14 Battery Pack
When the BP-L60/L60A or BP-L90/L90A battery pack (both sold separately) is mounted,
the recorder can also be used even where there is no external AC or DC power supply.
When using an extension unit or an option board, use BP-L90/L90A.
Before Use
Be sure to charge the lithium-ion rechargeable battery before use.
Before charging with the dedicated battery charger BC-L100 (sold separately), be sure to
read the charger’s instruction manual.
Battery life
Battery packs that only last for a short time after they have been charged have reached the
end of their useful life. Replace it with a new battery pack.
When not using
• Remove the battery pack from the unit and store it in a dry and well-ventilated location.
• When the battery pack will not be used for a long time, discharge the battery pack before
storing.
! WARNING
•
•
•
•
•
•
•
Only use the dedicated charger.
Do not leave the battery near a fire or throw it into a fire.
Do not short the battery (connect the positive and negative terminals with a wire, etc.).
Do not allow the battery to become wet.
Do not apply strong shock to or drop the battery.
Do not change the shape, modify, or disassemble the battery.
If leakage from the battery gets in your eyes, wash your eyes with clean water and see
a doctor immediately.
! CAUTION
•
•
•
•
Do not remove the battery’s outer jacket or otherwise damage the battery.
Do not use the battery with others of different kinds, ratings, or brands.
Do not charge longer than the specified.
Do not use the battery in case of battery deformation, leakage, discoloration or when
other abnormalities are found.
• If leakage from the battery sticks to you skin or clothes, wash it off with clean water.
Note
Used batteries are to be recycled. Stick insulation tape on the terminals of used
batteries and take them to a store handling recycling products or to a Sony Precision
Technology outlet.
14-1
Charging the Battery Pack on the Recorder
1
Mount the BP-L60/L60A or BP-L90/L90A battery pack (both sold separately) on the
battery pack mount on the left side of the recorder.
2
Supply the specified AC power source to the recorder. Charging can be used regardless
of the STAND BY switch position.
Note
• When the battery pack is mounted on the recorder, charging begins, the BATT LED
blinks and the ventilation fans rotate. Once charging is completed, the BATT LED
turns off.
It takes approximately 8 hours for BP-L60/L60A or 12 hours for BP-L90/L90A to
charge at 25°C (environmental temperature).
• When other functions of the recorder are not being used, set the STAND BY switch
to OFF. When charging is completed, the power to the recorder is turned off
automatically.
• When one or more channel expansion units are connected, it takes approximately ten
times to charge the battery.
3
4
14-2
When charging is completed, the BATT LED turns off.
Remove the battery pack from the recorder.
15 Remote Control Unit
The recorder can be operated from a distance by connecting the remote control unit SRM10 (sold separately).
Functions
Command functions
The remote control unit can output the following commands to the recorder:
• Tape transport mode setting
• Input range setting (per channel or all channels at once)
• Input DC offset setting (per channel or all channels at once)
• ID increment
• Monitor channel setting
• Search (ID search, EOD search)
Monitoring Functions
The remote control unit can display the following states of the recorder:
• Loading status
• Tape transport mode
• Channel mode
• Tape speed
• Signal level per channel (bar meter)
• Over-range
• Input range
• Input DC offset
• ID number
• Monitor channel
• Test signal type
• External time code signal level
• Tape position information
• Alarm display
• Error code
15-1
Interface
Signal format : EIA RS-232C protocol
Connector
: Round, 12-pin
Transfer rate : 9600 bps, synchronous
Connector Pin Assignment
Signal
name
Pin No.
Function
Pin No.
Signal
name
Function
1
+6V
Power supply
7
RSV
2
EXT TC
IRIG-B input
8
RXD
RS-232C input
3
SG
RS-232C signal ground
9
TXD
RS-232C output
4
SG
RS-232C signal ground
10
FG
RS-232C shield
5
RSV
11
RSV
6
RSV
12
RSV
Connecting the Remote Control Unit
Connect the round connector of the remote control unit to the REMOTE connector on the
rear panel of the recorder.
! SELECTOR
!
220V
9
8
25
6
7
24
21
22
23
19
20
18
17
16
15
14
1
5
4
3
2
13
12
COM
11
10
9
8
7
6
AUX-2 (IRIG-B)
IN
OUT
VOLTAGE
AC FUSE
T4A
8 7 6 5 4 3 2 1
5
4
3
2
1
EXT. CONT
REMOTE
SYNC
AUX-1 (DIGITAL)
IN
OUT
TRIG/REC
IN
% / dB
MST / SLV
IRIG ON / OFF
APD OFF / ON
(UP / DOWN)
RAL / HLD
9.6 / 19.2
TRG S/M
PTRG OFF/ON
240V
DC IN
STAND BY
AC IN
DC BREAKER
XLR 32F
CANNON
OPTION SLOT 1
OPTION SLOT 2
D4
D3
D2
D1
LSB DIGITAL
OUTPUT
8
7
6
5
4
3
2
1
ANALOG
OUTPUT
Remote control unit SRM-10
To REMOTE
LOADING
dB
%
OVR 1 1/2 1/4 1/8 1/16 1 2
SPD
AUX
EXT TC
EXP SYN
ID
BOD
EOD
CAUTION
ID
OVR
RANGE
OFFSET
PNL LOK
+2
+100
0
–6
MONI
SPEED
V X1/
S- TIME
ADDRESS REMAIN T - T I M E
Y
M
D
H
M
S
0
-40 -100
OVR
CH
RANGE
CH
-20
1-4 5-8
9-12 13-16
PK-CLR
ALL CH SELECT
REW
FF
PAUSE
FWD
STOP
REC
LOAD
REMOTE CONTROL UNIT SRM-10
15-2
Operation
With the exception below, keys and displays of the remote control unit have the same
names and functions as those of the recorder.
PNL LOK Key
Press this key for at least 2 seconds to select the panel lock mode. The LED to the upper
left of the key lights, and all keys on the front panel of the recorder are disabled.
To cancel the panel lock mode, press this key again for at least 2 seconds. The LED to the
upper left of the key turns off.
PNL LOK key
LOADING
dB
%
OVR 1 1/2 1/4 1/8 1/16 1 2
SPD
AUX
EXT TC
EXP SYN
ID
BOD
EOD
CAUTION
ID
OVR
RANGE
OFFSET
PNL LOK
+2
+100
0
–6
MONI
SPEED
CH
V X1/
S- TIME
ADDRESS REMAIN T - T I M E
Y
M
D
H
M
S
0
-20
-40 -100
OVR
CH
RANGE
1-4 5-8
REW
9-12 13-16
PK-CLR
FWD
ALL CH SELECT
FF
PAUSE
STOP
REC
LOAD
REMOTE CONTROL UNIT SRM-10
For items other than that above, refer to the text for the recorder, as follows:
Item
Page
No.
Item
Page
No.
LOADING LED
3-3
5
AUX LEDs (1, 2)
3-15
#£
PAUSE key
3-5
7
EXP LED
3-15
#¢
REC key
3-5
8
SYN LED
3-15
#∞
STOP key
3-5
9
EXT TC LED
3-15
#§
FWD key
3-5
0
Bar meter area
3-16
#¶
FF key
3-5
!¡
ID display area
3-17
#•
EOD LED
3-6
!™
CAUTION display area
3-17
#ª
REW key
3-6
!£
MONI display area
3-17
$º
BOD LED
3-6
!¢
RANGE display area
3-17
$¡
RANGE key
3-9
!¶
SPEED display area
3-17
$™
OFFSET key
3-9
!•
Tape position display area
3-18
$£
ID/UTL key
3-11
@™
PK-CLR key
3-19
$¢
: key
3-13
@¢
ALL CH key
3-19
$∞
8 key
3-13
@∞
SELECT key
3-19
$§
OVR LED
3-15
#¡
LOAD key
3-19
$¶
SPD LEDs
3-15
#™
Note
It jumps to the beginning after shifting the value or digit to the end with : key or 8 key
then press the key again.
15-3
16 Channel Expansion Unit
The SIR-1000W can simultaneously record and play back analog data signals of up to 16
channels by using the channel expansion unit SCX-16W (sold separately).
The number of channels and the bandwidths are as follows:
Number of Channel
16
Number of
Channel Expansion Unit
1
DC to 40 kHz
1/2
DC to 20 kHz
1/4
DC to 10 kHz
Tape speed
1 (normal speed)
1/8
DC to 5 kHz
1/16
DC to 2.5 kHz
16-1 Prior to Operation
• Be sure that the main power is OFF before connecting the SIR-1000W and the SCX16W.
• Power for the SCX-16W is supplied from the SIR-1000W when the SIR-1000W is
driven by AC, DC (15 to 30 V) or battery (BP-L90/L90A).
! WARNING
Do not block the ventilation of the SCX-16W.
!
CAUTION
• Connect the ground terminals of the SIR-1000W and SCX-16W with lead wire in order
to prevent electro-static noise.
• Be sure to disconnect the extension cable from the SIR-1000W when the SCX-16W is
not used in order to prevent the unit from noise.
16-1
16-2 Names and Functions of Parts
Front Panel
1
4
CHANNEL EXPANSION UNIT
POWER
dB
2
SCX- 16W
%
BAND
0VR
40k
0 100
20k
-6
50
- 20
10
10k
5k
ANALOG
INPUT
≤ ± 2 6 . 6 v p k 1 0 0k
9
10
11
12
13
14
15
16
2.5k
3
REF
1 POWER LED
Lights when power is supplied to the SCX-16W, and blinks when the power voltage
is lower than the specified value. Turn the power ON/OFF with the STAND BY switch
on the SIR-1000W. If the SIR-1000W is not connected, power cannot be supplied.
2 Bar meters
Display the analog data signal levels for channels 9 to 16 with a unidirectional row of
LEDs, in either dB scale (–20 dB, –6 dB, 0 dB, OVR) and percentage scale (10%, 50%,
100%, OVR). When the level for any channel is beyond the range, the corresponding
OVR LED lights.
Note
Since the bar meter of this SCX-16W indicates the level in one direction regardless of
the signal polarity, even when the level is displayed in percentage scale, the indication
may differ from that of the SIR-1000W.
The signal level of the SCX-16W can be monitored by the bar meters on the SIR1000W.
3 ANALOG INPUT connectors
Used to input the analog data signals of channels 9 to 16.
! CAUTION
• Be sure to input signals within the specified voltage range (±26.6 Vpk).
• Internal circuit may be damaged if the voltage more than ±100 Vpk is input.
Note
When EXT is selected as the test signal, the signal input to channel 9 of the SCX-16W
is used as the test signal for all channels of that unit.
4 BAND LEDs
The bandwidth LED (40 k, 20 k, 10 k, 5 k, 2.5 k) lights according to the channel mode
and tape speed set by the SIR-1000W.
16-2
Rear Panel
3
1
2
XLR 32F
EXPANSION IN
DC IN
BREAKER
CANNON
4
16
15
14
13
12
11
10
9
ANALOG
OUTPUT
5
6
1 DC IN connector
External DC power (rated 12 V, arrowable 11 to 30 V) can be supplied to this
connector.
! CAUTION
• The polarities of the DC power cord (supplied) are red = positive and black =
negative.
• The connector pin assignment is Pin 1 = positive, Pin 2 = negative and Pin 3 = Frame
GND.
• Only when a stable DC voltage which keeps more than 15 V is supplied to SIR1000W. DC voltage is supplied to the SCX-16W from SIR-1000W.
• In case the above-mentioned stable DC power supply cannot be supplied.
DC voltage (11 to 30 V) must be supplied to both SIR-1000W and SCX-16W.
2 DC circuit breaker
DC power supply breaker.
3 EXPANSION IN connector
Connector for the expansion cable between the SIR-1000W and SCX-16W.
4 GROUND terminal
This terminal has the same electric potential as the signal line on the ground side and
the frame.
5 Output level adjustment potentiometers
Used to adjust the output level of the analog data signals for channels 9 to 16. Enabled
when the SIR-1000W is set to the manual position by pressing the OUT/TSG key.
6 ANALOG OUTPUT connectors
Used to output the analog data signals of channels 9 to 16.
Connect BNC cables (sold separately) to these connectors.
16-3
Left Side Panel
1
1 Ventilation slits
For taking air into the unit to cool inside of the unit.
! WARNING
• To prevent the inside of the SCX-16W from overheating, do not block the ventilation
slits.
• Do not place hot objects on the left side of the SCX-16W.
• Leave a space of at least 50 mm between the left side of the SCX-16W and any other
object.
Right Side Panel
1
SCX-16W
11-30V
*.*A/12V
Sony Precision Technology Inc.
1 Ventilation fan
Cools inside of the SCX-16W.
! WARNING
Do not block the air outlet.
16-4
SER.
MADE IN JAPAN
*-***-***-**
16-3 Connecting to the SIR-1000W
1
2
Turn OFF the main power to the SIR-1000W.
3
Use the expansion cable (supplied) to connect the EXPANSION OUT connector of the
connection board mounted in the rear of the SIR-1000W and the EXPANSION IN
connector of the SCX-16W.
4
5
Turn ON the SIR-1000W’s power.
Remove the cover for the OPTION SLOT 2 of the rear panel of the SIR-1000W by
loosing two +3×20 screws, then insert the supplied connection board in the OPTION
SLOT 2 and tight two +3×20 screws.
Using the supplied combining frames (four in all for the front, rear, left and right) to
attach the SIR-1000W and SCX-16W facilitates carrying and fixing to a base.
! CAUTION
• When using the SIR-1000W with an external DC power supply of less than 15 V, be
sure to supply power directly from the same power supply to the SCX-16W. Note that
when using the SIR-1000W with an AC power supply, the battery pack or an external
DC power supply of 15 V or more, power is supplied to the SCX-16W via the
recorder.
• The expansion extension cable (SDK-10: sold separately) cannot be used.
Using the Combining Frames
Before use
To attach combining frames, use 12 hexagonal socket head bolts (4 × 16) on th e front, rear,
left and right sides of the SIR-1000W and SCX-16W. These bolts also attach the left and
right side frames of the SIR-1000W and SCX-16W, so do not attach or remove the
combining frame all at once, but one side at a time in order.
Items used
• Combining frames (all the same shape) : 4
• Hexagonal socket head bolts (4×16)
: 12
• Allen wrench
:1
16-5
Attaching the Combining Frames
1
2
Prepare a 4 mm Phillips screwdriver.
Turn the SIR-1000W upside down. Use the screwdriver to remove the four screws +
PS3 × 6 fastening the front and back feet, and remove the feet.
BKW-L601
+ PS3 × 6
3
4
Place the SCX-16W on top of the SIR-1000W.
5
Remove the one hexagonal socket head bolt (4 × 12) from the forward right side of the
SCX-16W.
6
Face the protection sheet side of a combining frame inward, and place it to the SIR1000W and SCX-16W.
7
Attach one of the combining frames to the SIR-1000W and SCX-16W, and fasten the
frame with supplied three hexagonal socket head bolts (4×16).
Remove the two hexagonal socket head bolts (4 × 12) from the forward right side of
the SIR-1000W.
Note
After temporarily fixing the three bolts, tighten the bolts securely.
8
Attach the remaining frames in a similar manner.
SIR-1000W
Combining frame
SCX-16W
16-6
16-4 Operation
Connecting the Data Signal System
1
Using a BNC cable (sold separately), connect the INPUT connector of each channel
to a signal source, and connect the OUTPUT connector of each channel to the
measuring equipment.
Recording (analog mode)
1
To adjust the input range, input DC offset and output level, first select the unit with the
8 and 9 keys, then set these items using the switches on the SIR-1000W unit.
2
Data recording operations are the same as for the SIR-1000W alone.
Playback (analog mode)
1
When playing back a tape recorded on the SIR-1000W, the same channel mode used
for the recording is automatically set, and the data signal is output to the OUTPUT
connectors of the SCX-16W and MONI connectors of the SIR-1000W.
2
Data playback operations are the same as for the SIR-1000W alone.
Calibration
Calibration is executed for SCX-16Ws according to the SIR-1000W’s calibration operation.
16-7
17 Synchronizing Mode
Synchronous recording and synchronous playback can be performed by connecting two
recorders using the sync cable SCK-10 (sold separately) and setting both recorders to the
synchronizing mode.
This means that the number of channels can be doubled (maximum 256 channels) without
changing the analog data signal bandwidth. The channel mode for the master and slave
units can be changed so that signals of different bandwidths can be recorded or played back
simultaneously and the input data mode can be changed so that signals of different analog
and digital formats can be recorded or played back simultaneously.
17-1 Before Operation
• Be sure to turn off the power switches of both recorders before they are connected with
the sync cable.
• Power is supplied separately. Supply the specified power to both recorders and any
channel expansion units.
• Be sure to set one recorder as the master and one as the slave. Use the digital switch on
the rear panel for the setting.
• If the recorders are not connected by the sync cable, both recorders operate as master,
regardless of the setting of the digital switch on the rear panel.
• When the Self-check or Calibration is to be performed, each unit Master/Slave must be
performed individually by disabling synchronous mode (e.g. the switch on the Slave
unit set to Master).
• When IRIG-B timecode signal is used during synchronized recording, input the
timecode signal only to the master (i.e. do not input the timecode signal to the slave).
• When the recorder is connected through the sync cable, be sure to supply the power to
both master and slave units.
17-1
17-2 Connecting and Setting
8 7 6 5 4 3 2 1
8 7 6 5 4 3 2 1
MST / SLV
MST / SLV
Master
Slave
25
6
7
13
24
12
21
22
23
11
10
9
19
20
8
7
18
6
17
5
16
4
15
3
14
2
1
REMOTE
9
8
25
6
7
24
21
22
23
19
20
18
17
16
15
14
1
5
DC BREAKER
4
3
2
13
12
11
10
9
8
7
6
5
4
3
2
1
S
HR
COM
AUX-2 (IRIG-B)
IN
OUT
VOLTAGE
AC FUSE
T4A
! SELECTOR
!
1
2
EXT. CONT
STAND BY
AC IN
3
240V
DC IN
XLR 32F
8
TRIG/REC
IN
8 7 6 5 4 3 2 1
220V
4
SYNC
AUX-1 (DIGITAL)
IN
OUT
9
COM
AUX-2 (IRIG-B)
IN
OUT
! SELECTOR
!
RAL / HLD
9.6 / 19.2
TRG S/M
PTRG OFF/ON
220V
5
EXT. CONT
REMOTE
VOLTAGE
AC FUSE
T4A
8 7 6 5 4 3 2 1
% / dB
MST / SLV
IRIG ON / OFF
APD OFF / ON
(UP / DOWN)
SYNC
AUX-1 (DIGITAL)
IN
OUT
TRIG/REC
IN
% / dB
MST / SLV
IRIG ON / OFF
APD OFF / ON
(UP / DOWN)
RAL / HLD
9.6 / 19.2
TRG S/M
PTRG OFF/ON
240V
DC IN
STAND BY
AC IN
DC BREAKER
XLR 32F
S
HR
CANNON
CANNON
OPTION SLOT 2
D4
D3
D2
OPTION SLOT 2
OPTION SLOT 1
D1
LSB DIGITAL
OUTPUT
8
7
6
5
4
3
2
1
ANALOG
OUTPUT
D4
D3
D2
OPTION SLOT 1
D1
LSB DIGITAL
OUTPUT
8
7
6
5
4
3
2
1
ANALOG
OUTPUT
Sync cable
1
Turn OFF the power switches of both recorders, and connect them using the sync cable
via their SYNC connectors on the rear panels.
2
Use the MST/SLV digital switch on the rear panel to set one recorder as master and the
other as slave. When a recorder’s switch is in the upper position, it is the master, and
when in the lower position, it is the slave.
3
4
Turn ON the power switch of the slave first, and then the master.
5
When using a remote control unit, RS-232C control, or EXT. control, be sure these are
connected to the master’s connector.
Make sure that both the SYN LEDs on the front panel of the master and the slave start
blinking.
Note
When the power switch of the slave is turned ON, the SYNC ID that is set by the UTL mode
is displayed on the LCD screen until launching the next operation.
17-2
17-3 Operation
Synchronous Recording
1
Settings prior to recording
Insert a cartridge in each recorder, and perform any of the following settings that are
necessary for each individual recorder and channel expansion unit.
• Channel mode (BCM)
• Input range (RANGE)
• Input DC offset (OFFSET)
! CAUTION
• For synchronous recording in the pre-trigger mode is not supported. Set the digital
switch PTRG OFF/ON on the rear panel to OFF (upper position) during synchronizing
mode.
• As the setting time of the slave is the same as the master’s value, be sure to input the
IRIG-B timecode signal to the master.
2
Selecting the tape speed
To select the tape speed, press the SPEED key of the master. The tape speed of the slave
follows the master’s setting.
! CAUTION
Master operation does not follow slave operation.
3
ADDRESS setting
When recording starts in the synchronizing mode, the tape ADDRESSes of each
recorder are automatically reset to zero, and the slave operates in sync with the master
until the recording stops. Therefore, the corresponding positions on both tapes are
recorded with the same address.
4
ID number
• The ID numbers of all units are incremented uniformly when the master’s ID key is
pressed.
Note
If the master’s ID number differs from that of the slave, the ID numbers of the
synchronous data recorded on the tapes by synchronous recording will also differ.
Therefore, set the master and slave to the same ID number, start synchronous recording
from the start of both tapes or from areas with the same ID number (overwrite).
5
Starting recording
When the master enters the REC mode, the slave follows to perform synchronous
recording. The master’s real-time clock value is set to the slave each time the REC
mode starts.
The REC, STOP, E-E, REC-PAUSE, FWD, FF, REW and ID number search transport
modes follow the master’s settings.
! CAUTION
• Master operation does not follow slave operation.
• Continue synchronized recording longer than 00H00M05S of the ADDRESS
indication.
17-3
6
SYN LED
The SYN LED display is as follows in the synchronizing mode:
Status
During synchronous recording
During synchronous playback
During synchronous playback chase
During STOP, FF and REW
During self-check
7
Master
Slave
Lit
Lit
Blinking
Blinking
Off
Off
Trouble
If trouble occurs while the sync cable is connected, the display screen and the SYN
LED appear as follows:
Status
Master
Slave
LCD screen
SYN LED
Master POWER OFF
Off
Off
—
Off
Slave POWER OFF
EX30
Off
Off
Off
Cable connection trouble
EX30
Blinking
EX30
Blinking
MST/SLV switch incorrectly set
—
Off
—
Off
No data to be synchronized
—
EX31
Off
Blinking
(Operate independently)
LCD screen SYN LED
Note
• When cable connection trouble occurs, and the power switches of the recorders have
been turned OFF and then ON again, the recorders do not enter the synchronizing
mode, but operate independently.
• “MST/SLV switch incorrectly set” means that both recorders are set as “master” or
“slave”.
• “No data to be synchronized” means that there is no data to be synchronized on the
slave’s tape.
17-4
8
Append recording and overwritting
If the tape position of the slave is changed after synchronous recording stops, the
master and slave IDs will differ. For example, after stopping part-way through ID = 010
with the slave as shown below, when synchronous recording is started next, the master
records from the EOD following ID = 011, but the slave records from part-way through
ID = 010. As a result, part of the ID = 010 area on the slave side is deleted, and the ID
numbers of the new synchronous recording areas are 012 and 011 for the master and
slave, respectively. Synchronous playback can be performed with different ID numbers,
but starting recording from the EOD for both the master and slave is recommended.
Example 1.
Master tape recorded up to ID = 011
ID=010
ID=011
EOD
Slave tape recorded up to ID = 011
ID=010
ID=011
EOD
Example 2.
Master tape additionally recorded from the EOD above
ID=010
ID=011
ID=012
START
T=T0
STOP
T=T1
Slave tape recorded from part-way through ID = 010
ID=010
ID=011
START
T=T0
STOP
T=T1
17-5
Synchronous Playback
1
Settings prior to playback
Insert the tapes to be Played Back in the Recorders.
2
Starting playback
To start synchronous playback, press the FWD key of the master. The FWD key LED
and the SYN LED of the master blink. At the same time, the master controls the slave
to search data of the same position on the tape. When data of the same position from
both tape on the master and the slave are read, tape transport of each recorder starts to
playback data. The FWD key LED and the SYN LED of the master light during
synchronous playback.
During synchronous playback, multi-channel data with the same sampling time are
simultaneously output from both the master and the slave, enabling crystal precision
synchronization.
In addition, the data on tapes synchronously recorded using the data transfer software
PCscanIII can be transferred to a computer, allowing data with the same sampling time
to be monitored and analyzed.
Note
• If the channel mode and analog digital mode settings are different for the master and
slave, a certain time difference may arise between their playback outputs according
to the difference in the processing time inside each recorder.
• In order to guarantee synchronous accuracy from the stop position, data stored inside
the buffer during playback will be eliminated when the STOP or PAUSE is excuted
during synchronous playback operation. Accordingly, address will be advanced
about 20 seconds.
• If tape running mode differs between master unit and slave unit, master unit cannot
accept all keys other than STOP key.
• Synchronous playback is possible only for the same “record” on both the master and
the slave, i.e. it is impossible to playback data in synchronous mode over different
“records”. (Refer to “2-1 Tape Format”)
• When the “×” mark appears either master or slave, the synchronous playback is lost,
then start synchronous playback again after searching the vicinity of lost section
automatically.
• At the joint of a record, the slave stops playback taking in account of the tape recorded
other way than by synchronous recording, yet the master keeps playing back,
therefore the slave unit shows EX32 error.
17-6
18 Specifications
18-1 Cartridges
Product name
: SDX1-25C (with MIC)
SDX-T3C (with MIC)
SDX-T3N (without MIC)
Magnetic substance
: Pure cobalt vapor-deposited AME
Tape base material
: PET
Tape thickness
: 7 µm
Tape width
: 8.0 mm
Tape length
: 170 m
Cartridge external dimensions
: 95 (W) × 62 (H) × 15 (D) mm
Effective data capacity : 25 GB (without compression)
50 GB (Compression)
18-2 Tape Transport System
Head configuration
:
Head drum diameter
:
Head drum wrapping angle :
Head drum rotational speed :
Tape speed, relative speed :
2 for recording, 3 for playback
40 mm
212°
4800 rpm
Speed ratio
Tape speed
mm/s
Relative speed
m/s
1 (normal speed)
20.63
10.053
Track pitch
: 11 µm
Tracking system
: 3T ATF area division
Tape end detection
: By photo-sensor
Recording/playback direction
: Forward only
Motors
: 1× drum, 1× capstan, 2× reel, 1× tape loader, 1× cartridge loader
Drum control
: Speed control and phase control (recording/playback)
Capstan control
: Speed control and phase control (recording),
ATF control (playback)
Reel control
: Speed control and constant tension control
(recording/playback)
Fast-forward/rewind time
: Less than 2.5 minutes (at 70 times normal speed, 170 m tape)
Search speed
: 70 times normal speed (max.)
18-3 Recording/Playback System
Recording system
Playback system
Additional writing
Error correction
Recording/playback transfer rate
:
:
:
:
:
NRZ saturation azimuth recording
PR (1.1) viterbi decoding
Direct overwriting
Double Reed Solomon code
26.11 Mbps
18-1
18-4 Analog Channels
Number of channels
Expandability
Bandwidth
: 8 (SIR-1000W only)
: 16
: Channel
Bandwidth
Mode
Full analog mode
MIX
2
—
(DC to 160 kHz) × speed ratio
4
(DC to 160 kHz) × speed ratio
(DC to 80 kHz) × speed ratio
8
(DC to 80 kHz) × speed ratio
(DC to 40 kHz) × speed ratio
16
(DC to 40 kHz) × speed ratio
—
Speed ratio is the ratio of 1/2, 1/4, 1/8, and 1/16 to the normal speed.
Sampling frequencies
: 2.4 × Bandwidth (upper limit frequency of)
AD conversion
: 64-times over-sampling ∆-∑ modulation
DA conversion
: 2 to 128 times over-sampling successive conversion
Quantization
: 16-bit linear quantization
Filters (recording side) : First-order analog filter + FIR digital filter
Filters (playback side) : Seventh-order analog filter + FIR digital filter
Over-range
: ±33 %
Analog characteristics (Input ±133 % within Bandwidth)
AC characteristics
: Bandwidth
2.5 k to 40 kHz
80k/160kHz
Frequency response
Dinamic range
76 dB or more
74 dB or more
Crosstalk
–76 dB or less
–74 dB or less
Distortion
0.016 % or less
0.02 % or less
Bandwidth
REC
Interchannel
phase
REC + PB
difference
DC characteristics
DC to 40 kHz or less
40 kHz to 160 kHz
Inside a single unit : 1° or less
Between another unit : 2° or less
3°
Inside a single unit : 2° or less
Between another unit : 3° or less
5°
(The same input/output condition. Except sync mode)
: Bandwidth
Each Bandwith
Linearity
Drift
Input
Input format
Connectors
Range
DC offset
Impedance
Withstand voltage
Output
Connectors
Level
Impedance
Applicable load
18-2
+1.0 /–1.5 dB, 0 dB @200 Hz
±0.1 % or less
REC : ±0.1 % or less /2 hours
PB : ±0.1 % or less /2 hours
(from 15 minutes after power ON)
: Voltage input
: 8 × BNC (single ended)
: ±0.5, ±1, ±2, ±5, ±10, ±20 Vpk
: ±100 %
: ±100 Vpk
: ±100 Vpk
: 8 × BNC (single ended)
: ±1, ±2, ±5, variable (±0.5 to ±5) Vpk
: 50
: 10 k or more
LSB digital channel
Number of channels
Sampling frequencies
: 4
: 768 kHz × 1/LSB channel BCM × speed ratio
Tape Speed 1/1 (Normal Speed)
LSB digital 1 ch
LSB digital
SIR-1000W
(sampling frequency) LSB digital 2 ch
LSB digital 4 ch
Input
Connectors
Level
Impedance
Withstand voltage
Output
Connectors
Level
Impedance
Applicable load
1/2
1/4
1/8
1/16
768 kHz
384 kHz 192 kHz 96 kHz 48 kHz
384 kHz
192 kHz 96 kHz 48 kHz 24 kHz
192 kHz
96 kHz 48 kHz 24 kHz 12 kHz
:
:
:
:
BNC × 4 (unbalance)
TTL
10 k
±10 Vpk
:
:
:
:
BNC × 4 (unbalance)
TTL
50
1 k or more
18-5 AUX Digital Channel (AUX-1)
Number of channel
Sampling frequencies
Input
Connector
Level
Impedance
Withstand voltage
Output
Connector
Level
Impedance
Applicable load
: 1
: speed ratio × 384 kHz
:
:
:
:
1× BNC
TTL
10 k
±10 Vpk
:
:
:
:
1× BNC
TTL
50
1 k or more
18-3
18-6 AUX Analog Channel (AUX-2)
Number of channel
Bandwidth
Frequency response
Sampling frequencies
S/N ratio
Distortion
Input
Connector
Level
Level (IRIG)
Impedance
Withstand voltage
Output
Connector
Level
Level (IRIG)
Impedance
Applicable load
:
:
:
:
:
:
1
DC to (19.2 kHz × speed ratio)
+1/– 3 dB (0 dB @200 Hz)
speed ratio × 48 kHz
40 dB or more
1% or less
:
:
:
:
:
1× BNC
±2 Vpk (rated)
±1.0 to ±10 Vpk (detection range)
10 k
±50 Vpk
:
:
:
:
:
1× BNC
±2 V (rated)
Approx. ±1.5 V (fixed)
50
10 k or more
18-7 Voice Annotation Channel
Number of channels
: 1
Bandwidth
: 100 Hz to (19.2 kHz × speed ratio)
Input (MIC)
Connector
: 1× standard jack
AGC
: ±30 dB
Impedance
: 10 k
Output (PHONE)
Connector
: 1× mini-jack
Applicable load
: 8 or more
Output power
: Max. 400 mW @ 8
Output (speaker)
Speaker response bandwidth
: 100 Hz to 5 kHz
18-4
18-8 Operation System
Front Panel
Tape operation keys
REC
: E-E and recording mode
STOP
: Stop mode
FWD
: Playback mode
FF
: Fast-forward mode
REW
: Rewind mode
PAUSE
: Pause mode
Cartridge ejection button
EJECT
: For ejecting the cartridge
Mode setting keys
SHIFT
: For shifting keys and locking the panel
SPD/BCM
: For selecting the tape speed and channel mode
RANGE
: For setting the input range
OFFSET
: For setting the input DC offset
OUT/TSG
: For setting the output level and test signal
MRK/SLF
: For selecting the mark and self-check mode
SEARCH
: For selecting the search mode
ID/UTL
: For setting the ID number and increment/Utility mode
;
: For moving between digits (to the left)
:
: For moving between digits (to the right)
8
: For increasing the set value
9
: For decreasing the set value
Display setting keys
PK-CLR
: For clearing the peak indicator
ALL CH
: For setting all channels at once
SELECT
: For selecting the tape position information
LOAD
: For setting the tape setting conditions
CLOCK
: For setting the internal clock.
Other setting keys
DATA-ANN/P-SAVE : For setting the speaker source, power-save mode, or fan control mode
VOL
: For setting the playback sound level
Rear Panel
STAND BY switch
: For turning on and off the main power
VOLTAGE SELECTOR switch
: For switching the AC voltage (100 to 120 V and 220 to 240 V)
Digital switches
RAL/HLD
: For switching the bar meter peak indication
9.6/19.2
: For switching the RS-232C transfer rate
TRG S/M
: For switching the trigger modes single and multiple
PTRG OFF/ON
: For switching the pre-trigger recording modes off and on
APD OFF/ON
: For switching the auto power-down modes off and on
IRIG ON/OFF
: For switching IRIG time code input and output on and off
MST/SLV
: For setting the recorder to master or slave during synchronous operation
%/dB
: For switching the bar meter display scale
Output level adjustment potentiometers
: For adjusting the volume
18-5
18-9 Monitor System
LCD Screen
Display type
Bar meter
Digital mode display
ID
MONI
RANGE
SPEED
ADDRESS
REMAIN
S-TIME
T-TIME
CAUTION
: High-contrast, wide-angle LCD (with backlight)
: 16 ch simultaneous indication; percentage or dB scale
selectable
: Active only in full digital mode
: ID number (000 to 999) with auto-increment “A” indication
: Displays the monitored channel (01 to 16)
: Displays the input range (0.5, 1.0, 2.0, 5.0, 10, 20)
: Displays the recording tape speed
(× 1/1, × 1/2, × 1/4, × 1/8, × 1/16)
: Displays the tape address (±hour/minute/second)
: Displays the remaining tape amount (hour/minute)
: Displays the source time
(year/month/day and hour/minute/second)
: Displays the tape time
(year/month/day and hour/minute/second)
: Displays the warnings
(low DC voltage, dew condensation, recording/playback error)
LEDs Above LCD Screen
OVR LED
SPD LED
AUX 1 LED
AUX 2 LED
EXP LED
SYN LED
EXT TC LED
:
:
:
:
:
:
:
Over-range indicator
Tape speed indicator (1, 1/2, 1/4, 1/8, 1/16)
AUX channel 1 signal presence indicator
AUX channel 2 signal presence indicator
Lights when using a channel expansion unit
Lights during synchronous operation
Lights during IRIG-B time code input
Tape transport keys
Mode setting keys
: REC, STOP, FWD, FF, REW, PAUSE
: SHIFT, PNL LOK, SPD/BCM, RANGE, SEARCH, ID/
UTL, OFFSET, OUT/TSG, MRK/SLF, DATA-ANN/P-SV
POWER
BATT
MIC
: Lights when recorder’s power is on
: Lights during battery operation
: Indicates the microphone input level
Key LEDs
Other LEDs
18-6
18-10 Power Supply System
AC (g)
:
Voltage (rated)
100/120 V
220/240 V
Voltage (allowable range)
90 to 132 V
198 to 250 V
50/60 Hz
50/60 Hz
47 to 440 Hz
47 to 66 Hz
Band (rated)
Band (allowable range)
Power consumption (8 ch)
DC (
)
:
160 VA
130 VA
(16 ch)
230 VA
190 VA
Standby power consumption
22 VA
17 VA
Voltage (rated)
12 V
Voltage (allowable range)
Current consumption (8 ch)
(16 ch)
Battery
BP-L60
BP-L90
BP-L60A
BP-L90A
Power supply priority
:
:
:
:
:
11 to 30 V
7.0 A @12V
5.5 A @24V
14.4 V 4.5 Ah
14.4 V 6.7 Ah
14.4 V 5.4 Ah
14.4 V 8.1 Ah
AC > DC > battery
18-11 Dimensions and Mass
Dimensions
Mass
: 340 (W) × 115 (W) × 260 (D) mm (Excluding projections)
: Approx. 7.7 kg (recorder only)
18-12 Operating Environment
Recommended temperature/humidity for operation
: 0 to 40°C, 20 to 80% RH (non-condensation)
(Be sure to warm up the recorder fifteen or more minutes if
it is operated under 5°C.)
Recommended temperature/humidity for storage
: –10 to 50°C, 10 to 90% RH (non-condensation)
Recommended pressure for specifications
: 860 to 1060 hPa
Operating position
: Horizontal (front panel facing forwards)
Vertical (front panel facing upwards)
Vibration resistance
: Under the conditions specified by MIL-STD-810C,
±14.7 m/s2 (±1.5G) (in horizontal position)
Shock resistance
: 392 m/s2 (40 G), 11 ms (while stored)
Polution degree
: II
Over voltage categoly : II
18-7
18-13 Supplied Accessories
AC power cord (100 to 120V, 3P)
AC power cord (220 to 240V, 2P)
Plug adapter (3-pin to 2-pin)
DC power cord
Dynamic microphone
Precision screwdriver
Fuse
Cartridge
Cleaning tape
Filter (dust filter for SIR)
Instruction manual
Inspection sheet
! CAUTION
:
:
:
:
:
:
:
:
:
:
:
:
×1
×1
×1
×1
×1
×1
×1
×1
×1
×2
×1
×1
• This unit is designed and shipped for worldwide use, so that various accessories are
supplied. Use proper accessories according to your area.
• When using a plug adapter (3-pin to 2-pin) for the AC power cord, be sure to connect
the green wire to earth.
18-8
19 Specifications of Optional Accessories
19-1 Battery Pack (BP-L60/L60A/L90/L90A)
Type
: Rechargeable lithium-ion battery
Max. voltage
BP-L60/L60A
BP-L90/L90A
16.6 V
16.6 V
Nominal voltage
14.4 V
14.4 V
Nominal capacity
60 Wh/65 Wh
90 Wh/100 Wh
101×37×169 mm
101×60×169 mm
Approx. 0.9 kg
Approx. 1.3 kg
Dimensions
Mass
Operating temperature range
: –20 to 45°C
Manufacturer
: SONY
19-2 Battery Charger
Power supply
: AC 100 to 240 V, 50/60 Hz
Power consumption
: 160 VA @100 V, 200 VA @240 V (for lithium-ion battery)
Output
: DC 16.8 V, 4.4 A
Charging format
: Constant-voltage constant-current charge control
Operating temperature range
: –20 to 45°C
Dimensions
: 120 (W) × 131 (H) × 330 (D) mm (excluding projections)
Mass
: Approx. 2 kg
Manufacturer
: SONY
19-3 Remote Control Unit (SRM-10)
Tape transport keys
Mode setting keys
Display area keys
Display screen
Confirmation LEDs
:
:
:
:
:
Interface
Cable length
Dimensions
Mass
:
:
:
:
REC, STOP, FWD, FF, REW, PAUSE
ID, RANGE, OFFSET, PNL LOK, 8, PK-CLR, ALL CH, SELECT, LOAD
Same as the recorder
LOADING, BOD, EOD, tape transport keys and mode
setting keys
RS-232C protocol
Approx. 3 m/10 ft
210 (W) × 25 (H) × 70 (D) mm (excluding projections)
Approx. 0.5 kg
19-1
19-4 Channel Expansion Unit (SCX-16W)
Recording/Playback System
Number of channels
Expandability
Bandwidth
: 8 (recorder only)
: 16
:
1/1 (Normal Speed)
SIR-1000W
+
SCX-16W
40 kHz
1/2
1/4
1/8
1/16
20 kHz 10 kHz 5 kHz 2.5 kHz
Speed ratio is the ratio of 1/2, 1/4, 1/8, and 1/16 against the normal speed.
Sampling frequency
: 2.4 × Bandwidth (upper limit frequency of)
AD conversion
: 64-times over-sampling ∆-∑ modulation
DA conversion
: 2 to 128 times over-sampling successive conversion
Quantization
: 16-bit linear quantization
Filters (recording side) : First-order analog filter + FIR digital filter
Filters (playback side) : Seventh-order analog filter + FIR digital filter
Over-range
: ±33 %
Analog characteristics (Input ±133 % within Bandwidth)
AC characteristics
: Bandwidth
2.5 k to 40 kHz
80 k/160 kHz
Frequency response
76 dB or more
74 dB or more
Crosstalk
–76 dB or less
–74 dB or less
Distortion
0.016 % or less
0.02 % or less
Bandwidth
REC
Interchannel
phase
REC + PB
difference
DC characteristics
DC to 40 kHz or less
40 kHz to 160 kHz
Inside a single unit : 1° or less
Between another unit : 2° or less
3°
Inside a single unit : 2° or less
Between another unit : 3° or less
5°
(The same input/output condition. Except sync mode)
: Bandwidth
Each Bandwith
Linearity
Drift
Input
Input format
Connectors
Range
DC offset
Impedance
Withstand voltage
Output
Connectors
Level
Impedance
Applicable load
19-2
+1.0 /–1.5 dB, 0 dB @200 Hz
Dinamic range
±0.1 % or less
REC : ±0.1 % or less /2 hours
PB : ±0.1 % or less /2 hours
(from 15 minutes after power ON)
: Voltage input
: 8 × BNC (single ended)
: ±0.5, ±1, ±2, ±5, ±10, ±20 Vpk
: ±100 %
: ±100 k
: ±100 Vpk
: 8 × BNC (single ended)
: ±1, ±2, ±5, variable (±0.5 to ±5) Vpk
: 50
: 10 k or more
Monitor System
Bar meter
Confirmation LEDs
Power source
Bandwidth
Warning LEDs
: Simultaneous indication for 9 to 16 channels, unidirectional
indicator, percentage and dB indication
: POWER
: 40k, 20k, 10k, 5k, 2.5k
: OVR (over-range for each channel)
Power supply system
Input voltage
Current consumption
: DC 12 V (rated), DC 11 to 30 V (allowable range)
: 4.0 A @12 V
Dimensions and Mass
Dimensions
Mass
: 340 (W) × 65 (H) × 250 (D) mm (excluding projections)
: Approx. 3.5 kg (unit only)
Operating Environment
Recommended temperature/humidity for operation
: 0 to 40°C, 20 to 80% RH (non-condensation)
Recommended temperature/humidity for storage
: –10 to 50°C, 10 to 90% RH (non-condensation)
Recommended pressure for specifications
: 860 to 1060 hPa
Operating position
: Horizontal (front panel facing forwards)
Vertical (front panel facing upwards)
Vibration resistance
: Under the conditions specified by MIL-STD-810C,
±14.7 m/s2 (±1.5G) (in horizontal position)
Shock resistance
: 392 m/s2 (40 G), 11 ms (while stored)
Polution degree
: II
Over voltage categoly : II
Supplied accessories
DC power cable
Expansion cable
Channel expansion board
Combining frame
Hexagonal socket head bolt
Allen wrench
Instruction Manual
Inspection sheet
:
:
:
:
:
:
:
:
1
1
1
4
12
1
1
1
19-3
19-5 Other Options
•
•
•
•
•
•
•
•
•
•
•
•
•
•
Rack Mount Adaptor (SRT-10)
Rack Mount Adaptor (SRT-20)
Shock Mount Adaptor (SSM-10)
Trunk Case (STC-10)
Trunk Case (STC-23)
Bit Stream Board (SBS-10A)
Bit Stream Board (SBS-10S)
Level Converter Box (SBS-LC1)
Adapter for mounting SIR-1000W to rack
Adapter for mounting SCX-16W to rack
Adapter for suppressing large shock level
Trunk case for storing SIR-1000W
Trunk case for storing SIR-1000W and SCX-16W
Board for asynchronous recording bit stream data
Board for synchronous recording bit stream data
Box for converting SBS-10A/S differential input signal
to TTL/bipolar signal
SDX SCSI Emulation Board (STB-10)
Board for SCSI transferring digital data recorded by
SIR-1000W
High-speed SCSI Transmission Board (STB-30)
Board for SCSI transferring digital data recorded by
SIR-1000W at real-time
Data Transfer and Data Display Software (PCscanIII ) Software for digital data transfer and display recorded by
SIR-1000W.
MPEG Video Board (SVB-10)
Board for recording/playing-back the video signal by
SIR-1000W
Synchronization box (SSB-10)
Used for synchronizing the eight SIR’s in maximum AIT
tape streamer drive
AIT Drive (SDX-S300C)
AIT tape streamer drive
For details on the above optional products, refer to the catalogue.
19-4
AMP
CHD4 LSB DIGITAL I/O
CHD1 LSB DIGITAL I/O
CH-8 ANALOG OUTPUT
CH-8 ANALOG INPUT
CH-1 ANALOG OUTPUT
CH-1 ANALOG INPUT
TRIG/REC IN
AUX-1 (DIGITAL)
PHONE
MIC
AMP
CHG
AC/DC
AUX-2 (IRIG-B)
BATT
AC
DC
Oversampling
AD
Analog
LPF
AMP
Serial
I/F
Oversampling
AD
Analog
LPF
Oversampling
AD
Analog
LPF
AMP
ATT
Oversampling
AD
RTC
Analog
LPF
PLL
Clock
GEN
DC/DC
ATT
Serial
I/F
A/D
D/A
A/D
D/A
IRIG
Decoder
PWR
CPU
Select
Interp.
DF
Deci.
DF
Interp.
DF
Deci.
DF
Analog
CPU
Mixer
Bar Meter
CTL
SYNC
DSP
for
Calibration
Buffer
Memory
(FIFO Memory)
Buffer
Manager
and DMA
(CPU)
RS-232C Remocon
MAIN
CPU
Keys
SDX Drive
Program
Memory
(Flash)
Display
Channel
Expansion/Bit Stream
/MPEG VIDEO
Board
OPTION SLOT 2
SCSI
Emulation/Transfer
Board
OPTION SLOT 1
SCSI
CTL
EXT
CTL
20 Block Diagram
20-1
Index
Symbol or Numeric characters
%/dB (digital switch) .......................................... 3-25
; key ..................................................................3-13
: key ..................................................................3-13
8 key .................................................................3-13
9 key .................................................................3-13
3-way power supply system ................................ 1-4
9.6/19.2 (digital switch) ...................................... 3-24
A
AC fuse ............................................................. 3-23
AC IN connector ................................................ 3-23
AC power supply ................................................. 4-1
AC voltage selector switch ................................ 3-23
ADDRESS (address) ......................................... 5-10
Address search ................................................. 10-4
AIT cartridge ........................................................ 1-2
AIT Drive (SDX-S300C) .................................... 19-4
AIT(Advanced Intelligent Tape) technology ......... 1-1
ALL CH key ....................................................... 3-19
Analog channels ................................................ 18-2
Analog channel mode (BCM) .............................. 5-3
Analog data signals ............................................. 5-1
ANALOG INPUT connectors (SCX-16W) .......... 16-2
ANALOG INPUT connectors (SIR-1000W) ....... 3-20
ANALOG MONITOR connector ......................... 3-20
ANALOG OUTPUT connectors (SCX-16W) ...... 16-3
ANALOG OUTPUT connectors (SIR-1000W) ... 3-27
ANN/P-SV key ................................................... 3-14
APD OFF/ON (digital switch) ............................. 3-25
AUX analog channel .......................................... 18-4
AUX analog data .......................................... 8-1, 8-4
AUX digital channel ........................................... 18-3
AUX digital data ............................................ 7-1, 7-2
AUX LEDs (1, 2) ................................................ 3-15
AUX-1 (DIGITAL) IN/OUT ................................. 3-26
AUX-2 (IRIG-B) IN/OUT .................................... 3-26
B
BAND LEDs ....................................................... 16-2
Bar meter area .................................................. 3-16
Bar meters ......................................................... 16-2
BATT LED ........................................................... 3-2
Battery charger .................................................. 19-1
Battery pack ...................................... 4-3, 14-1, 19-1
Battery pack mount ........................................... 3-29
BCM .....................................................................5-3
Bit Stream Board (SBS-10A/S).......................... 19-4
Bit stream data .................................................... 1-2
BOD (Beginning Of Data) .................................... 2-1
BOD LED ............................................................ 3-6
BOT (Beginning Of Tape) .................................... 2-1
C
Calibration ......................................................... 16-7
CAL (calibration) mode ........................................ 4-9
Cartridge compartment ........................................ 3-2
Cartridge cover .................................................... 3-2
Cartridges ..................................... 4-4, 4-5, 4-6, 18-1
CAUTION display area ...................................... 3-17
Channel expansion unit (SCX-16W) ......... 16-1, 19-2
Channel mode LED .................................. 3-20, 3-21
Charging the battery pack on the recorder ........ 14-2
Cleaning tape ...................................................... 4-7
CLOCK key ....................................................... 3-19
COM connector ................................................. 3-26
Combining frames .................................... 16-5, 16-6
Command ................................................. 12-2, 12-4
Compatibility with AIT drive ................................. 1-4
Connecting the Power Supply ............................. 4-1
Connecting the Signals ....................................... 5-1
Control block ..................................................... 3-26
Control functions ................................................. 1-4
D
Data mode setting keys ....................................... 3-7
Data playback............................................. 5-1, 5-12
Data signal system ............................................ 16-7
Data Transfer and Data Display Software (PCscanIII ) .... 19-4
Date recording ..................................................... 5-1
DC circuit breaker ..................................... 3-24, 16-3
DC IN connector (SCX-16W)............................. 16-3
DC IN connector (SIR-1000W) .......................... 3-23
DC power supply ................................................. 4-2
–I–
Dew condensation .............................................
Digital switches ..................................................
Dimensions (SCX-16W) ....................................
Dimensions (SIR-1000W) ..................................
Display keys ......................................................
4-13
3-24
19-3
18-7
3-19
E
Earphone ............................................................. 6-1
Eject (cartridge) ................................................... 2-3
Eject button (battery pack) ................................ 3-29
EJECT button (cartridge) ..................................... 3-3
EMERGENCY EJECT ......................................... 3-3
EOD (End Of Data) ............................................. 2-1
EOD LED ............................................................ 3-6
EOD search ....................................................... 10-3
EOT (End Of Tape) ............................................. 2-1
Error codes ........................................................ 4-10
Error Free Recording ........................................... 1-3
EXP LED ........................................................... 3-15
EXPANSION IN connector ................................ 16-3
EXT TC LED...................................................... 3-15
EXT. CONT connector ...................................... 3-26
External control ................................................. 11-1
F
Fan Control mode .............................................. 4-16
FF key ..................................................................3-5
Filter (Ventilation of slits) ................................... 3-29
Formatting ........................................................... 2-2
Front panel (SCX-16W) ..................................... 16-2
Front panel (SIR-1000W) ........................... 3-1, 18-5
FWD key ............................................................. 3-5
FWD-PAUSE (playback pause) mode ............... 5-13
ID block ............................................................... 2-3
ID display area .................................................. 3-17
ID/UTL key ........................................................ 3-11
ID number ......................................................... 5-10
ID number search .............................................. 10-2
ID search ........................................................... 10-1
Incrementing the ID number .............................. 5-10
INPUT connectors (SIR-1000W) .............. 3-20, 3-21
Interface ................................. 11-1, 11-2, 12-1, 15-2
Input DC offset (OFFSET) ................................... 5-5
Input range (RANGE) .......................................... 5-4
IRIG ON/OFF (digital switch) ............................. 3-25
IRIG-B time code signal ............................... 8-2, 8-3
K
Key LEDs .......................................................... 18-6
L
LCD screen .............................................. 3-15, 18-6
LEDs above LCD screen ................................... 18-6
Left side panel (SCX-16W) ................................ 16-4
Left side panel (SIR-1000W) ............................. 3-29
Level Converter Box (SBS-LC1) ........................ 19-4
LOAD key .......................................................... 3-19
Loading ............................................................... 4-5
LOADING LED .................................................... 3-3
Low DC voltage ................................................. 4-12
LSB Digital Channel ................................... 1-2, 18-3
LSB Digital Channel mode (BCM) ....................... 5-3
LSB Digital Data Signals ..................................... 5-1
LSB DIGITAL INPUT connector ........................ 3-21
LSB DIGITAL OUTPUT connector .................... 3-28
M
G
GROUND terminal (SCX-16W) ......................... 16-3
GROUND terminal (SIR-1000W) ....................... 3-26
Guard frames (SHL-10) ..................................... 13-1
H
High-speed SCSI Transmission Board (STB-30) ..... 19-4
I
ID .......................................................................... 2-1
– II –
Mass (SCX-16W) .............................................. 19-3
Mass (SIR-1000W) ............................................ 18-7
Memory In Cartridge ............................................ 2-2
MIC (Memory In Cartridge) .................................. 2-2
MIC (Microphone) jack ...................................... 3-14
Microphone ......................................................... 6-1
MONI display area ............................................. 3-17
Monitor ....................................................... 5-9, 5-13
Monitor system ......................................... 18-6, 19-3
MPEG Video Board (SVB-10) ........................... 19-4
MRK (Mark) search ........................................... 10-3
MRK/SLF key .................................................... 3-10
MST/SLV (digital switch) ................................... 3-25
O
OFFSET .............................................................. 5-5
OFFSET key........................................................ 3-9
Operation System .............................................. 18-5
Operating environment ............................. 18-7, 19-3
Option slots ....................................................... 3-27
Optional accessories ......................................... 19-1
OUT/TSG key .................................................... 3-10
OUTPUT connectors (SIR-1000W) ................... 3-28
Output level ....................................................... 5-13
Output level adjustment potentiometers (SCX-16W) ... 16-3
Output level adjustment potentiometers (SIR-1000W) ... 3-27
Overwriting data .................................................. 2-3
OVR LED .......................................................... 3-15
P
P-SV (power save) key ...................................... 3-14
PAUSE key ......................................................... 3-5
PHONE jack ...................................................... 3-14
PK-CLR key ....................................................... 3-19
Playback (analog mode) .................................... 16-7
Playback of the Pre-trigger Data ......................... 9-2
POWER LED (SCX-16W) ................................. 16-2
POWER LED (SIR-1000W) ................................. 3-2
Power supply ....................................................... 4-1
Power supply block ........................................... 3-23
Power supply system (SCX-16W) ..................... 19-3
Power supply system (SIR-1000W) ................... 18-7
Power/Drive block ............................................... 3-2
Pre-trigger data ................................................... 9-2
Preventing overwrite ............................................ 4-7
PTRG OFF/ON (digital switch) .......................... 3-24
R
Rack Mount Adaptor (SRT-10) .......................... 19-4
Rack Mount Adaptor (SRT-20) .......................... 19-4
RAL/HLD (digital switch) ................................... 3-24
RANGE ............................................................... 5-4
RANGE display area ......................................... 3-17
RANGE key ......................................................... 3-9
Realtime clock ..................................................... 5-6
Realtime clock search ....................................... 10-4
Rear panel (SCX-16W) ..................................... 16-3
Rear panel (SIR-1000W) .......................... 3-22, 18-5
REC key .............................................................. 3-5
REC-PAUSE (recording pause) .......................... 5-9
Recording (analog mode) .................................. 16-7
Recording data .................................................... 5-8
Recording/Playback error .................................. 4-14
Recording pause ................................................. 5-9
Recording/Playback system ..................... 18-1, 19-2
REMAIN ............................................................ 5-11
Remaining time (REMAIN) display .................... 5-11
REMOTE connector .......................................... 3-26
Remote control unit (SRM-10) ......... 15-1, 15-2, 19-1
REW key ............................................................. 3-6
Right side panel (SCX-16W) ............................. 16-4
Right side panel (SIR-1000W) ........................... 3-30
RS-232C ........................................................... 12-1
S
SCSI Interface ..................................................... 1-4
SDX SCSI Emulation Board (STB-10) ............... 19-4
SELECT key ...................................................... 3-19
Self-check ........................................................... 4-8
Search ................................................................10-1
SEARCH key ..................................................... 3-10
Setting commands .................................... 12-2, 12-4
SHIFT key ........................................................... 3-8
Shock Mount Adaptor (SSM-10) ........................ 19-4
SLF (Self-Check) Mode ....................................... 4-8
Source mode ..................................................... 4-15
SPD ...................................................................... 5-4
SPD LEDs ......................................................... 3-15
SPD/BCM key ..................................................... 3-8
Speaker ............................................................. 3-30
SPEED display area .......................................... 3-17
STAND BY switch ............................................. 3-23
Start ID .................................................................2-1
Start ID search .................................................. 10-2
Status commands ................................... 12-3, 12-10
STOP key ............................................................ 3-5
Stopping and restarting recording ....................... 5-9
Subchannels........................................................ 1-2
Supplied accessories (SCX-16W) ..................... 19-3
Supplied accessories (SIR-1000W) ................... 18-8
Switching the output level .................................. 5-13
– III –
SYN LED ........................................................... 3-15
SYNC connector ................................................ 3-26
Synchronization box (SSB-10) .......................... 19-4
Synchronized operation ....................................... 1-3
Synchronizing mode .......................................... 17-1
Synchronous playback ...................................... 17-6
Synchronous recording ..................................... 17-3
T
Tape format ......................................................... 2-1
Tape mode ........................................................ 4-15
Tape position display area ................................ 3-18
Tape speed (SPD) ............................................... 5-4
Tape transport operation keys ............................. 3-4
Tape transport system ....................................... 18-1
Test signal (TSG) ................................................ 5-7
Time axis conversion ........................................... 1-3
Time axis conversion playback.......................... 5-14
TOC ......................................................................2-2
TOC (Table Of Contents) .................................... 2-1
TRG S/M (digital switch) .................................... 3-24
TRIG/REC IN connector .................................... 3-26
Trigger recording ................................... 1-3, 9-1, 9-2
Trigger signal....................................................... 9-1
Trunk Case (STC-10) ........................................ 19-4
Trunk Case (STC-23) ........................................ 19-4
TSG (Test signal) ................................................ 5-7
V
Ventilation fans (SCX-16W) .............................. 16-4
Ventilation fans (SIR-1000W) ............................ 3-30
Ventilation slits (SCX-16W) ............................... 16-4
Ventilation slits (SIR-1000W)............................. 3-29
Voice annotation .................................. 6-1, 6-2, 18-4
VOL knob .......................................................... 3-14
W
Warning display ................................................. 4-12
– IV –
使用上の注意
本書では下記のような表示を用いています。表示内容をご理解の上、本文をお読み
ください。
! 警告
この表示の注意内容を守らないと、火災や感電などにより死亡や重傷などの人身事
故につながることがあります。
! 注意
この表示の注意内容を守らないと、感電やその他の事故により負傷したり、周辺の
物品に損害を与えたり、機器の機能・性能を損なうことがあります。
参考
機器の正しい取り扱いのため、参考にしていただきたい事項です。
重要
安全のため、使用前には「使用上の注意」をよくお読みになり、必ずお守りくだ
さい。 (本書は、レコーダのバージョン30以降に対応しています。)
設置中や操作中に異常 (煙・音・匂いなど)が発生した場合、すぐに電源コードやバッ
テリパックを外して、サービスにご連絡ください。そのまま使用すると火災や感
電、故障の原因となります。
一般
! 警告
• 本体内部に手を触れないよう、カバーは外さないでください。
• 本体の通風孔などから異物を押し込んだりしないでください。
• 水やその他の液体、またはそれらを含んだ布などを本体の上に置かないでくだ
さい。
• 万一、本体内部に異物や液体を入れてしまった場合は、すぐに電源コードやバッ
テリを抜いて、サービスにご連絡ください。点検・修理の必要があり
ます。
• 本機は室内または同等の条件のもとで使用してください。
• 本体の清掃は乾いた布で行なってください。
i
設置中
! 警告
• 開梱・梱包などの際は、本体を落とさないようにご注意ください。万一落とした
場合は、すぐに電源コードやバッテリパックを外して、サービスにご連絡くださ
い。点検・修理の必要があります。
• 本体は安定した場所にしっかり設置してください。
• 本体内部の過度な温度上昇を防ぐため、通風孔を塞がないでください。
• 電源コードの上には、本体や他の重いものを置かないでください。破損した電源
コードは火災や故障の原因となります。
! 注意
• 本製品はワールドワイドモデルです。使用地域に合った付属品をご使用ください。
• 本体は変圧器・電動機・スピーカなど強い磁気のものから離してください。
• 強い外来ノイズを受けると正しく動作しない場合があります。
• 湿気やほこりの多い場所に置かないでください。
• 直射日光や強い照明光が本体に当たる場所や、熱源の近くに本体を置かないでく
ださい。
• 電源コードや信号ケーブルの抜き差しの際は、コードでなく必ずプラグの部分を
持って行ってください。コードが傷ついて火災や感電の原因となります。
• コード類は人が踏んだり引っかけたりするような場所に置かないでください。
• 付属のAC電源コードはしっかり接続してください。
AC電源コードのグランド用の線は必ず接地してください。
操作中
! 警告
• 規定の電源電圧以外で本体を使用しないでください。火災や感電、故障の原因と
なります。
• 各端子に規定以外の電圧を印加しないでください。
• ヒューズは必ず規定の規格のものと交換してください。
! 注意
• 本体を使用しないときは必ず電源コードやバッテリパックを外しておいてくだ
さい。
• 電源ケーブルを抜いてからヒューズを交換してください。
ii
目次
1
2
3
4
5
概要
............................................................................................................ 1-1
1-1
はじめに ............................................................................................ 1-1
1-2
主な特長 ............................................................................................ 1-2
テープフォーマットと基本動作 ................................................................ 2-1
2-1
テープフォーマット ........................................................................ 2-1
2-2
TOC .................................................................................................... 2-2
2-3
MIC (Memory In Cartridge) ............................................................... 2-2
2-4
フォーマット (FMT) ........................................................................ 2-2
2-5
エジェクト ........................................................................................ 2-3
2-6
重ね書き ............................................................................................ 2-3
2-7
IDブロック ........................................................................................ 2-3
各部の名称と働き ........................................................................................ 3-1
3-1
正面パネル ........................................................................................ 3-1
3-2
背面パネル ...................................................................................... 3-23
3-3
左側面パネル .................................................................................. 3-30
3-4
右側面パネル .................................................................................. 3-31
準備
............................................................................................................ 4-1
4-1
電源の接続 ........................................................................................ 4-1
4-2
カートリッジ .................................................................................... 4-4
4-3
セルフチェック ................................................................................ 4-8
4-4
エラーコード .................................................................................. 4-10
4-5
警告表示 .......................................................................................... 4-12
4-6
ソースモードとテープモード ...................................................... 4-14
4-7
ファンコントロールモード .......................................................... 4-15
データ記録/再生 .......................................................................................... 5-1
5-1
信号系の接続 .................................................................................... 5-1
5-2
記録前の設定 .................................................................................... 5-2
5-3
データ記録 ........................................................................................ 5-8
5-4
データ再生 ...................................................................................... 5-12
6
ボイスメモの記録/再生 .............................................................................. 6-1
7
AUXデジタルデータの記録/再生 .............................................................. 7-1
–1–
8
9
AUXアナログデータの記録/再生 .............................................................. 8-1
8-1
IRIG-Bタイムコード信号の記録/再生 ........................................... 8-2
8-2
AUXアナログデータの記録/再生 ................................................... 8-4
トリガ記録の取扱方法 ................................................................................ 9-1
10 サーチ .......................................................................................................... 10-1
11 EXT.コントロールの取扱方法 ................................................................. 11-1
12 RS-232Cによるコントロール ................................................................. 12-1
12-1
インターフェース仕様 .................................................................. 12-1
12-2
コマンド概要 .................................................................................. 12-2
12-3
コマンド詳細 .................................................................................. 12-4
13 ガードフレームの取扱方法 ...................................................................... 13-1
14 バッテリパックの取扱方法 ...................................................................... 14-1
15 リモートコントロールユニットの取扱方法 .......................................... 15-1
16 チャンネル拡張ユニットの取扱方法 ...................................................... 16-1
16-1
ご使用の前に .................................................................................. 16-1
16-2
各部の名称と働き .......................................................................... 16-2
16-3
本体との接続 .................................................................................. 16-6
16-4
操作方法 .......................................................................................... 16-8
17 同期モードの取扱方法 .............................................................................. 17-1
–2–
17-1
ご使用の前に .................................................................................. 17-1
17-2
接続と設定 ...................................................................................... 17-2
17-3
操作方法 .......................................................................................... 17-3
18 本体仕様 ...................................................................................................... 18-1
18-1 カートリッジ .................................................................................. 18-1
18-2 テープ走行系 .................................................................................. 18-1
18-3 記録/再生方式 ................................................................................. 18-1
18-4 アナログチャンネル ...................................................................... 18-2
18-5 AUXデジタルチャンネル (AUX-1) .............................................. 18-3
18-6 AUXアナログチャンネル (AUX-2) .............................................. 18-4
18-7 ボイスチャンネル .......................................................................... 18-4
18-8 操作系 .............................................................................................. 18-5
18-9 表示系 .............................................................................................. 18-6
18-10 電源系 .............................................................................................. 18-7
18-11 外形寸法・質量 .............................................................................. 18-7
18-12 使用環境 .......................................................................................... 18-7
18-13 標準付属品 ...................................................................................... 18-8
19 オプション付属品の仕様 .......................................................................... 19-1
19-1 バッテリパック (BP-L60/L60A/L90/L90A) .................................. 19-1
19-2 バッテリチャージャ ...................................................................... 19-1
19-3 リモートコントロールユニット(SRM-10) .................................. 19-1
19-4 チャンネル拡張ユニット (SCX-16W) .......................................... 19-2
19-5 その他のオプション ...................................................................... 19-4
20 資料
.......................................................................................................... 20-1
20-1 Block Diagram .................................................................................. 20-1
索引
–3–
1 概要
1-1 はじめに
近年、可聴周波数以上の音響を始めとする超広帯域の計測データを記録/解析すると
いうニーズが各分野で飛躍的に高まっています。しかし、計測目的に対して必要か
つ十分な超広帯域の周波数特性を持ち、可搬性・耐振性・電源の融通性に富んだ
データレコーダは今まで市場での入手が容易ではありませんでした。
SIR-1000Wは、このようなニーズに応える世界最小・最軽量クラスの4 ch×160 kHz
×16 bit超広帯域・高速デジタルデータレコーダ(以下レコーダを呼びます)です。
ソニーが新しく開発したAIT技術を応用、カートリッジ1巻に4 ch×160 kHz分の計測
データをデジタルフォーマットで連続2時間記録します。
さらにチャンネル拡張ユニットSCX-16Wを接続することにより、カートリッジ1巻に
16 ch×40 kHz分の計測データを連続2時間記録でき、用途が一層広がります。
AIT (Advanced Intelligent Tape) 技術:
8 mmテープを用いた高速・大容量のストリーマ (コンピュータデータバックアップ)
新規格で、ソニーの高密度磁気記録技術を活かし、25 GB (非圧縮時) の記憶容量と
24 Mbpsのデータ転送レートを実現しています。
カセットは新開発のAME (Advanced Metal Evaporate) 蒸着テープを用い、出力・信頼
性・耐久性を一段と向上させるとともに、内蔵の16 kbitメモリ (MIC付カセット) に
TOC (Table of Contents) 情報やファイル位置情報を記憶させることにより、データの
検索やアクセスを短時間に行なうことができます。
1-1
1-2 主な特長
アナログ広帯域・多チャンネル
SIR-1000W本体のみで4 ch×160 kHz、本体+チャンネル拡張ユニットの組み合わせ
で16 ch×40 kHzのアナログデータが記録/再生できます。
LSBデジタルチャンネル
1 ch (768 kHz)∼4 ch (192 kHz)のデジタル信号が上記のアナログチャンネルのデータ
と同時に記録/再生できます。
便利なサブチャンネル
本体には上記のアナログチャンネルおよびLSBデジタルチャンネルの他に下記のサブ
チャンネルが常備されており、各種のサブデータをアナログデータと同時に記録/再
生できます。
名称
用途
入出力コネクタ
ボイスチャンネル
メモ音声
正面パネル
AUXアナログチャンネル
IRIG-Bタイムコードなど
背面パネル
AUXデジタルチャンネル
タコパルスなどのバイナリデータ
背面パネル
ビットストリームデータ記録/再生
専用のビットストリームボードをレコーダ背面のオプションスロットに挿入するこ
とにより、標準のAUXデジタルチャンネルとは別に、より高速のビットストリーム
データを記録/再生することができます。アナログデータと同時記録のときのサンプ
リング周波数は12 MHz (1チャンネルモード, 1 ×速度時)、デジタルデータのみ (ア
ナログオフ) のときは24 MHz (同) となります。
ビットストリームボードには、非同期式 (SBS-10A) および同期式 (SBS-10S) があり
ます。
大容量AITカートリッジ
8 mmビデオテープと同一サイズのAITカートリッジ1巻に25 GBものデータを収納で
きます。カートリッジサイズは95×15×62 mm と小さく、保存に場所をとりませ
ん。
新開発のAMEテープはDLC (Diamond-Like Coating) 処理により優れた表面耐久性を
備えていますので、ドロップアウトのきわめて少ないデータ記録が行なえます。
高品位録/再
16 bit直線量子化により、DC∼40 kHzの帯域でダイナミックレンジ 76 dB以上、チャ
ンネル間位相差2度以下を達成しました。なお、アナログ入力レベルは入力レンジ値
の±133%まで許容でき、入力DCオフセットも±100%の範囲内でチャンネルごとに
オートまたはマニュアルで調整することができます。
1-2
時間軸変換
記録/再生のスピードはそれぞれ5段階に選択可能ですので、標準速で記録された160
kHzまでの超音波帯域の音響データを1/16の速度で再生することによって10 kHzまで
の可聴周波数として実際に耳で聴いたり、1/16の速度で記録された最長32時間の10
kHzまでの計測データを標準速で再生することによって大量のデータを高速でホスト
コンピュータに転送したりすることができます。
エラーフリー記録
本機はロータリヘッド方式であり、下図のようにテープ上に斜めのトラックを順次
記録していきます。
またリアルタイム・ベリファイ・アンド・リライト機能により、各トラックの記録
ごとに再生 (ベリファイ) して評価を行ない、もし正しく記録されなかったときは次
のトラックに再書き込み (リライト) を行ないます。そのため、記録中のデータ欠落
をほとんどゼロにすることができ、記録の信頼性を大幅に向上させています。
エラートラック
エラートラック
リライトトラック (NG)
リライトトラック (OK)
リライトトラック (OK)
テープ進行方向
リアルタイム・ベリファイ・アンド・リライト機能
同期運転
本体2台、または本体+拡張ユニット2組の水晶精度の同期運転による記録/再生が行
なえます。周波数帯域またはデータ転送レートを落とすことなく、チャンネル数を
2倍にすることができます。
トリガ記録
本体内部に大容量のデータバッファメモリを内蔵していますので、トリガ信号の前
後のデータを記録することができます。雷や雪崩などの突発現象の記録に便利で
す。
1-3
AITドライブとの互換性
本機で記録したテープはコンピュータデータバックアップ用のAITドライブによって
直接読み出すことができます。コンピュータへのデータ転送とファイリングが一段
と便利に行なえます。
SCSIインターフェース
• 高速SCSIボード (オプション) により、記録時または再生時にデジタルデータをリ
アルタイムでコンピュータに転送可能です。
• SDXエミュレーションボード (オプション) とPCscanIII (オプション) を使用すると
本機をSDXドライブとして使用できます。
多様なコントロール機能
本体はローカル (正面パネル)、専用リモートコントロールユニットSRM-10、外部メ
イク接点およびホストコンピュータからコントロールできます。
3電源方式
本機はAC100/120 V (許容範囲90∼132 V) またはAC220/240 V (許容範囲198∼250 V)、
もしくは外部DC12 V (許容範囲11∼30 V) で作動します。また、本体左側面には専
用のリチウムイオンバッテリパックを取り付けられますので、屋外での使用に便利
です。なお、このバッテリパックは本体に取り付けた状態で充電できます。
電源の優先順位は1AC、2外部DC、3バッテリパックで、ACの停電に対しては外
部DCまたはバッテリパックが、また外部DCの停電に対してはバッテリパックがそれ
ぞれ無瞬断でバックアップします。
イージー・オペレーション
表示が見やすく、操作がわかりやすく、使いやすいことは現場計測機器の条件で
す。本機では使う方の身になったマン・マシン・インターフェースが考慮されてい
ます。
• バックライト付きハイコントラストLCD使用による集中表示画面
• 専用キーによるダイレクトアクセス
小型・軽量
外形寸法は340 (W)×115 (H)×260 (D) mm (本体のみ、突起部含まず)、質量は約7.7 kg
(本体のみ) で、ポータビリティとスペースファクタはこのクラス随一です。
低消費電力
1.6 A@100V AC、7 A@12V DCの低消費電力設計です (本体のみの場合)。
1-4
2 テープフォーマットと基本動作
2-1 テープフォーマット
SIR-1000Wで記録されたテープは、AIT標準の物理および論理フォーマット (ECMA246) に準拠していますが、アプリケーションレベルでは SIR 専用フォーマットと
なっています。その概要を以下に示します。
記録スタート
スタートID
スタートID
ID001
BOT BOD
ID002
ID003
ID004
テープ
ID999
T
O
C
未記録
EOD
IDキーによる
インクリメント
EOT
SIR-1000Wによる記録テープデータ例
BOT (Beginning Of Tape): 物理的に記録可能な最初の位置です。
BOD (Beginning Of Data): ここから最初のデータが記録されます。
EOD (End Of Data)
: 記録がストップされるたびにEODが書かれます。記録を追
加すると前のEODを上書き消去し、最後の記録が終わった
ところに新しいEODが書かれます。EODより先にテープを
送ることはできませんので、データが残っていても読むこ
とはできません。
EOT (End Of Tape)
: 物理的に記録可能な最後の位置です。
IDナンバー
: 各記録ごとにIDブロックが形成され、それぞれにIDナン
バー (001∼999) がつけられます。記録中はIDキーを押すた
びにIDナンバーがインクリメントされます。また、以降の
記録の開始ごと (記録ポーズ解除含む) にも自動的にIDナン
バーがインクリメントされます。IDサーチに利用できま
す。
スタートID
: 記録のスタート点を表わします。実際にはテープに書かれ
ませんが、ここの位置がTOCに登録されます。スタートID
サーチに利用できます。
TOC (Table Of Contents) : すべてのIDブロックの位置情報などをテーブルとして記録
したエリアです。
2-1
2-2 TOC
各記録ブロックのテープ上の位置がIDナンバーとともにTOCに登録され、EODの直前
に記録されています。これによってIDナンバー指定のサーチが可能となります。また
EODからのアペンド (追加) 記録や記録済テープに重ね書き記録をする場合も、TOC
を前もって読む必要があります。なおTOCデータは、MIC付きカートリッジ (後述) の
場合には、テープをローディングするとTOCを読み込み、レコーダ本体内のフラッ
シュメモリ (電源を切っても消えない) にも登録され、このレコーダのことをTOCを
登録したレコーダと呼びます。MIC付きカートリッジをTOCを登録したレコーダに
ローディングすると、テープ上のTOCを読まずに直ちにTOCデータ利用可能状態にな
ります。この反対に、TOCデータ利用可能状態でない場合とは、MIC無しカートリッ
ジでまだテープ上のTOCを読んでいないとき、またはMIC付きカートリッジでIDナン
バーが100を超えていてかつレコーダにTOCが登録されていないときのことをいいま
す。
2-3 MIC (Memory In Cartridge)
カートリッジ内に装着されたフラッシュメモリで、TOCの一部 (IDブロックの総数
100まで) がコピーされます。したがってIDブロックの総数が100までの記録のカート
リッジでは、直ちにTOCデータ利用可能状態になります。IDブロックの総数が100を
超えた記録の場合でも、MICを登録したレコーダにローディングすると直ちにTOC
データ利用可能状態になります。
2-4 フォーマット (FMT)
• SIR-1000Wに異なるフォーマットまたは未フォーマットのカートリッジをローディ
ングすると、LCD画面にFMT?と表示されます。同時にRECキーおよびFWDキーの
LEDが点滅します。このカートリッジをフォーマットする場合には、RECキーを押
しながらFWDキーを押してください。フォーマット中はLCD画面にFMTと表示さ
れます。フォーマットの所要時間は約80秒です。
ブランクカートリッジをローディングすると、LCD画面にTOC?と表示され、FF
LEDが点滅します。その後にFFキーを押すとFMT?が表示されます。
カートリッジのフォーマットは以下のように行なってください。
• フォーマット時に最初のIDナンバーを任意 (000以外) に設定することができます
(デフォルトは001)。
1 LCD画面に FMT? が表示されているときにIDキーを押すと、ID表示部のIDナンバー
が点滅します。;, :, 8, 9の各キーを押して希望のIDナンバーを設定します。
2 RECキーを押しながらFWDキーを押すとフォーマットが開始されます。
3 このテープで記録すると、フォーマット時に設定したIDナンバーからスタート
し順次ナンバーがアップします。
• フォーマット中に、最初のIDナンバーを任意 (000以外) に設定することができます。
1 STOPモード中にRECキーを押しながらREWキーを押します。
2 LCD画面にFMT?と表示され、同時にRECキーおよびFWDキーのLEDが点滅し
ます。
3 RECキーを押しながらFWDキーを押します。
4 テープは自動的にBODに戻って再フォーマットされ、その間LCD画面にはFMT
と表示されます。
2-2
2-5 エジェクト
カートリッジをエジェクトしようとすると、自動的にBOTに戻ってからエジェクト
されます。MIC付カートリッジのときは、テープの途中からエジェクト可能に設定
することができます。
2-6 重ね書き
記録済みのテープに重ね書きをすることができます。この場合は新しい記録の終了点に
EODが書かれるので、そのあと旧データが残っていても、そのデータは再生されませ
ん。記録済みテープに重ね書きする場合は注意してください。IDナンバー003の途中か
ら重ね書きしたテープの例を下図に示します。
スタートID
スタートID
ID001
ID002
ID003
テープ
ID004
ID100
BOT BOD
T
O
C
未記録
EOD
EOT
例:重ね書き前の状態
新たな記録スタート
ID001
ID002
BOT BOD
ID003
再生不可
T
O
C
ID004
記録ストップ
テープ
未記録
EOD
EOT
例:ID003に重ね書き後の状態
新たな記録スタート
再生不可
T
ID001 O
C
BOT BOD
テープ
未記録
EOT
EOD
例:BODから重ね書き後の状態
2-7 IDブロック
各IDブロックは、1個以上のレコードという約550キロバイトのセグメントからなっ
ています。したがってIDブロックの最小長さは1レコードです。標準速 (1×) で約170
ミリ秒、1/16速では約2.7秒となります。
2-3
3 各部の名称と働き
3-1 正面パネル
電源/ドライブ部
データモード設定キーエリア
LCD画面
ディスプレイキーエリア
POWER
BATT
SPD/BCM
dB
Advanced
Intelligent
Tape
%
OVR 1 1/2 1/4 1/8 1/16 1 2
SPD
AUX
–6
FF EOD
FWD
STOP
RANGE
M
MONI
REC
OVR
PAUSE
CH
RANGE
SPEED
CH
V X1/
S- TIME
ADDRESS REMAIN T - T I M E
Y
M
D
H
M
S
0
-40 -100
REW
(CH)
CAUTION
OVR
-20
BOD
ID
+2
+100
0
LOADING
EJECT
EXT TC
EXP SYN
1-4 5-8
S I R -1000W
M
A
SEARCH
OUT/TSG
(UNIT)
ID/UTL
MRK/SLF
SHIFT
PNL LOK
9-12 13-16
PK-CLR
OFFSET
A
DATA
ALL CH SELECT
LOAD
CLOCK
VOL
PHONE
MIC
ANN/P-SV
INSTRUMENTATION DIGITAL DATA RECORDER
ANALOG
INPUT
≤ ± 100vpk
1
2
3
100k
4
5
6
7
8
LSB DIGITAL
INPUT
≤ ± 10vpk 10k
D1
D2
D3
D4
ANALOG
MONITOR
REF
テープ走行キーエリア
アナログ入力部
LSBデジタル入力部
3-1
電源/ドライブ部
2
1
POWER
BATT
Advanced
Intelligent
Tape
3, 4
5
LOADING
EJECT
BOD
REW
FF EOD
FWD
STOP
REC
PAUSE
6
1 POWER LED
レコーダの電源がONのとき点灯します。
なお、レコーダの電源がOFFのときはすべてのLEDおよびLCDが消灯します。
2 BATT LED
レコーダ左側面に取り付けられたバッテリパックを電源として作動するとき点
灯します。
また、バッテリパックを充電中は点滅し、充電が完了すると消灯します。
バッテリ充電中に異常が起こると急速点滅します。バッテリをいったん外し、再
度装着してください。それでも直らないときは、バッテリを交換してください。
3 カートリッジ蓋
テープ走行系を埃などから保護するための蓋です。
開けるときは右上の指かけを指先で手前に引き、閉めるときは蓋の上部を指先
で向こう側に押します。
! 注意
• 使用する際は必ず閉めてご使用ください。
• 透明な窓の部分を押さないでください。
参考
本機はカートリッジ蓋の破損防止のため、開けた状態で上から大きな力で押す
とカートリッジ蓋が本体から外れるようになっています。外れたときは、カー
トリッジ蓋の左右のピンを片方ずつ本体の軸受部分にはめ直してください。
3-2
4 カートリッジ挿入口
AITカートリッジを挿入するところです。
途中まで挿入すると自動的にローディングされます。
! 注意
• カートリッジ挿入口のフィルムは、テープ走行部への埃の侵入を防ぐためのも
のです。剥がさないでください。
• 挿入のときに強く押しすぎると故障の原因となります。
5 LOADING LED
テープがカートリッジから引き出され、テープ走行が可能な状態になったとき
点灯します。
カートリッジがローディング中またはアンローディング中は点滅します。
カートリッジがレコーダ内にないときは消灯します。
ローディング時にLOADING LEDが点滅しないときは、いったんエジェクトして
から再度ローディングしてください。
参考
MIC無しカートリッジの場合、MIC付きカートリッジよりもローディング/アン
ローディングに時間が長くかかることがあります。
6 EJECTボタン
カートリッジをレコーダ内から取り出すときに押します。
EMERGENCY EJECT
EJECTボタンを押して、数分たってもカートリッジが取り出せない場合は、次
の手順で取り出すことができます。
1) STAND BYスイッチをOFFにします。
LCD画面表示が消えます。
2) STAND BYスイッチをONにします。
LCD画面にLOAD/WAITが交互に表示されます。
3) このメッセージが表示されている数秒間のうちにEJECTボタンを2回以上押し
てください。LCD画面表示がUNLD/WAITに替わりカートリッジがエジェク
トされます。
注意:
この方法でエジェクトされたカートリッジはダメージを受けている場合があり
ます。また、この操作を行なっても取り出せない場合は、サービスに相談して
ください。
3-3
テープ走行キーエリア
各走行モードで動作中は各キー上のLEDが点灯します。
POWER
BATT
Advanced
Intelligent
Tape
!™
LOADING
EJECT
!¢
BOD
REW
FF EOD
≤ ± 100vpk
!£
!¡
0
INPUT
1
2
FWD
STOP
REC
PAUSE
100k
3
4
5
6
7
7
8
9
8
9
REF
テープ走行モードの遷移
現在のテープ走行モードに対し、次に押されるキーによって開始されるテープ走行
モードは下表の通りです。なお、“―”はモード不変を示します。
次に押されるキー
EJECT STOP REC REC+PAUSE
カートリッジ無し
PAUSE
FWD
FF/REW
E-E
―
―
―
―
―
―
STOP
―
E-E
STOP
STOP
―
―
―
STOP
EJECT
―
E-E
REC-PAUSE
REC
FWD-PAUSE FWD
―
REC-PAUSE
REC
REC-PAUSE
―
―
―
―
REC
REC
―
―
―
E-E
現
在
の
モ
ー カートリッジ有り
ド
REC+
FWD
REC-PAUSE
―
EJECT STOP
―
STOP
E-E
E-E
FF/REW
REC
―
STOP
―
REC-PAUSE
―
REC-PAUSE
―
FWD-PAUSE
―
STOP
―
―
―
FWD
FWD
―
FWD
―
STOP
―
―
―
FWD-PAUSE
―
IDサーチ
FF
―
STOP
―
―
―
―
―
―
REW
―
STOP
―
―
―
―
―
―
SEARCH
―
STOP
―
―
―
―
―
スタートIDサーチ
SLF
―
STOP
―
―
―
―
―
―
参考
走行モードの遷移中、例えばRECモードからSTOPモードへ移るときはSTOPキー上
のLEDが点滅します。この間は他のキー操作を受けつけません。また、背面の
STAND BYスイッチをOFFしてもすぐに電源が切れないことがあります。
3-4
7 PAUSEキー
PAUSE (ポーズ) モードにするときに押します。
PAUSEモードにはREC-PAUSE (記録ポーズ) モードとFWD-PAUSE (再生ポーズ)
モードがあります。
REC-PAUSEモードでは入力データの最初の部分がレコーダのFIFOメモリに蓄
えられますので、ポーズ解除と同時にデータを記録することができます。
また、FWD-PAUSEモードでは再生データの最初の部分がFIFOメモリに蓄えら
れますので、ポーズ解除と同時に再生信号を出力することができます。
参考
RECモードからREC-PAUSEモードに入るとき、アドレスの時間表示が2秒未満の場
合はREC-PAUSEモードに入れないことがあります。
8 RECキー
• このキーのみ押すとE-Eモードになります。
E-Eモードでは入力信号が記録系から直接再生系に出力されます。テープを走
行させずに入力信号のレベル確認や入力レンジ・入力DCオフセットの設定が
行なえます。
• このキーを押しながらFWDキーを押すとREC (記録) モードになります。REC
モードでは入力信号がテープ上に記録されます。
9 STOPキー
STOP (停止) モードにするときに押します。
STOPモードではすべてのモードが停止されます。
参考
• 本機では記録データをいったんレコーダのFIFOメモリに蓄えてからテープに
記録しますので、STOPキーを押してから最大20秒間はテープ走行が停止しな
い場合があります。
• STOPキーが押されてからテープが実際に停止するまでは、STOPキーのLEDが
点滅します。
• FFまたはREW中にSTOPキーを押すと、テープはSTOPキーの押された位置で
停止します。
0 FWDキー
FWD (再生) モードにするときに押します。FWDモードではテープ上のデータが
再生されます。
!¡ FFキー
• FF (早送り) モードにするときに押します。
FFモードではテープが高速 (標準速の約75倍) でEOD方向に送られます。
• サーチモードでこのキーを押すと、次のスタートIDをサーチします。
• FWD中にこのキーを押すと、次のIDナンバーの先頭にスキップします。
3-5
!™ EOD LED
EODの位置にテープがあるときに点灯します。
EODとはテープ上に記録されたデータの終端を意味します。
参考
• 記録を終了すると、テープのその場所にEODが書かれ、EOD LEDが点灯します。
• EODから記録を開始する場合は、記録を開始してからEOD LEDが消灯するこ
とを確認してください(標準速では約5秒以内)。
• FWDモードおよびFFモードのときは、EODで自動的にテープ走行が停止します。
!£ REWキー
• REW (巻戻し) モードにするときに押します。
REWモードではテープが高速 (標準速の約75倍) でBOD方向に送られます。
• サーチモードでこのキーを押すと、現在の記録ブロックのスタートIDをサー
チします。
• FWD中にこのキーを押すと、現在のIDナンバーの先頭に戻ります。
!¢ BOD LED
BODの位置にテープがあるときに点灯します。
BODとはテープ上に記録されたデータの先頭を意味します。
参考
REWモードのときはBODで自動的にテープ走行が停止します。
3-6
データモード設定キーエリア
!•
@£
SPD/BCM
!§
!¶
@¢
(CH)
RANGE
M
OFFSET
A
@¡
@™
M
@∞
A
SEARCH
OUT/TSG
(UNIT)
ID/UTL
MRK/SLF
SHIFT
@§
!∞
PNL LOK
DATA
!ª
VOL
PHONE
@º
MIC
ANN/P-SV
@¶
@•
@ª 14
15
16
MONITOR
#º
各種設定モードの遷移
現在のモードにおいて有効なモード設定キーは下表の通りです。なお、“―”は
モード不変を示します。
モード設定キー
現
在
の
モ
ー
ド
SPD/BCM
RANGE, OFFSET
STOP
○
○
○
×
E-E
○
○
○
○
REC-PAUSE
○
○
○
○
OUT TSG
SEARCH
ID
UTL
MRK
SLF
○
×
○
×
○
×
×
×
×
×
×
×
×
×
×
×
○
(マーク設定)
×
REC
×
○
○
○
×
○
(IDインクリメント)
FWD
×
×
○
×
×
×
×
○
(マーク設定)
×
FF
×
×
×
×
×
×
×
×
×
REW
×
×
×
×
×
×
×
×
×
SEARCH
×
×
×
×
―
○
(ID設定)
×
○
(マークサーチ開始)
×
SLF
×
×
×
×
×
×
×
×
―
3-7
!∞ SHIFTキー
• このキーを押すとSHIFT (シフト) モードとなり、キー左上のLEDが点灯します。
同時に下記の各キー右上のLEDが点滅し、表記の右側の機能を選択できます。
SPD/BCMキー
OUT/TSGキー
MRK/SLFキー
ID/UTLキー
RANGEキー
OFFSETキー
ANN/P-SVキー
<例1>
SPD/BCMキーのみ押すとSPDキーとしての機能、SHIFTキーを押してから
SPD/BCMキーを押すとBCMキーとしての機能になります。
<例2>
RANGEキーのみ押すとM-RANGE (マニュアルレンジ設定) モード、SHIFT
キーを押してからRANGEキーを押すとA-RANGE (オートレンジ設定) モード
になります。
• このキーを続けて2秒以上押すとPNL LOK (パネルロック) モードとなり、PNL
LOK LEDが点灯します。正面パネル上の全てのキーが無効となります。
PNL LOKモードを解除するときはこのキーを続けて2秒以上押します。
!§ SPD/BCMキー
• このキーのみ押すとSPD (テープ速度設定) モードとなり、キー左上のLEDが
点滅します。
同時に選択されているSPD LED (1, 1/2, 1/4, 1/8, 1/16) が点灯します。
テープ速度の選択は/キーまたは-キーによって行ないます。
再度SPD/BCMキーを押すとSPDモードが終了します。
• SHIFTキーを押してからこのキーを1回押すとBCM (アナログチャンネルモー
ド設定) モードとなり、キー右上のLEDが点滅します。
このとき/キーまたは-キーによってアナログチャンネルモードの選択を行
ないます。
SHIFTキーを押してからこのキーを1秒以内に2回押すとBCM (デジタルチャン
ネル設定) モードとなり、キー右上のLEDが点滅します。
このとき/キーまたは-キーによってデジタルチャンネルモードの選択を行
ないます。
再度SPD/BCMキーを押すとBCMモードが終了します。
3-8
!¶ RANGEキー
RANGE (レンジ設定) モードにするときに押します。
RANGEモードでは記録アンプの入力レンジをチャンネルごとに設定することが
できます。
レンジ値 ±0.5 Vpk, ±1 Vpk, ±2 Vpk, ±5 Vpk, ±10 Vpk, ±20 Vpk
RANGEモードにはM-RANGE (マニュアルレンジ設定) モードとA-RANGE (オー
トレンジ) 設定モードがあります。
• このキーのみ押すとM-RANGE (マニュアルレンジ設定) モードとなり、キー
左上のM LEDが点滅します。
同時にLCD画面上で設定対象チャンネルのレンジ値が点滅します。
レンジ値の選択は8キーまたは9キーによって行ないます。
設定対象チャンネルの切換は;キーまたは:キーによって行ないます。
参考
不要なDC成分が含まれる入力信号に対して最適な入力レンジ設定をするには、前
もって入力DCオフセットの設定をすることをおすすめします。
• SHIFTキーを押してからこのキーを押すとA-RANGE (オートレンジ設定) モー
ドとなり、キー右上のA LEDが点滅します。
A-RANGEモードでは、入力信号のレベルに応じて自動的に各チャンネルのレ
ンジ設定を行ないます。再度このキーを押すと、これに応じて各チャンネルご
とのレンジ設定が確定します。
!• OFFSETキー
OFFSET (オフセット設定) モードにするときに押します。
OFFSETモードでは記録される入力信号に対してDCオフセット電圧を加えること
によってレベルをシフトできます。これにより、入力信号に含まれる記録不要の
DC成分をキャンセルし、分解能を上げることができます。DCオフセット値は
チャンネルごとに設定できます。
オフセット値 ±100%, 1%きざみ
OFFSETモードにはM-OFFSET (マニュアルオフセット設定) モードとA-OFFSET
(オートオフセット設定) モードがあります。
• このキーのみ押すとM-OFFSET (マニュアルオフセット設定) モードとなり、
キー左上のM LEDが点滅します。
同時にLCD画面上で設定対象チャンネルのオフセット値 (テープ位置表示エリ
アの上4桁) が点滅します。
オフセット値の設定は8キーまたは9キーによって行ないます。
設定対象チャンネルの切換は;キーまたは:キーによって行ないます。
• SHIFTキーを押してからこのキーを押すとA-OFFSET (オートオフセット設定)
モードとなり、キー右上のA LEDが点滅します。
A-OFFSETモードでは、検出された入力信号の最大値および最小値から自動的
にDC成分を算出し、DCオフセット値を設定します。
再度このキーを押すと、DCオフセット値が確定され、A-OFFSETモードから
抜けます。
3-9
!ª OUT/TSGキー
このキーのみ押すとOUT (出力レベル設定) モードとなり、キー左上のLEDが点
滅します。
同時にLCD画面上で設定対象チャンネルの出力レベル値が点滅します。
OUTモードでは再生アンプの出力レベルをチャンネルごとに切り換えることが
できます。
出力レベル値
±1 Vpk, ±2 Vpk, ±5 Vpk,マニュアル (連続可変)
出力レベル値の選択は8キーまたは9キーによって行ないます。マニュアルの場
合は背面の出力レベル調整ボリウムで調整します。
設定対象チャンネルの切換は;キーまたは:キーによって行ないます。
参考
マニュアルポジションのときはLCD画面上のRANGE表示エリアは“−−”とな
ります。
• SHIFTキーを押してからこのキーを押すとTSG (テスト信号) モードとなり、
キー右上のLEDが点滅します。
同時にLCD画面上にテスト信号の種類が表示されます。
TSGモードでは全チャンネルに対して規定のテスト信号が入力されます。
テスト信号
AC ±100%, DC +100%, DC -100%, 0 V, EXT
テスト信号の選択は;キーまたは:キーによって行ないます。
EXTの場合は、レコーダ本体のCH 1への入力信号がCH 1∼CH 8に対するテス
ト信号となります。また、チャンネル拡張ユニットのCH 9への入力信号はCH
9∼CH 16に対するテスト信号となります。LCD画面上ではEXTの文字が表示
されます。
@º MRK/SLFキー
• RECまたはFWDモード中にこのキーを押すとMRK (マーク設定) モードとな
り、キー左上のLEDが一瞬点灯します。
押したときのテープポジションが記憶され、カートリッジが入っている間は次
にこのキーを押すまで保存されます。
• SHIFTキーを押してからこのキーを押すとSLF (セルフチェック) モードとな
り、キー右上のLEDが点滅し、同時にLCD画面上にSLFと表示されます。
SLFモードではレコーダが自動的に所定のテストプログラムを実行し、異常の
有無をチェックします。
セルフチェック項目 録/再ヘッド, アンプ・テープ走行系
• SHIFTキーを押してからこのキーを1秒以内に続けて2回押すとCAL (キャリブ
レーション) モードになり、同時にLCD画面上にCALと表示されます。
CAL項目
3-10
DCオフセット, ゲインエラー補正
@¡ SEARCHキー
このキーを押すとSEARCH (サーチ) モードとなり、キー左上のLEDが点滅します。
同時にID/UTL, MARK/SLF, FF, REWの各キーのLEDが点滅します。これらのう
ち、次に押すキーによって下記のサーチモードを選択できます。
(1) ID/UTLキー
: IDサーチ
(2) MRK/SLFキー : マークサーチ
(3) FFキー
: 正方向スタートIDサーチ
(4) REWキー
: 逆方向スタートIDサーチ
各サーチモードによるサーチ中はSEARCH LEDが点滅し、ターゲットをサーチ
できたときは消灯し、できなかったときは点滅を続けます。サーチできたとき
はターゲットの位置で停止します。
@™ ID/UTLキー
• このキーをRECモード中に押すと、IDナンバー数値が1つずつ増加します。記
録の内容によってIDナンバーを変えることができます。
• このキーをSCH (サーチ) モード中に押すとIDサーチモードになり、設定され
たIDナンバーをターゲットにサーチを行ないます。
IDナンバー数値の増減は8キーまたは9キーによって行ないます。
IDナンバーの桁移動は;キーまたは:キーによって行ないます。
• SHIFTキーを押してからこのキーを押すとUTL (ユーティリティ設定) モード
になり、同時にLCD画面上にAT FMTと表示されます。
ユーティリティ機能の選択は8, 9で行ないます
機能および
LCD画面表示
内容
: フォーマットされていないテープを認識す
ると自動的にフォーマットを開始します。
OFF : FMT?と表示され自動的にフォーマットされ
ません。
工場出荷時
AT
FMT
ON
ERA
ON : 記録されているテープへ上書きできます。
OFF : ERA OFFと表示され、上書きできません。
ON
SYNC
ID01
同期運転のスレーブ機に設定されているときに表示
され、SYNC IDを設定します。
01
DEW
ON
: 結露の有無を検出します。(待機時間 : 約3分)
OFF : 結露の有無を検出しません。(待機時間 : なし)
BOT
EJCT
SKP
ET03
CMP
MODE
: テープ途中でのエジェクトはできません。
BOTに巻き戻した後エジェクトします。
再度ローディングすると、エジェクトした
位置でテープは停止します。
OFF : テープの途中でもエジェクト可能です。
(MIC付カートリッジで有効。)
OFF
OFF
ON
: ET03エラー発生時、自動的にその部分をス
キップして再生を再開します。この間、約
30秒信号が出ません。
OFF : ET03エラー発生時、再生を中止します。
STOPキーを押した後エジェクトしてくださ
い。
ON
ON
ON : 圧縮モードが有効になります。
OFF : 圧縮モードが無効になります。
(非圧縮モード)
OFF
ON
機能を選択したあとに、;, :キーで機能のON/OFFおよびSYNC IDを選択し
ます。機能が選択される (ONになる) と√マークが文字列の先頭に表示され、
ID/UTLキーを押すとユーティリティ機能が有効になります。
3-11
参考
• 設定中にSTOPキーを押すと、設定内容はキャンセルされます。
• 機能に関する補足
ERA
ERA機能がOFFの状態でテープに上書きをすると、LCD画面上にERA OFFと
表示されRECモードに入りません。
DEW
DEW機能がONの状態でSTAND BY スイッチをONにすると、結露検出のため
約3分間の待機時間が必要となります。終了までの時間はLCD画面に表示され
ます。
BOT EJECT
BOT EJECT 機能はMIC付きカセットのみで有効です。同一テープの使用頻
度が高い場合は、ONにしてご使用になることをおすすめします。OFFにし
て同一箇所でテープのローディング/エジェクトが繰り返されると、その部
分のデータにダメージ (再生できない) を与える場合があります。
なお、MIC無しカセットではすべてBOTに巻き戻した後、エジェクトされま
す。
SKP ET03
SKP ET03 機能がONのときで同期運転の場合は、スキップの時点で同期が
はずれます。OFFのときにET03が表示されて停止した場合は、EJECTキーの
み受け付けます。
CMP MODE
CMP MODE をONにしてデータを圧縮することにより、テープとメモリ間
のデータ転送が早くなり、メモリのオーバーフローやアンダーフローになる
までの猶予が大きくなるため、
マークが起こりにくくなります。
(圧縮可能データの場合、テープの使用量が少なくなるためリトライが少な
いと記録時間も延びます。リトライについては4-5警告表示の項「
記録/
再生エラー」を参照してください。)
ON (圧縮モード) の場合は、RECキーを押すとLCD画面上に約0.5秒間CMP
と表示されます。
なお、CMP MODE設定のないレコーダでも CMP MODE ONで記録された
テープを再生可能です。
! 注意
• DEW機能がOFFの場合は、結露検出を行なわないためテープを破損するお
それがあります。
• 5℃未満の環境で使用する場合は、必ずDEW機能をONにして使用してくだ
さい。
• CMP MODEはテープがロードされているときのみON/OFF切り換え可能です。
• SBS-10A/S (非同期式ビットストリームボード) や SVB-10 (MPEGビデオボー
ド) をご使用になる場合、CMP MODEは自動的にOFF (非圧縮モード) にな
ります。
• CMP MODE時のREMAIN値は目安となります。(データにより圧縮率が異な
るため)
3-12
@£ /キー
• このキーを押すと、LCD画面上で点滅しているチャンネルまたは数値桁が左方
向に一つずつ送られます。
• モニタチャンネルを小さいNo.の方向に送るとき、テスト信号の種類を選択す
るとき、テープ速度を上げるとき、およびチャンネルモードを設定するときに
もこのキーを使います。
@¢ -キー
• このキーを押すと、LCD画面上で点滅しているチャンネルまたは数値桁が右方
向に一つずつ送られます。
• モニタチャンネルを大きいNo.の方向に送るとき、テスト信号の種類を選択す
るとき、テープ速度を下げるとき、およびチャンネルモードを設定するときに
もこのキーを使います。
@∞ 8キー
• このキーを押すと、LCD画面上で点滅しているチャンネルまたは数値桁の設定
値が一段階ずつ増加します。
• 8キーまたは9キーを押すごとにモニタされるレコーダ本体またはチャンネル
拡張ユニットが選択できます。
チャンネルモードを選択するときもこのキーを押します。
参考
全チャンネルを同一に設定したいときは、ALL CHキーを押してください。
@§ 9キー
このキーのみ押すとLCD画面上で点滅しているチャンネルまたは数値桁の設定
値が一段階ずつ減少します。
参考
• 8キーと9キーを同時に2秒間押し続けると、各設定値が下記の値にセットさ
れます。セットするときはSTOPモードで行なってください。
このときDATA、ANN/P-SVキーの設定はANN/P-SVになります。
1)チャンネルモード
: 2 ch, 4 ch, 8 ch, 16 chのうち使用可能な最大値
2)テープ速度
: 1 (標準速)
3)入力レンジ
: ±1 Vpk
4)入力DCオフセット
: 0%
5)出力レベル
: ±1 Vpk
6)モニタチャンネル
: CH 1
7)LSBデジタルチャンネル
: OFF
• 全チャンネルを同一に設定したいときは、ALL CHキーを押してください。
3-13
@¶ ANN/P-SVキー
• このキーを押すごとに、スピーカまたはイヤホンの再生信号源がボイスメモと
アナログデータ信号とに切り替わります。
ANN LEDが点灯中は、ボイスチャンネルに記録されたメモ音声がスピーカま
たはイヤホンから出力されます。
DATA LEDが点灯中は、モニタされているアナログチャンネルのデータ信号
がスピーカまたはイヤホンから音声で出力されます。
• SHIFTキーを押してからこのキーを押すとP-SV (パワーセーブ) モードとな
り、キー右上のLEDが点灯します。
記録中のアナログ再生回路系およびLCDのバックライトをOFFし、レコーダの
消費電力を節減することができます。
P-SVモードを解除するときもSHIFTキーを押してからこのキーを押します。
• SHIFTキーを押してからこのキーを3秒以上押すと、ファンコントロールモー
ドになります。SIR-1000WおよびSCX-16Wの機内温度が低いとき、RECモー
ド中に冷却ファンの回転を停止させることができますので、静粛性が要求され
る音響計測などに便利です。ファンコントロールモード中はANN/P-SVキー右
上のLEDが点滅するとともに、LCD画面のテープ位置表示エリア右端に矩形
マークが表示されます。
ファンコントロールモードから抜けるときは、SHIFTキーを押してからこの
キーを3秒以上押します。詳細は、4-7項を参照してください。
! 注意
パワーセーブ(ファンコントロール)モード解除時に、1ms以下のノイズが発
生しテープに記録される場合があります。
ストップモード中にパワーセーブモードの切替(ON/OFF)を行なうことによ
り、上記現象を回避できます。
また、ファンコントロールモードが自動解除される前に記録を停止することに
より、上記現象を回避できます。
@• MICジャック
付属のマイクロホンのプラグをここに差し込んで使います。
音声入力に応じて右上のLEDが点灯します。
@ª VOLつまみ
スピーカまたはイヤホンの再生音量を調整するときに使います。
参考
警告メッセージに伴なう警告音の音量も調整されます。
#º PHONEジャック
市販のミニプラグ付きイヤホンのプラグをここに差し込んで使います。
3-14
LCD画面
#¢
#∞
#•
#£
#™
#¡
dB
%
OVR 1 1/2 1/4 1/8 1/16 1 2
SPD
AUX
EXT TC
EXP SYN
ID
#ª
OVR
+2
+100
0
#¶
MONI
–6
SPEED
V X1/
S- TIME
ADDRESS REMAIN T - T I M E
Y
M
D
H
M
S
0
RANGE
CH
-20
-40 -100
OVR
CH
#§
CAUTION
1-4 5-8
S I R -1000W
$™
$£
9-12 13-16
PK-CLR
ALL CH SELECT
LOAD
CLOCK
$¡
$º
#¡ OVR LED
E-E, REC-PAUSE, REC, FWDの各モードにおいて、いずれかのチャンネルの信
号レベルがオーバーレンジとなったときに点灯します。
#™ SPD LED
レコーダ本体に設定されたテープ速度を表示します。選択されている速度 (1,
1/2, 1/4, 1/8, 1/16) のLEDが点灯します。
#£ AUX LED (1, 2)
• AUX-1 (DIGITAL) INコネクタに信号 (TTLレベル) が入力されているとき、ま
たは記録された信号を再生しているときは1 LEDが点灯します。
• AUX-2 (IRIG-B) INコネクタに信号 (±0.2 Vpk以上) が入力されているときは
2 LEDが点灯します。
#¢ EXP LED
チャンネル拡張ユニットが接続され、かつチャンネルモードによって有効なと
き (16 chモード) に点灯します。
#∞ SYN LED
2台以上のレコーダが同期モードで作動中、各レコーダの状態に応じて点灯また
は点滅します。
#§ EXT TC LED
外部タイムコードゼネレータから入力されたIRIG-Bタイムコード信号が正しく
検知されているとき、またはテープ上に記録されたIRIG-Bタイムコード信号が
再生されているときに点灯します。
3-15
#¶ バーメータエリア
チャンネルごとのアナログデータ信号レベルを表示する部分です。
目的に応じて%スケールとdBスケールとに切り換えられます。
• %スケールとdBスケールとの切り換えは背面パネルのデジタルスイッチで行な
います。
• %スケールでは両振れ式で表示されます。0%レベルを中心に信号の極性に応
じて上方向 (+) または下方向 (−) に振れます。データ信号に直流成分が含ま
れる応力・歪・加速度などの計測に適します。
• dBスケールでは片振れ式で表示されます。信号の極性にかかわらず基準レベ
ル (0 dB) に対する相対値 (+2 dB, −6 dB, −20 dBなど) で表示されます。デー
タ信号に直流成分が含まれない音響関係の計測に適します。
• オーバーレンジとなったチャンネルに対応してOVRマークが点灯します。%ス
ケールでは信号の極性に応じて+側・−側または両側が点灯します。
• バーメータ応答特性のリアルタイムとピークホールドとの切り換えは背面パネ
ルのデジタルスイッチで行ないます。
• 文字による各種のメッセージもここに表示されます。
メッセージ一覧
表示
CBUF 70∼100
CHNG TAPE
CMP
DATA CLAR
DRIV BUSY
EOD WRT
EOD WRT, WAIT
EOT
ERA? FMT
FMT? HEAD CLEN
HI T WAIT
LOAD OK? LOAD WAIT
LO T WAIT
RWD WAIT
SLF
SLF EOT
SLF NG
SONY V**
SRCH BOD
STB 10
STB 30
TOC READ
TOC? UNLD WAIT
WARM WAIT
600S∼000S
3-16
状態
記録中にバッファの使用領域が70%を超えた
(塵埃等により再書き込みの回数増加)
TAPE交換要求
圧縮モード
バッファ内のデータをテープに書込み中
REWキーを押した後ドライブが動き始めるまでの待ち時間
TOC, EOD書き込み中
REC中にPOWER OFFした場合の再復帰後のTOC書き込み中
テープがEOTの位置にいる
データを上書きするかの問い合わせ
*YESならREC-FWDキーを、NOならSTOPキーを押す。
フォーマット中
フォーマットするかの問い合わせ
*YESならREC-FWDキーを、NOならSTOPキーを押す。
クリーニングカセットでのヘッドクリーニング要求
内部温度が50℃以下になるまで待機中
テープの条件にレコーダを設定するかの問い合わせ
*YESならLOADキーを、NOならSTOPキーを押す。
テープローディング中
内部温度が5℃以上になるまで待機中
カートリッジをBODにREW中
セルフチェック中
EOTまで記録されているテープのためセルフチェック不可
セルフチェックNG
*テープを換えるか、ヘッドクリーニングする。
レコーダのバージョン表示
BODサーチ中
STB-10モード (ストリーマドライブ用途のとき)
STB-30モード (高速データ転送用途のとき)
TOC読込み中
TOCを読込むかの問い合わせ
*YESならFFキーを、NOならSTOPキーを押す。
アンローディング中
結露を検出、ウォームアップ中
結露検出または結露解除までの時間 (秒)
#• ID表示エリア
IDナンバー (ソースデータ/テープデータ) が表示されます。
走行モードとソースデータ (レコーダ内部の設定値) またはテープデータ (テー
プ上に記録された値) の対応は下記のとおりです。
走行モード
表示
E-E, REC-PAUSE, REC
およびこれらからのSTOP
ソースデータ
(レコーダ内部の設定値)
FWD
およびこれからのSTOP
テープデータ
(テープ上に記録された値)
#ª CAUTION表示エリア
DC減電圧・結露・記録/再生エラーに関する警告が表示されます。
$º MONI表示エリア
モニタされているチャンネルナンバーが表示されます。
$¡ RANGE表示エリア
• モニタされているチャンネルの入力レンジ値 (ソースデータ/テープデータ) が
表示されます。
走行モードとソースデータ/テープデータの対応は下記のとおりです。
走行モード
表示
E-E, REC-PAUSE, REC
およびこれらからのSTOP
ソースデータ
FWD
およびこれからのSTOP
テープデータ
• OUTモードのときは設定対象チャンネルの出力レベル値 (ソースデータのみ)
が表示されます。なお、このときはRANGEの文字は消えます。
$™ SPEED表示エリア
そのテープが記録されたときのテープ速度 (テープデータ) がFWDモード中に表
示されます。
3-17
$£ テープ位置表示エリア
• テープ位置および時刻に関する下記の情報 (ソースデータ/テープデータ) が表
示されます。
ADDRESS : 各記録ブロックの先頭 (00H00M00S) からのテープの位置が時分
秒で表示されます。記録開始時には自動的に00H00M00Sにセッ
トされます。
参考
標準速のときは実時間と一致してカウントし、1/2速以下では速
度に比例して遅くなります。右端の矩形マークはファンコント
ロールモードの表示用となります。
1/2速以下では秒の桁の数値が毎秒1回の割で点滅します。
REMAIN
: テープ残量がテープ速度に応じて時分で表示されます。 S-TIME
: レコーダ本体側の現在時刻が年月日および時分秒で表示されます。
T-TIME
: テープ上に記録された時刻が年月日および時分秒で表示されます。
走行モードとソースデータ/テープデータの対応は下記のとおりです。
走行モード
表示
備考
E-E, REC-PAUSE, REC
およびこれらからのSTOP
ソースデータ
レコーダ内部のADDRESS,
REMAIN, S-TIME設定値
FWD
およびこれからのSTOP
テープデータ
テープ上に記録された
ADDRESS, REMAIN, T-TIME値
• OFFSETモードのときは設定対象チャンネルの入力DCオフセット量 (ソース
データのみ) が表示されます。
3-18
ディスプレイキーエリア
dB
%
OVR 1 1/2 1/4 1/8 1/16 1 2
SPD
AUX
EXT TC
EXP SYN
ID
CAUTION
OVR
+2
+100
0
MONI
–6
SPEED
V X1/
S- TIME
ADDRESS REMAIN T - T I M E
Y
M
D
H
M
S
0
-20
-40 -100
OVR
CH
RANGE
CH
1-4 5-8
S I R -1000W
9-12 13-16
PK-CLR
ALL CH SELECT
LOAD
CLOCK
$•
$¶
$§
$¢
$∞
$¢ PK-CLRキー
バーメータの表示モードがピークホールドのとき、このキーを押すごとにピー
クインジケータおよびOVR LEDがクリアされます。
$∞ ALL CHキー
RANGE, OFFSET, OUTの各モード中にこのキーを押すと、レコーダ本体または
チャンネル拡張ユニットのCH 1∼CH 16が選択された数値と同一に設定されま
す。
$§ SELECTキー
このキーを押すごとにアドレス (ADDRESS)・テープ残量 (REMAIN)・タイム
(S-TIME/T-TIME) の表示が下記のように切り換わります。
• E-E, REC-PAUSE, RECモード中 : ADDRESS → REMAIN → S-TIME (Y,M,D)
→ S-TIME (H,M,S)→ ADDRESS
• STOP, FWD, FF, REWモード中 : ADDRESS → REMAIN → T-TIME (Y,M,D)
→ T-TIME (H,M,S) → ADDRESS
3-19
$¶ LOADキー
このキーをSTOPまたはE-Eモード中に押すと、LCD画面上にLOAD OK?のメッ
セージが点滅します。もう一度このキーを押すと、下記の各設定条件が前回再
生したテープと同一条件に設定され、LOAD OK?のメッセージが消灯します。
チャンネルモード・テープ速度・入力レンジ・入力DCオフセット
LOADを中止するときはSTOPキーを押します。
参考
テープを再生後、有効になります。
$• CLOCKキー
レコーダ内部の時刻を設定するときに押します。
設定方法は5-6頁を参照してください。
3-20
アナログ入力部
POWER
BATT
SPD/BCM
dB
Advanced
Intelligent
Tape
%
OVR 1 1/2 1/4 1/8 1/16 1 2
SPD
AUX
–6
FF EOD
FWD
STOP
RANGE
M
MONI
REC
CH
SPEED
OFFSET
A
M
A
SEARCH
OUT/TSG
(UNIT)
ID/UTL
MRK/SLF
SHIFT
CH
OVR
PAUSE
RANGE
V X1/
S- TIME
ADDRESS REMAIN T - T I M E
Y
M
D
H
M
S
0
-40 -100
REW
(CH)
CAUTION
OVR
-20
BOD
ID
+2
+100
0
LOADING
EJECT
EXT TC
EXP SYN
1-4 5-8
PNL LOK
9-12 13-16
S I R -1000W
PK-CLR
DATA
ALL CH SELECT
LOAD
CLOCK
VOL
PHONE
MIC
ANN/P-SV
INSTRUMENTATION DIGITAL DATA RECORDER
ANALOG
INPUT
≤ ± 100vpk
1
2
3
100k
4
5
6
7
LSB DIGITAL
INPUT
8
≤ ± 10vpk 10k
D1
D2
D3
D4
ANALOG
MONITOR
REF
$ª
%º
%¡
$ª ANALOG INPUTコネクタ
CH 1∼CH 8のアナログデータ信号を入力するときに使います。
! 警告
• 必ず指定範囲の電圧 (±26.6 Vpk) を入力してください。
• 入力電圧が±100 Vpkを超えると内部回路が破損することがあります。
参考
チャンネルモードにより、有効なコネクタが異なります。
各チャンネルモードごとの表示に従ってください。
チャンネルモード
2
4
8
16 (拡張時)
有効チャンネル
1, 2
1∼4
1∼8
1∼16
%º チャンネルモードLED
設定されているチャンネルモードのLEDが点灯します。
%¡ ANALOG MONITORコネクタ
選択されたチャンネルのアナログデータ信号をモニタするときに使います。
3-21
LSBデジタル入力部
POWER
BATT
SPD/BCM
dB
Advanced
Intelligent
Tape
%
OVR 1 1/2 1/4 1/8 1/16 1 2
SPD
AUX
FWD
STOP
REC
OVR
PAUSE
CH
RANGE
SPEED
CH
V X1/
S- TIME
ADDRESS REMAIN T - T I M E
Y
M
D
H
M
S
0
-40 -100
FF EOD
RANGE
M
MONI
–6
REW
(CH)
CAUTION
OVR
-20
BOD
ID
+2
+100
0
LOADING
EJECT
EXT TC
EXP SYN
1-4 5-8
S I R -1000W
M
A
SEARCH
OUT/TSG
(UNIT)
ID/UTL
MRK/SLF
SHIFT
PNL LOK
9-12 13-16
PK-CLR
OFFSET
A
DATA
ALL CH SELECT
LOAD
CLOCK
VOL
PHONE
MIC
ANN/P-SV
INSTRUMENTATION DIGITAL DATA RECORDER
ANALOG
INPUT
≤ ± 100vpk
1
2
3
100k
4
5
6
7
LSB DIGITAL
INPUT
8
≤ ± 10vpk 10k
D1
D2
D3
D4
ANALOG
MONITOR
%£
REF
%™
%™ LSB DIGITAL INPUTコネクタ
CH D1∼CH D4のLSBデジタルデータ信号を入力するときに使います。
! 警告
• 必ずTTLレベルを入力してください。
• 入力電圧が±10 Vpkを超えると内部回路が破損することがあります。
参考
チャンネルモードにより、有効なコネクタが異なります。
各チャンネルモードごとの表示に従ってください。
チャンネルモード
1
2
4
有効チャンネル
1
1, 2
1∼4
%£ チャンネルモードLED
• 設定されているチャンネルモードのLEDが点灯します。
• 入出力信号に変化 (High/Lowの繰り返しが一定期間内に起こる) のある場合、
LEDが点滅します。
参考
入出力信号に変化のない場合、LEDは点灯します。
3-22
3-2 背面パネル
コントロール部
電源部
8 7 6 5 4 3 2 1
!
9
8
25
6
7
24
21
22
23
19
20
18
17
16
15
14
1
5
4
3
2
13
12
11
10
9
8
7
6
5
4
3
2
1
EXT. CONT
REMOTE
COM
AUX-2 (IRIG-B)
IN
OUT
SYNC
AUX-1 (DIGITAL)
IN
OUT
TRIG/REC
IN
% / dB
MST / SLV
IRIG ON / OFF
APD OFF / ON
(UP / DOWN)
VOLTAGE
AC FUSE
T4A
! SELECTOR
220V
RAL / HLD
9.6 / 19.2
TRG S/M
PTRG OFF/ON
240V
DC IN
STAND BY
AC IN
DC BREAKER
XLR 32F
S
HR
CANNON
OPTION SLOT 2
OPTION SLOT 1
オプション
スロット部
D4
D3
D2
D1
LSB DIGITAL
OUTPUT
LSBデジタル出力部
ANALOG
8
7
6
5
4
3
2
1 OUTPUT
アナログ出力部
3-23
電源部
7
4
8 7 6 5 4 3 2 1
% / dB
MST / SLV
IRIG ON / OFF
APD OFF / ON
(UP / DOWN)
!
AC FUSE
T4A
220V
RAL / HLD
9.6 / 19.2
TRG S/M
PTRG OFF/ON
3
240V
DC IN
XLR 32F
VOLTAGE
! SELECTOR
AC IN
STAND BY
DC BREAKER
1
CANNON
OPTION SLOT 1
2
6
5
1 STAND BYスイッチ
レコーダの主電源をON/OFFするときに使います。
参考
AC電源が接続されていれば、バッテリパック充電機能はSTAND BYスイッチに
かかわらず有効です。
2 AC IN
外部AC電源をレコーダに供給するときに使います。
付属のAC電源コードを接続してください。
! 注意
必ず指定範囲内の電圧を供給してください。
3 AC電圧切換スイッチ
AC電源電圧を100/120 V (許容範囲90∼132 V) と220/240 V (許容範囲198∼250 V)
とに切り換えるときに使います。
! 注意
• 必ず使用する電圧の側に切り換えてください。
• AC電源コードには安全アースが付いています。必ず接地されたコンセントに
接続してください。
4 ACヒューズ
AC電源系保護のためのヒューズです。
! 注意
必ず指定のヒューズを使用してください。
ヒューズを交換する際は必ずACケーブルを抜いてから交換してください。
3-24
5 DC IN
外部DC電源をレコーダに供給するときに使います。
付属のDC電源コードを接続してください。
! 注意
必ず指定範囲内の電圧(DC 11∼30V)を供給してください。
6 DCサーキットブレーカ
DC電源系保護のためのサーキットブレーカです。
作動するとレバーが手前に倒れますので、いったん電源コードを抜き、少し時
間をおいてからレバーを指先で上に起こして押込んで復帰させてください。
7 デジタルスイッチ
表記のスラッシュの左側がスイッチを上げた状態、右側が下げた状態を示しま
す。
(例) MST/SLV
スイッチ (下)
スイッチ (上)
なお、出荷時の設定はすべて上側になっています。
1) RAL/HLD
バーメータのピークインジケータの応答特性を切り換えるときに使います。
HLD (ピークホールド) モードではPK-CLRキーが押されるまで、または次に
E-E, REC-PAUSE, RECまたはFWDのいずれかのモードに入るまでピークイン
ジケータが最大レベルにホールドされます。
2) 9.6/19.2
COMコネクタにおけるRS-232Cの伝送レートを切り換えるときに使います。
9.6
: 9.6 kbps
19.2 : 19.2 kbps
3) TRG S/M
記録ポーズ状態のとき、Sのポジションにした場合はトリガ入力信号がHighか
らLowになると記録を開始し、STOPキーが押されるまで記録を続けます。
Mのポジションにした場合はトリガ入力信号がLowになると記録を開始し、
Highになると記録ポーズ状態になります。
4) PTRG OFF/ON
プリトリガ記録モードのON/OFFを切り換えるときに使います。
3-25
5) APD OFF/ON
APD (オートパワーダウン) モードをON/OFFするスイッチです。
APDモードとは、バックアップ電源がある場合で優先電源が停電したとき
に、自動的に停止処理をしたのちレコーダの電源をOFFするモードです。
下記の電源接続の場合に有効です。
OFFされる優先電源
バックアップ電源
AC
AC
AC
DC
DCおよびバッテリ (DC優先)
DC
バッテリ
バッテリ
• APDモードONの場合
―記録中:テープにTOCおよびEODを書き込んで記録を終了したのち電源
OFFとなります。
―記録中以外:STOPモードに入ったのち電源OFFとなります。
再度電源が供給されるとレコーダは自動的に以下の動作に入ります。
―記録中であったとき:IDをインクリメントしてRECモードに入ります。
―記録中以外であったとき:STOPモードに入ります。
参考
APDモードONのとき、レコーダの電源がOFFになっても微小電流が流れて
いますので、長時間この状態のままにしておくとバッテリーは放電してし
まいます。
• APDモードOFFの場合
優先電源が停電したときにバッテリがバックアップするモードで、その
バッテリが続くかぎりレコーダは動作を続けますが、正常終了しないこと
があります。
6) IRIG ON/OFF
AUXアナログチャンネルにIRIG-Bタイムコード信号を記録するときONにし
ます。それ以外のアナログ信号を入力するときにはOFFにしてください。
7) MST/SLV
同期運転の場合、レコーダをマスターまたはスレーブに設定するときに使いま
す。
8) %/dB
バーメータのスケールを%またはdBに切り換えるときに使います。
3-26
コントロール部
9
0
AC BREAKER
8 7 6 5 4 3 2 1
8
25
6
7
24
21
22
23
19
20
18
17
16
15
14
1
4
2
3
13
12
11
10
9
8
7
6
5
4
3
2
1
!™
REMOTE
5
EXT. CONT
!¢
9
8
COM
AUX-2 (IRIG-B)
IN
OUT
AUX-1 (DIGITAL)
IN
OUT
RAL / HLD
9.6 / 19.2
TRG S/M
PTRG OFF/ON
% / dB
MST / SLV
IRIG ON / OFF
APD OFF / ON
(UP / DOWN)
SYNC
TRIG/REC
IN
DC IN
DC BREAKER
XLR 32F
S
HR
CANNON
!£
!¡OPTIO
OPTION SLOT 2
!∞
16
15
14
13
12
11
10
9
8
7
6
5
4
8 EXT. CONTコネクタ
外部メイク接点によりレコーダをコントロールするときに使います。
9 COMコネクタ
ホストコンピュータよりRS-232C経由でレコーダをコントロールするときに使い
ます。
0 SYNCコネクタ
複数のレコーダを同期運転するときに使います。
!¡ TRIG/REC INコネクタ
トリガ記録の場合、トリガを入力するときに使います。
!™ REMOTEコネクタ
リモートコントロールユニット (別売) を接続するときに使います。
!£ AUX-1 (DIGITAL) IN/OUT
AUXデジタルチャンネルのデータの入力および出力に使います。
!¢ AUX-2 (IRIG-B) IN/OUT
AUXアナログチャンネルのデータの入力および出力に使います。
!∞ アース端子
接地端子です。信号ラインのアース側および筐体と同電位になっています。
3-27
オプションスロット部
8 7 6 5 4 3 2 1
!
9
8
25
6
7
24
21
22
23
19
20
18
17
16
15
14
1
4
2
3
13
12
10
11
9
8
7
6
5
4
3
2
1
REMOTE
5
EXT. CONT
COM
AUX-2 (IRIG-B)
IN
OUT
% / dB
MST / SLV
IRIG ON / OFF
APD OFF / ON
(UP / DOWN)
SYNC
AUX-1 (DIGITAL)
IN
OUT
TRIG/REC
IN
VOLTAGE
AC FUSE
T4A
! SELECTOR
220V
RAL / HLD
9.6 / 19.2
TRG S/M
PTRG OFF/ON
240V
DC IN
STAND BY
AC IN
DC BREAKER
XLR 32F
S
HR
CANNON
OPTION SLOT 2
D4
D3
D2
OPTION SLOT 1
D1
LSB DIGITAL
OUTPUT
ANALOG
8
7
6
5
4
3
2
1 OUTPUT
!§
!§ オプションスロット
オプションボードをここに挿入します。挿入できるボードの種類は下記のとお
りです。
OPTION SLOT 1 : SDX SCSIエミュレーションボード, 高速SCSI転送ボード
OPTION SLOT 2 : チャンネル拡張用ボード, ビットストリームボード、
MPEGビデオボード
アナログ出力部
VOLTAGE
AC FUSE
T4A
8 7 6 5 4 3 2 1
! SELECTOR
!
SYNC
TRIG/REC
IN
% / dB
MST / SLV
IRIG ON / OFF
APD OFF / ON
(UP / DOWN)
220V
RAL / HLD
9.6 / 19.2
TRG S/M
PTRG OFF/ON
240V
DC IN
STAND BY
AC IN
DC BREAKER
XLR 32F
CANNON
OPTION SLOT 1
DIGITAL
TPUT
8
7
6
5
4
3
2
1
ANALOG
OUTPUT
!•
!¶
!¶ ANALOG OUTPUTコネクタ
CH 1∼CH 8のアナログデータ信号を出力するときに使います。
BNCケーブル (別売) をそれぞれに接続してください。
!• 出力レベル調整ボリウム
CH 1∼CH 8のアナログデータ信号の出力レベルを調整するときに使います。
OUTモードでの選択がマニュアルポジションのときに有効です。
参考
チャンネルモードにより、有効なコネクタ・ボリウムが異なります。
各チャンネルモードごとの表示に従ってください。
3-28
チャンネルモード
2
4
8
16 (拡張時)
有効チャンネル
1, 2
1∼4
1∼8
1∼16
LSBデジタル出力部
9
8
25
6
7
24
21
22
23
19
20
18
17
16
15
14
1
5
4
3
2
13
12
10
11
9
8
7
6
5
4
3
2
1
EXT. CONT
REMOTE
COM
AUX-2 (IRIG-B)
IN
OUT
SYNC
AUX-1 (DIGITAL)
IN
OUT
TRIG/REC
IN
MS
IRIG ON
APD OF
(UP / D
S
HR
OPTION SLOT 2
D4
D3
D2
D1
LSB DIGITAL
OUTPUT
8
!ª
!ª LSB DIGITAL OUTPUTコネクタ
CH D1∼CH D4のLSBデジタル信号を出力するときに使います。
BNCケーブル (別売) をそれぞれに接続してください。
参考
チャンネルモードにより、有効なコネクタが異なります。
各チャンネルモードごとの表示に従ってください。
チャンネルモード
1
2
4
有効チャンネル
1
1, 2
1∼4
3-29
3-3 左側面パネル
2
1
3
BKW-L601
DO NOT PUT RECORDER ON THIS SIDE.
OTHERWISE BATTERY ADAPTER MAY BREAK.
この面を下向きに置かないでください。
バッテリー装着アダプターの破損を防止するためです。
2-902-854-01
1 バッテリパック装着部
バッテリパックBP-L60/L60A (別売) またはBP-L90/L90A (同) をここに取り付け
ます。バッテリパックの溝をバッテリパック装着部のガイドに合わせて、奥に
スライドさせます。
2 取外しボタン
バッテリパックを取り外すときに押します。
! 注意
バッテリパックは重く、また熱くなることがありますので、落とさないように
してください。
3 フィルタ (通風孔)
レコーダ内部を冷却するための空気の取り入れ口です。
フィルタはレコーダ内部への塵埃の侵入を防ぎます。
! 警告
• レコーダ内部の過熱を防ぐため、フィルタ部をふさがないようにしてください。
• レコーダ左側面に熱のある物体を置かないでください。
• レコーダ左側面と他の物体の間隔は50 mm以上離してください。
! 注意
• フィルタにはほこりが溜まりやすいので、ときどき清掃または交換を行なって
ください。 (汚れ具合にもよりますが、1ヶ月毎を目安に交換してください。)
• 清掃後は必ず取り付けてください。
• フィルタのご注文は「SIR用ダストフィルタ」として、サービスまでご用命く
ださい。
フィルタの清掃および交換
フィルタカバーはマジックテープで本体に固定されています。
フィルタカバーの窓の上端を手前に引き、フィルタカバーおよびフィルタを外
3-30
して、清掃または交換作業を行なってください。
3-4 右側面パネル
1
2
SIR-1000W Ser.
Sony Precision Technology Inc.
MADE IN JAPAN
2-902-848-01
1 冷却ファン
レコーダ内部を冷却するファンです。
! 警告
• レコーダ内部の過熱を防ぐため、風の吹き出し口をふさがないようにしてくだ
さい。
• レコーダ右側面と他の物体の間隔は50 mm以上離してください。
! 注意
バッテリパックを充電中は、STAND BYスイッチにかかわらず冷却ファンが回
転します。
2 スピーカ
ボイスチャンネルまたはモニタチャンネルの音声を再生するスピーカです。
3-31
4 準備
4-1 電源の接続
AC電源で使用する場合
1
使用する電圧に合わせ、AC電圧切換スイッチを100/120 Vまたは220/240 Vのい
ずれかに設定してください。
2
AC電源コード (付属品) をAC INコネクタに接続し、AC電圧切換スイッチで設
定されたAC 90∼132 V (100/120 Vに設定時) またはAC198∼250 V ( 220/240 Vに
設定時) のいずれかをレコーダに供給してください。
9
8
25
6
7
24
21
22
23
19
20
18
17
16
15
14
1
4
3
2
13
12
11
10
9
8
7
AUX-2 (IRIG-B)
IN
OUT
SYNC
AUX-1 (DIGITAL)
IN
OUT
TRIG/REC
IN
% / dB
MST / SLV
IRIG ON / OFF
APD OFF / ON
(UP / DOWN)
! SELECTOR
!
5
6
5
4
3
2
1
REMOTE
COM
VOLTAGE
AC FUSE
T4A
8 7 6 5 4 3 2 1
EXT. CONT
220V
RAL / HLD
9.6 / 19.2
TRG S/M
PTRG OFF/ON
240V
DC IN
STAND BY
AC IN
DC BREAKER
XLR 32F
S
HR
CANNON
OPTION SLOT 2
D4
D3
D2
OPTION SLOT 1
D1
LSB DIGITAL
OUTPUT
8
7
6
5
4
3
2
1
ANALOG
OUTPUT
! 警告
• AC電圧切換スイッチがAC100/120 Vに設定されたレコーダにAC198∼250 Vを供給
すると、内部の回路が破損することがあります。
• AC電圧切換スイッチがAC220/240 Vに設定されたレコーダにAC 90∼132 Vを供給
すると、動作しません。
• AC電源コードには安全アースが付いています。必ず接地されたコンセントに接続
してください。
• プラグ変換アダプタ (3P-2P) をご使用の場合は、緑色のコードを必ず接地してくだ
さい。
! 注意
• インバータなどからAC電源を取るときは、スパイクノイズが混入しないようにし
てください。
• バッテリパックを充電するときは、STAND BYスイッチにかかわらず充電機能が
働き、右側面の冷却ファンが回転します。充電が完了すれば冷却ファンの回転も自
動的に停止します。
4-1
DC電源で使用する場合
DC電源コード (付属品) をDC INコネクタに接続し、DC 12 V (許容範囲11∼30 V) を
供給してください。
9
8
25
6
7
24
21
22
23
19
20
18
17
16
15
14
1
4
3
2
13
12
11
10
9
8
7
AUX-2 (IRIG-B)
IN
OUT
SYNC
AUX-1 (DIGITAL)
IN
OUT
TRIG/REC
IN
% / dB
MST / SLV
IRIG ON / OFF
APD OFF / ON
(UP / DOWN)
! SELECTOR
!
5
6
5
4
3
2
1
REMOTE
COM
VOLTAGE
AC FUSE
T4A
8 7 6 5 4 3 2 1
EXT. CONT
220V
RAL / HLD
9.6 / 19.2
TRG S/M
PTRG OFF/ON
240V
DC IN
STAND BY
AC IN
DC BREAKER
XLR 32F
S
HR
CANNON
OPTION SLOT 2
D4
D3
D2
OPTION SLOT 1
D1
LSB DIGITAL
OUTPUT
ANALOG
8
7
6
5
4
3
2
1 OUTPUT
! 警告
過電圧が印加されると、内部の回路が破損することがあります。
!
注意
• DC電源コード (付属品) の極性は赤:+、黒:−です。
• コネクタのピンアサインはPin 1:+、Pin 2:−、Pin 3:フレームGNDです。
1
2
3
• レコーダに規定のAC電源が供給されているときは、そちらが優先します。
• 使用するDC電源装置の出力電圧は30 V、電力は150 Wをいずれも超えないように
してください。
• バッテリバックアップをしているときに、DC電源が11 V未満になる可能性がある
場合はバッテリを外さないでください。
4-2
バッテリパックを使用する場合
バッテリパックBP-L60/L60A (別売) またはBP-L90/L90A (同) を左側面のバッテリパッ
ク装着部に装着してください。
BKW-L601
こ
の
バッ
面
を
テリ
下
ー装
向
着ア
き
ダプ
に
ター
置
の破
か
損を
な
い
防止
で
する
く
ため
だ
です
。
さ
い
。
LO
C
K
E
C
H
E
C
K
F
バッテリの連続使用時間の目安は、フルチャージされた新品の場合下記のとおりです。
バッテリ
ノーマルモード
パワーセーブモード
2∼8 chモード
16 chモード
2∼8 chモード
16 chモード
BP-L60/L60A
約40分
使用不可
約60分
使用不可
BP-L90/L90A
約70分
約20分
約120分
約60分
!
注意
• 上記のバッテリパック以外は使用しないでください。
• 拡張ユニットやオプションボードを使用する場合は、BP-L90/L90Aをご使用くださ
い。
• バッテリパックは、フルチャージされたものを使用してください。バッテリパッ
クのCHECKボタンを押してFのLEDが点灯すればフルチャージされています。
• レコーダに規定のACまたはDC電源が供給されているときは、そちらが優先します。
• 長時間使用しないときは、本体から外してください。
• 16 chモードでDC駆動中にバッテリパックでバックアップをする場合は本体・拡張そ
れぞれにDC電源 (11 V以上) を供給してください。
• オプションボードとの併用では、上記連続使用時間の目安は短くなります。
4-3
4-2 カートリッジ
カートリッジ
最良の状態で記録/再生/データ保存を行なうため、下記の事項を守ってください。
! 注意
• レコーダをPOWER OFFするときは、必ずカートリッジを取り出した後にSTAND
BYスイッチをOFFしてください。カートリッジを入れたままPOWER OFF状態で長
期間放置すると、温度・湿度の変化によってテープが伸び縮みしたり、結露によっ
てテープ走行系に貼り付いたりすることがあります。
• カートリッジ内のテープには指が触れにくい構造になっていますが、もしリッド
を開けるときはテープに触れないようにしてください。
• カートリッジの接点端子は常に清浄に保ち、指で直接触れないよう注意してくだ
さい。
• 下記のカートリッジのみ使用できます。
型名
メーカ
SDX1-25C (MIC付き)
SDX-T3C (MIC付き)
SDX-T3N (MIC無し)
SONY
MICに書き込まれたTOCデータを利用してデータへのアクセスを早く行なうた
め、MIC付きのカートリッジの使用をおすすめします。
4-4
カートリッジの入れ方
1
STAND BYスイッチをONします。POWER LEDが点灯していることを確認して
ください。
2
カートリッジ蓋を指で手前に引いて開けます。
POWER LED
POWER
BATT
OVR 1 1/
dB
%
OVR
+2
+100
0
–6
2
0
-20
LOADING
-40 -100
EJECT
BOD
REW
FF EOD
FWD
STOP
REC
OVR
PAUSE
CH
1-4
S I R -10
INS
ANALOG
INPUT
3
1
± 100vpk
3
2
100k
4
5
6
7
8
カートリッジを入れます。下図の矢印のところ (背面中央) を押してください。
途中まで押し込むと自動的にローディングされます。ローディング中はLOADING LEDが点滅し、ローディングが完了すると点灯します。
参考
MIC無しのカートリッジではローディング/アンローディングに時間が長くかか
ることがあります。
POWER
BATT
OVR 1 1
dB
%
OVR
+2
+100
0
–6
0
-20
LOADING
-40 -100
EJECT
BOD
REW
FF EOD
FWD
STOP
REC
OVR
PAUSE
CH
LOADING LED
3
4
1-4
S I R -1
INS
ANALOG
INPUT
1
2
± 100vpk
3
100k
4
5
6
7
8
カートリッジ蓋を指で向こう側に押して閉めます。
!
注意
• カートリッジ挿入口のフィルムは、テープの走行部への埃の侵入を防ぐためのも
のです。剥がさないでください。
• カートリッジを強く押しすぎると故障の原因になります。
• レコーダが電源OFFの状態ではカートリッジを受け付けません。
• LCD画面上にエラーコードが表示されているときもカートリッジを受け付けませ
ん。STAND BYスイッチをいったんOFFし、ONし直してから再度操作してくださ
い。
4-5
カートリッジの取り出し方
2, 4
POWER
BATT
Advanced
Intelligent
Tape
カートリッジ蓋
LOADING
LOADING LED
EJECT
BOD
REW
FF EOD
FWD
STOP
REC
PAUSE
1
1
EJECTボタンを押します。カートリッジがアンローディングされます。
アンローディング中はLOADING LEDが点滅し、アンローディングが完了すると
消灯します。
参考
MIC無しカートリッジの場合はBODに巻戻されたのちエジェクトされます。
2
カートリッジ蓋を指で手前に引いて開けます。
3
カートリッジの左右を指でつまんで手前に引いて取り出します。
3
POWER
BATT
OVR 1 1
dB
%
OVR
+2
+100
0
2
–6
0
-20
LOADING
-40 -100
EJECT
BOD
REW
FF EOD
FWD
STOP
REC
OVR
PAUSE
CH
1-4
S I R -1
INS
ANALOG
INPUT
4
!
1
2
± 100vpk
3
100k
4
5
6
7
8
カートリッジ蓋を指で押して閉めます。
注意
正面パネルを上向きにするとカートリッジを取り出せない場合があります。
4-6
記録済みデータの保護
大事なデータに誤って重ね書きしてしまわないよう、下図のようにカートリッジの
爪の位置を切り換えて、記録防止孔が開いた状態にしてください。
なお、この状態で記録しようとするとカートリッジがエジェクトされます。
記録可能の状態
…
(記録防止孔:閉)
記録不可の状態
…
(記録防止孔:開)
REC
SAVE
クリーニングテープ
(記録エラー) が頻繁に表示されるときは、付属のクリーニングテープを使用し、
ヘッドのクリーニングを行なってください。
クリーニングテープをローディングすると、ヘッドをクリーニングしたのち自動的
にエジェクトされます。
4-7
4-3 セルフチェック
実際に記録/再生などを行なう前に、レコーダに異常のないことを確認するため、セ
ルフチェック(自己診断) を行なうことをおすすめします。
本機のセルフチェックは下記の内容です。
SLF (セルフチェック) モード
内容
CAL (キャリブレーション) モード
テープ走行系 (メカ) チェック
記録/再生ヘッドチェック
記録/再生アンプチェック
所要時間
DCオフセットエラー補正
ゲインエラー補正
約1分
約8分 (周波数帯域ごとに実行)
SLF (セルフチェック) モード
SLFモードでは実際にテープに信号を記録/再生します。
バーメータエリア
SPD/BCM
dB
%
OVR 1 1/2 1/4 1/8 1/16 1 2
SPD
AUX
EXT TC
EXP SYN
ID
RANGE
M
OVR
+2
+100
0
–6
MONI
RANGE
SPEED
V X1/
S- TIME
ADDRESS REMAIN T - T I M E
Y
M
D
H
M
S
0
OFFSET
A
M
A
SEARCH
OUT/TSG
(UNIT)
ID/UTL
MRK/SLF
SHIFT
CH
-20
-40 -100
OVR
CH
(CH)
CAUTION
1-4 5-8
S I R -1000W
PNL LOK
9-12 13-16
PK-CLR
DATA
ALL CH SELECT
LOAD
CLOCK
VOL
PHONE
MIC
ANN/P-SV
2
INSTRUMENTATION DIGITAL DATA RECORDER
1
レコーダの電源を入れ、カートリッジを挿入します。
2
SHIFTキーを押してからMRK/SLFキーを押すとSLFモードとなります。
バーメータエリアにSLFと表示されます。
SLFモード中はバーメータエリアのOVRマークによって経過表示が行なわれま
す。
3
セルフチェックが完了し、異常がなければバーメータエリアのSLFの表示は消
え、IDナンバーが1つ増加します。
異常があるときはバーメータエリアにSLF NGと表示されますので、別項の説明
に従って処置を行なってください。
4
SLFモードを途中で終了するときは、STOPキーを押します。
参考
カートリッジが記録防止状態になっていると、自動的にエジェクトされます。
記録防止爪を動かして記録可能状態にしてから、もう一度操作してください。
4-8
CAL (キャリブレーション) モード
本機は工場出荷時にキャリブレーションを行ない、その設定はメモリに保存されて
いますので、頻繁にキャリブレーションを行なう必要はありませんが、年に数回は
実行することをおすすめします。
バーメータエリア
SPD/BCM
dB
%
OVR 1 1/2 1/4 1/8 1/16 1 2
SPD
AUX
EXT TC
EXP SYN
ID
RANGE
M
OVR
+2
+100
0
–6
MONI
SPEED
V X1/
S- TIME
ADDRESS REMAIN T - T I M E
Y
M
D
H
M
S
0
RANGE
OFFSET
A
M
A
SEARCH
OUT/TSG
(UNIT)
ID/UTL
MRK/SLF
SHIFT
CH
-20
-40 -100
OVR
CH
(CH)
CAUTION
1-4 5-8
S I R -1000W
PNL LOK
9-12 13-16
PK-CLR
DATA
ALL CH SELECT
LOAD
CLOCK
VOL
PHONE
2
MIC
ANN/P-SV
INSTRUMENTATION DIGITAL DATA RECORDER
1
レコーダの電源を入れます。
2
SHIFTキーを押してからMRK/SLFキーを1秒以内に2回押すとCALモードとなり
ます。バーメータエリアにCALと表示されます。
CALモード中はバーメータエリアのOVRマークによって経過表示が行なわれま
す。
3
キャリブレーションが完了し、異常がなければバーメータエリアのCALの表示
は消えます。
もし異常があるときは、バーメータエリアにエラーコードが表示されますの
で、別項の説明に従って処置を行なってください。
4
CALモードを途中で終了するときは、STOPキーを押します。
この場合、各周波数帯域の変わり目で終了となります。
! 注意
• 電源投入後、15分経過 (ウォームアップ) ののちCALモードを実行してください。
• 実際に使用される環境でCALを行なってください。
• CALモードを途中で終了した場合は、電源を再投入してください。
4-9
4-4 エラーコード
セルフチェック中・キャリブレーション中または記録/再生中にレコーダ内部に異常
があるときは、バーメータエリアに下記のエラーコードが表示されますので、それ
ぞれの内容に応じて処置を行なってください。
なお、塵埃が多い環境下などで使用したとき、データ再生 (記録時のベリファイを含
む) ができない場合にもエラーコード (ET03) が表示されます。そのときは室内など
の環境で再生してください。
処置しても直らない場合や、記載以外のエラーコードが表示された場合は、サービ
スにご相談ください。
参考
スタンバイスイッチをONしても電源が入らない、またはキー操作がきかなくなった
場合は、スタンバイスイッチをOFFして電源ケーブルを抜き、再度接続してくださ
い。再度ONしても直らない場合は、サービスにご相談ください。
エラーコード
発生部位
内容
対処法
電源異常
サービスに相談してください
バッテリ充電異常
バッテリを交換してください
電源部過熱
指定範囲内の温度環境で使用してください
EP31
SCX-32低電圧
許容範囲内のDC電圧を供給してください
Ed20
RS-232C通信異常
正しいコマンドを入力してください
Ed30
リモコン通信エラー
リモコンの接続を確認してください
同期モード通信エラー
いったんSTOPし、再度同期モードに入れてください
アナログ通信エラー
拡張ケーブルが正しく接続されているか確認してください
EP03
EP11
EP30
電源系
Ed40
シスコン系/
Ed50
デジタル信号
処理系
拡張ユニットに供給している電源を確認してください
それでも直らない場合はサービスに相談してください
DSP通信エラー
サービスに相談してください
電源通信エラー
供給している電源ケーブルをいったん抜き、再度接続してください
EA20
記録系 CALエラー
サービスに相談してください
EA30
再生系 CALエラー
サービスに相談してください
EA40
再生不能エラー
チャンネルモードとテープ速度の設定を確認してください
Ed60
Ed70
電源系
デジタルモードのテープ再生時はSBS-10A/Sボードの有無を確
認してください
アナログ系
ADAボードバージョンエラー
サービスに相談してください
EA60
ADAフラッシュメモリエラー
サービスに相談してください
EA70
SCX IDエラー
SCXのID番号が重複しないようにしてください
EA80
ADAボードエラー
拡張ケーブルが正しく接続されているか確認してください
EA50
拡張ユニットに供給している電源を確認してください
それでも直らない場合はサービスに相談してください
4-10
エラーコード
内容
発生部位
ET03
対処法
メディアまたは塵埃に
テープを交換するか、ヘッドをクリーニングしてください
よる異常
室内などの環境で再生してください
それでも直らない場合はサービスに相談してください
ET04
ET08
テープ走行系
ET**
ハードウェア異常
電源をいったんOFFし、再度ONしてください
EOD誤検出
EJECTまたはBDDに巻戻してください
ハードウェア異常
15分以上ウォームアップを行ない電源をいったんOFFして再度
ONしてください
それでも直らない場合はサービスに相談してください
メディアまたは
テープを交換するか、ヘッドをクリーニングしてください
ハードウェア異常
それでも直らない場合はサービスに相談してください
EX10
STB-10ボード異常
サービスに相談してください
EX20
STB-30ボード異常
サービスに相談してください
EX21
STB-30通信異常
正しいコマンドを入力してください
SLF NG
それでも直らない場合はサービスに相談してください
EX30
周辺機器
同期設定エラー
マスター/スレーブの設定またはシンクケーブルの接続を確認
してください
EX31
ターゲットエラー
メディア異常または同期再生の対象となるデータが存在しません
EX32
同期記録/再生エラー
再度記録または再生してください
マスター機の電源を確認してください
EX33
同期記録エラー
マスター機をSTOPモードにしてから同期記録を開始してください
4-11
4-5 警告表示
レコーダ各部に異常が発生すると、下記の警告マークがCAUTIONエリアに点滅する
とともに警告音を発しますので、それぞれの説明に従って処置を行なってください。
処置しても直らない場合や、記載以外のエラーコードが表示された場合は、当社の
サービスにご相談ください。
CAUTIONエリア
dB
%
OVR 1 1/2 1/4 1/8 1/16 1 2
SPD
AUX
EXT TC
EXP SYN
ID
CAUTION
OVR
+2
+100
0
–6
MONI
SPEED
V X1/
S- TIME
ADDRESS REMAIN T - T I M E
Y
M
D
H
M
S
0
-20
-40 -100
OVR
CH
RANGE
CH
1-4 5-8
9-12 13-16
S I R -1000W
PK-CLR
ALL CH SELECT
LOAD
CLOCK
(DC減電圧)
バッテリまたは外部DC電源の電圧が規定値の下限より降下した場合に点滅します。バッ
テリをフルチャージされたものと交換するか、所定の外部DC電圧を供給してください。
電源供給
本体
動作可能ユニット
本体のみ
本体+拡張
本体+拡張ユニット
本体+拡張
規定下限電圧
11 V
15 V
各11 V
所定外部DC電圧
11∼30 V
15∼30 V
11∼30 V
! 注意
このマークが表示された状態で使用を続けると異常動作になることがありますの
で、早めに上記の処置を行なってください。
& (結露)
DEW機能がONのとき、冷えたレコーダを温かい場所に移動して、テープ走行系に結
露を生じたときに点灯します。
その際はレコーダにテープを挿入せずにSTAND BYスイッチをONのままウォームアッ
プを行ない、このマークが消灯したのちに使用してください。
DEW機能がONのときの表示内容
CAUTION表示
―
&マーク点灯
LCD表示
レコーダの状態
備考
LO T WAIT
HI T WAIT
180S∼000S
内部温度が5℃未満
内部温度が50℃以上
結露検出中
内部温度が5℃以上になるまで表示
内部温度が50℃未満になるまで表示
結露検出までの残り時間を表示
WARM WAIT
600S∼000S
結露を検出
結露解除中
ウォームアップ中表示
結露解除までの残り時間を表示
! 注意
• 温度、湿度の変化する環境では、必ずDEW機能をONにして使用してください。
• 保存中の結露によるヘッドドラムへのテープの貼り付きを防ぐため、レコーダを使
用後は必ずテープをエジェクトしてからSTAND BYスイッチをOFFしてください。
• レコーダの両側面と他の物体の間隔は50 mm以上離してください。
4-12
(記録/再生エラー)
記録エラー
記録エラーはテープへのデータ供給が追いつかなくなり、FIFOメモリが一杯になっ
た (FIFOオーバーフロー) とき表示されます。
マークが頻繁に表示されるようなときは、テープの傷やしわ、または塵埃などの
原因が考えられますので、新しいテープに交換してください。
それでも直らないようなときは、付属のクリーニングテープを使用してヘッドク
リーニングを行なってください。
それでもまったく直らないときは、サービスにご相談ください。
再生エラー
再生データにエラーがあり、かつ訂正できないときは、テープを巻き戻して当該部
分を再読み出し (リトライ) します。リトライの実行中は、正しいデータが読み出さ
れるまで、FIFOメモリに残っているデータが出力されます。FIFOメモリが空になる
前にリトライにより正しいデータが読み出されると、そのまま正常な再生が続き、
マークは現われません。リトライが繰返されるとFIFOメモリが空になり (FIFOア
ンダーフロー)、
マークが表示され出力データが一時途切れます。
以上のように、SIR-1000Wでは記録時のデータの確認を毎回行なっているため、再生
時エラーが起きても、テープを巻き戻してその部分を再度再生することによって、
エラーのないデータを読むことが可能です。また、別売のPC scan IIIを使ってコン
ピュータにデータを転送する場合は、FIFOアンダーフローによるリトライの制限が
ないため、よりエラーの少ない再生が可能です。
参考
圧縮モードで記録したテープをバージョン30未満のレコーダで再生すると、再生開
始直後に
マークが出ることがあります。
4-13
4-6 ソースモードとテープモード
ソースモード
レコーダがE-E, REC-PAUSE, RECの各モード中、およびこれらのモードからSTOPし
たときは、テープ位置情報 (IDナンバー・アドレス・リアルタイムクロック) および
アンプ設定情報 (入力レンジ値・入力DCオフセット値・出力レベル値) はソースデー
タ (レコーダ内部の設定値) を表示するソースモードに自動的に切り換わります。
ソースモード中にSELECTキーによって切り換わる内容および順序は下記のとおり
です。
SOURCE
アドレス
(±時分秒)
テープ残量
(時分)
ソースタイム
(年月日)
REMAIN
Y
H
S-TIME
SOURCE
ADDRESS
M
M
ソースタイム
(時分秒)
S-TIME
SOURCE
D
S
Y
H
M
M
D
S
SOURCE
Y
H
M
M
D
S
Y
H
M
M
D
S
テープモード
レコーダがFWDモード中、およびFWDモードからSTOPしたときは、テープ位置情
報(IDナンバー・アドレス・リアルタイムクロック) およびアンプ設定情報 (入力レン
ジ値・入力DCオフセット値・出力レベル値) はテープデータ (テープ上に記録されて
いる値) を表示するテープモードに自動的に切り換わります。
テープモード中にSELECTキーによって切り換わる内容および順序は下記のとおりで
す。
ADDRESS
Y
H
TAPE
M
M
D
S
Y
H
アドレス
(±時分秒)
REMAIN
M
M
テープ残量
(時分)
T-TIME
TAPE
D
S
Y
H
M
M
テープタイム
(年月日)
T-TIME
TAPE
D
S
Y
H
M
M
D
S
テープタイム
(時分秒)
TAPE
参考
STOPモード中にこれらのテープ位置情報またはアンプ設定情報に関する設定を変え
ると、自動的にソースモードに切り換わります。
4-14
4-7 ファンコントロールモード
• SHIFTキーを押してからANN/P-SVキーを3秒以上押すと、ファンコントロールモー
ドになります。SIR-1000WおよびSCX-16Wの機内温度が低いとき、RECモード中に
冷却ファンの回転を停止させることができますので、静粛性が要求される音響計測
などに便利です。ファンコントロールモード中はANN/P-SVキー右上のLEDが点滅
するとともに、LCD画面のテープ位置表示エリア右端に矩形マークが表示されま
す。
1) ファンコントロールモード中で機内温度が低いときはLCD画面の矩形マークが
点灯し、機内温度が上昇して注意温度を超えると矩形マークが点滅に変わって
注意を促します。
さらに機内温度が上昇して限界温度を超えると冷却ファンが自動的に回転を始
め、矩形マークが消灯し、ファンコントロールモードがOFFされます。
チャンネル構成
8 ch/16 ch
周囲温度
20℃
30℃
40℃
25 min
17 min
10 min
2) POWER ONからのファンの停止時間は、下記が目安です。
3) 連続使用中で機内温度が平衡状態にあるときのファンの停止時間は、下記が目
安です。
チャンネル構成
8 ch/16 ch
周囲温度
20℃
30℃
40℃
15 min
7 min
―
4) ファンコントロールモード中はP-SVモードと同様、アナログ再生系およびLCD
画面のバックライトがOFFされます。
5) ファンコントロールモードから抜けるときは、SHIFTキーを押してからANN/PSVキーを3秒以上押します。
本体内部温度
ファン回転温度 t 2
注意温度 t 1
周囲温度 t 0
ファンコントロールモード
OFFのままのとき
時間
POWER ON
ファンコントロール
ファンコントロール
ファンコントロール モードOFF (自動)
モード再OFF (自動)
モードON (手動)
ファンコントロール
POWER OFF
モード再ON (手動)
マーク
冷却ファン
点灯
点滅
停止
消灯
回転
点灯
点滅
停止
消灯
回転
4-15
5 データ記録/再生
5-1 信号系の接続
アナログデータ信号系の接続
BNCケーブル (別売) を用いて正面パネルのANALOG INPUTコネクタとアナログ信
号源とをチャンネルごとに接続してください。
必要に応じ、BNCケーブルを用いてANALOG MONITORコネクタにオシロスコープ
などの測定器を接続してください。
POWER
BATT
SPD/BCM
dB
Advanced
Intelligent
Tape
%
OVR 1 1/2 1/4 1/8 1/16 1 2
SPD
AUX
ID
-40 -100
REW
FF EOD
FWD
STOP
REC
OVR
PAUSE
CH
RANGE
RANGE
SPEED
CH
V X1/
S- TIME
ADDRESS REMAIN T - T I M E
Y
M
D
H
M
S
0
-20
LOADING
BOD
(CH)
CAUTION
OFFSET
M
MONI
–6
EJECT
EXT TC
EXP SYN
OVR
+2
+100
0
1-4 5-8
S I R -1000W
M
A
OUT/TSG
ID/UTL
MRK/SLF
(UNIT)
SHIFT
PNL LOK
9-12 13-16
PK-CLR
A
SEARCH
DATA
ALL CH SELECT
LOAD
CLOCK
VOL
MIC
PHONE
ANN/P-SV
INSTRUMENTATION DIGITAL DATA RECORDER
ANALOG
INPUT
≤ ± 100vpk
1
2
100k
3
4
5
6
7
≤ ± 10vpk 10k
LSB DIGITAL
INPUT
8
D1
D2
D3
ANALOG
MONITOR
D4
REF
オシロスコープ等
信号源
!
警告
入力電圧が±100 Vpkを超えると内部回路が破損することがあります。
!
注意
• ANALOG INPUTコネクタへの入力電圧は±26.6 Vpk以内にしてください。
• グランドレベルの異なる信号を同時に入力しないでください。
• 入力インピーダンスは100 kΩです。
LSBデジタルデータ信号系の接続
BNCケーブル (別売) を用いて正面パネルのLSB DIGITAL INPUTコネクタとデジタ
ル信号源とをチャンネルごとに接続してください。
POWER
BATT
SPD/BCM
dB
Advanced
Intelligent
Tape
%
OVR 1 1/2 1/4 1/8 1/16 1 2
SPD
AUX
–6
MONI
REW
FF EOD
FWD
STOP
(CH)
CAUTION
REC
OVR
PAUSE
CH
RANGE
RANGE
SPEED
CH
V X1/
S- TIME
ADDRESS REMAIN T - T I M E
Y
M
D
H
M
S
0
-40 -100
BOD
ID
M
-20
LOADING
EJECT
EXT TC
EXP SYN
OVR
+2
+100
0
1-4 5-8
S I R -1000W
M
A
OUT/TSG
ID/UTL
MRK/SLF
(UNIT)
SHIFT
PNL LOK
9-12 13-16
PK-CLR
OFFSET
A
SEARCH
DATA
ALL CH SELECT
LOAD
CLOCK
VOL
PHONE
MIC
ANN/P-SV
INSTRUMENTATION DIGITAL DATA RECORDER
ANALOG
INPUT
≤ ± 100vpk
1
2
3
100k
4
5
6
7
8
LSB DIGITAL
INPUT
≤ ± 10vpk 10k
D1
D2
D3
D4
ANALOG
MONITOR
REF
信号源
5-1
5-2 記録前の設定
データの記録を始める前に、必要な下記の設定をしてください。
• チャンネルモード (BCM)
• テープ速度 (SPD)
• 入力レンジ (RANGE)
• 入力DCオフセット (OFFSET)
• 内部時刻 (CLOCK)
レコーダをPOWER ONするとディスプレイには下記のような表示が現れます。
SPD
dB
%
ID表示エリア
OVR 1 1/2 1/4 1/8 1/16 1 2
SPD
AUX
EXT TC
EXP SYN
ID
CAUTION
OVR
+2
+100
0
MONI
–6
MONI
SPEED
V X1/
S- TIME
ADDRESS REMAIN T - T I M E
Y
M
D
H
M
S
0
-20
-40 -100
OVR
CH
1-4 5-8
S I R -1000W
5-2
RANGE
CH
9-12 13-16
PK-CLR
ALL CH SELECT
LOAD
CLOCK
RANGE
インデックス
(ID以外)
アナログチャンネルモード (BCM) の設定
SHIFTキーを押してからSPD/BCMキーを押し、;キーまたは:キーを押してチャン
ネルモードを設定します。
チャンネルモードに対応する周波数帯域は下記のとおりです。
フルアナログモード
チャンネルモード
4 chモード
8 chモード
16 chモード
チャンネル拡張ユニット
―
―
1台
1 (標準速)
DC∼160 kHz
DC∼80 kHz
DC∼40 kHz
1/2
DC∼80 kHz
DC∼40 kHz
DC∼20 kHz
1/4
DC∼40 kHz
DC∼20 kHz
DC∼10 kHz
1/8
DC∼20 kHz
DC∼10 kHz
DC∼5 kHz
1/16
DC∼10 kHz
DC∼5 kHz
DC∼2.5 kHz
テ
ー
プ
速
度
アナログ・デジタルMIXモード (SBS-10A/S使用時)
2 chモード
4 chモード
8 chモード
1 (標準速)
DC∼160 kHz
DC∼80 kHz
DC∼40 kHz
1/2
DC∼80 kHz
DC∼40 kHz
DC∼20 kHz
1/4
DC∼40 kHz
DC∼20 kHz
DC∼10 kHz
1/8
DC∼20 kHz
DC∼10 kHz
DC∼5 kHz
1/16
DC∼10 kHz
DC∼5 kHz
DC∼2.5 kHz
チャンネルモード
テ
ー
プ
速
度
!
注意
“―”部は設定不可です。
参考
フルデジタルモードについては、SBS-10A/S (別売) の取扱説明書を参照してくださ
い。
LSBデジタルチャンネルモード (BCM) の設定
SHIFTキーを押してからSPD/BCMキーを2回押し、;キーまたは:キーを押してチャ
ンネルモードを設定します。
LSBデジタルチャンネルの内部サンプリング周波数は下記のとおりです。
1 chモード
2 chモード
4 chモード
1 (標準速)
768 kHz
384 kHz
192 kHz
1/2
384 kHz
192 kHz
96 kHz
1/4
192 kHz
96 kHz
48 kHz
1/8
96 kHz
48 kHz
24 kHz
1/16
48 kHz
24 kHz
12 kHz
チャンネルモード
テ
ー
プ
速
度
参考
LSBデジタルチャンネルは、入力するデジタルデータのビットレート (繰返し周波数)
が内部サンプリング周波数よりも充分低い状態 (1/2未満) で使ってください。
5-3
テープ速度 (SPD) の設定
SPD/BCMキーを押し、;キーまたは:キーを押してテープ速度を設定します。
テープ速度に対応する記録時間は下記のとおりです。
テープ速度
記録時間 (170 mテープ)
1 (標準速)
2h
1/2
4h
1/4
8h
1/8
16 h
1/16
32 h
入力レンジ (RANGE) の設定 (アナログチャンネル)
マニュアル設定
1
RANGEキーを押すとM-RANGE (マニュアルレンジ設定) モードになります。
2
/キーまたは-キーを押してチャンネルを選択します。
3
8キーまたは9キーによって下記の入力レンジを選択します。下表の←/→は各
キーを押したときの遷移方向を示します。
8キー
←
←
←
←
←
9キー
→
→
→
→
→
RANGE表示
20
10
5
2
1
0.5
入力レンジ (Vpk)
±20
±10
±5
±2
±1
±0.5
参考
例えば、20 Vレンジとは入力電圧+20 Vpkまたは−20 Vpkもしくは±20 Vpkのとき
にバーメータスケールの±100%または0 dBとなるレンジです。他も同様です。
オート設定 (E-EまたはREC-PAUSEに設定後)
1
SHIFTキーを押してからRANGEキーを押すとA-RANGE (オートレンジ設定)
モードになります。
2
自動的に各チャンネルの入力レベルのピーク値を検出します。入力レベルと設
定レンジの関係は下記のとおりです。
3
バーメータが振れてからもう一度RANGEキーを押すと、検出されたピーク値に
対応して全チャンネルの入力レンジ値が確定されます。
参考
入力レベル
11 V以上
5.5 V以上
11 V未満
2.2 V以上
5.5 V未満
1.1 V以上
2.2 V未満
0. 55 V以上
1.1 V未満
0.55 V未満
入力レンジ
(Vpk)
±20
±10
±5
±2
±1
±0.5
入力信号に不要なDC成分が含まれるときは、次に述べる入力DCオフセットの設定を行
なってから、入力レンジの設定を行なうことをおすすめします。
5-4
入力DCオフセット (OFFSET) の設定 (アナログチャンネル)
マニュアル設定
1
OFFSETキーを押すとM-OFFSET (マニュアルオフセット設定) モードになります。
2
/キーまたは-キーを押してチャンネルを選択します。
3
8キーまたは9キーを押す毎に、+1%または−1%ずつオフセットが加わりま
す。押し続けると変化が速くなります。
4
チャンネルごとの入力DCオフセット値はテープ位置表示エリアに表示されま
す。下表の←/→は各キーを押したときの遷移方向を示します。
8キー
←
9キー
→
→
OFFSET表示
100
0
入力DCオフセット
←
−100
+100% ±0% −100%
参考
例えば、+100%オフセットとは入力レンジ±20 Vpkのときに +1.00 × 20 (V) = +20.0 (V)
のDC電圧が入力信号に重畳されて波形が上にシフトされることです。他も同様です。
オート設定
1
SHIFTキーを押してからOFFSETキーを押すとA-OFFSET (オートオフセット設
定) モードになります。
2
自動的に各チャンネルの入力信号のプラス側とマイナス側のピーク値を検出
し、DC成分の算出を行ないます。
3
3秒以上経過してからもう一度OFFSETキーを押すと、全チャンネルの入力DCオ
フセット設定が確定されます。
4
チャンネルごとの入力オフセット値はテープ位置表示エリアに表示されます。
5-5
内部時刻の設定
レコーダ内部の時刻を設定します。
2, 5
SPD/BCM
dB
%
OVR 1 1/2 1/4 1/8 1/16 1 2
SPD
AUX
EXT TC
EXP SYN
ID
(CH)
CAUTION
RANGE
M
OVR
+2
+100
0
–6
MONI
SPEED
V X1/
S- TIME
ADDRESS REMAIN T - T I M E
Y
M
D
H
M
S
0
M
A
SEARCH
OUT/TSG
(UNIT)
ID/UTL
MRK/SLF
SHIFT
3, 5
CH
-20
-40 -100
OVR
CH
RANGE
OFFSET
A
1-4 5-8
S I R -1000W
PNL LOK
9-12 13-16
PK-CLR
DATA
ALL CH SELECT
LOAD
CLOCK
VOL
PHONE
MIC
ANN/P-SV
INSTRUMENTATION DIGITAL DATA RECORDER
8
LSB DIGITAL
INPUT
D1
D2
設定できる桁が点滅
1
D3
D4
1, 4, 6
ANALOG
MONITOR
CLOCKキーをシャープペンシルの先などで1回押すと年月日設定モードとな
り、年月日の設定対象桁が点滅します。
2
/キーまたは-キーを押して設定対象桁を選択します。
3
8キーまたは9キーによって数値を選択します。
4
CLOCKキーを再度押すと時分秒設定モードとなり、時分秒の設定対象桁が点滅
します。
5
同様に/キー・-キー・8キー・9キーによって時分秒を設定します。
6
CLOCKキーをもう1回押すとレコーダ内部の時刻がスタートします。レコーダ
内部の時刻はS-TIMEにて表示され、RECモードではリアルタイムクロックとし
てテープ上に記録されます。
5-6
TSG (テスト信号) モード
E-E, REC-PAUSE, RECの各モード中にテスト信号を発生します。
本機のテスト信号はROMから読み出される16ビットのデジタルデータですので、高
精度の基準信号として使用できます。
2
SPD/BCM
EXT TC
(CH)
ON
RANGE
M
ED
ME
ME
D
S
OFFSET
A
M
A
SEARCH
OUT/TSG
(UNIT)
ID/UTL
MRK/SLF
SHIFT
PNL LOK
DATA
CLOCK
VOL
PHONE
1, 3
MIC
ANN/P-SV
R
1
SHIFTキーを押してからOUT/TSGキーを押すとTSG (テスト信号) モードになりま
す。下記のテスト信号が各チャンネルに対して入力されます。
2
;キーまたは:キーによってテスト信号の種類を選択します。選択されたテスト
信号はバーメータエリアに表示されるとともに、ANALOG MONITORコネクタ
とANALOG OUTPUTコネクタから出力されます。
EXTを選択したときは、CH 1 (SIR-1000W) およびCH 9 (SCX-16W) のINPUTコ
ネクタからの入力信号が、それぞれCH 1∼CH 8 (SIR-1000W) およびCH 9 ∼ CH
16 (SCX-16W) にテスト信号として入力されます。下表の←/→は各キーを押し
たときの遷移方向を示します。
;キー
←
←
←
←
←
:キー
→
→
→
→
→
バーメータ表示部
±100AC
+100DC
−100DC
0V
EXT
テスト信号
±100%AC
+100%DC
−100%DC
0V
外部
ACのテスト信号は設定されているテープ速度によって周波数が変わります。
テープ速度
ACテスト信号周波数
3
1 (標準速)
1/2
1/4
1/8
1/16
1 kHz
500 Hz
250 Hz
125 Hz
62.5 Hz
OUT/TSGキーをもう一度押すか、STOPキーを押すと、TSGモードが解除されま
す。
!
注意
TSGモードのまま記録を開始すると、全チャンネルにテスト信号が記録され、ANALOG
INPUTコネクタからの入力データ信号は記録されません。
5-7
5-3 データ記録
3
POWER
1
2
BATT
SPD/BCM
dB
Advanced
Intelligent
Tape
%
OVR 1 1/2 1/4 1/8 1/16 1 2
SPD
AUX
–6
MONI
REW
FF EOD
FWD
STOP
(CH)
CAUTION
REC
OVR
PAUSE
CH
RANGE
RANGE
SPEED
CH
V X1/
S- TIME
ADDRESS REMAIN T - T I M E
Y
M
D
H
M
S
0
-40 -100
BOD
ID
M
-20
LOADING
EJECT
EXT TC
EXP SYN
OVR
+2
+100
0
1-4 5-8
S I R -1000W
M
A
OUT/TSG
ID/UTL
MRK/SLF
(UNIT)
SHIFT
PNL LOK
9-12 13-16
PK-CLR
OFFSET
A
SEARCH
DATA
ALL CH SELECT
LOAD
CLOCK
VOL
PHONE
MIC
マイク
ANN/P-SV
INSTRUMENTATION DIGITAL DATA RECORDER
ANALOG
INPUT
≤ ± 100vpk
1
2
100k
3
4
5
6
7
8
LSB DIGITAL
INPUT
≤ ± 10vpk 10k
D1
D2
D3
D4
ANALOG
MONITOR
イヤホン
REF
オシロスコープ等
4
1
信号源
カートリッジをローディングします。
TOCデータ利用可能状態でない場合 (2-2項参照) はLCD画面に“TOC?”と表示
されます。TOC情報をテープTOCエリアからレコーダのメモリに読み込むため
FFキーを押してください。テープの先頭 (BOD) から記録する場合は、REWキー
を押してBODまでテープを巻き戻してください。
参考
記録のスタートごとにIDナンバーがインクリメントされ、次の記録は新しいID
ナンバーになります。また記録の開始ごとにスタートIDが付けられ、スタート
IDサーチが可能です。記録中にIDキーを押すと、IDナンバーがインクリメント
されます。これをイベントマークとして利用することによって、IDナンバーに
よりイベントサーチができます。
2
RECキーを押すとE-Eモードになります。テープにデータを記録せずに入力信号
をLCD画面でモニタできます。また、ANALOG MONITORコネクタとANALOG
OUTPUTコネクタから出力することができます。
参考
ボイスチャンネルはスピーカおよびイヤホンからはモニタできません。
3
テープ速度・チャンネルモード・入力レンジ・入力DCオフセットなどの設定を
再確認してください。
5-8
4
RECキーを押したままFWDキーを押すとRECモードになります。データ信号・
テープ位置情報・入力設定情報がテープ上に記録されます。
参考
本機ではRECモードにすると同時に入力データがFIFOメモリに入りますので、
テープ走行系の起動時間にかかわりなく、REC開始からのデータをテープ上に
記録することができます。
! 注意
• 停電などの発生が予測されるような電源環境の悪い場所で記録する場合には、
DCまたはバッテリによりバックアップしてください。
• いったん重ね書き記録を行なうと、その記録を停止した後に残っている旧デー
タは再生できなくなります。
重ね書きをする場合は、LCD画面にERA?と表示されますので、もう一度REC
キーを押しながらFWDキーを押してください。
• UTLモードのERAモードがOFFの状態のときは、LCD画面上にERA OFFと表
示され、RECモードに入りません。
モニタ
E-E, REC-PAUSE, REC, FWDの各モード中のアナログデータ信号をモニタできます。
1
BNCケーブル (別売) をANALOG MONITORコネクタに接続します。
2
/キーまたは-キーを押してモニタチャンネルを選択します。
! 注意
ANALOG MONITOR コネクタからの出力は、各ANALOG OUTPUTコネクタからの
出力と特性が異なりますので、解析用には適しません。
REC-PAUSE (記録ポーズ) モード
E-Eモード中またはRECモード中にPAUSEキーを押すとREC-PAUSE (記録ポーズ)
モードとなります。
古いデータある場合は、ERA?(erase)という警告メッセージがLCDに表示されます。
もう一度PAUSEキーを押すか、RECキーを押しながらFWDキーを押すと、重ね書き
してREC (記録) モードとなります。
古いデータを消去したくない場合は、ERA?(erase)という警告メッセージがLCDに表
示されているときにSTOPキーを押してください。
5-9
記録の停止と再開
記録を停止すると、その位置にTOCとEODが書き込まれ、EODが点灯します。
再生などをしてテープをEOD以外の位置に移動させたのち、最後の記録に続けて次
の記録を行なうときは、FFキーを押してテープがEODにあることを確認 (EOD LED
点灯) してから、RECモードにしてください。
参考
もし、記録中に電源が落ちた場合はテープ上にTOCおよびEODが書かれずに記録が
終了しますが、再度電源を投入するとLCD画面上にEOD WRT とWAITが交互に表示
され、自動的に記録の終端を探してEODを書き込みます。
IDナンバー
IDナンバーは、そのテープの最初のIDブロックに自動的に001が付けられます。記録の
開始ごとに自動的にインクリメント (1つずつ増加) します。最大値は999です。
IDナンバー
SPD/BCM
dB
%
OVR 1 1/2 1/4 1/8 1/16 1 2
SPD
AUX
EXT TC
EXP SYN
ID
RANGE
M
OVR
+2
+100
0
–6
MONI
SPEED
V X1/
S- TIME
REMAIN
ADDRESS
T- TIME
Y
M
D
H
M
S
0
RANGE
OFFSET
A
M
A
SEARCH
OUT/TSG
(UNIT)
ID/UTL
MRK/SLF
SHIFT
CH
-20
-40 -100
OVR
CH
(CH)
CAUTION
1-4 5-8
S I R -1000W
PNL LOK
9-12 13-16
PK-CLR
DATA
ALL CH SELECT
LOAD
CLOCK
VOL
PHONE
MIC
IDキー
ANN/P-SV
INSTRUMENTATION DIGITAL DATA RECORDER
記録中のIDナンバーのインクリメント
RECモード中にIDキーを1回押すとIDナンバーが1つ増えます。
参考
IDナンバーが999の記録の後に新しい記録をしたとき、またはIDキーによるインクリ
メントが行なわれたときはIDナンバーは000となります。これ以降、記録の追加など
によるIDインクリメントは行なわれず、すべてID=000のままとなります。なお、
ID=000の部分のリアルタイムクロックサーチはできません。
5-10
ADDRESS (アドレス) 表示
各記録ブロック (連続記録領域) の始まりで自動的に00H00M00Sとなります。REC
モードの開始ごとに自動的にゼロセットされます。テープ速度に応じてカウント
アップし、標準速の場合は実時間の1秒ごとにカウントアップします。
dB
%
OVR 1 1/2 1/4 1/8 1/16 1 2
SPD
AUX
EXT TC
EXP SYN
ID
CAUTION
OVR
+2
+100
0
MONI
–6
SPEED
V X1/
S- TIME
ADDRESS REMAIN T - T I M E
Y
M
D
H
M
S
0
RANGE
CH
-20
-40 -100
OVR
CH
1-4 5-8
S I R -1000W
ADDRESS表示
9-12 13-16
PK-CLR
ALL CH SELECT
LOAD
CLOCK
! 注意
RECモード中にIDキーを押してインクリメントした場合は、アドレスはゼロリセッ
トされず継続してカウントアップされます。
REMAIN (テープ残量) 表示
そのテープ速度で記録を続けたときのテープの残り時間が時分にて表示されます。
dB
%
OVR 1 1/2 1/4 1/8 1/16 1 2
SPD
AUX
EXT TC
EXP SYN
ID
CAUTION
OVR
+2
+100
0
–6
MONI
SPEED
V X1/
S- TIME
ADDRESS REMAIN T - T I M E
Y
M
D
H
M
S
0
-20
-40 -100
OVR
CH
RANGE
CH
1-4 5-8
S I R -1000W
9-12 13-16
PK-CLR
REMAIN表示
ALL CH SELECT
LOAD
CLOCK
! 注意
CMP MODE (圧縮モード) では、テープ残量表示は目安となります。
5-11
5-4 データ再生
1
BNCケーブル (別売) を用いてANALOG OUTPUTコネクタと解析機器、および
LSB DIGITAL OUTPUTコネクタと確認用機器とを接続してください。
アナログチャンネル
: 負荷インピーダンスは10 kΩ以上を推奨します。
LSBデジタルチャンネル : 負荷インピーダンスは1 kΩ以上を推奨します。
8 7 6 5 4 3 2 1
!
9
8
25
6
7
24
21
22
23
19
20
18
17
16
15
14
1
4
3
2
13
12
11
10
9
8
7
6
5
4
3
2
1
REMOTE
5
EXT. CONT
COM
AUX-2 (IRIG-B)
IN
OUT
% / dB
MST / SLV
IRIG ON / OFF
APD OFF / ON
(UP / DOWN)
SYNC
AUX-1 (DIGITAL)
IN
OUT
TRIG/REC
IN
VOLTAGE
AC FUSE
T4A
! SELECTOR
220V
RAL / HLD
9.6 / 19.2
TRG S/M
PTRG OFF/ON
240V
DC IN
STAND BY
AC IN
DC BREAKER
XLR 32F
RS
H
CANNON
OPTION SLOT 2
D4
D3
D2
OPTION SLOT 1
LSB DIGITAL
OUTPUT
D1
8
7
6
5
4
3
2
1
ANALOG
OUTPUT
1
確認用機器
解析機器
2
SPD/BCMキーでテープ速度を選択します。選択されたSPD LEDが点灯します。
3
レコーダに記録済みテープを入れてFWDキーを押すとFWD (再生) モードにな
り、テープ上のデータが再生されます。
4
記録時のテープ速度はLCD画面のSPEEDエリアに、またテープ位置情報は同じ
くテープ位置表示エリアに表示されます。
5
記録時の入力条件、 記録テープ速度も同時に再生されます。記録時の設定条件
が容易に確認できます。
2
5 4
POWER
BATT
SPD/BCM
dB
Advanced
Intelligent
Tape
%
OVR 1 1/2 1/4 1/8 1/16 1 2
SPD
AUX
–6
MONI
3
REW
FF EOD
FWD
STOP
(CH)
CAUTION
REC
OVR
PAUSE
CH
RANGE
RANGE
SPEED
CH
V X1/
S- TIME
ADDRESS REMAIN T - T I M E
Y
M
D
H
M
S
0
-40 -100
BOD
ID
M
-20
LOADING
EJECT
EXT TC
EXP SYN
OVR
+2
+100
0
1-4 5-8
S I R -1000W
M
A
OUT/TSG
ID/UTL
MRK/SLF
(UNIT)
SHIFT
PNL LOK
9-12 13-16
PK-CLR
OFFSET
A
SEARCH
DATA
ALL CH SELECT
LOAD
CLOCK
VOL
PHONE
MIC
ANN/P-SV
INSTRUMENTATION DIGITAL DATA RECORDER
ANALOG
INPUT
≤ ± 100vpk
1
2
3
100k
4
5
6
7
8
LSB DIGITAL
INPUT
≤ ± 10vpk 10k
D1
D2
D3
D4
ANALOG
MONITOR
REF
! 注意
• 記録の継目で再生信号にノイズがのる場合があります。
• SIR-1000/1000iで記録したデータは再生できません。
• 記録時の入力条件に設定されるまで、再生開始から最大約2秒かかることがありま
す。
5-12
FWD-PAUSE (再生ポーズ) モード
STOPモード中にPAUSEキーを押すと、FWD-PAUSE (再生ポーズ) モードとなりま
す。
FWD-PAUSEモードでは再生開始部分のデータがあらかじめテープから読まれ、
FIFOメモリに蓄えられますので、FWD-PAUSEモード解除と同時にデータが出力さ
れます。
このモードは、再生と同時にデータを出力させるときに使用します。
! 注意
FWD-PAUSEモード中にSTOPキーを押すと、読み込まれてFIFOメモリに蓄えられて
いるデータがクリアされます。ディスプレイには、実際のテープの位置を示す更新
されたテープのアドレスが表示されます。
モニタ
再生中のアナログデータ信号をモニタできます。
1
BNCケーブル (別売) をANALOG MONITORコネクタに接続します。
2
/キーまたは-キーを押してモニタチャンネルを選択します。
! 注意
ANALOG MONITORコネクタからの出力は、各ANALOG OUTPUTコネクタからの出
力と特性が異なりますので、解析用には適しません。
出力レベル切換 (アナログチャンネル)
OUT/TSGキーを押すとOUT (出力レベル設定) モードとなり、アナログメインチャン
ネル (CH 1∼CH 8) の出力レベルを切り換えることができます。
SPD/BCM
(CH)
RANGE
M
OFFSET
A
M
A
SEARCH
OUT/TSG
(UNIT)
ID/UTL
MRK/SLF
SHIFT
OUT/TSGキー
PNL LOK
DATA
VOL
PHONE
MIC
ANN/P-SV
8キー
→
9キー
→
→
←
←
←
5
−−
LCD表示
1
2
出力レベル
±1 Vpk
±2 Vpk
±5 Vpk マニュアル
マニュアル (連続可変) が選択されている場合は、背面パネルの出力レベル調整ボリ
ウムを時計ドライバ (付属品) で回してチャンネルごとに出力レベル (±0.5∼±5 Vpk)
を調整します。
5-13
時間軸変換再生
本機は記録時と異なるテープ速度でも再生することができます。記録されたもとの
信号の周波数を記録時と再生時のテープ速度比で変換できますので、高速のデータ
をゆっくり再生したり、長時間のデータを短時間で再生するのに便利です。記録時
のテープ速度はLCD画面上のSPEED表示エリアに表示されます。
参考
標準速よりも遅いテープ速度で記録されたテープを標準速で再生する場合、再生信
号が瞬間的に途切れる場合があります。(このとき
マークが現われます。)
これは記録時にエラーが多いと、通常以上のリトライデータがテープに残り、標準
速によるリアルタイム再生ができなくなるためです。なお、1/2速以下での再生は問
題ありません。
5-14
6 ボイスメモの記録/再生
本機は、ボイスメモをアナログデータ信号と同時に記録/再生することができます。
ボイスチャンネルの周波数帯域は下記のとおりです。
テープ速度
周波数帯域
1 (標準速)
0.2∼19.2 kHz
1/2
0.2∼9.6 kHz
1/4
0.2∼4.8 kHz
1/8
0.2∼2.4 kHz
1/16
0.2∼1.2 kHz
なお、本機のスピーカの周波数帯域は0.2∼5 kHzです。
! 注意
ボイスチャンネルはメモ音声用ですので、解析用には適しません。
マイク・イヤホンの接続
1
マイク (付属品) を正面パネルのMICジャックに接続します。
2
イヤホン (市販品) を正面パネルのPHONEジャックに接続します。
POWER
BATT
SPD/BCM
dB
Advanced
Intelligent
Tape
%
OVR 1 1/2 1/4 1/8 1/16 1 2
SPD
AUX
MONI
–6
REW
FF EOD
FWD
STOP
(CH)
CAUTION
REC
OVR
PAUSE
CH
RANGE
RANGE
SPEED
CH
V X1/
S- TIME
ADDRESS REMAIN T - T I M E
Y
M
D
H
M
S
0
-40 -100
BOD
ID
M
-20
LOADING
EJECT
EXT TC
EXP SYN
OVR
+2
+100
0
1-4 5-8
S I R -1000W
M
A
OUT/TSG
ID/UTL
MRK/SLF
(UNIT)
SHIFT
PNL LOK
9-12 13-16
PK-CLR
OFFSET
A
SEARCH
DATA
ALL CH SELECT
LOAD
CLOCK
VOL
PHONE
MIC
マイク
ANN/P-SV
INSTRUMENTATION DIGITAL DATA RECORDER
ANALOG
INPUT
≤ ± 100vpk
1
2
3
100k
4
5
6
7
8
LSB DIGITAL
INPUT
≤ ± 10vpk 10k
D1
D2
D3
D4
ANALOG
MONITOR
REF
イヤホン
6-1
ボイスメモの記録
1
マイク左側スイッチを押すとON、離すとOFFになりますので、必要な音声のみ
を記録することができます。
2
マイク入力レベルに応じてMIC (マイク) LEDの輝度が変わります。
参考
1. 記録レベルは本機のAGC機能によって自動的に調節されます。
2. RECモード中またはイヤホン使用中はスピーカからの音声の出力はありません。
ボイスメモの再生
• ANN/P-SVキーを押してANN LEDを点灯させると、テープに記録されたボイスメ
モがスピーカ (PHONEジャック使用時はイヤホン) から再生されます。音量はVOL
つまみで調整します。
参考
• ANN/P-SVキーを押してDATA LEDを点灯させると、モニタチャンネルのデータ信
号が音声としてスピーカまたはイヤホンから再生されます。
• 記録時と再生時のテープ速度が異なると、ボイスメモのピッチ (信号周波数) がも
とのピッチと異なります。
• ボリウムを絞ってもMIC LEDの点灯で音声の有無が確認できます。
6-2
7 AUXデジタルデータの記録/再生
本機は、AUXデジタルデータ信号をアナログデータ信号と同時に記録/再生すること
ができます。
AUXデジタルデータ信号として、回転パルスやトリガパルスの様な信号を記録/再生
することができます。
• AUXデジタルチャンネルの内部サンプリング周波数は下記のとおりです。
テープ速度
サンプリング周波数
Ts
1 (標準速)
384 kHz
約6μs
1/2
192 kHz
約12μs
1/4
96 kHz
約25μs
1/8
48 kHz
約50μs
1/16
24 kHz
約100μs
表7-1
AUXデジタルチャンネルで記録する信号には、以下の条件を推奨します。
Ts
Tr
Ts
Tf
: 最小ホールド時間
(表7-1参照)
Tr/Tf : レベル遷移時間
(テープ速度にかかわらず
100μs)
Ts
• サンプリングにより記録された信号には、原信号に対し、立ち上がり/立ち下がり
位相が最大サンプリング1周期分のジッターが発生します。この影響が無視できる
程度の入力周波数範囲でお使いください。
Input
fi
d1
d2
d3
d4
Int Clock
fs
Output
fo
fi
fs
fo
d1∼d4
:
:
:
:
入力波形
サンプリング波形 (内部クロック)
出力波形
位相ずれ (ジッター)
サンプリングによる位相ずれの例
7-1
AUXデジタルデータの接続
BNCケーブル (別売) を用いて背面パネルのAUX-1 (DIGITAL) INコネクタと信号源
とを接続してください。
必要に応じ、BNCケーブルを用いて背面パネルのAUX-1 (DIGITAL) OUTコネクタに
確認用の機器を接続してください。
E-E、REC-PAUSEまたはRECの各モードにおいてAUXデジタルデータが入力されて
いる (High, Lowの繰返しが一定期間内に起こる) ときは、ディスプレイ上のAUX-1
のLEDが点灯します。点灯しない場合は、ケーブルなどの接続を確認してくださ
い。
9
8
25
6
7
24
21
22
23
19
20
18
17
16
15
14
1
4
3
2
13
12
11
10
9
8
7
AUX-2 (IRIG-B)
IN
OUT
SYNC
AUX-1 (DIGITAL)
IN
OUT
TRIG/REC
IN
! SELECTOR
!
5
6
5
4
3
2
1
REMOTE
COM
VOLTAGE
AC FUSE
T4A
8 7 6 5 4 3 2 1
EXT. CONT
220V
RAL / HLD
9.6 / 19.2
TRG S/M
PTRG OFF/ON
% / dB
MST / SLV
IRIG ON / OFF
APD OFF / ON
(UP / DOWN)
240V
DC IN
STAND BY
AC IN
DC BREAKER
XLR 32F
S
HR
CANNON
OPTION SLOT 2
D4
D3
D2
OPTION SLOT 1
D1
LSB DIGITAL
OUTPUT
ANALOG
8
7
6
5
4
3
2
1 OUTPUT
信号源
確認用機器
! 注意
• アナログデータ信号とグランドレベルの異なる信号を同時に入力しないでください。
• 入出力レベルはTTLです。
AUXデジタルデータ信号の記録
記録を開始すると、AUXデジタルチャンネルに入力されているAUXデジタルデータ
信号がメインデータ信号と同時にテープ上に記録されます。
また、入力信号を検知すると、LCD画面上のAUX 1のLEDが点灯します。
AUXデジタルデータ信号の再生
AUXデジタルデータ信号が記録されたテープを再生すると、AUXデジタルデータ信
号が背面パネルのAUX-1 (DIGITAL) OUTコネクタから出力されます。
また、再生信号を検知すると、LCD画面上のAUX 1のLEDが点灯します。
7-2
8 AUXアナログデータの記録/再生
本機は、メインアナログチャンネル (本体のみの場合8 ch) の他に、サブアナログチャ
ンネルとしてAUX-2 (IRIG-B) チャンネルを装備しており、AUXアナログデータ信号
をメインアナログデータ信号と同時に記録/再生することができます。
AUXアナログチャンネルの周波数帯域は下記のとおりです。
テープ速度
周波数帯域
1 (標準速)
DC∼19.2 kHz
1/2
DC∼9.6 kHz
1/4
DC∼4.8 kHz
1/8
DC∼2.4 kHz
1/16
DC∼1.2 kHz
AUXアナログデータ信号としては、一般のアナログ信号の他に、IRIG-Bフォーマッ
トのタイムコード信号などが使用できます。
8-1
8-1 IRIG-Bタイムコード信号の記録/再生
IRIG-Bタイムコード信号系の接続
接続できるIRIG-Bタイムコード信号は下記のとおりです。
コード
: 振幅変調コード (ACコード)
搬送周波数 : 1 kHz
電圧範囲
: ±1∼±10 Vpk
変調振幅比 : 1:3
8 7 6 5 4 3 2 1
IRIG ON/OFF
9
8
25
6
7
24
21
22
23
19
20
18
17
16
15
14
1
SYNC
4
3
2
13
AUX-1 (DIGITAL)
IN
OUT
TRIG/REC
IN
! SELECTOR
!
5
12
COM
11
10
9
8
7
AUX-2 (IRIG-B)
IN
OUT
VOLTAGE
AC FUSE
T4A
8 7 6 5 4 3 2 1
6
5
4
3
2
1
EXT. CONT
REMOTE
220V
RAL / HLD
9.6 / 19.2
TRG S/M
PTRG OFF/ON
% / dB
MST / SLV
IRIG ON / OFF
APD OFF / ON
(UP / DOWN)
240V
DC IN
STAND BY
AC IN
DC BREAKER
XLR 32F
RS
H
CANNON
OPTION SLOT 2
D4
D3
D2
OPTION SLOT 1
D1
LSB DIGITAL
OUTPUT
8
7
6
5
4
3
2
1
ANALOG
OUTPUT
タイムコードゼネレータ
タイムコードリーダ
1
背面パネルのデジタルスイッチIRIG ON/OFFを上に倒してONにします。
2
BNCケーブル (別売) を用いて、背面パネルのAUX-2 (IRIG-B) INコネクタにIRIGタ
イムコードゼネレータなどからのIRIG-Bタイムコード信号を接続してください。
必要に応じ、BNCケーブル (別売) を用いて、背面パネルのAUX-2 (IRIG-B) OUT
コネクタにIRIGタイムコードリーダを接続してください。
! 注意
デジタルスイッチIRIG ON/OFFがOFFになっていると、IRIG-Bタイムコード信号と
して正しく検知されません。
8-2
IRIG-Bタイムコード信号の記録
E-E、REC-PAUSEまたはRECの各モードにおいて、レコーダ本体にIRIG-Bタイム
コード信号が入力され、正しく検知されるとEXT TC LEDが点灯します。また、テー
プ表示エリアに“001”が表示され点滅を始めます。レコーダ内部のリアルタイムク
ロックに同期すると、リアルタイムクロックにIRIG-Bタイムコードがロードされま
す。
記録を開始すると、AUXアナログチャンネルに入力されている生のIRIG-Bタイム
コード信号がメインデータと同時にテープ上に記録されます。
また、IRIGタイムはS-TIME情報 (xxY xxM xxD および xxH xxM xxS) となってメイ
ンデータと同時にテープ上に記録されます。サーチ・再生・データ転送のとき、正
確な位置情報として使用できます。
参考
• IRIG-Bタイムコード信号をレコーダ本体が検知し、AUX2 LEDが点灯するまでに
は、最大5秒間かかります。また1分に1回の同期をとるため、EXT TC LEDが点灯
するまでは、最大1分かかります。
• 正しく検知されたIRIG-Bタイムコード信号は3桁の日数 (001∼366) が“―Y xxM
xxD”(平年) に変換され、記録時点におけるレコーダ内部時刻の年次値“xxY”と
組み合わされてS-TIME情報 (xxY xxM xxD) となります。
• いったんIRIGタイムがロードされた内部時刻は、IRIG-Bタイムコード信号の入力
がなくなっても、そのまま水晶精度で計時を続けます。
• AUX2の出力はE-E、STOPに関係なく信号を入力すれば出力されます。
IRIG-Bタイムコード信号の再生
IRIG-Bタイムコード信号がAUX-2 (IRIG) チャンネル記録されたテープを再生する
と、EXT TC LEDが点灯します。
また、テープ上に記録された生のIRIG-Bタイムコード信号が背面パネルのAUX-2
(IRIG-B) OUTコネクタから出力されますので、IRIGタイムコードリーダで読むこと
ができます。
再生中のテープ位置表示エリアのT-TIME情報は、テープ上に記録されたレコーダ内
部時刻の値 (xxY xxM xxD および xxH xxM xxS) が表示されます。この値はテープ上
に記録されたIRIGタイムの時刻と同一です。
8-3
8-2 AUXアナログデータの記録/再生
AUXアナログデータ信号系の接続
8 7 6 5 4 3 2 1
IRIG ON/OFF
8 7 6 5 4 3 2 1
!
9
8
25
6
7
24
21
22
23
19
20
18
17
16
15
14
1
4
3
2
13
12
11
10
9
8
7
6
5
4
3
2
1
REMOTE
5
EXT. CONT
COM
AUX-2 (IRIG-B)
IN
OUT
SYNC
AUX-1 (DIGITAL)
IN
OUT
TRIG/REC
IN
% / dB
MST / SLV
IRIG ON / OFF
APD OFF / ON
(UP / DOWN)
VOLTAGE
AC FUSE
T4A
! SELECTOR
220V
RAL / HLD
9.6 / 19.2
TRG S/M
PTRG OFF/ON
240V
DC IN
STAND BY
AC IN
DC BREAKER
XLR 32F
S
HR
CANNON
OPTION SLOT 2
D4
D3
D2
OPTION SLOT 1
D1
LSB DIGITAL
OUTPUT
8
7
6
5
4
3
2
1
ANALOG
OUTPUT
アナログ信号源
確認用機器
1
背面パネルのデジタルスイッチIRIG ON/OFFを下に倒してOFFにします。
2
BNCケーブル (別売) を用いて、背面パネルのAUX-2 (IRIG-B) INコネクタにAUX
アナログ信号源からのAUXアナログデータ信号を接続してください。
必要に応じ、BNCケーブル (別売) を用いて、背面パネルのAUX-2 (IRIG-B) OUT
コネクタに確認用機器を接続してください。
AUXアナログデータが入力されているときは、ディスプレイ上のAUX-2 LEDが
点灯します。点灯しない場合はケーブルなどの接続を確認してください。
! 注意
• デジタルスイッチIRIG ON/OFFがONになっていると、AUXアナログ入力信号に
AGCがかかります。
• AUXアナログデータ信号の入力レベルは定格±2 Vpkです。
最大約±3 Vpkまで入力可能です。
AUXアナログデータ信号の記録
記録を開始すると、AUXアナログチャンネルに入力されているAUXアナログデータ
信号がメインデータ信号と同時にテープ上に記録されます。
AUXアナログデータ信号の再生
AUXアナログデータ信号が記録されたテープを再生すると、AUXアナログデータ信
号が背面パネルのAUX-2 (IRIG-B) OUTコネクタから出力されます。
8-4
9 トリガ記録の取扱方法
トリガ信号系の接続
1
背面パネルのデジタルスイッチTRG S/Mを目的に応じてSまたはMに設定してく
ださい。
記録ポーズ状態のとき、Sのポジションにした場合はトリガ入力信号がHighから
Lowになると記録を開始し、STOPキーが押されるまで記録を続けます。
Mのポジションにした場合はトリガ入力信号がLowになると記録を開始し、High
になると記録ポーズ状態になります。
2
BNCケーブル (別売) を用いて背面パネルのTRIG INコネクタとトリガ信号源と
を接続してください。
8 7 6 5 4 3 2 1
TRG S/M
PTRG OFF/ON
9
8
25
6
7
24
21
22
23
19
20
18
17
16
15
14
1
4
3
2
13
12
11
10
9
8
7
AUX-2 (IRIG-B)
IN
OUT
SYNC
AUX-1 (DIGITAL)
IN
OUT
TRIG/REC
IN
! SELECTOR
!
5
6
5
4
3
2
1
REMOTE
COM
VOLTAGE
AC FUSE
T4A
8 7 6 5 4 3 2 1
EXT. CONT
220V
RAL / HLD
9.6 / 19.2
TRG S/M
PTRG OFF/ON
% / dB
MST / SLV
IRIG ON / OFF
APD OFF / ON
(UP / DOWN)
240V
DC IN
STAND BY
AC IN
DC BREAKER
XLR 32F
S
HR
CANNON
OPTION SLOT 2
D4
D3
D2
OPTION SLOT 1
D1
LSB DIGITAL
OUTPUT
8
7
6
5
4
3
2
1
ANALOG
OUTPUT
信号源
!
注意
ADDRESSの時間表示が2秒未満の場合は、次の記録が開始されないことがありま
す。
参考
入力電圧レベルはTTLレベルにしてください。
9-1
トリガ記録
本体をREC-PAUSEモードに設定しておくと、トリガ信号源からのトリガ信号、または
PAUSEキーを押してREC-PAUSEを解除することにより、レコーダが記録を開始します。
プリトリガモード (PTRG OFF/ON=ON) では、プリトリガ時間 (トリガ前のデータ長)
がテープスピードに応じて3秒、6秒、12秒、24秒または48秒に設定されます。標準
のトリガモード (PTRG OFF/ON=OFF)では、データはトリガ直後に記録されます (プ
リトリガ時間=0)。
参考
トリガ信号の入力以前に、REC-PAUSEモードをプリトリガの時間分保持しないと、
プリトリガデータ全部を記録することはできません。記録テープ速度を1/2, 1/4, ...と
するとプリトリガデータはそれぞれ6秒, 12秒, ...となります。
プリトリガデータの再生
再生時はプリトリガデータ部分のADDRESSは-00H00M00Sと表示されます。
9-2
10 サーチ
サーチ機能を使うとターゲットのデータに早くアクセスできます。
本機のサーチには下記の種類があります。
コントロール可否
サーチ種類
正面パネル
リモートコントロールユニット
ホストコンピュータ
ID
○
○
×
IDナンバー
○
×
○
スタートID
○
×
○
EOD
○
○
○
MRK (マーク)
○
×
×
アドレス
×
×
○
リアルタイムクロック
またはIRIGタイム
×
×
○
IDナンバーサーチおよびMRKサーチモード中のLED表示は下記のとおりです。
LED
サーチ動作
SEARCH
IDナンバー
MRK/SLF
SEARCHキー押下
点灯
点滅
点滅
サーチ中
点滅
FOUND (正常終了)
消灯
NOT FOUND
(対象未発見)
点滅
選択されたモードのLEDが点灯
消灯
消灯
選択されたモードのLEDが点滅
サーチを中断するときはSTOPキーを押します。
参考
TOCデータ利用可能状態でない場合 (2-2項参照) にサーチ動作に入ろうとするとLCD
画面にTOC?と表示されます。FFキーを押してTOCデータを読み込んだ後にサーチを
行なってください。
IDサーチ
再生 (FWD) 中にFFキーまたはREWキーを押すと、次のIDブロックの先頭または現
在のIDブロックの先頭をサーチして、そこから再生します。
POWER
BATT
SPD/BCM
dB
Advanced
Intelligent
Tape
%
OVR 1 1/2 1/4 1/8 1/16 1 2
SPD
AUX
–6
FF EOD
FWD
STOP
RANGE
MONI
REC
OVR
PAUSE
CH
REWキー
RANGE
SPEED
CH
V X1/
S- TIME
ADDRESS REMAIN T - T I M E
Y
M
D
H
M
S
0
-40 -100
REW
(CH)
CAUTION
M
-20
BOD
ID
+2
+100
0
LOADING
EJECT
EXT TC
EXP SYN
OVR
1-4 5-8
S I R -1000W
M
A
SEARCH
OUT/TSG
ID/UTL
MRK/SLF
(UNIT)
SHIFT
PNL LOK
9-12 13-16
PK-CLR
OFFSET
A
DATA
ALL CH SELECT
LOAD
CLOCK
VOL
PHONE
MIC
ANN/P-SV
INSTRUMENTATION DIGITAL DATA RECORDER
FFキー
STOPキー
ANALOG
INPUT
≤ ± 100vpk
1
2
3
100k
4
5
6
7
8
LSB DIGITAL
INPUT
≤ ± 10vpk 10k
D1
D2
D3
D4
ANALOG
MONITOR
REF
例 : ID100ブロックの部分を再生中にFFキーを押すと次のIDブロック (通常は101) の
先頭を、またREWキーを押すと現在のIDブロック (100) の先頭をサーチして、そ
こから再生します。
10-1
IDナンバーサーチ
ターゲットのIDナンバーを設定して、その先頭をサーチします。
1
SPD/BCM
(CH)
RANGE
OFFSET
M
A
M
2
A
SEARCH
OUT/TSG
(UNIT)
ID/UTL
MRK/SLF
SHIFT
1, 3
PNL LOK
DATA
VOL
PHONE
MIC
ANN/P-SV
1
STOPモード中にSAERCHキーを押してからIDキーを押すとIDサーチモードにな
ります。
2
;キー・:キー・8キー・9キーでターゲットのIDナンバーを設定します。
3
再度IDキーを押すとターゲットのIDをサーチして停止します。
スタートIDサーチ
各記録ごとの開始位置にあるスタートIDをサーチします。
• STOPモード中にSEARCHキーを押してからFFキーを押すと、現在位置の次の記録
の開始位置にスキップして停止します。
• STOPモード中にSEARCHキーを押してからREWキーを押すと、現在の記録の開始
位置に戻って停止します。
SEARCHキー
POWER
BATT
SPD/BCM
dB
Advanced
Intelligent
Tape
%
OVR 1 1/2 1/4 1/8 1/16 1 2
SPD
AUX
–6
MONI
REW
FF EOD
FWD
STOP
(CH)
CAUTION
REC
OVR
PAUSE
CH
REWキー
RANGE
RANGE
SPEED
CH
V X1/
S- TIME
ADDRESS REMAIN T - T I M E
Y
M
D
H
M
S
0
-40 -100
BOD
ID
M
-20
LOADING
EJECT
EXT TC
EXP SYN
OVR
+2
+100
0
1-4 5-8
S I R -1000W
M
A
OUT/TSG
ID/UTL
MRK/SLF
(UNIT)
SHIFT
PNL LOK
9-12 13-16
PK-CLR
OFFSET
A
SEARCH
DATA
ALL CH SELECT
LOAD
CLOCK
VOL
PHONE
MIC
ANN/P-SV
INSTRUMENTATION DIGITAL DATA RECORDER
FFキー
ANALOG
INPUT
≤ ± 100vpk
1
REF
10-2
2
3
100k
4
5
6
7
8
LSB DIGITAL
INPUT
≤ ± 10vpk 10k
D1
D2
D3
D4
ANALOG
MONITOR
EODサーチ
EODをサーチします。前回の記録の終端に続けて新しいデータの記録を始めるとき
に便利です。
FFキーを押すとテープが早送りされ、EODで停止します。EOD LEDが点灯します。
POWER
BATT
Advanced
Intelligent
Tape
LOADING
EJECT
BOD
REW
FF EOD
FWD
STOP
REC
PAUSE
EOD LED
FFキー
MRK (マーク) サーチ
任意のテープ位置でMRK/SLFキーを押すと、後でその場所をサーチすることができ
ます。
SPD/BCM
(CH)
RANGE
M
OFFSET
A
M
A
SEARCH
OUT/TSG
(UNIT)
ID/UTL
MRK/SLF
SHIFT
PNL LOK
DATA
VOL
PHONE
MIC
2
1, 2
ANN/P-SV
1
RECモードまたはFWDモード中にMRK/SLFキーを押すと、その箇所のテープ位
置情報がレコーダ内のメモリに記憶され、次にMRK/SLFキーを押すまで保持さ
れます。
2
SEARCHキーを押してからMRK/SLFキーを押すとマークサーチモードになり、
ターゲットをサーチして停止します。
参考
• MRK/SLFキーを押すごとにテープ位置情報は更新されます。
• 遅いテープ速度 (1/4, 1/8, 1/16) の場合、マークした点とターゲットがリアルタ
イムクロック値で最大3秒ずれることがあります。
10-3
アドレスサーチ
ターゲットのアドレス値をサーチします。ホストコンピュータからRS-232Cコマンド
によってコントロールします。
リアルタイムクロックサーチ
テープ上に書かれたターゲットのリアルタイムクロック値をサーチします。ホスト
コンピュータからRS-232Cコマンドによってコントロールします。
10-4
11 EXT.コントロールの取扱方法
本機は、EXT. CONTコネクタからTTLレベルのコントロール信号を入力することに
よって、簡単に操作できます。
機能
指令機能 (入力)
レコーダ本体に対して以下の指令を入力することができます。
• テープ走行モード設定
• IDインクリメント
確認機能 (出力)
レコーダ本体から以下の状態を出力することができます。
• ローディング状態
• テープ走行モード
• 警告メッセージ
• BOD, EOD, EOT
インターフェース
14
1
25
13
コネクタ : 角形、D-sub 25 pin
入力
: TTLレベル、パルス幅100 ms以上、Pin 1または15 (GND)との短絡による
出力
: TTLレベル出力、シンク電流20 mA max.
コネクタピンアサイン
ピン番号
信号名
機能
I/O
ピン番号
信号名
機能
I/O
1
GND
GND
―
14
+5V
補助電源
O
2
+5V
補助電源
O
15
GND
GND
―
3
BOD
BOD
O
16
RSV
未使用
―
4
EOD
EOD
O
17
RSV
未使用
―
5
ALARM
警告メッセージ
O
18
RSV
未使用
―
6
EOT
EOT
O
19
IDINC
IDインクリメント
I
7
LOADING
ローディング
O
20
IPAUSE
PAUSE
I
8
OPAUSE
PAUSE
O
21
IREC
REC
I
9
OREC
REC
O
22
ISTOP
STOP
I
10
OSTOP
STOP
O
23
IFWD
FWD
I
11
OFWD
FWD
O
24
IFF
FF
I
12
OFF
FF
O
25
IREW
REW
I
13
OREW
REW
O
参考
ALARM : DC低電圧、結露、メカ異常、記録/再生エラーの発生時に出力
+5V
: 外部LED点灯用など、Pin 2と14合わせて100 mA max.
11-1
入出力インターフェース回路
SIR-1000W
10 kΩ
15 Ω
47 pF
M6650
15 Ω
M6650
入出力論理
Highレベル
Lowレベル
パルス幅
11-2
:
:
:
:
15 Ω
15 Ω
47 pF
負論理
+3.5 V以上 
 EXT. CONTコネクタ端子における電圧
+1.5 V以上 
100 ms以上
IN
EXT. CONT
コネクタ
OUT
12 RS-232Cによるコントロール
本機の背面パネルにあるCOMコネクタ (D-sub 9 pin) はRS-232Cに準拠した信号フォー
マットになっていますので、RS-232Cケーブル (市販) を接続することによって、ホ
ストコンピュータからのコントロールが行なえます。
! 注意
• RS-232Cケーブルはシールドされたものをお使いください。
RS-232Cによりレコーダをコントロールする場合は、ERR?, ALM?コマンドを用い
てレコーダの状態を監視することをおすすめします。
• RS-232CによりRECモードにすると、記録開始から約1秒間記録されません。
12-1 インターフェース仕様
9
5
信号フォーマット : EIA RS-232C準拠
6
1
コネクタ型式
: 角形、D-sub 9 pin
伝送レート
: 9.6/19.2 kbps (切換)、非同期
キャラクタ長
: 8 bit
パリティビット
: なし
ストップピット
: 1 bit
フロー制御
: あり (CTS/RTS : ハードウェアフロー制御)
コネクタピンアサイン
ピン番号
信号名
機能
I/O
1
RSV
未使用
―
2
RD
受信データ
I
3
TD
送信データ
O
4
RSV
未使用
―
5
GND
GND
―
6
RSV
未使用
―
7
RTS
送信要求
O
8
CTS
送信可
I
9
RSV
未使用
―
12-1
12-2 コマンド概要
設定コマンド
ホストコンピュータからレコーダ本体に対して出力できる設定コマンドは下記のと
おりです。
機能
コマンド
12-2
備考
BAR :
バーメータコントロール
CAL :
キャリブレーション
CHA :
チャンネルモード設定
FMT :
テープフォーマット設定
IDS :
IDインクリメント
INP :
入力形式設定
SIR-1000iのみ
LCH :
LSBデジタルチャンネル設定
SIR-1000Wのみ
MEM :
メモ文字列の設定
MOD :
テープ走行モード設定
MON :
モニタチャンネル選択
OFS :
DCオフセット設定
OFA :
オートオフセット設定
OPL :
出力レベル選択
PNL :
パネルロック
PSV :
パワーセーブ
RNA :
オートレンジ設定
RNG :
入力レンジ設定
RPT :
オートリピート設定
SCH :
サーチ
SLF :
セルフチェック
SPD :
テープ速度設定
SPO :
スピーカソース切換
TIM :
リアルタイムクロック設定
TRG :
トリガモード設定
TRM :
ターミネータの選択
TSG :
テスト信号の選択
UTL :
ユーティリティモード設定
STOP時のみ
ステータスコマンド
ホストコンピュータからの要求を受けてレコーダ本体が返送できる設定値またはス
テータス内容は下記のとおりです。
コマンド
機能
備考
ADR?
テープアドレス
ALM?
アラームステータス
AUX?
フロントパネルステータス
BAR?
バーメータ設定読み出し
BAT?
バッテリステータス
CAL?
キャリブレーションステータス
CHA?
チャンネルモード設定読み出し
CFG?
レコーダ構成
CMD?
コマンドチェック
ERR?
エラーチェック
FMT?
フォーマット実行ステータス
IDS?
テープIDナンバー読み出し
INP?
入力形式読み出し
SIR-1000iのみ
LCH?
LSBデジタルチャンネル読み出し
SIR-1000Wのみ
LVA?
信号レベル読み出し
(テキストフォーマット)
LVB?
信号レベル読み出し
(バイナリフォーマット)
MAP?
スレーブID読み出し
MEM?
メモ文字列読み出し
MOD?
テープ走行モード読み出し
MON?
モニタチャンネル設定読み出し
OFA?
オートオフセット設定ステータス
OFS?
DCオフセット値読み出し
OPL?
出力レベル設定読み出し
PNL?
パネルロックステータス読み出し
PSV?
パワーセーブステータス
RNA?
オートレンジ設定ステータス読み出し
RNG?
レンジ設定値の読み出し
RPT?
オートリピートステータス読み出し
SCH?
サーチステータス
SLF?
セルフチェックステータス
SPD?
テープ速度読み出し
SPO?
スピーカソース切換ステータス
STA?
ステータスA
TIM?
リアルタイムクロック読み出し
TOC?
TOCデータ読み出し
TRG?
トリガモード設定ステータス
TRM?
ターミネータの選択ステータス
(返信ストリングス)
TSG?
テスト信号の選択ステータス
UTL?
ユーティリティモード設定読み出し
VOL?
テープボリュームの読み出し
12-3
12-3 コマンド詳細
設定コマンド
コマンドはすべてアスキコードを使用します。1つのコマンドはLF (Line Feed), CR
(Carriage Return), またはCR+LFで終了します。
< > はコマンドのパラメータで、1文字の英数字を表わします。
/ [ ] 同期運転のように複数台のレコーダが接続されている場合、個々のレコーダを指定し
てコマンドを与えることができます。/ [ ]パラメータはどれか1つのID番号を指定します。
1台のレコーダのみの接続、または0番のレコーダに対してはこの指定を省略できます。
2台で同期運転している場合は、マスター機がID=0, スレーブ機がID=1になります。
コマンド
12-4
内容
BAR :
コマンド形式
バーメータコントロール
BAR : <1><2> / [ ]
<1> : 0=リアルタイムモード, 1=ピークホールドモード
<2> : 0=片振れモード, 1=両振れモード
ex) BAR : 01
− リアルタイムおよび両振れモードを設定
BAR : 11/1
− ピークホールドおよび両振れモードをレコーダの
MASTER=0, SLAVE=1に設定
関連コマンドBAR?
CAL :
コマンド形式
キャリブレーション
CAL : <1> / [ ]
<1> : 0=キャリブレーション中止, 1=キャリブレーション開始
結果はCAL? によって見ることができる
関連コマンドCAL?
CHA :
コマンド形式
チャンネルモード設定
CHA : <1><2> / [ ]
<1> : アナログチャンネルコード
<2> : デジタルチャンネルコード
0=OFF
0=OFF
1=RSV
1=1ch (Async)
2=RSV
2=2ch (Async)
3=RSV
3=4ch (Async)
4=RSV
4=8ch (Async)
5=16ch (SIR-1000/1000i)
5=RSV
6=32ch (SIR-1000/1000i)
6=RSV
7=64ch (SIR-1000/1000i)
7=RSV
8=128ch (SIR-1000/1000i)
8=RSV
9=RSV
9=RSV
A=RSV
A=1ch (Sync)
B=2ch (SIR-1000W)
B=2ch (Sync)
C=4ch (SIR-1000W)
C=4ch (Sync)
D=8ch (SIR-1000W)
D=8ch (Sync)
E=16ch (SIR-1000W)
E=RSV
F=RSV
F=RSV
参考 アナログとデジタルのチャンネルモードで組み合わせに制限がありますので、
SBS-10A/Sの取扱説明書を参照してください。
SBS-10Aモード時はデジタルチャンネルの設定が可能です。
関連コマンドCHA?
FMT :
コマンド形式
テープフォーマッティング
FMT : <1><2><3><4> / [ ]
<1> : 0=RSV, 1=フォーマッティング開始
<2><3><4> : フォーマッティング時のIDナンバー (001∼999)
注意 このコマンドによって記録済みのデータがすべて論理的に消去されます。
関連コマンドFMT?
IDS :
コマンド形式
IDインクリメント
IDS : <1>
<1> : 0=RSV, 1=IDインクリメント
コマンドIDS : 1が発行される毎にレコーダのIDがインクリメントされる。
関連コマンドIDS?
コマンド
内容
INP : (SIR-1000/1000iのみ) 入力形式設定
コマンド形式
INP : <1><2>... <17> / [ ]
<1> : チャンネル拡張ユニットID番号
0=本体
1=チャンネル拡張ユニット1
2=チャンネル拡張ユニット2
3=チャンネル拡張ユニット3
4=チャンネル拡張ユニット4
5=チャンネル拡張ユニット5
6=チャンネル拡張ユニット6
7=チャンネル拡張ユニット7
<2> : CH1の入力形式
0=DIRECT
1=SENSOR
<3> : CH2の入力形式
.
.
.
<17> : CH16の入力形式
関連コマンドINP?
LCH :
(SIR-1000Wのみ)
コマンド形式
LSBデジタルチャンネル設定
LCH : <1> / [ ]
<1> : 0=OFF
1=1 ch
2=2 ch
3=4 ch
参考
関連コマンドLCH?
MEM :
コマンド形式
メモ文字列設定
MEM : <1><2>...<96> / [ ]
<1><2>...<96> 最大96文字までのアスキーキャラクタ (20h - FFhex)
ex) MEM:MEASUREMENT-1 − (“MEASUREMENT-1”というメモ文字の設定)
関連コマンドMEM?
MOD :
コマンド形式
テープ走行モード設定
MOD : <1> / [ ]
<1> : 0=STOP, 1=FWD, 2=E-E, 3=REC, 4=FWD-PAUSE, 5=REC-PAUSE, 6=FF, 7=RSV,
8=REW, 9=RSV, A=EJECT
ex) MOD : 1 − FWD
関連コマンドMOD?
MON :
コマンド形式
モニタチャンネル選択
MON : <1><2> / [ ]
<1> : チャンネル拡張ユニットID番号
0=本体
1=チャンネル拡張ユニット1
2=チャンネル拡張ユニット2
3=チャンネル拡張ユニット3
4=チャンネル拡張ユニット4
5=チャンネル拡張ユニット5
6=チャンネル拡張ユニット6
7=チャンネル拡張ユニット7
<2> :チャンネルコード
0=CH1
1=CH2
2=CH3
3=CH4
4=CH5
5=CH6
6=CH7
7=CH8
8=CH9
9=CH10
A=CH11
B=CH12
C=CH13
D=CH14
E=CH15
F=CH16
関連コマンドMON?
OFA :
コマンド形式
オートオフセット設定
OFA : <1><2> / [ ]
<1> : RSV (常に0)
<2> : 0=DCオフセット計測中止&設定, 1=オフセット計測開始
関連コマンドOFA?
12-5
コマンド
OFS :
コマンド形式
内容
DCオフセット設定
OFS : <1><2>...<33> / [ ]
<1> : チャンネル拡張ユニットID番号 (0=本体)
<2><3> : CH1のDCオフセット
<4><5> : CH2のDCオフセット
.
.
.
<32><33> : CH16のDCオフセット
DCオフセット値は2桁の16進数で表わす。
ex) OFS : 000100022334500FFCE2345220034A1FB
00 : 0%
01 : 1%
10 : 16%
32 : 50%
64 : 100%
FF : −1%
CE :−50%
9C : −100%
関連コマンドOFS?
OPL :
コマンド形式
出力レベル選択
OPL : <1><2>...<17>
<1> : チャンネル拡張ユニットID番号 (0=本体)
<2> : CH1の出力レベルコード
<3> : CH2の出力レベルコード
.
.
.
<17> : CH16の出力レベルコード
出力レベルコード
0=RSV, 1=RSV, 2=5V, 3=2V, 4=1V, 5=RSV, 6=RSV, 7=RSV, 8=RSV, 9=RSV, A=マニュアル
関連コマンドOPL?
PNL :
コマンド形式
パネルロック
PNL : <1> / [ ]
<1> : 0=パネルロック解除, 1=パネルロック設定
関連コマンドPNL?
PSV :
コマンド形式
パワーセーブ
PSV : <1> / [ ]
<1> : 0=パワーセーブ解除, 1=パワーセーブ設定
関連コマンドPSV?
RNA :
コマンド形式
オートレンジ設定
RGA : <1><2> / [ ]
<1> : RSV (常に0)
<2> : 0=レンジ計測中止&設定, 1=レンジ計測開始
関連コマンドRNA?
RNG :
コマンド形式
入力レンジ設定
RNG : <1><2>...<17> / [ ]
<1> : チャンネル拡張ユニットID番号
0=本体
1=チャンネル拡張ユニット1
2=チャンネル拡張ユニット2
3=チャンネル拡張ユニット3
4=チャンネル拡張ユニット4
5=チャンネル拡張ユニット5
6=チャンネル拡張ユニット6
7=チャンネル拡張ユニット7
<2> : CH1の入力レンジコード
<3> : CH2の入力レンジコード
.
.
.
<17> : CH16の入力レンジコード
入力レンジコード
0=20V, 1=10V, 2=5V, 3=2V, 4=1V, 5=0.5V, 6=0.2V, 7=0.1V
関連コマンドRNG?
RPT :
コマンド形式
12-6
オートリピート設定
RPT : <1> / [ ]
<1>: 0=オートリピートストップ, 1=オートリピートスタート
関連コマンドRPT?
コマンド
内容
SCH :
コマンド形式
サーチ
SCH : <1><2>...<N> / [ ]
IDナンバーサーチ
<1> : 0
<2><3><4> : 001∼999または000
リアルタイムクロックサーチ
<1> : 1
<2><3>...<13> : YYMMDDhhmmss
アドレスサーチ
<1> : 2
<2><3>...<7> : hhmmss
スタートIDサーチ
<1> : 3
<2> : 0=順方向, 1=逆方向
BOD/EODサーチ
<1> : 4
<2> : 0=EOD, 1=BOD
ex) SCH : 0100
− ターゲット : ID=100
SCH : 1970506120000 − ターゲット:1997年5月6日12時00分00秒
関連コマンドSCH?
SLF :
コマンド形式
セルフチェック
SLF : <1> / [ ]
<1> : 0=セルフチェック中止, 1=セルフチェック開始
関連コマンドSLF?
SPD :
コマンド形式
テープ速度設定
SPD : <1>
<1> : 0=1× (標準速), 1=1/2×, 2=1/4×, 3=1/8×, 4=1/16×, F=EXT
関連コマンドSPD?
SPO :
コマンド形式
スピーカソース切換
SPO : <1> / [ ]
<1>: 0=ボイスチャンネル 1=モニタセレクトされたデータチャンネル
関連コマンドSPO?
TIM :
コマンド形式
リアルタイムクロック設定
TIM : <1><2>...<12>
<1><2>西暦 (下2桁)
<3><4><5><6>月日
<7><8><9><10><11><12>時分秒
関連コマンドTIM?
TRG :
コマンド形式
トリガモード設定
TRG : <1>
<1> : 0=RSV
1=プリトリガシングルモード (Low:開始) 2=プリトリガマルチモード (Low:開始, High:停止)
3=ノーマルシングルモード (Low:開始)
4=ノーマルマルチモード (Low:開始, High:停止)
関連コマンドTRG?
TRM :
コマンド形式
ターミネータ選択
TRM : <1>
<1> : 0=CR+LF, 1=CR, 2=LF
レコーダからの返信の区切りコードを指定する。デフォルトは (CR+LF)
関連コマンドTRM?
TSG :
コマンド形式
テスト信号選択
TSG : <1> / [ ]
<1> : テスト信号の選択
アナログチャンネル
0=
OFF
1=
AC
2=
+DC
3=
−DC
4=
GND
5=
EXT
関連コマンドTSG?
UTL :
コマンド形式
デジタルチャンネル
OFF
010000000000000001000..
110000000000000000111..
010000000100000001000..
000000000000000000000..
010101010101010101010..
ユーティリティモード設定
UTL : <1><2><3> / [ ]
<1> : 0=AT FMT OFF
<2> :
1=AT FMT ON
<4> : 0=BOT EJCT OFF <5> :
1=BOT EJCT ON
関連コマンドUTL?
0=ERA OFF
1=ERA ON
0=SKP ET03 OFF
1=SKP ET03 ON
<3> : 0=DEW OFF
1=DEW ON
<6> : 0=CMP MODE OFF
1=CMP MODE ON
12-7
ステータスコマンド
ステータスコマンドはレコーダからステータス情報を要求するコマンドです。レコー
ダはステータスコマンドを受信するとそれに対するステータス情報を送信します。
参考
/ [ ] パラメータはどれか1つのID番号を指定します。1台のレコーダのみの接続、ま
たは0番のレコーダに対してはこの指定を省略できます。同期運転している場合は、
マスター機がID=0, スレーブ機がID=1になります。
コマンド
12-8
内容
ADR? コマンド形式
返信形式
テープアドレス
ADR? / [ ]
ADR : <1><2><3><4><5><6><7><8><9><10>
テープアドレス
<1><2>: hh (時)
<3><4>: mm (分)
<5><6>: ss (秒)
テープ残量
<7><8>: hh (時)
<9><10>: mm (分)
ex) ADR? (現在のテープアドレスを要求)
ADR?/1 (ID=1のレコーダの現在のテープアドレスを要求)
ALM? コマンド形式
返信形式
アラームステータス
ALM? / [ ]
ALM : <1><2><3><4>
<1> : 0=正常, 1=電源電圧低下
<2> : 0=正常, 1=結露
<3> : 0=正常, 1=記録/再生エラー (バッファオーバー/アンダーフロー)
<4> : 0 (その他)
AUX? コマンド形式
返信形式
フロントパネルステータス
AUX? / [ ]
AUX : <1><2><3>
AUX1の状態
0=OFF
1=ON
AUX2の状態
0=OFF
1=ON
EXT.TCの状態
0=OFF
1=ON
ex) AUX:100 AUX1=ON
AUX:010 AUX2=ON
AUX:001 EXT TC=ON
BAR? コマンド形式
返信形式
バーメータ設定読み出し
BAR? / [ ]
BAR : <1><2>
<1>: 0=リアルタイムモード, 1=ピークホールドモード
<2>: 0=片振れモード, 1=両振れモード
関連コマンドBAR
BAT? コマンド形式
返信形式
バッテリステータス
BAT? / [ ]
BAT : <1><2><3><4>
<1> : 0=バッテリなし, 1=バッテリあり
<2> : 0=放電中でない, 1=放電中
<3> : 0=充電中でない, 1=充電中
<4> : 0=バッテリ残量なし
1=20%未満, 2=40%未満, 3=60%未満, 4=80%未満, 5=80%以上
CAL? コマンド形式
返信形式
キャリブレーションステータス
CAL? / [ ]
CAL : <1>
<1> : 0=キャリブレーション正常終了
1=キャリブレーション異常終了
2∼7 = 経過量
関連コマンドCAL
コマンド
CHA? コマンド形式
返信形式
CFG? コマンド形式
返信形式
内容
チャンネルモード設定読み出し
CHA?<1> / [ ]
<1>: 0=レコーダ設定データ, 1=テープデータ
CHA : <1><2>
<1> : アナログチャンネルコード
<2> : デジタルチャンネルコード
0=OFF
1=RSV
1=1ch (Async)
2=RSV
2=2ch (Async)
3=RSV
3=4ch (Async)
4=RSV
4=8ch (Async)
5=16ch (SIR-1000/1000i)
5=RSV
6=32ch (SIR-1000/1000i)
6=SVB-10
7=64ch (SIR-1000/1000i)
7=RSV
8=128ch (SIR-1000/1000i)
8=RSV
9=RSV
9=RSV
A=RSV
A=1ch (Sync)
B=2ch (SIR-1000W)
B=2ch (Sync)
C=4ch (SIR-1000W)
C=4ch (Sync)
D=8ch (SIR-1000W)
D=8ch (Sync)
E=16ch (SIR-1000W)
E=RSV
F=RSV
F=RSV
関連コマンドCHA
レコーダ構成
CFG? / [ ]
CFG : <1><2><3><4><5><6><7><8><9><10>
<1> : 0=SIR-1000, 1=SIR-1000W, 2=SIR-1000i
<2> : オプションスロット1の種類
0=なし
1=RSV
2=STB-10
3=STB-30
4=RSV
5=RSV
<3> : オプションスロット2の種類
0=なし
1=チャンネル拡張用ボード
2=RSV
3=RSV
4=SSB-10A
5=SSB-10S
6=SVB-10
<4> : チャンネル拡張ユニット ID=1
0=なし
1=SCX-32/16W
2=SCX-32i
SIR-1000/1000i
SIR-1000W
<5> : チャンネル拡張ユニット ID=2
<5> : RSV
0=なし
<6> : RSV
1=SCX-32
.
.
.
.
2=SCX-32i
.
.
<10> : チャンネル拡張ユニット ID=7
<10> : RSV
0 = なし
1 = SCX-32
2= SCX-32i
ex) CFG?
CFG : 2011220000
(SIR-1000iのオプションスロット2にチャンネル拡張用ボードがあり、
ID=1にSCX-32が、ID=2, 3にSCX-32iがそれぞれ接続されている)
12-9
コマンド
内容
CMD? コマンド形式
返信形式
コマンドチェック
CMD?
CMD : <1>
<1> : 0=直前のコマンドにエラーなし, 1=直前のコマンドにエラーあり
関連コマンドCMD
ERR? コマンド形式
返信形式
エラーチェック
ERR?
ERR : <1><2><3><4><5>
<1> : 電源系
0 = エラーなし, 1 = エラーあり
<2> : DSP系
0 = エラーなし, 1 = エラーあり
<3> : アナログ系
0 = エラーなし, 1 = エラーあり
<4> : ドライブ系
0 = エラーなし, 1 = エラーあり
<5> : 周辺機器
0 = エラーなし, 1 = エラーあり
関連コマンドCAL, SLF
FMT? コマンド形式
返信形式
テープフォーマット実行ステータス
FMT? / [ ]
FMT : <1><2><3><4>
<1> : 0=下記以外 (電源投入後、STOPコマンド後など)
1=テープフォーマット中
2=テープフォーマット正常終了(FMT?後0になる)
3=テープフォーマット異常終了(FMT?後0になる)
<2><3><4> : IDナンバー (001∼999)
関連コマンドFMT
IDS? コマンド形式
返信形式
テープIDナンバー読み出し
IDS? / [ ]
IDS : <1><2><3>
<1><2><3> : IDナンバー (000∼999)
関連コマンドIDS
INP? (SIR-1000/1000iのみ)
コマンド形式
返信形式
入力形式設定読み出し
INP? <1><2> / [ ]
INP : <1><2>...<18>
<1> : 0=レコーダ設定, 1=テープデータ
<2> : チャンネル拡張ユニットID番号
0 : 本体
1=チャンネル拡張ユニット1
2=チャンネル拡張ユニット2
3=チャンネル拡張ユニット3
4=チャンネル拡張ユニット4
5=チャンネル拡張ユニット5
6=チャンネル拡張ユニット6
7=チャンネル拡張ユニット7
<3> : CH1の入力形式
0=DIRECT
1=SENSOR
<4> : CH2の入力形式
.
.
.
<18> : CH16の入力形式
関連コマンドINP
LCH? (SIR-1000Wのみ)
コマンド形式
返信形式
12-10
LSBデジタルチャンネル読み出し
LCH? : <1> / [ ]
<1>: 0=レコーダ設定データ, 1=テープデータ
LCH : <1>
<1> : 0=OFF
1=1 ch
2=2 ch
3=4 ch
コマンド
LVA? コマンド形式
返信形式
内容
信号レベル読み出し (テキストフォーマット)
LVA?<1> / [ ]
<1> : チャンネル拡張ユニットID番号 (0=本体)
LVA : <1><2>...<32> 片振れモードのとき (BARコマンド関連)
<1><2> : CH1データ (16進2桁)
.
.
.
返信形式
<31><32> : CH16データ (16進2桁)
7 F=MAXかつオーバーロード (OVR)
0 0=MIN
LVA : <1><2>...<64> 両振れモードのとき (BARコマンド関連)
<1><2> : CH1 +MAXデータ (16進2桁)
<3><4> : CH1 −MAXデータ (16進2桁)
.
.
.
<61><62> : CH16 +MAXデータ (16進2桁)
<63><64> : CH16 −MAXデータ (16進2桁)
7 F=+MAXでかつオーバーロード (OVR)
82=−MAXでかつオーバーロード (OVR)
LVB? コマンド形式
返信形式
信号レベル読み出し (バイナリフォーマット)
LVB?<1> / [ ]
<1> : チャンネル拡張ユニットID番号 (0=本体)
LVB : <1><2>...<16> 片振れモードのとき (BARコマンド関連)
<1> : CH1データ (バイナリ)
.
.
.
返信形式
<16> : CH16データ (バイナリ) 7F=MAXでかつオーバーロード (OVR)
00=MIN
LVB : <1><2>...<32> 両振れモードのとき (BARコマンド関連)
<1>: CH1 +MAXデータ
<2>: CH1 −MAXデータ
.
.
.
<31>: CH16 +MAXデータ
<32>: CH16 −MAXデータ
7F=+MAXでかつオーバーロード (OVR)
82=−MAXでかつオーバーロード (OVR)
MAP? コマンド形式
返信形式
スレーブID読み出し
MAP?
MAP : <1><2>...<14><15>
<1> : ID1
<8> : ID8
<2> : ID2
<9> : ID9
.
.
.
<6> : ID6
<7> : ID7
MEM? コマンド形式
返信形式
MOD? コマンド形式
返信形式
.
.
.
<14> : ID14
<15> : ID15
メモ文字列読み出し
MEM?<1> / [ ]
<1> : 0=レコーダ設定データ, 1=テープデータ
MEM : <1><2>...<96>
<1> <2>...<96> : 最大96文字までのテキストキャラクタ
関連コマンドMEM
テープ走行モード読み出し
MOD? / [ ]
MOD : <1><2>
<1> : 0=STOP, 1=FWD, 2=E-E, 3=REC, 4=FWD-PAUSE, 5=REC-PAUSE, 6=FF, 7=RSV,
8=REW, 9=RSV, A=EJECT
<2> : S=STOP遷移中
P=PAUSE遷移中
0=遷移終了
F=FWD遷移中 (同期モードのみ)
関連コマンドMOD
12-11
コマンド
内容
MON? コマンド形式
返信形式
モニタチャンネル設定読み出し
MON? / [ ]
MON : <1><2>
<1> : 拡張ユニット番号
<2> : チャンネルコード
0=本体
0=チャンネル1
1=拡張ユニットID 1 (SIR-1000/1000i)
1=チャンネル2
2=拡張ユニットID 2 (SIR-1000/1000i)
2=チャンネル3
3=拡張ユニットID 3 (SIR-1000/1000i)
3=チャンネル4
4=拡張ユニットID 4 (SIR-1000/1000i)
4=チャンネル5
5=拡張ユニットID 5 (SIR-1000/1000i)
5=チャンネル6
6=拡張ユニットID 6 (SIR-1000/1000i)
6=チャンネル7
7=拡張ユニットID 7 (SIR-1000/1000i)
7=チャンネル8
8=チャンネル9
9=チャンネル10
A=チャンネル11
B=チャンネル12
C=チャンネル13
D=チャンネル14
E=チャンネル15
F=チャンネル16
関連コマンドMON
OFA? コマンド形式
オートオフセット設定ステータス
OFA?<1> / [ ]
<1> : チャンネル拡張ユニットID番号 (0=本体)
OFA : <1>
<1> : 0=オートオフセット設定終了, 1=オートオフセット設定中
関連コマンドOFA
返信形式
OFS? コマンド形式
返信形式
DCオフセット値読み出し
OFS?<1><2> / [ ]
<1> : 0=レコーダ設定値, 1=テープデータ
<2> : チャンネル拡張ユニットID番号 (0=本体)
OFS: <1><2>...<32>
<1><2> : CH1のDCオフセット (2の補数表示の2桁16進)
<3><4> : CH2のDCオフセット (2の補数表示の2桁16進)
.
.
.
<31> <32> : CH16のDCオフセット (2の補数表示の2桁16進)
関連コマンドOFS
OPL? コマンド形式
返信形式
出力レベル設定読み出し
OPL?<1><2> / [ ]
<1> : 0=レコーダ設定値, 1=RSV
<2> : チャンネル拡張ユニットID番号 (0=本体)
OPL : <1><2>...<16>
<1> : CH1の出力レベルコード
<2> : CH2の出力レベルコード
.
.
.
<16> : CH16の出力レベルコード
出力レベルコード
0=RSV, 1=RSV, 2=5V, 3=2V, 4=1V, 5=RSV, 6=RSV, 7=RSV, 8=RSV, 9=RSV, A=マニュアル
関連コマンドOPL
12-12
PNL? コマンド形式
返信形式
パネルロックステータス読み出し
PNL? / [ ]
PNL : <1>
<1> : 0=パネルロック解除, 1=パネルロック中
関連コマンドPNL
PSV? コマンド形式
返信形式
パワーセーブステータス
PSV? / [ ]
PSV : <1>
<1> : 0=パワーセーブ解除, 1=パワーセーブ
関連コマンドPSV
コマンド
RNA? コマンド形式
返信形式
RNG? コマンド形式
返信形式
内容
オートレンジ設定ステータス読み出し
RNA? <1> / [ ]
<1> : RSV (常に0)
RNA :<1>
<1> : 0=オートレンジ設定終了, 1=オートレンジ設定中
関連コマンドRNA
入力レンジ設定値の読み出し
RNG?<1><2> / [ ]
<1> : 0=レコーダ設定値, 1=テープデータ
<2> : チャンネル拡張ユニットID番号
0=本体
1=チャンネル拡張ユニット1
2=チャンネル拡張ユニット2
3=チャンネル拡張ユニット3
4=チャンネル拡張ユニット4
5=チャンネル拡張ユニット5
6=チャンネル拡張ユニット6
7=チャンネル拡張ユニット7
RNG : <1><2>...<16>
<1> : CH1の入力レンジコード
<2> : CH2の入力レンジコード
.
.
.
<16> : CH16の入力レンジコード
入力レンジコード
0=20V, 1=10V, 2=5V, 3=2V, 4=1V, 5=0.5V, 6=0.2V, 7=0.1V
関連コマンドRNG
RPT? コマンド形式
返信形式
オートリピートステータス読み出し
RPT? / [ ]
RPT : <1>
<1> : 0=下記以外
1=オートリピート - 記録
2=オートリピート - 巻戻し
関連コマンドRPT
SCH? コマンド形式
返信形式
サーチステータス
SCH? / [ ]
SCH : <1>
<1> : 0=下記以外 (電源投入後、STOP後)
1=サーチ中
2=サーチ終了(FOUND)
3=サーチ終了(NOT FOUND)
関連コマンドSCH
SLF? コマンド形式
返信形式
セルフチェックステータス
SLF? / [ ]
SLF : <1>
<1> : 0=下記以外 (電源投入後、STOP後)
1=セルフチェック中
2=セルフチェック終了(OK)
3=セルフチェック終了(NG)
関連コマンドSLF
関連コマンドERR?
SPD? コマンド形式
テープ速度読み出し
SPD?<1> / [ ]
<1> : 0=レコーダ設定値, 1=テープデータ
SPD : <1>
<1> : 0=1×, 1=1/2×, 2=1/4×, 3=1/8×, 4=1/16×, F=EXT
関連コマンドSPD
返信形式
SPO? コマンド形式
返信形式
スピーカソース切換ステータス
SPO? / [ ]
SPO : <1>
<1> : 0=ボイスチャンネル, 1=モニタに選択されたデータチャンネル
関連コマンドSPO
12-13
コマンド
STA? コマンド形式
返信形式
ステータスA
STA? / [ ]
STA : <1><2><3><4><5><6><7>
<1> : テープローディング状態
0=テープがローディングされていない
1=ローディング中
2=ローディング終了 (テープがローディングされている状態)
3=エジェクト中
<2> : テープポジション
0=下記以外
1=BOD
2=EOD
3=EOT
<3> : TOC
0=TOCがFLASH MEMORYにない
1=TOCがFLASH MEMORYにある
<4> : MIC
0=MICなし
1=MIC付き
<5> : 記録プロテクト
0=プロテクトOFF
1=プロテクトON
<6> : TAPE TYPE
0=25G
<7> : TAPE FORMAT
0=標準
TIM? コマンド形式
リアルタイムクロック読み出し
TIM?<1> / [ ]
<1> : 0=レコーダ設定データ, 1=テープデータ
TIM : <1><2>...<12>
<1><2>西暦 (下2桁)
<3><4><5><6>月日
<7> <8><9><10><11><12>時分秒
関連コマンドTIM
返信形式
TOC? コマンド形式
返信形式
12-14
内容
TOCデータ読み出し
TOC?<1><2><3> / [ ]
<1><2><3>: ID番号
TOC : <1><2>...<25>
<1> : スタートID
0=スタートIDでない 1=スタートIDである
<2> : 記録モード
0=16chアナログモード (スタンダード)
1=フルアナログモード
2=フルデジタルモード (SBS-10A/S使用時)
3=アナログ+デジタルモード
<3> : CHコード
記録モード<2>=0, 1, 3 の場合はアナログCHモードを示す
1=2ch, 2=4ch, 3=8ch, 4=16ch, 5=32ch, 6=64ch, 7=128ch
記録モード<2>=2 の場合はデジタルCHモードを示す
1=1ch, 2=2ch, 3=4ch, 4=8ch
<4> : 記録速度
0=1×(標準速), 1=1/2×, 2=1/4×, 3=1/8×, 4=1/16×,
A=2×, B=4×, C=8×, F=EXT
<5> : 予約
常に0
<6>-<17> : 記録開始時刻
<6><7> : 西暦 (2桁)
<8><9><10><11> : 月日
<12><13><14><15><16><17> : 時分秒
<18> : プリトリガ記録の有無
0=プリトリガ記録でない 1=プリトリガ記録である
<19> : 記録時エラーの有無
0=記録時エラーなし
1=記録時エラーあり
<20><21><22><23><24><25> : 記録時間長
hhmmss
関連コマンドVOL?
コマンド
TRG? コマンド形式
返信形式
内容
トリガモード設定ステータス
TRG? / [ ]
TRG : <1>
<1> : 0=トリガ無効
1=プリトリガシングルモード (Low:開始)
3=ノーマルシングルモード (Low:開始)
関連コマンドTRG
2=プリトリガマルチモード (Low:開始, High:停止)
4=ノーマルマルチモード (Low:開始, High:停止)
TRM? コマンド形式
返信形式
ターミネータの選択ステータス(返信ストリングス)
TRM? / [ ]
TRM : <1>
<1> : 0=CR+LF, 1=CR, 2=LF
関連コマンドTRM
TSG? コマンド形式
返信形式
テスト信号の選択ステータス
TSG? / [ ]
TSG : <1>
<1> : テスト信号の選択
アナログチャンネル
0=
OFF
1=
AC
2=
+DC
3=
−DC
4=
GND
5=
EXT
関連コマンドTSG
デジタルチャンネル
OFF
010000000000000001000..
110000000000000000111..
010000000100000001000..
000000000000000000000..
010101010101010101010..
UTL? コマンド形式
返信形式
ユーティリティモード設定読み出し
UTL? / [ ]
UTL : <1><2><3><4><5><6>
<1> : 0=AT FMT OFF
<4> : 0=BOT EJCT OFF
1=AT FMT ON
1=BOT EJCT ON
<2> : 0=ERA OFF
<5> : 0=SKP ET03 OFF
1=ERA ON
1=SKP ET03 ON
<3> : 0=DEW OFF
<6> : 0=CMP MODE OFF
1=DEW ON
1=CMP MODE ON
関連コマンドUTL
VOL? コマンド形式
返信形式
テープボリウムの読み出し
VOL? / [ ]
VOL : <1><2>...<32>
<1> : フォーマット
0=標準
<2> : SIRタイプ
0=SIR-1000
1=SIR-1000W
2=SIR-1000i
<3><4><5><6> : 合計ID数(MAX1000)
<7><8><9> : MIC内合計ID数(MAX100)
<10><11><12><13><14> : TOC記録位置 (レコード番号)
<15><16><17><18><19><20> : 最後に記録したSIRシリアル番号
<21><22> : 最後に記録した年 (西暦下2桁)
<23><24><25><26> : 最後に記録した月日
<27><28><29><30><31><32> : 最後に記録した時分秒
関連コマンドTOC?
12-15
13 ガードフレームの取扱方法
本機は、ガードフレームSHL-10 (別売) を装着することによって、車載時の車体への
固定や、運搬時の本体の保護が便利に行なえます。
ご使用の前に
ガードフレームの固定は、レコーダ本体の前後左右の六角穴付ボルト8 本によって
行ないます。
これらのボルトはレコーダ本体左右の側面パネルの固定を兼ねていますので、ガードフ
レームの取付/取外しは全部同時でなく、前後左右1ヶ所ずつ順次行なってください。
内容物
• ガードフレーム : 4枚 (同一形状)
• Lレンチ
: 六角穴付ボルト用 (4 mm)
レコーダへの取付方法
1
レコーダ本体の右側面手前の六角穴付ボルト4×10 (2本) を取り外してくださ
い。
2
ガードフレームの保護シートの側をレコーダ本体に当ててください。
3
ガードフレームに付属の六角穴付ボルト4×16 (2本) でガードフレームを固定し
てください。
参考
六角穴付ボルトは2 本とも仮止めした後、締め付けてください。
4
残り3ヶ所についても順次同様に行なってください。
ガードフレーム
六角穴付ボルト
4×16
13-1
14 バッテリパックの取扱方法
本機は、バッテリパックBP-L60/L60A (別売) またはBP-L90/L90A (同) を装着するこ
とによって、ACまたはDC電源の得られない場所でも使用できます。
拡張ユニットやオプションボードを使用する場合は、BP-L90/L90Aをご使用くださ
い。
ご使用の前に
本品はリチウムイオンタイプの充電式電池です。
使用の前に必ず充電してください。
専用バッテリチャージャBC-L100 (別売) で充電するときは、その取扱説明書を参照
してください。
寿命について
十分に充電したにもかかわらず使用できる時間が短くなってきたときは電池の寿命
がきていますので、新品のバッテリパックと交換してください。
使用しないときは
• レコーダ本体から取り外し、乾燥した涼しいところで保管してください。
• 長期間使用しないときは、放電させてから保管してください。
! 警告
• 所定の充電器以外は使用しないでください。
• 火気に近づけたり、火中に投じたりしないでください。
• ショート (+と−の端子を針金などの金属で接続すること) させないでください。
• 水にぬらさないでください。
• 強い衝撃を与えたり、落としたりしないでください。
• 変形・改造・分解などはしないでください。
• 電池から漏れた液が目に入ったときは、きれいな水で洗った後、すぐに医師の治
療を受けてください。
! 注意
• 外装を剥がしたり、傷を付けたりしないでください。
• 機種・容量・銘柄の違う電池と接続しないでください。
• 所定の時間を超えて充電しないでください。
• 電池が変形・液洩れ・変色したり、異常なときは使用しないでください。
• 電池から漏れた液が皮膚や衣類に付着したときは、きれいな水で洗い流してくだ
さい。
お願い
使用済みとなった電池は、端子に絶縁テープを貼るなどの処置をしてから、リ
サイクル協力店または当社セールスにお渡しください。
14-1
レコーダ本体による充電方法
1
バッテリパックBP-L60/L60A (別売) またはBP-L90/L90A (同) をレコーダ本体左
側面のバッテリパック装着部に装着します。
2
所定のAC電源をレコーダ本体に供給します。背面パネルのSTAND BYスイッチ
にかかわらず充電できます。
参考
• レコーダ本体にバッテリパックを装着すると充電を開始し、BATT LEDが点滅
して冷却ファンが回転します。充電が完了するとBATT LEDが消灯します。充
電時間は周囲温度25℃のとき、BP-L60/L60Aで約8時間、BP-L90/L90Aで約12
時間です。
• レコーダ本体の他の機能を使用しないときは、STAND BYスイッチをOFFのま
まにしておけば、充電完了とともにレコーダ本体の電源が自動的に切れるので
便利です。
• チャンネル拡張ユニットが接続されているときの充電時間は、レコーダ本体の
ときの約10倍かかります。
14-2
3
充電が完了すると、BATT LEDが消灯します。
4
バッテリパックをレコーダ本体から取り外してください。
15 リモートコントロールユニットの取扱方法
本機は、リモートコントロールユニットSRM-10 (別売) を接続することによって、
離れたところから操作できます。
機能
指令機能
SRM-10は、レコーダ本体に対して以下の指令を出すことができます。
• テープ走行モード設定
• 入力レンジ設定 (チャンネル毎および全チャンネル一括)
• 入力DCオフセット設定 (チャンネル毎および全チャンネル一括)
• IDインクリメント
• モニタチャンネル設定
• サーチ (IDサーチ、EODサーチ)
確認機能
SRM-10は、レコーダ本体の以下の状態を表示することができます。
• ローディング状態
• テープ走行モード
• チャンネルモード
• テープ速度
• チャンネル毎信号レベル (バーメータ)
• オーバーレンジ
• 入力レンジ
• 入力DCオフセット
• IDナンバー
• モニタチャンネル
• テスト信号種類
• IRIG-Bタイムコード信号
• テープ位置情報
• 警告表示
• エラーコード
15-1
インターフェース
信号フォーマット : EIA RS-232C準拠
コネクタ型式
: 丸形、12-pin
伝送レート
: 9600 bps、同期
コネクタピンアサイン
ピン番号 信号名
機能
機能
ピン番号
信号名
電源
7
RSV
IRIG-B入力
8
RXD
RS-232C 入力
RS-232C 出力
1
+6V
2
EXT TC
3
SG
RS-232C 信号グランド
9
TXD
4
SG
RS-232C 信号グランド
10
FG
5
RSV
11
RSV
6
RSV
12
RSV
RS-232C シールド
接続
SRM-10の丸形コネクタを、レコーダ本体背面パネルのREMOTEコネクタに接続して
ください。
! SELECTOR
!
220V
9
8
25
6
7
24
21
22
23
19
20
18
17
16
15
14
1
5
4
3
2
13
12
COM
11
10
9
8
7
6
5
4
AUX-2 (IRIG-B)
IN
OUT
VOLTAGE
AC FUSE
T4A
8 7 6 5 4 3 2 1
3
2
1
EXT. CONT
REMOTE
SYNC
AUX-1 (DIGITAL)
IN
OUT
TRIG/REC
IN
% / dB
MST / SLV
IRIG ON / OFF
APD OFF / ON
(UP / DOWN)
RAL / HLD
9.6 / 19.2
TRG S/M
PTRG OFF/ON
240V
DC IN
STAND BY
AC IN
DC BREAKER
XLR 32F
CANNON
OPTION SLOT 1
OPTION SLOT 2
D4
D3
D2
D1
LSB DIGITAL
OUTPUT
ANALOG
8
7
6
5
4
3
2
1 OUTPUT
リモートコントロールユニットSRM-10
LOADING
REMOTEへ
dB
%
OVR 1 1/2 1/4 1/8 1/16 1 2
SPD
AUX
EXT TC
EXP SYN
ID
BOD
EOD
CAUTION
ID
OVR
RANGE
OFFSET
PNL LOK
+2
+100
0
–6
MONI
-40 -100
OVR
CH
RANGE
SPEED
CH
V X1/
S- TIME
ADDRESS REMAIN T - T I M E
Y
M
D
H
M
S
0
-20
1-4 5-8
9-12 13-16
PK-CLR
REW
FWD
ALL CH SELECT
FF
PAUSE
STOP
REC
LOAD
REMOTE CONTROL UNIT SRM-10
15-2
操作方法
SRM-10の各キー・各ディスプレイは、下記のものを除き、レコーダ本体の同じ名称
のものと同一の働きをします。
PNL LOKキー
このキーを押すとパネルロックモードとなり、キー左上のLEDが点灯します。レ
コーダ本体正面パネル上の全てのキーが無効となります。
パネルロックモードを解除するときはこのキーを押します。キー左上のLEDが消灯
します。
PNL LOKキー
LOADING
dB
%
OVR 1 1/2 1/4 1/8 1/16 1 2
SPD
AUX
EXT TC
EXP SYN
ID
BOD
EOD
CAUTION
ID
OVR
RANGE
OFFSET
PNL LOK
+2
+100
0
–6
MONI
SPEED
CH
V X1/
S- TIME
ADDRESS REMAIN T - T I M E
Y
M
D
H
M
S
0
-20
-40 -100
OVR
CH
RANGE
1-4 5-8
9-12 13-16
PK-CLR
REW
FWD
ALL CH SELECT
FF
PAUSE
STOP
REC
LOAD
REMOTE CONTROL UNIT SRM-10
上記以外はレコーダ本体の各項目を参照してください。
項目
ページ
No.
項目
ページ
No.
LOADING LED
3-3
5
AUX LED
3-15
#£
PAUSEキー
3-5
7
EXP LED
3-15
#¢
RECキー
3-5
8
SYN LED
3-15
#∞
STOPキー
3-5
9
EXT TC LED
3-15
#§
FWDキー
3-5
0
バーメータエリア
3-16
#¶
FFキー
3-5
!¡
ID表示エリア
3-17
#•
EOD LED
3-6
!™
CAUTION表示エリア
3-17
#ª
REWキー
3-6
!£
MONI表示エリア
3-17
$º
BOD LED
3-6
!¢
RANGE表示エリア
3-17
$¡
RANGEキー
3-9
!¶
SPEED表示エリア
3-17
$™
OFFSETキー
3-9
!•
テープ位置表示エリア
3-18
$£
ID/UTLキー
3-11
@™
PK-CLRキー
3-19
$¢
:キー
3-13
@¢
ALL CHキー
3-19
$∞
8キー
3-13
@∞
SELECTキー
3-19
$§
OVR LED
3-15
#¡
LOADキー
3-20
$¶
SPD LED
3-15
#™
参考
:キー, 8キーで数値または桁を終端まで送ったのち、もう一度キーを押すと始端に
ジャンプします。
15-3
16 チャンネル拡張ユニットの取扱方法
SIR-1000Wは、チャンネル拡張ユニットSCX-16W (別売) を使用することによって、
同時に最大16チャンネルのアナログデータ信号の記録/再生が行なえます。
チャンネル数および周波数帯域の関係は下記のとおりです。
チャンネル数
16
SCX-16W (台)
1
1 (標準速)
DC∼40 kHz
1/2
DC∼20 kHz
1/4
DC∼10 kHz
1/8
DC∼5 kHz
1/16
DC∼2.5 kHz
テ
ー
プ
速
度
16-1 ご使用の前に
• SIR-1000WとSCX-16Wとの接続は、必ず電源OFFの状態で行なってください。
• SIR-1000WがAC, DC (15 V以上) またはバッテリー (BP-L90/L90A) により駆動されてい
るときは、SIR-1000WよりSCX-16Wに電源が供給されます。
! 警告
風の吹き出し口を塞がないようにしてください。
! 注意
• 強い静電ノイズを受けると、正しく動作しない場合がありますので、SIR-1000Wと
SCX-16Wのアース端子間を接続して使用してください。
• SCX-16Wを外して使うときは、拡張ケーブルをSIR-1000Wから外してください。
もし接続したままにすると、データにノイズが混入することがあります。
16-1
16-2 各部の名称と働き
正面パネル
1
4
CHANNEL EXPANSION UNIT
POWER
dB
2
SCX- 1 6 W
%
BAND
0VR
40k
0 100
20k
-6
50
- 20
10
10k
5k
ANALOG
INPUT
≤ ± 2 6 . 6 v p k 1 0 0k
9
10
11
12
13
14
15
16
2.5k
3
REF
1 POWER LED
SCX-16WがPOWER ONのときに点灯します。
電源電圧が規定値より低下すると点滅します。
POWER ON/OFFはSIR-1000WのSTAND BYスイッチで行ないます。SIR-1000W
に接続されていない場合は電源が入りません。
2 バーメータ
CH 9∼CH 16のアナログデータ信号のレベルを片振れ式のLED列で表示します。
dBスケール (−20 dB, −6 dB, 0 dB, OVR)と% スケール (10%, 50%, 100%, OVR)
があります。OVR LEDはオーバーレンジのときに点灯します。
参考
SCX-16Wのバーメータは片振れ式のため、 % スケールでも信号の極性にかかわ
らず同一方向に振れ、SIR-1000Wと異なっています。
SIR-1000WのバーメータはSCX-16Wの信号レベルもモニタ表示しています。
16-2
3 ANALOG INPUTコネクタ
CH 9∼CH 16のアナログデータ信号をここに入力します。
! 注意
• 必ず指定範囲内 (±26.6 Vpk) の信号を入力してください。
• 入力電圧が100 Vpkを超えると内部回路が破損することがあります。
参考
TSGモードでテスト信号にEXTが選択されているときは、SCX-16WのCH 9への
入力信号がそのユニットの全チャンネルに対するテスト信号となります。
4 BAND LED
SIR-1000Wで設定されているチャンネルモードおよびテープ速度に対応した周
波数帯域を表示するLED (40k, 20k, 10k, 5k, 2.5k) が点灯します。
16-3
背面パネル
3
1
2
XLR 32F
EXPANSION IN
DC IN
BREAKER
CANNON
4
16
15
14
13
12
11
10
9
ANALOG
OUTPUT
5
6
1 DC INコネクタ
外部DC電源 (定格12 V, 許容範囲11∼30V)をここに供給します。
! 注意
• DC電源コード (付属品) の極性は赤:+、黒:−です。
• コネクタのピンアサインはPin 1:+、Pin 2:−、Pin 3:フレームGNDです。
• SIR-1000Wに15 V以上の安定した外部DC電源が供給されているときに限り、
SCX-16WにSIR-1000WからDC電圧が供給されます。
• 15 V以上の安定した外部DC電源が供給できない場合は、SIR-1000WとSCX16Wそれぞれに規定の外部DC電圧 (DC11∼30 V) を供給してください。
2 DCサーキットブレーカ
DC電源用ブレーカです。
3 EXPANSION INコネクタ
SIR-1000Wとの間を拡張ケーブルで接続するコネクタです。
4 アース端子
接地端子です。信号ラインのアース側および筐体と同電位になっています。
5 出力レベル調整ボリウム
CH 9からCH 16までのアナログデータ信号の出力レベルを調整するときに使い
ます。
SIR-1000WのOUT/TSGキーでマニュアルポジションに設定されているときに有
効です。
6 ANALOG OUTPUTコネクタ
CH 9からCH 16までのアナログデータ信号を出力するときに使います。
BNCケーブル (別売) をそれぞれに接続してください。
16-4
左側面パネル
1
1 通風孔
SCX-16W内部を冷却するための空気の取り入れ口です。
! 注意
• SCX-16W内部の過熱を防ぐため、通風孔をふさがないようにしてください。
• SCX-16W左側面に熱のある物体を置かないでください。
• SCX-16W左側面と他の物体の間隔は50mm以上離してください。
右側面パネル
1
SCX-16W
11-30V
*.*A/12V
Sony Precision Technology Inc.
SER.
MADE IN JAPAN
*-***-***-**
1 冷却ファン
SCX-16W内部を冷却するファンです。
! 注意
風の吹き出し口を塞がないようにしてください。
16-5
16-3 本体との接続
1
SIR-1000Wの電源をOFFしてください。
2
SIR-1000W背面のOPTION SLOT 2のカバーを左右の+K3×20ネジをゆるめて取
り外し、そのあとに付属の接続基板を装着し、左右を+K3×20ネジで固定して
ください。
3
拡張ケーブル (SCX-16Wに付属) を用いて、SIR-1000W背面に装着された接続基
板のEXPANTION OUTコネクタとSCX-16WのEXPANTION INコネクタとを接続
してください。
4
SIR-1000Wの電源をONしてください。
5
付属のコンバインフレーム (前後左右 計4個) を用いると、SIR-1000Wと一体化
でき、持ち運びや基台への固定が便利になります。
! 注意
• SIR-1000Wを15 V未満の外部DC電源で使う場合は、SCX-16Wにも同一の外部
DC電源から直接電力を供給してください。なお、SIR-1000WをAC、バッテリ
または15 V以上の外部DC電源で使う場合は、SIR-1000WからSCX-16Wに電源
が供給されます。
• 延長拡張ケーブル (SDK-10 : 別売) は使用できません。
コンバインフレームの使用方法
使用の前に
コンバインフレームの固定は、SIR-1000WおよびSCX-16Wの前後左右の六角穴付ボ
ルト4×16計12 本によって行ないます。
これらのボルトはSIR-1000WおよびSCX-16W左右のサイドフレームの固定を兼ねて
いますので、コンバインフレームの取付/取外しは全部同時でなく、前後左右1ヶ所
ずつ順次行なってください。
使用物品
• コンバインフレーム
: 4枚 (同一形状)
• 六角穴付ボルト4×16
: 12本
• Lレンチ (六角穴付ボルト用) : 1本
16-6
取付方法
1
4 mmの+ドライバを用意してください。
2
SIR-1000Wを裏返し、ドライバで前後の脚のネジ+PS3×6計4本を外し、前後の
脚をSIR-1000Wから外してください。
BKW-L601
+PS3×6
3
SCX-16Wの上にSIR-1000Wを重ねてください。
4
SIR-1000Wの右側面手前の六角穴付ボルト4×12 (2本) を取り外してください。
5
SCX-16Wの右側面手前の六角穴付ボルト4×12 (1本) を取り外してください。
6
コンバインフレームの保護シート面の側をSIR-1000WおよびSCX-16Wに当てて
ください。
7
付属の六角穴付ボルト4×16 (3本)でコンバインフレームをSIR-1000Wおよび
SCX-16Wに固定してください。
参考
六角穴付ボルトは3本とも仮止めした後、締め付けてください。
8
残り3ヶ所についても順次同様に行なってください。
SIR-1000W
コンバインフレーム
SCX-16W
16-7
16-4 操作方法
データ信号系の接続
1
BNCケーブル (別売) を用いて、各チャンネルのINPUTコネクタに信号源を、ま
た各チャンネルのOUTPUTコネクタに測定器を接続してください。
記録 (アナログモード)
1
入力レンジ・入力DCオフセット・出力レベルの調整は、8キー・9キーでユ
ニットを選択後、SIR-1000W本体で設定してください。
2
データ記録の操作はSIR-1000W単体の場合と同様に行なってください。
1
SIR-1000Wで記録済みテープを再生すると、記録時のチャンネルモードと同一
再生 (アナログモード)
に自動的に設定され、SCX-16WのOUTPUTコネクタおよびSIR-1000WのMONI
コネクタにデータ信号が出力されます。
2
データ再生の操作はSIR-1000W単体の場合と同様に行なってください。
キャリブレーション
SIR-1000Wのキャリブレーション操作によって、SCX-16Wのキャリブレーションが
実行されます。
16-8
17 同期モードの取扱方法
本機は、本体2台をシンクケーブルSCK-10 (別売) で接続し、同期モードとすること
によって同期記録および同期再生が行なえます。
これにより、アナログデータ信号の周波数帯域を変えることなくチャンネル数を2倍
(最大256チャンネル) にしたり、マスター機とスレーブ機とでチャンネルモードを変
えて異なる周波数帯域の信号を同時に記録/再生したり、入力データモードを変えて
アナログとデジタルの異なるフォーマットの信号を同時に記録/再生したりすること
ができます。
17-1 ご使用の前に
• シンクケーブルの接続は、必ず双方のレコーダ本体がPOWER OFFの状態で行なっ
てください。
• 電源はそれぞれ別になっています。双方のレコーダ本体およびチャンネル拡張ユ
ニットに所定の電源を供給してください。
• 必ず一方のレコーダをマスター機、他方をスレーブ機に設定してください。
設定は背面のデジタルスイッチによって行ないます。
• シンクケーブルで接続されない場合は、背面のデジタルスイッチの設定にかかわ
らず、マスター機として作動します。
• セルフチェックおよびキャリブレーションはマスター機、スレーブ機別々に行なっ
てください。
• 同期モードでIRIG-Bタイムコード信号を記録するときは、マスター機のみに信号
を入力してください。スレーブ機には入力しないでください。
• レコーダがシンクケーブルで接続されている場合は、必ずマスター機とスレーブ
機に電源を供給してください。
17-1
17-2 接続と設定
8 7 6 5 4 3 2 1
8 7 6 5 4 3 2 1
MST / SLV
MST / SLV
マスター機
スレーブ機
8
25
6
7
13
24
12
21
22
23
11
10
9
19
20
8
7
18
6
17
5
16
4
15
3
14
2
1
REMOTE
9
8
25
6
7
24
21
22
23
19
20
18
17
16
15
14
1
5
4
3
2
13
12
11
10
9
8
7
6
5
4
3
2
1
S
COM
AUX-2 (IRIG-B)
IN
OUT
VOLTAGE
AC FUSE
T4A
! SELECTOR
!
1
2
EXT. CONT
STAND BY
AC IN
DC BREAKER
3
240V
DC IN
XLR 32F
4
TRIG/REC
IN
8 7 6 5 4 3 2 1
220V
RAL / HLD
9.6 / 19.2
TRG S/M
PTRG OFF/ON
% / dB
MST / SLV
IRIG ON / OFF
APD OFF / ON
(UP / DOWN)
SYNC
AUX-1 (DIGITAL)
IN
OUT
9
!
COM
AUX-2 (IRIG-B)
IN
OUT
! SELECTOR
220V
5
EXT. CONT
REMOTE
VOLTAGE
AC FUSE
T4A
8 7 6 5 4 3 2 1
SYNC
AUX-1 (DIGITAL)
IN
OUT
TRIG/REC
IN
RAL / HLD
9.6 / 19.2
TRG S/M
PTRG OFF/ON
% / dB
MST / SLV
IRIG ON / OFF
APD OFF / ON
(UP / DOWN)
240V
DC IN
STAND BY
AC IN
DC BREAKER
XLR 32F
S
HR
HR
CANNON
CANNON
OPTION SLOT 2
D4
D3
D2
OPTION SLOT 2
OPTION SLOT 1
D1
LSB DIGITAL
OUTPUT
8
7
6
5
4
3
2
1
ANALOG
OUTPUT
D4
D3
D2
OPTION SLOT 1
D1
LSB DIGITAL
OUTPUT
8
7
6
5
4
3
2
1
ANALOG
OUTPUT
シンクケーブル
1
双方のレコーダ本体をPOWER OFFし、シンクケーブルを用いて背面パネルの
SYNCコネクタ同士を接続してください。
2
背面パネルのデジタルスイッチMST/SLVにより、一方をマスター機、他方をス
レーブ機に設定してください。スイッチを上にするとマスター機、下にすると
スレーブ機の設定になります。
3
スレーブ機 → マスター機の順にPOWER ONしてください。
4
マスター機およびスレーブ機のSYN LEDが点滅していることを確認してくださ
い。
5
リモートコントロールユニット、RS-232Cコントロール、またはEXT.コント
ロールを使用する場合は、必ずマスター機のコネクタに接続してください。
参考
スレーブ機をPOWER ONすると、次の操作をするまでLCDディスプレイのID No.表
示部にUTLモードで設定されているSYNC IDが表示されます。
17-2
17-3 操作方法
同期記録
1
記録前の設定
それぞれのレコーダにカートリッジを挿入し、それぞれのレコーダおよびチャ
ンネル拡張ユニットに対して、必要な下記の設定を個別に行なってください。
• チャンネルモード (BCM)
• 入力レンジ (RANGE)
• 入力DCオフセット (OFFSET)
! 注意
• プリトリガ記録モードでの同期運転には対応していません。背面パネルの
PTRGデジタルスイッチをOFFに設定しておいてください。
• スレーブ機の時刻はマスター機の値と同一に設定されますので、IRIG-Bタイ
ムコードはマスター機に入力してください。
2
テープ速度の選択
マスター機のSPEEDキーでテープ速度を選択します。スレーブ機のテープ速度
はマスター機の設定に連動します。
! 注意
スレーブ機を操作してもマスター機は連動しません。
3
アドレス設定
同期モードでの記録開始時にはそれぞれのレコーダのテープアドレスが自動的
にゼロリセットされ、以後記録を停止するまでマスター機に同期します。した
がって、双方のテープの対応する位置には同一のアドレスが記録されます。
4
IDナンバー
• IDナンバーのインクリメントはマスター機のIDキーを押すことにより連動し
ます。
参考
記録する直前のマスター機のIDナンバーとスレーブ機のIDナンバーが異なる
と、同期記録したテープの同期データ同士のIDナンバーが異なってしまいま
す。したがって、同一IDナンバーにするには、両方のテープの先頭から同期記
録をスタートするか、同一IDナンバーの記録部分からスタート (重ね書き) して
ください。
17-3
5
記録開始
マスター機をRECモードにすると、スレーブ機が連動し、同期記録が行なわれ
ます。RECモードにするごとにマスター機のリアルタイムのロックの値がス
レーブ機にセットされます。
REC, STOP, E-E, REC-PAUSE, FWD, FF, REWの各走行モードおよびIDナンバー
サーチはマスター機の設定に連動します。
! 注意
• スレーブ機を操作してもマスター機は連動しません。
• 同期記録はADDRESS表示で00H00M05Sより長く記録してください。
6
SYN LED
同期モードにおけるSYN LEDの表示は下記のようになります。
状態
マスター機
スレーブ機
点灯
点灯
点滅
点滅
消灯
消灯
同期記録中
同期再生中
同期再生サーチ中
STOP, FF, REW中
セルフチェック中
7
異常のとき
シンクケーブルで接続されている状態で異常が発生したときのLCD画面とSYN
LEDの表示は下記のようになります。
状態
スレーブ機
マスター機
LCD画面
SYN LED
LCD画面
SYN LED
マスター機 POWER ON
消灯
消灯
−
消灯
スレーブ機 POWER ON
EX30
消灯
消灯
消灯
ケーブル接続異常
EX30
点滅
EX30
点滅
MST/SLVスイッチ誤設定
−
消灯
−
消灯
同期再生対象データ欠
−
点滅 (単独動作)
EX31
消灯
参考
• ケーブル接続異常の状態でそれぞれのレコーダをいったんPOWER OFFし、再
度POWER ONすると、同期モードにならずに単独で動作します。
• MST/SLVスイッチ誤設定とは、例えばマスター機が1台も設定されてなかった
り、複数台設定されている状態です。
• 同期再生対象データ欠とは、スレーブ機のテープに同期再生の対象となるデー
タが存在しない状態です。
17-4
8
追記録および重ね書き
同期記録の停止後、スレーブ機のテープ位置を変化させ、たとえば下図のよう
にID=010の途中に止めた後、次の同期記録をスタートすると、マスター機は
ID=011の後のEODから、スレーブ機はID=010の途中から記録されることになり
ます。
その結果スレーブ側のID=010の部分は一部削除され、かつ新しく同期記録され
た部分のIDナンバーは、マスター機・スレーブ機それぞれ012と011になりま
す。IDナンバーが異なっていても同期再生は可能ですが、記録はマスター・ス
レーブともEODからスタートすることを推奨します。
例 1.
ID=011まで記録したマスター機のテープ
ID=010
ID=011
EOD
ID=011まで記録したスレーブ機のテープ
ID=010
ID=011
EOD
例 2.
上記EODから追記録したマスター機のテープ
ID=010
ID=011
ID=012
START
T=T0
STOP
T=T1
上記ID=010の途中から記録したスレーブ機のテープ
ID=010
ID=011
START
T=T0
STOP
T=T1
17-5
同期再生
1
再生前の設定
それぞれのレコーダに再生するテープを挿入します。
2
再生開始
マスター機のFWDキーを押すと、再生データの頭の部分がテープからメモリに
読み込まれます。同時にマスター機はスレーブ機を同じ位置のデータをメモリ
に読み込むようにコントロールします。マスター機・スレーブ機とも先頭部分
のデータがメモリに読み込まれたら同期再生がスタートします。その間マス
ターのFWD LEDは点滅します。
同期再生では、マスター機・スレーブ機とも、同一時刻にサンプルされたデー
タが同時に出力されますので、水晶精度の同期が可能です。
また、データ転送ソフトウェアPCscanIIIによって、同期記録したテープのデータ
をコンピュータに転送し、同一時刻のデータ同士をモニタしたり解析したりす
ることができます。
参考
• マスター機とスレーブ機とでチャンネルモードやアナログデジタルモードの設
定が異なる場合は、レコーダ内部の処理時間の差によって再生出力相互の間に
一定の時間差が生じます。
• 同期再生からSTOPまたはPAUSEをすると、停止位置からの同期精度を保証す
るために再生中にバッファに蓄えられたデータは捨てられます。そのためアド
レスは最大約20秒進みます。
• マスター機とスレーブ機とで走行モードが異なる場合は、マスター機 はSTOP
キー以外は受けつけません。
• 再生同期はマスター機・スレーブ機とも同一記録同士のみ可能です。異なる記
録にまたがるデータの再生同期はできません。 (「2-1 テープフォーマット」
参照)
• マスター機・スレーブ機のいずれかに×マークが表示されると同期が外れ、同
期の外れた付近を自動的にサーチして再度同期再生を開始します。
• 記録の継ぎ目では同期以外で記録されたテープを考慮し、スレーブ機は再生を
停止します。マスター機はそのまま再生を継続します。このとき、スレーブ機
はEX32エラーを表示します。
17-6
18 本体仕様
18-1 カートリッジ
名称
: SDX1-25C (MIC付き)
SDX-T3C (MIC付き)
SDX-T3N (MIC無し)
磁性体
: ピュアコバルト蒸着AME
テープベース材
: PET
テープ厚
: 7μm
テープ幅
: 8.0 mm
テープ長
: 170 m
カートリッジ外形寸法 : 95 (W) ×62 (H) ×15 (D) mm
実効データ容量
: 25 Gbyte (非圧縮時)
50 Gbyte (圧縮時)
18-2 テープ走行系
ヘッド構成
: 記録×2、再生×3
ヘッドドラム直径
: 40 mm
ヘッドドラム巻付角
: 212°
ヘッドドラム回転数
: 4800 rpm
テープ速度・相対速度 :
速度比
テープ速度 mm/s
相対速度 m/s
1 (標準速)
20.63
10.053
トラックピッチ
: 11μm
トラッキング方式
: 3T ATFエリア分割
テープエンド検出方式 : フォトセンサによる
記録/再生方向
: 正方向のみ
使用モータ
: ドラム×1、キャプスタン×1、リール×2、
テープローディング×1、カートリッジローディング×1
ドラム制御
: 速度・位相制御 (記録/再生時)
キャプスタン制御
: 速度・位相制御 (記録時)、ATF制御 (再生時)
リール制御
: 速度・定テンション制御 (記録/再生時)
FF/REW時間
: 2.5 min以下 (75倍速、170 mテープ)
サーチ速度
: 標準速の75倍 (max.)
記録方式
: NRZ飽和アジマス記録
再生方式
: PR (1.1) ビタビ復号方式
追記方式
: 直接上書き
エラー訂正
: ダブルリードソロモン
記録/再生転送レート
: 26.11 Mbps
18-3 記録/再生方式
18-1
18-4 アナログチャンネル
チャンネル数
: 8 (本体のみ)
チャンネル数拡張性
: 16
周波数帯域
:
周波数帯域
チャンネル
モード
フルアナログ
MIX
2
―
(DC∼160 kHz)×速度比
4
(DC∼160 kHz)×速度比 (DC∼80 kHz)×速度比
8
(DC∼80 kHz)×速度比
(DC∼40 kHz)×速度比
16
(DC∼40 kHz)×速度比
―
速度比は標準速 (1) に対する1/2, 1/4, 1/8, 1/16
サンプリング周波数
:帯域上限周波数×2.4
AD変換方式
: 64倍オーバーサンプリングΔ-Σ変調方式
DA変換方式
: 2∼128倍オーバーサンプリング逐次比較方式
量子化方式
: 16 bit直線
フィルタ (記録側)
: 1次アナログフィルタ+FIRデジタルフィルタ
フィルタ (再生側)
: 7次アナログフィルタ+FIRデジタルフィルタ
オーバーレンジ
: ±33 %
アナログ特性 (入力±133 %帯域内)
AC特性
周波数帯域
周波数特性
ダイナミックレンジ
クロストーク
歪率
: 周波数帯域
記録系
チャンネル間
記録系
位相差
+
再生系
2.5k∼40kHz
80k/160kHz
+1.0/−1.5 dB, 0 dB@200 Hz
76 dB以上
74 dB以上
−76 dB以下
−74 dB以下
0.016 %以下
0.02 %以下
DC∼40 kHz
40 kHz∼160 kHz
同一ユニット内 :1°
別ユニット間 :2°
3°
同一ユニット内 :2°
別ユニット間 :3°
(同一入出力条件 同期モードを除く)
DC特性
: 周波数帯域
直線性
ドリフト
各帯域
±0.1 %以内
記録:±0.1 %/2 hr以内
再生:±0.1 %/2 hr以内
(電源投入後15 minより)
入力
入力形式
18-2
:電圧入力
コネクタ
: BNC×8 (不平衡)
レンジ
: ±0.5,±1,±2,±5,±10,±20 Vpk
DCオフセット
: ±100 %
インピーダンス
: 100 kΩ
耐圧
: ±100 Vpk
5°
出力
コネクタ
: BNC×8 (不平衡)
レベル
: ±1,±2,±5, 可変 (±0.5∼±5) Vpk
インピーダンス
: 50 Ω
適合負荷
: 10 kΩ以上
LSBデジタルチャンネル
チャンネル数
:4
サンプリング周波数
:768 kHz×1/LSBチャンネルBCM×速度比
SIR-1000W
LSB デジタル
(サンプリング周波数)
テープ速度
1/1 (標準速)
1/2
1/4
1/8
1/16
LSBデジタル1 ch
768 kHz
384 kHz
192 kHz
96 kHz
48 kHz
LSBデジタル2 ch
384 kHz
192 kHz
96 kHz
48 kHz
24 kHz
LSBデジタル4 ch
192 kHz
96 kHz
48 kHz
24 kHz
12 kHz
入力
コネクタ
: BNC×4 (不平衡)
レベル
: TTL
インピーダンス
: 10 kΩ
耐圧
: ±10 Vpk
出力
コネクタ
: BNC×4 (不平衡)
レベル
: TTL
インピーダンス
: 50 Ω
適合負荷
: 1 kΩ以上
18-5 AUXデジタルチャンネル (AUX-1)
チャンネル数
:1
サンプリング周波数
: 384 kHz×速度比
入力
コネクタ
: BNC×1 (不平衡)
レベル
: TTL
インピーダンス
: 10 kΩ
耐圧
: ±10 Vpk
出力
コネクタ
: BNC×1 (不平衡)
レベル
: TTL
インピーダンス
: 50 Ω
適合負荷
: 1 kΩ以上
18-3
18-6 AUXアナログチャンネル (AUX-2)
チャンネル数
:1
周波数帯域
: DC∼ (19.2 kHz×速度比)
周波数特性
: +1/−3 dB, 0 dB @200 Hz
サンプリング周波数
: 48 kHz×速度比
S/N比
: 40 dB以上
歪率
: 1 %以下
入力
コネクタ
: BNC×1
レベル
:±2 Vpk (定格)
レベル (IRIG)
:±1.0∼ ±10 Vpk (検出範囲)
インピーダンス
: 10 kΩ
耐圧
: ±50 Vpk
出力
コネクタ
: BNC×1
レベル
: ±2 Vpk (定格)
レベル (IRIG)
:約±1.5 Vpk (固定)
インピーダンス
: 50 Ω
適合負荷
: 10 kΩ以上
18-7 ボイスチャンネル
チャンネル数
:1
周波数帯域
:100 Hz∼ (19.2 kHz×速度比)
入力 (MIC)
コネクタ
: 標準ジャック×1
AGC
: ±30 dB
インピーダンス
: 10 kΩ
出力 (PHONE)
コネクタ
: ミニジャック×1
適合負荷
: 8Ω以上
電力
: 最大400 mW @8Ω
出力 (スピーカ)
スピーカ応答帯域
18-4
: 100 Hz∼5 kHz
18-8 操作系
正面パネル
テープ走行キー
REC
STOP
FWD
FF
REW
PAUSE
: E-Eおよび記録モード
: 停止モード
: 再生モード
: 早送りモード
: 巻戻しモード
: ポーズモード
カートリッジ取出ボタン
EJECT
: カートリッジ取り出し
モード設定キー
SHIFT
SPD/BCM
RANGE
: キーのシフトおよびパネルロック
: テープ速度/チャンネルモード
: 入力レンジ
OFFSET
OUT/TSG
MRK/SLF
SEARCH
ID/UTL
/
-
: 入力DCオフセット
: 出力レベル/テスト信号
: マーク/セルフチェック
: サーチモード
: IDナンバーおよびインクリメント/ユーティリティモード
: 桁移動 (左方向)
: 桁移動 (右方向)
▲
▼
: 設定数値増大
: 設定数値減少
ディスプレイ設定キー
PK-CLR
ALL CH
SELECT
LOAD
CLOCK
: ピークインジケータクリア
: 全チャンネル同一設定
: テープ位置情報選択
: テープからの設定条件のセット
: 内部時刻設定
その他設定キー
DATA-ANN/P-SAVE : スピーカソース切換/パワーセーブモード/ファンコントロールモード
VOL
:再生音量調整
背面パネル
STAND BYスイッチ
: 主電源ON/OFF
VOLTAGE SELECTORスイッチ : AC電圧切換 (100∼120V/220∼240V)
デジタルスイッチ
RAL/HLD
9.6/19.2
TRG S/M
PTRG OFF/ON
APD OFF/ON
IRIG ON/OFF
MST/SLV
%/dB
: ピークホールドモード切換
: RS-232C伝送レート切換
: トリガモード (シングル/マルチ) 切換
: プリトリガモードOFF/ON切換
: オートパワーダウンモードOFF/ON切換
: IRIGタイムコード入出力 ON/OFF切換
: 同期運転時のマスター/スレーブ設定
: バーメータ表示切換
出力レベル調整ボリウム : 出力レベル連続可変
18-5
18-9 表示系
LCD画面
ディスプレイ形式
: 高コントラスト・広視野角LCD (バックライト付)
バーメータ
: 16 ch同時表示・%またはdBスケール切換
デジタルモード表示
: フルデジタルモード時のみ
ID
: IDナンバー (000∼999)、
オートインクリメント (A) 表示付
MONI
: モニタチャンネル表示 (01∼16)
RANGE
: 入力レンジ表示 (0.5, 1.0, 2.0, 5.0, 10, 20)
SPEED
: 記録テープ速度表示 (×1/1,×1/2,×1/4,×1/8,×1/16)
ADDRESS
: テープアドレス表示 (±時分秒)
REMAIN
: テープ残量表示 (時分)
S-TIME
: ソースタイム表示 (年月日時分秒)
T-TIME
: テープタイム表示 (年月日時分秒)
CAUTION
: 警告表示 (DC減電圧・結露・記録/再生エラー)
OVR LED
: オーバーレンジインジケータ
SPD LED
: テープ速度表示 (1, 1/2, 1/4, 1/8, 1/16)
AUX 1 LED
: AUXチャンネル1の信号有無
AUX 2 LED
: AUXチャンネル2の信号有無
EXP LED
: チャンネル拡張ユニット使用時
SYN LED
: 同期運転時
EXT TC LED
:IRIG-Bタイムコード入力時
テープ走行キー
: REC, STOP, FWD, FF, REW, PAUSE
モード設定キー
: SHIFT, PNL LOK, SPD/BCM, RANGE, SEARCH,
LCD画面上側
キーLED
ID/UTL, OFFSET, OUT/TSG, MRK/SLF,
DATA-ANN/P-SV
その他LED
18-6
POWER
: 本体POWER ON
BATT
: バッテリオペレーション
MIC
: マイク入力レベル
18-10 電源系
AC (g)
: 電圧 (定格)
電圧 (許容範囲)
周波数 (定格)
周波数 (許容範囲)
消費電力 (8 ch構成)
(16 ch構成)
待機電力
DC (
)
: 電圧 (定格)
電圧 (許容範囲)
消費電流 (8 ch構成)
(16 ch構成)
100/120 V
220/240 V
90∼132 V
198∼250 V
50/60 Hz
50/60 Hz
47∼440 Hz
47∼66 Hz
160 VA
230 VA
22 VA
130 VA
190 VA
17 VA
12 V
11∼30 V
7.0 A @12V
5.5 A @24V
バッテリ
BP-L60
: 14.4 V 4.5 Ah
BP-L90
: 14.4 V 6.7 Ah
BP-L60A
: 14.4 V 5.4 Ah
BP-L90A
: 14.4 V 8.1 Ah
電源優先順位
: AC>DC>バッテリ
18-11 外形寸法・質量
外形寸法
: 340(W)×115(H)×260(D) mm (突起部含まず)
質量
: 約7.7 kg (本体のみ)
動作保証温湿度
: 0∼40℃, 20∼80% RH (結露なきこと)
18-12 使用環境
(5℃未満の低温使用時は15分以上のウォームアップが必要)
保存温湿度
: −10∼50℃, 10∼90% RH (結露なきこと)
性能保証気圧
: 860∼1060 hPa
使用姿勢
: 水平 (正面パネル前向き)、垂直 (正面パネル上向き)
耐振性
: MIL-STD-810C, ±14.7 m/s2 (±1.5G) (水平姿勢)
耐衝撃性
: 392 m/s2 (40 G), 11 ms (保存状態)
汚損度
: II
設置等級
: II
18-7
18-13 標準付属品
AC電源コード (100∼120V用、3P) : 1
AC電源コード (220∼240V用、2P) : 1
プラグ変換アダプタ (3P-2P)
: 1
DC電源コード
: 1
ダイナミックマイクロホン
: 1
時計ドライバ
: 1
ヒューズ
: 1
カートリッジ
: 1
クリーニングテープ
: 1
フィルタ (SIR用ダストフィルタ)
: 2
取扱説明書
: 1
検査書
: 1
! 注意
• 本製品はワールドワイドモデルです。使用地域に合った付属品をご使用ください。
• プラグ変換アダプタ (3P-2P) をご使用の場合は、緑色のコードを必ず接地してくだ
さい。
18-8
19 オプション付属品の仕様
19-1 バッテリパック (BP-L60/L60A/L90/L90A)
形式
: 充電式リチウムイオンバッテリ
BP-L60/L60A
BP-L90/L90A
最大電圧
16.6 V
16.6 V
公称電圧
14.4 V
14.4 V
公称容量
60 Wh/65 Wh
90 Wh/100 Wh
外形寸法
101×37×169 mm
101×60×169 mm
約0.9 kg
約1.3 kg
質量
使用温度
: −20∼45℃
製造元
: ソニー (株)
19-2 バッテリチャージャ
電源
: AC 100∼240 V, 50/60 Hz
消費電力
: 160 VA @100 V, 200 VA @240 V
(リチウムイオンバッテリの場合)
出力
: DC 16.8 V, 4.4 A
充電方式
: 定電圧定電流充電制御
使用温度
: −20∼45℃
外形寸法
: 120(W)×131(H)×330(D) mm (突起部含まず)
質量
: 約2 kg
製造元
: ソニー (株)
19-3 リモートコントロールユニット(SRM-10)
テープ走行キー
: REC, STOP, FWD, FF, REW, PAUSE
モード設定キー
: ID, RANGE, OFFSET, PNL LOK, 8, -
ディスプレイ部キー
: PK-CLR, ALL CH, SELECT, LOAD
ディスプレイ画面
: レコーダ本体と同一
確認表示LED
: LOADING, BOD, EODおよび
テープ走行キー、モード設定キー
インターフェース
: RS-232C準拠
ケーブル長
: 約3 m
外形寸法
: 210 (W)×25 (H)×70 (D) mm (突起部含まず)
質量
: 約0.5 kg
19-1
19-4 チャンネル拡張ユニット (SCX-16W)
記録/再生系
チャンネル数
: 8 (本体のみ)
チャンネル数拡張性
: 16
周波数帯域
:
1/1 (標準速)
SIR-1000W
+
SCX-16W
40 kHz
1/2
1/4
1/8
1/16
20 kHz
10 kHz
5 kHz
2.5 kHz
速度比は標準速 (1) に対する1/2, 1/4, 1/8, 1/16
サンプリング周波数
:帯域上限周波数×2.4
AD変換方式
: 64倍オーバーサンプリングΔ-Σ変調方式
DA変換方式
: 2∼128倍オーバーサンプリング逐次比較方式
量子化方式
: 16 bit直線
フィルタ (記録側)
: 1次アナログフィルタ+FIRデジタルフィルタ
フィルタ (再生側)
: 7次アナログフィルタ+FIRデジタルフィルタ
オーバーレンジ
: ±33 %
アナログ特性 (入力±133 %帯域内)
AC特性
:
周波数帯域
周波数特性
ダイナミックレンジ
クロストーク
歪率
周波数帯域
チャンネル間
位相差
2.5k∼40kHz
80k/160kHz
+1.0/−1.5 dB, 0 dB@200 Hz
76 dB以上
74 dB以上
−76 dB以下
−74 dB以下
0.016 %以下
0.02 %以下
DC∼40 kHz
40 kHz∼160 kHz
記録系
同一ユニット内:1°
別ユニット間 :2°
3°
記録系
+
再生系
同一ユニット内:2°
別ユニット間 :3°
(同一入出力条件 同期モードを除く)
DC特性
: 周波数帯域
直線性
ドリフト
各帯域
±0.1 %以内
記録:±0.1 %/2 hr以内
再生:±0.1 %/2 hr以内
(電源投入後15 minより)
入力
入力形式
19-2
:電圧入力
コネクタ
: BNC×8 (不平衡)
レンジ
: ±0.5,±1,±2,±5,±10,±20 Vpk
DCオフセット
: ±100 %
インピーダンス
: 100 kΩ
耐圧
: ±100 Vpk
5°
出力
コネクタ
: BNC×8 (不平衡)
レベル
: ±1,±2,±5, 可変 (±0.5∼±5) Vpk
インピーダンス
: 50 Ω
適合負荷
: 10 kΩ以上
モニタ系
バーメータ
: 9∼16 ch同時表示、片振れ、
%とdB表示
確認表示LED
電源
: POWER
周波数帯域
: 40 k, 20 k, 10 k, 5 k, 2.5 k
警告表示LED
: OVR (各chオーバーレンジ)
入力電圧
: DC 12 V (定格), 11∼30 V (許容範囲)
消費電流
: 4.0 A @12 V
外形寸法
: 340 (W)×65 (H)×250 (D) mm (突起部含まず)
質量
: 約3.5 kg (ユニットのみ)
動作保証温湿度
: 0∼40℃, 20∼80% RH (結露なきこと)
保存温湿度
: −10∼50℃, 10∼90% RH (結露なきこと)
性能保証気圧
: 860∼1060 hPa
使用姿勢
: 水平 (正面パネル前向き)、垂直 (正面パネル上向き)
耐振性
: MIL-STD-810C, ±14.7 m/s2 (±1.5G) (水平姿勢)
耐衝撃性
: 392 m/s2 (40 G), 11 ms (保存状態)
汚損度
: II
設置等級
: II
DC電源ケーブル
:1
拡張ケーブル
:1
電源系
外形寸法・質量
使用環境
標準付属品
チャンネル拡張ボード : 1
コンバインフレーム
:4
六角穴付ボルト
: 12
Lレンチ
:1
取扱説明書
:1
検査書
:1
19-3
19-5 その他のオプション
• ラックマウントアダプタ (SRT-10)
本体をラックに取付けるアダプタ
• ラックマウントアダプタ (SRT-20)
拡張ユニットをラックに取付けるアダプタ
• ショックマウントアダプタ (SSM-10)
大きい振動レベルを抑制するアダプタ
• トランクケース (STC-10)
本体を収納するトランクケース
• トランクケース (STC-23)
本体と拡張ユニットを収納するトランクケース
• ビットストリームボード (SBS-10A)
ビットストリームデータを非同期式で記録するボード
• ビットストリームボード (SBS-10S)
ビットストリームデータを同期式で記録するボード
• レベルコンバータボックス (SBS-LC1)
SBS-10A/Sの差動入力信号をTTL/バイポーラ信号に変
換するボックス
• SDX SCSI エミュレーションボード (STB-10)
SIRで記録したデジタルデータをSCSI転送するボード
• 高速SCSI転送ボード (STB-30)
SIRで記録したデジタルデータをリアルタイムにSCSI転
送するボード
• データ転送/表示ソフトウェア (PCscanIII)
SIRで記録したデジタルデータを転送/表示するソフト
ウェア
• MPEGビデオボード (SVB-10)
ビデオ信号をSIRで記録/再生するボード
• 同期ボックス (SSB-10)
最大8台のSIRを同期させるBOX
• AITドライブ (SDX-S300C)
AITテープストリーマドライブ
上記オプション商品の詳細についてはカタログをご参照ください。
19-4
AMP
CHD4 LSB DIGITAL I/O
CHD1 LSB DIGITAL I/O
CH-8 ANALOG OUTPUT
CH-8 ANALOG INPUT
CH-1 ANALOG OUTPUT
CH-1 ANALOG INPUT
TRIG/REC IN
AUX-1 (DIGITAL)
PHONE
MIC
AMP
CHG
AC/DC
AUX-2 (IRIG-B)
BATT
AC
DC
Oversampling
AD
Analog
LPF
AMP
Serial
I/F
Oversampling
AD
Analog
LPF
Oversampling
AD
Analog
LPF
AMP
ATT
Oversampling
AD
RTC
Analog
LPF
PLL
Clock
GEN
DC/DC
ATT
Serial
I/F
A/D
D/A
A/D
D/A
IRIG
Decoder
PWR
CPU
Select
Interp.
DF
Deci.
DF
Interp.
DF
Deci.
DF
Analog
CPU
Mixer
Bar Meter
CTL
SYNC
DSP
for
Calibration
Buffer
Memory
(FIFO Memory)
Buffer
Manager
and DMA
(CPU)
RS-232C Remocon
MAIN
CPU
Keys
SDX Drive
Program
Memory
(Flash)
Display
Channel
Expansion/Bit Stream
/MPEG VIDEO
Board
OPTION SLOT 2
SCSI
Emulation/Transfer
Board
OPTION SLOT 1
SCSI
CTL
EXT
CTL
20 資料
20-1 Block Diagram
20-1
索引
記号・数値
%/dB (デジタルスイッチ) .................................. 3-26
; キー .................................................................... 3-13
: キー .................................................................... 3-13
8 キー .................................................................... 3-13
9 キー .................................................................... 3-13
3 電源方式 ............................................................... 1-4
9.6/19.2 (デジタルスイッチ) .............................. 3-25
A
AC IN ..................................................................... 3-24
AC 電圧切換スイッチ .......................................... 3-24
AC 電源 .................................................................... 4-1
AC ヒューズ .......................................................... 3-24
ADDRESS (アドレス) 表示 ............................... 5-11
AIT (Advanced Intelligent Tape) 技術 .................. 1-1
AIT カートリッジ ................................................... 1-2
AIT ドライブ (SDX-300C) .................................. 19-4
AIT ドライブとの互換性 ....................................... 1-4
ALL CH キー ......................................................... 3-19
ANALOG INPUT コネクタ (SCX-16W) ............ 16-3
ANALOG INPUT コネクタ (SIR-1000W) .......... 3-21
ANALOG MONITOR コネクタ ........................... 3-21
ANALOG OUTPUT コネクタ (SCX-16W) ....... 16-4
ANALOG OUTPUT コネクタ (SIR-1000W) ...... 3-28
ANN/P-SV キー ..................................................... 3-14
APD OFF/ON (デジタルスイッチ) ................... 3-26
AUX LED (1, 2) .................................................... 3-15
AUX-1 (DIGITAL) IN/OUT ................................ 3-27
AUX-2 (IRIG-B) IN/OUT ................................... 3-27
AUX アナログチャンネル ................................... 18-4
AUX アナログデータ ...................................... 8-1, 8-4
AUX デジタルチャンネル ................................... 18-3
AUX デジタルデータ ...................................... 7-1, 7-2
D
DC IN (SCX-16W) ................................................ 16-4
DC IN (SIR-1000W) ............................................. 3-25
DC 減電圧 .............................................................. 4-12
DC サーキットブレーカ ............................. 3-25, 16-4
DC 電源 .................................................................... 4-2
E
EJECT ボタン .......................................................... 3-3
EMERGENCY EJECT ............................................. 3-3
EOD LED ................................................................. 3-6
EOD サーチ ........................................................... 10-3
EXP LED ................................................................ 3-15
EXPANSION IN コネクタ ................................... 16-4
EXT TC LED ......................................................... 3-15
EXT. CONT コネクタ ........................................... 3-27
EXT. コントロール ............................................... 11-1
F
FF キー ..................................................................... 3-5
FMT .......................................................................... 2-2
FWD-PAUSE (再生ポーズ) モード ................... 5-13
FWD キー ................................................................ 3-5
I
ID/UTL キー .......................................................... 3-11
ID サーチ ............................................................... 10-1
ID ナンバー ........................................................... 5-10
ID ナンバーサーチ ............................................... 10-2
ID ナンバーのインクリメント ........................... 5-10
ID 表示エリア ....................................................... 3-17
ID ブロック ............................................................. 2-3
IRIG-B タイムコード信号 .............................. 8-2, 8-3
IRIG ON/OFF (デジタルスイッチ) .................... 3-26
B
BAND LED ............................................................ 16-3
BATT LED ............................................................... 3-2
Block Diagram ........................................................ 20-1
BOD LED ................................................................. 3-6
C
CAL (キャリブレーション) モード ................... 4-9
CAUTION 表示エリア ......................................... 3-17
CLOCK キー .......................................................... 3-20
COM コネクタ ...................................................... 3-27
L
LCD 画面 ...................................................... 3-15, 18-6
LOADING LED ....................................................... 3-3
LOAD キー ............................................................ 3-20
LSB DIGITAL INPUT コネクタ .......................... 3-22
LSB DIGITAL OUTPUT コネクタ ...................... 3-29
LSB デジタルデータ信号系の接続 ...................... 5-1
LSB デジタル出力部 ............................................ 3-29
LSB デジタルチャンネル ............................. 1-2, 18-3
LSB デジタルチャンネルモード (BCM) ............ 5-3
–I–
LSB デジタル入力部 ............................................ 3-22
M
MIC (Memory In Cartridge) .................................... 2-2
MIC ジャック ........................................................ 3-14
MONI 表示エリア ................................................. 3-17
MPEG ビデオボード (SVB-10) .......................... 19-4
MRK (マーク) サーチ ........................................ 10-3
MRK/SLF キー ...................................................... 3-10
MST/SLV (デジタルスイッチ) ........................... 3-26
TOC .......................................................................... 2-2
TSG (テスト信号) モード .................................... 5-7
TRG S/M (デジタルスイッチ) ............................ 3-25
TRIG/REC IN コネクタ ........................................ 3-27
O
V
OFFSET .................................................................... 5-5
OFFSET キー ........................................................... 3-9
OUT/TSG キー ...................................................... 3-10
OVR LED ............................................................... 3-15
VOL つまみ ........................................................... 3-14
P
PAUSE キー ............................................................. 3-5
PHONE ジャック .................................................. 3-14
PK-CLR キー ......................................................... 3-19
POWER LED (SCX-16W) .................................... 16-2
POWER LED (SIR-1000W) ................................... 3-2
PTRG OFF/ON (デジタルスイッチ) .................. 3-25
R
RAL/HLD (デジタルスイッチ) .......................... 3-25
RANGE .................................................................... 5-4
RANGE キー............................................................ 3-9
RANGE 表示エリア.............................................. 3-17
REC-PAUSE (記録ポーズ) モード ...................... 5-9
REC キー.................................................................. 3-5
REMAIN (テープ残量) 表示 .............................. 5-11
REMOTE コネクタ ............................................... 3-27
REW キー ................................................................ 3-6
RS-232C ................................................................. 12-1
S
SCSI インターフェース ......................................... 1-4
SDX SCSI エミュレーションボード (STB-10) ............... 19-4
SEARCH キー ........................................................ 3-11
SELECT キー ......................................................... 3-19
SHIFT キー .............................................................. 3-8
SLF (セルフチェック) モード ............................. 4-8
SPD ........................................................................... 5-4
SPD LED ................................................................ 3-15
SPD/BCM キー ........................................................ 3-8
SPEED 表示エリア ............................................... 3-17
– II –
STAND BY スイッチ ........................................... 3-24
STOP キー ................................................................ 3-5
SYN LED ............................................................... 3-15
SYNC コネクタ ..................................................... 3-27
T
ア行
アース端子 (SCX-16W) ....................................... 16-4
アース端子 (SIR-1000W) .................................... 3-27
アドレス (ADDRESS) 表示 ............................... 5-11
アドレスサーチ .................................................... 10-4
アナログチャンネル ............................................ 18-2
アナログチャンネルモード (BCM) ..................... 5-3
アナログチャンネルモード LED ........................ 3-21
アナログデータ信号系 .......................................... 5-1
アナログ出力部 .................................................... 3-28
アナログ入力部 .................................................... 3-21
インターフェース .............................. 11-1, 12-1, 15-2
エジェクト .............................................................. 2-3
エラーコード ........................................................ 4-10
エラーフリー記録 .................................................. 1-3
オプションスロット ............................................ 3-28
オプション付属品 ................................................ 19-1
カ行
ガードフレーム (SHL-10) ................................... 13-1
カートリッジ .................................. 4-4, 4-5, 4-6, 18-1
カートリッジ蓋 ...................................................... 3-2
カートリッジ挿入口 .............................................. 3-3
外形寸法 (SCX-16W) ........................................... 19-3
外形寸法 (SIR-1000W) ........................................ 18-7
重ね書き .................................................................. 2-3
キー LED ................................................................ 18-6
キャリブレーション ............................................ 16-8
キャリブレーションモード .................................. 4-9
記録 / 再生方式 ..................................................... 18-1
記録 (アナログモード) ....................................... 16-8
記録 / 再生エラー ................................................. 4-13
クリーニングテープ .............................................. 4-7
警告表示 ................................................................ 4-12
結露 ........................................................................ 4-12
高速 SCSI 転送ボード (STB-30) ......................... 19-4
コマンド ....................................................... 12-2, 12-4
コントロール機能 .................................................. 1-4
コントロール部 .................................................... 3-27
コンバインフレーム ............................................ 16-6
サ行
サーチ .................................................................... 10-1
再生 (アナログモード) ....................................... 16-8
サブチャンネル ...................................................... 1-2
時間軸変換 .............................................................. 1-3
時間軸変換再生 .................................................... 5-14
質量 (SCX-16W) ................................................... 19-3
質量 (SIR-1000W) ................................................ 18-7
出力レベル切換 .................................................... 5-13
出力レベル調整ボリウム (SCX-16W) ............... 16-4
出力レベル調整ボリウム (SIR-1000W) ............ 3-28
使用環境 ....................................................... 18-7, 19-3
正面パネル (SCX-16W) ....................................... 16-2
正面パネル (SIR-1000W) ............................. 3-1, 18-5
ショックマウントアダプタ (SSM-10) .............. 19-4
信号系 ...................................................................... 5-1
スタート ID サーチ .............................................. 10-2
ステータスコマンド ................................... 12-3, 12-8
スピーカ ................................................................ 3-31
設定コマンド ............................................... 12-2, 12-4
セルフチェック ...................................................... 4-8
操作系 .................................................................... 18-5
ソースモード ........................................................ 4-14
タ行
チャンネル拡張ユニット (SCX-16W) ...... 16-1, 19-2
チャンネルモード LED ........................................ 3-22
通風孔 (SCX-16W) ............................................... 16-5
ディスプレイキーエリア .................................... 3-19
データ記録 ....................................................... 5-1, 5-8
データ再生 ..................................................... 5-1, 5-12
データ信号系 ........................................................ 16-8
データ転送 / 表示ソフトウェア (PCscanIII) ..... 19-4
データの保護 .......................................................... 4-7
データモード設定キーエリア .............................. 3-7
テープフォーマット .............................................. 2-1
テープモード ........................................................ 4-14
テープ位置表示エリア ........................................ 3-18
テープ残量 (REMAIN) 表示 .............................. 5-11
テープ走行キーエリア .......................................... 3-4
テープ走行系 ........................................................ 18-1
テープ速度 (SPD) .................................................. 5-4
デジタルスイッチ ................................................ 3-25
テスト信号 (TSG) モード ..................................... 5-7
電源 .......................................................................... 4-1
電源 / ドライブ部 ................................................... 3-2
電源系 (SCX-16W) ............................................... 19-3
電源系 (SIR-1000W) ............................................ 18-7
電源部 .................................................................... 3-24
同期運転 .................................................................. 1-3
同期記録 ................................................................ 17-3
同期再生 ................................................................ 17-6
同期ボックス (SSB-10) ....................................... 19-4
同期モード ............................................................ 17-1
トランクケース (STC-10) ................................... 19-4
トランクケース (STC-23) ................................... 19-4
トリガ記録 ................................................ 1-3, 9-1, 9-2
トリガ信号系 .......................................................... 9-1
取外しボタン (バッテリ) ................................... 3-30
ナ行
内部時刻 .................................................................. 5-6
入力 DC オフセット (OFFSET) ............................ 5-5
入力レンジ (RANGE) ............................................ 5-4
ハ行
バーメータ ............................................................ 16-2
バーメータエリア ................................................ 3-16
背面パネル (SCX-16W) ....................................... 16-4
背面パネル (SIR-1000W) ........................... 3-23, 18-5
バッテリチャージャ ............................................ 19-1
バッテリパック .................................... 4-3, 14-1, 19-1
バッテリパック装着部 ........................................ 3-30
左側面パネル (SCX-16W) ................................... 16-5
左側面パネル (SIR-1000W) ................................ 3-30
ビットストリームデータ ...................................... 1-2
ビットストリームボード (SBS-10A/S) ............. 19-4
表示系 .................................................................... 18-6
標準付属品 (SCX-16W) ....................................... 19-3
標準付属品 (SIR-1000W) .................................... 18-8
ファンコントロールモード ................................ 4-15
フィルタ (通風孔) (SIR-1000W) ....................... 3-30
プリトリガデータの再生 ...................................... 9-2
フォーマット (FMT) ............................................. 2-2
ボイスチャンネル ................................................ 18-4
ボイスメモ ....................................................... 6-1, 6-2
マ行
マークサーチ ........................................................ 10-3
– III –
マイク・イヤホン .................................................. 6-1
右側面パネル (SCX-16W) ................................... 16-5
右側面パネル (SIR-1000W) ................................ 3-31
モニタ ............................................................. 5-9, 5-13
モニタ系 ................................................................ 19-3
ラ行
ラックマウントアダプタ (SRT-10) ................... 19-4
ラックマウントアダプタ (SRT-20) ................... 19-4
リアルタイムクロックサーチ ............................ 10-4
リモートコントロールユニット (SRM-10) .... 15-1, 19-1
レコーダ本体による充電方法 ............................ 14-2
冷却ファン (SCX-16W) ....................................... 16-5
冷却ファン (SIR-1000W) .................................... 3-31
レベルコンバータボックス (SBS-LC1) ............ 19-4
ローディング .......................................................... 4-5
– IV –
このマニュアルに記載されている事柄の著作権は当社にあ
り、説明内容は機器購入者の使用を目的としています。
したがって、当社の許可なしに無断で複写したり、説明内
容(操作、保守など)と異なる目的で本マニュアルを使用
することを禁止します。
The material contained in this manual consists of
information that is the property of Sony Precision
Technology Inc. and is intended solely for use by the
purchasers of the equipment described in this manual.
Sony Precision Technology Inc. expressly prohibits
the duplication of any portion of this manual or the use
thereof for any purpose other than the operation or
maintenance of the equipment described in this
manual without the express written permission of
Sony Precision Technology Inc.
Le matériel contenu dans ce manuel consiste en
informations qui sont la propriété de Sony Precision
Technology Inc. et sont destinées exclusivement à
l'usage des acquéreurs de l'équipement décrit dans
ce manuel.
Sony Precision Technology Inc. interdit formellement
la copie de quelque partie que ce soit de ce manuel ou
son emploi pour tout autre but que des opérations ou
entretiens de l'équipement à moins d'une permission
écrite de Sony Precision Technology Inc.
Die in dieser Anleitung enthaltenen Informationen
sind Eigentum von Sony Precision Technology Inc.
und sind ausschließlich für den Gebrauch durch den
Käufer der in dieser Anleitung beschriebenen
Ausrüstung bestimmt.
Sony Precision Technology Inc. untersagt
ausdrücklich die Vervielfältigung jeglicher Teile dieser
Anleitung oder den Gebrauch derselben für
irgendeinen anderen Zweck als die Bedienung oder
Wartung der in dieser Anleitung beschriebenen
Ausrüstung ohne ausdrückliche schriftliche Erlaubnis
von Sony Precision Technology Inc.
Sony Precision Technology Inc.
Sony Precision Technology America, Inc.
Measuring Products Division
California:
Suzukawa, 45, Isehara-shi,
Kanagawa, 259-1146 Japan
20381 Hermana Circle
Lake Forest, CA 92630, U.S.A.
TEL: (949) 770-8400
FAX: (949) 770-8408
TEL: +81 (463) 92-1975
FAX: +81 (463) 92-6863
Sony Precision Technology Europe GmbH
Sony Precision Technology Taiwan Ltd.
Hedelfinger Strasse 61 D-70327 Stuttgart-Wangen, Germany
TEL: (0711) 5858-300
Rm. 1501, Chia Hsin Bldg., Top Fl., 96, Chung Shan N.Rd., Sec.2,
Taipei Taiwan
FAX: (0711) 580715
TEL: (02) 2531-7650
FAX: (02) 2531-3835
商品についてのお問い合わせ
ソニー・プレシジョン・テクノロジー株式会社
東京営業所
〒141-0031
東京都品川区西五反田3-9-17 東洋ビル
TEL (03)3490-3911
FAX (03)3490-8028
名古屋営業所
大阪営業所
〒465-0095
〒532-0011
名古屋市名東区高社2-171
大阪市淀川区西中島2-14-6 新大阪第2ドイビル
TEL (052)778-3181
TEL (06)6305-3101
FAX (052)778-4147
FAX (06)6304-6586
福岡営業所
〒810-0072
福岡市中央区長浜1-4-13 ソニー福岡第2ビル
TEL (092)713-6388
FAX (092)713-6396
サービス連絡先
サービス代行店
エスピーティ・エンジニアリング株式会社
サービスセンター
〒259-1146 神奈川県伊勢原市鈴川45 ソニー・プレシジョン・テクノロジー株式会社 伊勢原事業所内
TEL (0463) 92-2132 FAX (0463) 92-3090
北海道地区: 札幌 (株)札幌トランジスタ
東北、関東、甲信越地区: 横浜 (株)ファーストビデオ
近畿、中国、四国地区: 大阪 (有)宮下電機サービス
広島 (株)三田電子
TEL
TEL
TEL
TEL
(011)631-3401
(045)582-8649
(06)6724-7005
(082)272-6290
Printed in Japan
SIR-1000W/SCX-16W
2000.7
2-914-150-01
©1999
このマニュアルは再生紙を使用しています。
Published by Sony Precision Technology Inc.
Fly UP